Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56239958

Tender For Special Repair To Chs Plant No Six And Seven And Allied Works At Transit C Under Age E/M-I Of Ge 865 Ews

Issued by Statutory Bodies & Commissions/Committees · leh, Ladakh
Tender Value
1.44 Crore
Estimated cost
Bid Submission
28 Jul 2026
18 days left
EMD
2.19 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Chs Plant No Six And Seven And Allied Works At Transit C Under Age E/M-I Of Ge 865 Ews

BOQ

Name of Work:- SPECIAL REPAIR TO CHS PLANT NO SIX AND SEVEN AND ALLIED WORKS AT TRANSIT C UNDER AGE E/M-I OF GE 865 EWS
Sl. No. Item Description
1Dismantling of burner assembly of CHS and removing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity upto 04 lakh kilo/cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, complete all as specified and/or as directed by Engr-in Charge.Note :- New sequence controller, ignition rod, ignition transformer, temp controller, photo cell electrode, burner nozzle, hooter and bridge rectifier shall be measured and paid under respective item.
2Dismantling of boiler capacity 04 lakh kilo/cal/hr disconnecting all electric/ fuel/ water connection of unsv glycol tubing to isolate combustion chamber of boiler and with help of tripod and chain pully without damaging internal chamber and supply and fix of Boiler Coil for 04 lakh kilo/cal/Hr capacity Central Heating Plant as per existing shape size & dimension as per manufactures recommendation all as specified and directed by Engr-in-Charge. Make : Aquatherm,Themax or equivalent make as approved by GE.
3Supply and fix in replacement sequence controller suitable for 4 lakh kilo/hr with burner rod assembly, complete all as specified and/ or as directed by Engr-in-Charge. Make- Siemens or equivalent make as approved by GE.
4Supply and fix in replacement ignition rod suitable for 4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and/ or as directed by Engr-in-Charge.
5Supply and fix in replacement ignition Transformer electronic type suitable for 4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and/ or as directed by Engr-in-Charge.
6Supply and fix in replacement temperature controller digital type DTC 503 with sensor suitable for 4 lakh kilo/Cal/hr LAL 2.25 burner rod assembly, complete all as specified and/ or as directed by Engr-in-Charge.
7Supply and fix in replacement pressure gauage 0 to 10.6 Kg/cm sq as per existing, complete all as specified and/ or as directed by Engr-in-Charge.
8Supply and fix in replacement photo cell as per existing suitable for 4 lakh kilo/Cal/hr burner rod assembly, complete all as specified and/ or as directed by Engr-in-Charge.
9Supply and fix in replacement burner nozzle suitable for 4 lakh K/Cal/Hr, complete all as specified and/ or as directed by Engr-in-Charge.
10Supply and fix in replacement Electrode suitable for burner of capacity 3-4 lakh K/Cal/Hr, complete all as specified and/ or as directed by Engr-in-Charge.
11Supply and fix in replacement Bridge rectifire, complete all as specified and/ or as directed by Engr-in-Charge.
12Supply and fix in replacement hooter round type, complete all as specified and/ or as directed by Engr-in-Charge.
13Supply and fix in replacement thermostate assembly tail type as per existing suitable for 0-70 degree centrigrade temprature, complete all as specified and/ or as directed by Engr-in-Charge. Make- Honeywell or equivalent make as approved by GE.
14Supply and fix in replacement oil pressure pump 7276-3D67A, complete all as specified and/ or as directed by Engr-in-Charge. Make- Suntec or equivalent make as approved by GE.
15Supply and fix in replacement Fuel filter 1/2 ltr, complete all as specified and/ or as directed by Engr-in-Charge. Make- Kirloskar/Mico/TVS or equivalent make as approved by GE.
16Supply and fix in replacement auto air pressure valve 3/8\\" as per existing, complete all as specified and/ or as directed by Engr-in-Charge.
17Supply and fix in replacement High pressure fuel pipe 1.5 mtr long as per existing, complete all as specified and/ or as directed by Engr-in-Charge.
18Supply and fix in replacement diesel burner set of capacity upto 4 Lac K Cal/Hr comprising of diffuser, nozzle, electrodes, blast tube, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, frame detector and controller, complete all as specified and/ or as directed by Engr-in-Charge.
19Supply and fix in replacement of Chilled / Hot water wall mounting indoor type Fan Coil Unit (FCU) 4500 Lakh K Cal / Hrs capacity including 02 Nos of 20 mm Valve with stainer (inlet & outlet) including heavy duty PVC Pipe for connection, complete all as specified and directed by Engr-in-Charge. Make : Carryaire or approved equivalent make.
20Supply and fix in replacement of Chilled / Hot water wall mounting indoor type Fan Coil Unit (FCU) 6000 Lakh K Cal / Hrs capacity including 02 Nos of 20 mm Valve with stainer (inlet & outlet) including heavy duty PVC Pipe for connection, complete all as specified and directed by Engr-in-Charge. Make : Carryaire or approved equivalent make.
21Material and labour for complete cleaning and checking the serviceability of FCU of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare parts like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line anywhere about the premises and cleaning with the chemical solution by pressure pump from inlet to outlet to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engr-in- Charge all as directed at site.
22Supply and fix in replacement of duel shaft electric motor 1/12 HP, 30 watt 930 RPM, 3 speed for fan coil unit as per existing, complete all as specified and/ or as directed by Engr-in-Charge. Make- Maratan/CEG or equivalent make as approved by GE.
23Supply and fix in replacement Brass nipple thread size 20 mm for floor mounting FCU to flexible pipe laid in floors or trenches complete all as specified and/ or as directed by Engr-in-Charge.
24Supply and fix in replacement Brass Tee thread size 20 mm for connecting double FCU in flexible pipe to flexible pipe laid in floors or trenches complete all as specified and/ or as directed by Engr-in-Charge.
25Supply and fix in replacement of FCU connection multi layer composite flexible pipe 20/16 mm as per existing, complete all as specified and/or as directed by Engr-In-Charge. Make- Jindal/Unipro Mecto or equivalent make as approved by GE.
26Supply, fixing, testing and installation of pump set of capacity 7.5 HP Pump set, three phase 415 volts, 50 Hz with flow rate of 18.0 ltrs/Second hour having head upto 18.00 mtrs including taking down of unserviceable pump, complete all as specified and/or as directed by Engr-in-Charge.
27Supply, fixing, testing and installation of pump set of capacity 2.0 HP Pump set, three phase 415 volts, 50 Hz, with flow rate of 505 ltrs per hour having head upto 20 mtrs including taking down of unserviceable pump, complete all as specified and/or as directed by Engr-in-Charge.
28Supply, fixing, testing and installation of pump set of capacity 0.5 HP Pump set, single phase, 240 volts, 50 Hz with flow rate of 1950 ltrs per hour having head upto 21 mtrs including taking down of unserviceable pump, complete all as specified and/or as directed by Engr-in-Charge.
29Taking out the unservicable MS pipe of size 65 to 150 mm from trench/ air including connecting accessories complete all as specified and/or as directed by Engr-in-Charge.
30Supply and laying in replacement MS pipe heavy grade with all fittings liad in trenches/ overhead on supports of size 100mm bore conforming to IS 1239 including all fittings such as bends (any type, radius or angle), tapers (any type, straight, bend, increasing or double sockets etc.), TEE pieces single branch, 'Y' Junction, double branch, cross collars, cap and end plug, MS flanges complete bends, TEE pieces, collars, elbow, tail pieces, etc. complete all as specified and/or as directed by Engr-in-Charge.
31All as per Srl Item No 30 above, but of size 80mm bore.
32All as per Srl Item No 30 above, but of size 65mm bore.
33All as per Srl Item No 30 above, but of size 50mm bore.
34Supply and laying in replacement 3 layer PP-R Polypropylene random copolymer concealed pipes of 40 mm dia bore, SDR 6 (PN 20) for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings, laid in floors or trenches etc. complete all as specified and/or as directed by Engr-in-Charge. Make : Sant/SFMC or equivalent make as approved by GE.
35All as per Srl Item No 34 above, but of size 32mm dia bore.
36All as per Srl Item No 34 above, but of size 25mm dia bore.
37Supply and fix insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet all around for 100 mm dia of pipe, complete all as specified and/or as directed by Engr-in Charge.
38Supply and fix insulation of MS Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet all around for 80 mm dia of pipe, complete all as specified and/or as directed by Engr-in Charge.
39Supply and fix insulation of MS Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet all around for 65 mm dia of pipe, complete all as specified and/or as directed by Engr-in Charge.
40Supply and fix insulation of MS Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet all around for 50 mm dia of pipe, complete all as specified and/or as directed by Engr-in Charge.
41Supply and fix insulation of PPR Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet all around for 40 mm dia of pipe, complete all as specified and/or as directed by Engr-in Charge.
42Supply and fix insulation of PPR Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet all around for 32 mm dia of pipe, complete all as specified and/or as directed by Engr-in Charge.
43Supply and fix insulation of PPR Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet all around for 25 mm dia of pipe, complete all as specified and/or as directed by Engr-in Charge.
44Supply and fix in replacement of gun metal butter fly control valves of 100mm bore as per existing, complete all as specified and/or as directed by Engr-in Charge.
45Supply and fix in replacement of balancing valve of 100mm dia, complete all as specified and/or as directed by Engr-in Charge.
46Supply, fixing, testing and installation of fuel pump and motor of capacity 1 HP, single phase, 215 Volts including taking down of unserviceable pump and motor, complete all as specified and/or as directed by Engr-in-Charge.
47Excavating in post holes (or similar holes) each not exc. 0.5 cum in hard/dense soil, getting out and removing surplus soil to a distance not exc. 50m and making good surface complete all as specified and/ or as directed by Engr-in-Charge.
48Material and labour for PCC 1:4:8 type D-2, (using 40mm graded crushed stone aggregate) as in lean conc, sub base or mass concrete and foundation filling complete all as specified and/ or as directed by Engr-in-Charge.
49Supply and fix cross arms bracing support clamps, back plates fabricated from steel section made out of Fe-310/Fe-410 including nuts, bolts and washers, welding, drilling hole including two coats of aluminium paint over one coat of primer complete all as specified and/ or as directed by Engr-in-Charge.
50Material and labour for disconnecting all connections in existing boiler control panel board complete and re-fixing the same after removing the burnt lugs/thimbles complete including replacing the U/S MCB/MCCBs, Contactors, relay, control wiring, indicator lamps, selector switch etc. complete all as specified and/ or as directed by Engr-in-Charge.Note :- (i) MCB/MCCBs, Contactors, relay, indicator lamps and selector switch shall be measured and paid seperately as supply only.
51Supply only over load relay 8 to 12.5 Amps for contactor matching series ML 2 & 3 complete all as specified and/ or as directed by Engr-in-Charge.Make : L&T Cat Part No SS91859OOAO or equivalent of Siemens/ Havells.
52Supply only digital type volt meter 0-500 volts complete all as specified and/ or as directed by Engr-in-Charge.Make : L&T Cat Part No WDS301FEV00 or equivalent of Schneider/ AE.
53Supply only digital type Amp meter with suitable CTs 0-300 Amps complete all as specified and/ or as directed by Engr-in-Charge.Make : L&T Cat Part No WDS301FCA00 or equivalent make as approved by GE.
54Supply only indicating lamps RYB as per existing, complete all as specified and/ or as directed by Engr-in-Charge.
55Supply only rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and/ or as directed by Engr-in-Charge.Make : L&T Cat Part No LCKB90S2 or equivalent make as approved by GE.
56Supply only push button switch in RED or GREEN colours, 22mm dia as per existing, complete all as specified and/ or as directed by Engr-in-Charge.
57Supply and fix in replacement of PVC flexible copper multistrand wire of size 6 Sqmm 3 core, complete all as specified and/ or as directed by Engr-in-Charge.Make : RR Kabel/ Havells/ Anchor.
58Supply and fix in replacement of PVC flexible copper multistrand wire of size 6 Sqmm 2 core, complete all as specified and/ or as directed by Engr-in-Charge.Make : RR Kabel/ Havells/ Anchor.
59Supply, installation, testing and commissioning in replacement of LT Panel cubical type indoor floor mounted weather proof totally enclosed (CPRI approved) factory made and made out of 2 mm thick CRCA powder coated sheet and angle iron complete with bus bar of copper of suitable size for capacity 360 Amps 3 Phase and Neutral 415 Volts 50 Hz mounted on epoxy type insulators with PCC flooring and angle iron base frame including space to accomodate 10 Nos DOL starters compitable for monoblock motor and pump of capacity upto 10 HP each on seperate housing having IP-54 protection and conforming to IS-8623 complete all as specified and/ or as directed by the Engr-in-charge including following accessories:-INCOMING(a) MCCB 160 Amps, 4 pole, 35 KA with short circuit and earth fault protection - 01 No. (b) Change over switch open execution type 160 Amp 4 pole - 01 No. OUT GOING(c) MCB TP 32 Amps, 240 Volts, 50 Hz, 'C' curve type- 06 Nos.(d) MCB SPN 63 Amps, 240 Volts, 50 Hz, 'C' curve type - 06 Nos.(e) DOL Starter 3 Phase 415 V compatible for 7.5 HP motor -05 Nos.(f) DOL Starter Single phase compatible for 2 HP motor - 5 Nos.(g) Digital Volt meter with selector switch. (h) Digital Amp meter with selector switch with necessary CT. (j) LED indicating lamp - 11 Sets. Note : (i) The Make of Change over and MCCB considered are Havells/Standard/Indo Asian/HPL.(ii) The rates deemed to be inclusive of suitable size copper wiring/copper strips from Main I/C MCCBs to Change over switch, Change over switch to Main Bus bar and Bus Bar to Outgoing MCCBs complete all as specified and directed. (iii) The design of Panel, make of complete accessories and drawing of the LT Panel should be submitted by the contractor for pre-approval from the Engr-in-Charge before order and execution at site. (iv) All MCCBs / instruments / MCBs /Bus Bar and starters shall be housed in a separate housing with on- off latches in the housing.
60Supply and fix in replacement Control Panel suitable for 4 Lakh Kcal/hr panel board, indoor cubical type, made out of 2.0 mm thick CRCA sheet powder coated for load bearing members for Single side openable and covers, suitable for 3 phase 4 wire 50 cycle 500 Volts system weather and vermin proof, including internal wiring with suitable size copper cable, heat shrinkable sleeves, chromium plated brass cable glands, lugs/thimbles complete all as specified and/ or as directed by Engr-in-Charge including the following parts:- (i) MCB TPN 63 Amp, 415 Volts - 01 No.(ii) Contactors TPN 63 Amp - 01 No.(iii) Over Load relay 8 to 12 Amp - 01 No. (iv) indicator lamps - 4 Nos. (v) Selector Switches - 02 Nos.(v) Voltmeter - 01 No.(vi) Ammeter - 01 No.(vii) Temp Sensor - 01 No.(viii) Temp display - 02 Nos.
61Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core including taking down old unserviceable cable complete all as specified and/ or as directed by Engr-in-Charge.Make : Havells/ Gloster/ Polycab.
62Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth and getting it out for laying of cable in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge.
63Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge.
64Removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and/or as directed by Engr-in-Charge.
65Material and labour for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and/or as directed by Engr-in-Charge. Note : Punned thickness only will be measured and paid for.
66Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 flat size 250mm x 150mm x 50mm, complete all as specified and/ or as directed by Engr-in-Charge.
67Labour only for laying of old serviceable cable covers retrieved from excavation complete all as specified and/ or as directed by Engr-in-Charge.
68Supply and fix in replacement of synthetic rubber insulated mats 2 mm thick of sizes 2m x 1m for voltage upto 11 KV as per IS 15652-2006 (superseding IS 5424), suitable for electrical shock safety complete all as specified and/ or as directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56239958
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.44 Crore
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Chs Plant No Six And Seven And Allied Works At Transit C Under Age E/M-I Of Ge 865 Ews
Basic Detail
Tender No 138WE/L-57/2026-27
Bidding Type Tender
Location
City leh
State Ladakh
Key Dates
Publish Date 30 Jun 2026
Submission Date 28 Jul 2026
Open Date 04 Aug 2026
Finance
Tender Value 1.44 Crore
Tender Fee 1000
EMD 2.19 Lakhs
Exemption Available
Document List
3ed8afea-d44d-46a9-a0da-4fe47e17a079.html
BOQ_868221.xls
TenderL572627.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

3ed8afea-d44d-46a9-a0da-4fe47e17a079.html

xls

BOQ_868221.xls

pdf

TenderL572627.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail