Tender For B.O.Q For Construction/ Remodelling Of Washroom/ Toilet Blocks For Judiciary/ Court Complexes Of Kashmir Division B.W.O Electrification Facility To Public Toilet Block At Munsiff Court Tral.
Tender Value
93825
Estimated cost
Bid Submission
15 Jul 2026
6 days left
EMD
1876
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Construction/ Remodelling Of Washroom/ Toilet Blocks For Judiciary/ Court Complexes Of Kashmir Division B.W.O Electrification Facility To Public Toilet Block At Munsiff Court Tral.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/eq. standard make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit ( incl cost of conduit), with modular switch ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.), modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit. ( incl cost of conduit) |
| 3 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Leiva /ABB Tvisha make make.) |
| 4 | Wiring for lighting circuits/ 6- 10 amp power plugwith 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. ( incl cost of conduit) |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.) |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 7 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 8 | Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.) |
| 9 | Sub Head-2 - Fixtures and Fittings |
| 10 | Supply installation testing and commissioning of 15 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Helonix/Havell/ Wipro make / sample to be approved before installation.. |
| 11 | Supply installation testing and comm. Of 250-300mm sweep exhaust fan steel body of havell /Bajaj/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections. |
| 12 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 13 | 2 + 14 way, Double door |
| 14 | S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABB ./equivalent make as directed by engineer incharge. |
| 15 | a) 6-32 Amp SP MCB |
| 16 | b) 40-63amp DP MCB |
| 17 | S/L , testing and commissioning of PVC XLPE insulated alluminium un armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 18 | c)16 sq.mm 2 core |
| 19 | Supply installation testing and comm. of flood light 30 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell ( JETA QUANTO PLUS MONO 30 W) /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender