Railways Government Departments Closing in 5 days TDR #56236731

Supply Of Flash Back Arrestor (dry type)

Issued by Government Departments · Jamalpur, Bihar
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Jul 2026
5 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamalpur → Bihar
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of flash back arrestor (dry type) , 2.flash back arrestor (dry type) for regulator end of acetylene/lpg lines to prevent flash bac ks in oxy fuel system conforming to en 730/ iso:5175-1/ is:11006/2011,(ra2021),amd-1 of dec.2013 stand ards with flame arrestor (fa) and non-return valve (nrv) and thermal cut off valve (tv) working pressure: 1 .5 bar for acetylene/5.0 bar for lpg. end connections g 3/8 lh to en 560/iso 3253 standards. make: m esser (dgn fuel) or esab (protex ra) or gce (fr-34 r fuel) or weldstar or witt only. note:1) o ffers of oems or their authorised dealers enclosing valid authorised dealership certificat e only will be considered. 2) the suppliers shall send test certificate from govt. authorise d test house. in case of international brand, the test certificate from reputed institute lik e bam, germany is mandatory. 3) the suppliers should have equipments for testing of flash b ack arrestors and calibration. the purchaser has the right to inspect these installations. as per specn. en 730/iso 5175-1/is 11006/2011,(ra-2021), amd-1 of dec 2013 [ warranty period: 30 m onths after the date of delivery ] ] , 1.flash back arrestor(dry type) for regulator end of oxygen lines to prevent flash backs in ox y fuel system conforming to en 730/ iso:5175-1/ is:11006/2011, (ra.-2021), amd.-1 of dec. 2013 standard s with flame arrestor(fa) and non-return valve(nrv) and thermal cut off valve(tv) working pressure:15 bar. end connections g 3/8 rh to en 560/iso 3253 standards. make: messer(dgn oxy) or esab(protex ro) or gce(fr-34 r oxy) or weldstar(fire pro ro) only. note:1) offers of oems or their autho rised dealers enclosing valid authorised dealership certificate only will be considered. 2) the suppliers shall send test certificate from govt.authorised test house. in case of intern ational brand, the test certificate from reputed institute like bam, germany is mandatory. 3 ) the suppliers should have equipments for testing of flash back arrestors and calibration . the purchaser has the right to inspect these installations. specn: :en 730/iso 5175-1/is 1100 6/2011, (ra.-2021), amd.-1 of dec. 2013 [ warranty period: 30 months after the date of delivery ] ]

BOQ

Sl. No.Item Description
12.Flash Back Arrestor (dry type) for regulator end of acetylene/LPG lines to prevent flash bac ks in oxy fuel system conforming to EN 730/ ISO:5175-1/ IS:11006/2011,(RA2021),Amd-1 of Dec.2013 stand ards with flame arrestor (FA) and non-return valve (NRV) and thermal cut off valve (TV) working pressure: 1 .5 bar for acetylene/5.0 bar for LPG. End connections G 3/8" LH TO EN 560/ISO 3253 STANDARDS. MAKE: M ESSER (DGN FUEL) OR ESAB (PROTEX RA) OR GCE (FR-34 R FUEL) OR WELDSTAR OR WITT ONLY. NOTE:1) O FFERS OF OEMs OR THEIR AUTHORISED DEALERS ENCLOSING VALID AUTHORISED DEALERSHIP CERTIFICAT E ONLY WILL BE CONSIDERED. 2) THE SUPPLIERS SHALL SEND TEST CERTIFICATE FROM GOVT. AUTHORISE D TEST HOUSE. IN CASE OF INTERNATIONAL BRAND, THE TEST CERTIFICATE FROM REPUTED INSTITUTE LIK E BAM, GERMANY IS MANDATORY. 3) THE SUPPLIERS SHOULD HAVE EQUIPMENTS FOR TESTING OF FLASH B ACK ARRESTORS AND CALIBRATION. THE PURCHASER HAS THE RIGHT TO INSPECT THESE INSTALLATIONS. as per Specn. EN 730/ISO 5175-1/IS 11006/2011,(RA-2021), Amd-1 of Dec 2013 [ Warranty Period: 30 M onths after the date of delivery ] ]
21.Flash Back Arrestor(dry type) for regulator end of oxygen lines to prevent flash backs in ox y fuel system conforming to En 730/ ISO:5175-1/ IS:11006/2011, (RA.-2021), Amd.-1 of Dec. 2013 standard s with flame arrestor(FA) and non-return valve(NRV) and thermal cut off valve(TV) working pressure:15 bar. End connections G 3/8" RH TO EN 560/ISO 3253 STANDARDS. MAKE: MESSER(DGN OXY) OR ESAB(PROTEX RO) OR GCE(FR-34 R OXY) OR WELDSTAR(FIRE PRO RO) ONLY. NOTE:1) OFFERS OF OEMs OR THEIR AUTHO RISED DEALERS ENCLOSING VALID AUTHORISED DEALERSHIP CERTIFICATE ONLY WILL BE CONSIDERED. 2) THE SUPPLIERS SHALL SEND TEST CERTIFICATE FROM GOVT.AUTHORISED TEST HOUSE. IN CASE OF INTERN ATIONAL BRAND, THE TEST CERTIFICATE FROM REPUTED INSTITUTE LIKE BAM, GERMANY IS MANDATORY. 3 ) THE SUPPLIERS SHOULD HAVE EQUIPMENTS FOR TESTING OF FLASH BACK ARRESTORS AND CALIBRATION . THE PURCHASER HAS THE RIGHT TO INSPECT THESE INSTALLATIONS. SPECN: :EN 730/ISO 5175-1/IS 1100 6/2011, (RA.-2021), Amd.-1 of Dec. 2013" [ Warranty Period: 30 Months after the date of delivery ] ]

AI Tender Summary

OUR REF NO 56236731
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 15-07-2026
Authority
Authority Name Eastern Railways
Work Description Supply Of flash back arrestor (dry type) , 2.flash back arrestor (dry type) for regulator end of acetylene/lpg lines to prevent flash bac ks in oxy fuel system conforming to en 730/ iso:5175-1/ is:11006/2011,(ra2021),amd-1 of dec.2013 stand ards with flame arrestor (fa) and non-return valve (nrv) and thermal cut off valve (tv) working pressure: 1 .5 bar for acetylene/5.0 bar for lpg. end connections g 3/8 lh to en 560/iso 3253 standards. make: m esser (dgn fuel) or esab (protex ra) or gce (fr-34 r fuel) or weldstar or witt only. note:1) o ffers of oems or their authorised dealers enclosing valid authorised dealership certificat e only will be considered. 2) the suppliers shall send test certificate from govt. authorise d test house. in case of international brand, the test certificate from reputed institute lik e bam, germany is mandatory. 3) the suppliers should have equipments for testing of flash b ack arrestors and calibration. the purchaser has the right to inspect these installations. as per specn. en 730/iso 5175-1/is 11006/2011,(ra-2021), amd-1 of dec 2013 [ warranty period: 30 m onths after the date of delivery ] ] , 1.flash back arrestor(dry type) for regulator end of oxygen lines to prevent flash backs in ox y fuel system conforming to en 730/ iso:5175-1/ is:11006/2011, (ra.-2021), amd.-1 of dec. 2013 standard s with flame arrestor(fa) and non-return valve(nrv) and thermal cut off valve(tv) working pressure:15 bar. end connections g 3/8 rh to en 560/iso 3253 standards. make: messer(dgn oxy) or esab(protex ro) or gce(fr-34 r oxy) or weldstar(fire pro ro) only. note:1) offers of oems or their autho rised dealers enclosing valid authorised dealership certificate only will be considered. 2) the suppliers shall send test certificate from govt.authorised test house. in case of intern ational brand, the test certificate from reputed institute like bam, germany is mandatory. 3 ) the suppliers should have equipments for testing of flash back arrestors and calibration . the purchaser has the right to inspect these installations. specn: :en 730/iso 5175-1/is 1100 6/2011, (ra.-2021), amd.-1 of dec. 2013 [ warranty period: 30 months after the date of delivery ] ]
Basic Detail
Tender No 55265217B
Bidding Type Tender
Location
City Jamalpur
State Bihar
Key Dates
Publish Date 26 Jun 2026
Submission Date 15 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
0bf58b4d-8b37-439f-b9ef-0807e33d9beb.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

0bf58b4d-8b37-439f-b9ef-0807e33d9beb.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders