Tender For Supply Installation Testing And Commissioning For Creation Of 25Kva Substations For Newly Constructed Pre-Fab Structure At Korzok Near Tribal Museum On Full Turnkey Basis Under Deposit Work 2026-27.
Tender Value
1000
Estimated cost
Bid Submission
11 Jul 2026
5 days left
EMD
63000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing And Commissioning For Creation Of 25Kva Substations For Newly Constructed Pre-Fab Structure At Korzok Near Tribal Museum On Full Turnkey Basis Under Deposit Work 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | DT ( Supply Part ) |
| 2 | Supply of 25KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 3 | Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 4 | Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 5 | Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 6 | Supply of 50mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25kva DTs |
| 7 | Supply of 9 Mtr. Long Pole,ST-410 SP33) |
| 8 | Supply of 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 9 | Supply of GI Channel/Angle/Flat of sizes including clamps |
| 10 | Supply of Galvinized Nuts and Bolts. |
| 11 | Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 12 | Supply of 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 13 | Supply of LT Distribution Box for 25KVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions |
| 14 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wirecomplete |
| 15 | Supply of Wedge Connecror/PG Clamps |
| 16 | Supply of Danger Plates with Clamps |
| 17 | Supply of GI Barbed Wire for Anti Climbing |
| 18 | Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible) |
| 19 | Supply of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 20 | Supply of Painting of Poles Red Oxide |
| 21 | Supply of Painting of Poles Aluminium Paint |
| 22 | Supply of Sundry items like aluminium lugs, Jumpers, binding Tape, |
| 23 | Installation/Testing /Commissioning Part of Substation. |
| 24 | 25KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 25 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 26 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 27 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 28 | 50mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25kva DTs |
| 29 | 9 Mtr. Long Pole,ST-410 SP33) |
| 30 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 31 | GI Channel/Angle/Flat of sizes including clamps |
| 32 | Galvinized Nuts and Bolts. |
| 33 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 34 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 35 | LT Distribution Box for 25KVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions |
| 36 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wirecomplete |
| 37 | Wedge Connecror/PG Clamps |
| 38 | Danger Plates with Clamps |
| 39 | GI Barbed Wire for Anti Climbing |
| 40 | 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible) |
| 41 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 42 | Painting of Poles Red Oxide |
| 43 | Painting of Poles Aluminium Paint |
| 44 | Sundry items like aluminium lugs, Jumpers, binding Tape, |
| 45 | HT Line Supply Part |
| 46 | 9 Mtr. Long Pole( ST-410 SP33) |
| 47 | GI V cross-arm with top Bracket including clamp(14.631 kg) |
| 48 | GI Channel X-arm including clamps and braces for DP(80kg/DP) |
| 49 | 30 mm² ACSR Conductor |
| 50 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 51 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 52 | Galvinized Nuts and Bolts |
| 53 | Danger Plates with Clamps |
| 54 | Anti-Climbing Device with Clamps |
| 55 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 56 | Red Oxide |
| 57 | Aluminium Paint |
| 58 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 59 | Aluminium Jointing Sleeves |
| 60 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 61 | 8ft Channel with clamp |
| 62 | HT Line Installation/Testing /Commissioning Part |
| 63 | 9 Mtr. Long Pole( ST-410 SP33) |
| 64 | GI V cross-arm with top Bracket including clamp(14.631 kg) |
| 65 | GI Channel X-arm including clamps and braces for DP(80kg/DP) |
| 66 | 30 mm² ACSR Conductor |
| 67 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 68 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 69 | Galvinized Nuts and Bolts |
| 70 | Danger Plates with Clamps |
| 71 | Anti-Climbing Device with Clamps |
| 72 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 73 | Red Oxide |
| 74 | Aluminium Paint |
| 75 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 76 | Aluminium Jointing Sleeves |
| 77 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 78 | 8ft Channel with clamp |
| 79 | LT Line (Supply Part) |
| 80 | 8 Mtr. Long Pole( ST-410 SP15) |
| 81 | GI Channel X Arm (75X40X6mm) 4ft along with GI Clamp, 50X8mm, (4ft=4KG, 1No. Clamp=0.83kg=total weight=8.83 kg) |
| 82 | 30 mm² ACSR Conductor |
| 83 | 16kN Polmer Shacle Insulators |
| 84 | Galvinized Nuts and Bolts |
| 85 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 86 | Red Oxide |
| 87 | Aluminium Paint |
| 88 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum/pole |
| 89 | LT Line (Installation/Testing/Commissioning Part) |
| 90 | 8 Mtr. Long Pole( ST-410 SP15) |
| 91 | GI Channel X Arm (75X40X6mm) 4ft along with GI Clamp, 50X8mm, (4ft=4KG, 1No. Clamp=0.83kg=total weight=8.83 kg) |
| 92 | 30 mm² ACSR Conductor |
| 93 | 16kN Polmer Shacle Insulators |
| 94 | Galvinized Nuts and Bolts |
| 95 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 96 | Red Oxide |
| 97 | Aluminium Paint |
| 98 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum/pole Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysJul 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender