Public Administrative Department Local Bodies Closing in 10 days TDR #56227213

Tender For Urgent Rewinding Of Rotor Including Replacement Of Damaged And Burnt Out Components Of 6 Kv, 360 Kw, Ngef Make Slip Ring Induction Motor For 100 Cusec Capacity Swf Pump Unit. G At Dlps.

Issued by Local Bodies · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Jul 2026
10 days left
EMD
40000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Urgent Rewinding Of Rotor Including Replacement Of Damaged And Burnt Out Components Of 6 Kv, 360 Kw, Ngef Make Slip Ring Induction Motor For 100 Cusec Capacity Swf Pump Unit. G At Dlps.

BOQ

Name of Work:- Urgent rewinding of rotor including replacement of damaged and burnt out components of 6 KV, 360 KW, NGEF make slip ring induction motor for 100 cusec capacity SWF pump unit. G at DLPS.
Sl. No. Item Description
1TOTAL
2Preliminary checking and testing of IR value, insulation leakage of startor, cracks of porcelin bushings, conn. Terminal leads, fibre glass terminal blocks and rotor end ring joints etc, before to detect the fault for 3.3 KV /6.6 KV sq. cage induction Motor.... (Rate as per I & W SCH-2022, ITEM NO. 5.3J.2 PG. 124)
3Taking out carefully the slip ring set of the induction motor by removing the connection from the LRS unit and dismantling the top cover and bearing. (Open Quotation)
4Taking out the 3.3 KV /6.6 KV sq. cage induction Motor from coupling end of 100/150 cusec vertical axial flow propeller pump after dismantling all connection including earthing etc. The motor is to be kept on wooden sleeper at a suitable distance from the floor without damaging the earthing strips and cables etc. as per direction of E.I.C... (Rate as per I & W SCH-2022, ITEM NO. 5.3J.1 PG. 124)
5Dismantling the 6 kv HT motor after tripping the VCB manually & disconnection of the power & control cables after opening bolts and nuts, with the help of overhead crane & proper tools & tackels, and also stacking the HT power cable & Control cable on wooden sleeper at a suitable place as per direction of EIC... (Open Quotation)
6Conducting statutory testing of the slip-ring such as resistance measurement, induction measurement, high pressure test as per relevant IS code of 6 kv motor and complete in all respect with proper care & caution. (Open Quotation)
7Disassembling the motor end and opening of end shield covers, stator coil guard, taking out the rotor from the stator and placing it on the proper arrangement by hoisting mechanism. Thoroughly cleaning of the stator coil insulations, motor bearings, rotor core surface and end ring joints to demoisturishing of the deposited carbon with carbon tetrachloride and heating the stator by silicon heating elemenys periodicaly at a required temperature and covered with terpulin for heat protection along with the arrangement of compressedf air to blow the vapour moisture and to develop its IR value and varnishing with Dr. Beck’s graded CLASS-H varnish including jel epoxy coatying tyo prevent from the moisture Upto 475KW squirrelcage Induction motor of voltage rating 6.6KV... .. (Rate as per I & W SCH-2022, ITEM NO. 5.3J.3.2 PG. 124)
8DRIVING END HOUSINGUnder cut of damaged DE side bearing housing portion, metal deposition on die under cut surface, machining, turning & polishing with proper tolerance according to the size of bearing outer. Work should be completed in all respects up to the satisfaction of E.I.C...... (Rate as per I & W SCH-2022, ITEM NO. 5.3J.8 PG. 125)
9NON DRIVING END HOUSINGUnder cut of damaged N DE side bearing housing portion, metal deposition on the under cut surface, machining, turning & polishing with proper tolerance according to the size of bearing outer. Work should be completed in all respects up to the satisfaction of E, I.C.... (Rate as per I & W SCH-2022, ITEM NO. 5.3J.9 PG. 125)
10DRIVING END SHAFT JOURNALUnder cut of damaged DE s ide bearing journal portion, metal deposition on the under cut surface, machining, turning & polishing with proper tolerance according to the size of bearing bore. Work should be completed in al| respects up to the satisfaction of E.I.C... . (Rate as per I & W SCH-2022, ITEM NO. 5.3J.10 PG. 125)
11NON DRIVING END SHAFT JOURNALUnder cut of damaged DDE side hearing journal portion, metal deposition on the under cut surface, machining, turning & polishing with proper tolerance according to the size of bearing bore. Work shoul d be completed in all respects up to the satisfaction of E.1.C ..... (Rate as per I & W SCH-2022, ITEM NO. 5.3J.11 PG. 125)
12Complete dismantling the slip-ring unit including carbon holder, carbon, slip-ring holder attachment. And also Checking & testing the dismantled 6 KV HT slip Sring motor for its stud & opening all insulation like glass tape, insulating packing etc. as per diretion of E.I.C. (Open Quotation)
13Repairing & servicing of motor terminals HT bushing & terminal box. (Open Quotation).
14To remove the rotor copper bars it has to be straighten, 2 copper bars in each slot … (Open Quotation)
15Complete removal of damaged insulations, copper bars etc from the rotor with care & caution to avoid any damages as per the direction of EIC… (Open Quotation).
16Rotor core Surface to be cleaned washed & dressed by proper way using CTC detergent. A light coat varnish to be applied on the rotor core after complete dressing and proper baking. and laminated wedges to be inserted in the slot portion. Overhang to be properly braced as per direction of EIC.... (Open Quotation).
17Bending of copper bars, 2 copper bars in each slot to fix it in the rotor groove as per requirement… (Open Quotation).
18Complete rewinding of rotor by 99% grade electrolytic copper bars along with socketing 195 numbers of copper strips in both ends & wires incl supply of insulation paper, nomex paper etc. … (Open Quotation).
19Entire rotor core & winding assembly to be baked and varnished by using Dr. Beck's makes varnish. Thereafter, final coating of varnish to be applied for anti-coated moisture protecting tropical paint (Dr. Beck's paint). and Heat treatment of rotor by inserting it inside a heat chmaber for 72 hours... (Open Quotation).
20S & F of 4m. Length of 95 sq.mm. /3.3 KV/6.6 KV grade H.T. glass copper leads with end finishing by 95 sq.mm. heavy duty dowells copper lug at STAR conn. Terminal leads including replacement of glass fibre terminal block and SS bolts etc. (I&W SCH-2022, ITEM NO- 5.3.J.4, P-125)
21Properly cheeking, testing of developed IR value of the motor, leakage factor of bushings, terminal shortings, IR value of G.F.blocks etc. after the necessary repairing works for 3.3 KV /6.6 KV sq. cage induction Motor… (I&W SCH-2022, ITEM NO- 5.3.J.8, P-125)
22Repairing of slip ring by first remove all the insulated sheath of Ring unit and gradually open out individually from its base. Then clean the slip-ring base unit thoroughly by heating arrangement and open out the damaged insulation layer upto the fully bare condition. After the metalizing of the damaged portion of the base unit of slip-ring it is to be sent to machine shop for alignment and smoothing of the outer & inner surface along with making key slots for making the locking arrangement with the motor shaft. After proper Machining & polishing the outer & inner surface of slip-ring unit and lapping it with 6 mm insulation sheet to its base and casting it whole with the insulation to insulate each phase of the rotor properly. After completion of insulation arrangement, slip-ring unit will be fit and fix its base individually maintain proper alignment of each ring as per motor design. The rings will be locked individually to its base. Finally insulate the whole unit by Dr Beck varnish to insulate from dirt & dust before re-alignment of complete slip-ring unit assembly for the last time... (Open Quotation).
23Supply , fitting & fixing of carbon brush with pig tail (grade M16E) & holder as per required size & shape of existing for the 6.6 KV rated motor and complete in all respect as per direction of EIC. … (Open Quotation).
24Refitting the 6.6 KV Slip ring set over the motor with all its necessary coupling accessories to its position including fifling fixing with bearing housing, non-reversable ratchet unit and pump shaft with proper tolerance and clearance and reconnection of terminal points of the completion of necessary work and satisfactory 2 hours trial run of the pump as perdirection of E.I.C. ... (Open Quotation).
25Manufacture and supply of Motor coupling with pump as per specification, drawing or existing one with proper tolerance and finish as per direction. Of EIC along with Coupling Pin (Mat. CS IS1570-40C8 HOT RLD) in motor coupling…. (Open Quotation).
26DYNAMIC BALANCINGTrueness check ing & dynamic balancing of rotor. (Certificate is to be Pro vided to Authority)… (I&W SCH-2022, ITEM NO- 5.3.J.12, P-125)
27Structural M.S Bolt / Nut / Washer (Hot dipped Galvanised)… (I&W SCH-2022, ITEM NO- 22, P-68)
28Reassembling the 3.3 KV /6.6 KV sq. cage induction Motor including placing the rotor into the stator, refixing the coil guard, prefixing the motor covers, terminal leads, terminal blocks, cable entry box, terminal box aftetr completion of repairing works. Upto 475KW squirrelcage Induction motor of voltage rating 6.6KV.. (I&W SCH-2022, ITEM NO- 5.3.J.5.2, P-125)
29Painting with best quality epoxy primer & epoxy enamel paint (two coat ) of approved make and brand after necessary scapping cleaning etc. including smoothening surface by sand papering etc… (Open Quotation).
30Necessary checking, testing & calibration of following relay (for 6 KV Panel) Each relay set consists of following relays MICOM P110 /122/127/ 1 NO. CGL 14N/C- 1 NO VAX31 - 1 NO, VAA-33-1NO VAMP-31 - 1 NO, VAJH-13-1NO, and For motor protection (6 kv motor): Each relay set consists of following relays C.T.M.M. Motor protection all relay and 1 NO. VAJH 13 - 1 NO.... (Open Quotation).
31Refitting the pump motor (3.3 KV /6.6 KV sq. cage induction Motor) set with all its necessary coupling accessories to its original position including fitting fixing with bearing housing, non-reversable ratched unit and pump shaft with proper tolerance and clearance and reconnection of terminal points of the completion of necessary work and satisfactory 2 hours trial run of the pump motor set as per direction of E.I.C.... (Open Quotation).
32To & from transportation of motor from work site to the repairer / servicer work shop and vice-versa including loading and unloading with proper care & as per direction of EIC…. (Open Quotation).
33Hydra hire Charges … (Open Quotation). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56227213
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 20-07-2026
Authority
Authority Name Kolkata Municipal Corporation
Work Description Tender for Urgent Rewinding Of Rotor Including Replacement Of Damaged And Burnt Out Components Of 6 Kv, 360 Kw, Ngef Make Slip Ring Induction Motor For 100 Cusec Capacity Swf Pump Unit. G At Dlps.
Basic Detail
Tender No KMC/S_D/DLPS/MG/26-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 30 Jun 2026
Submission Date 20 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 40000
Exemption Not Available
Document List
7de95513-115d-4036-912a-50228c174682.html
BOQ_2529382.xls
FORM.pdf
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

7de95513-115d-4036-912a-50228c174682.html

xls

BOQ_2529382.xls

pdf

FORM.pdf

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail