Tender For Repair Of Pump House & Internal Wiring At Naridiara Kaliaganj Hdtw (Ml No 249) Under Purbo Saidpur Mouza, Jl No 72, Plot No 1033 At Manikchak Block, Malda.
Tender Value
2.19 Lakhs
Estimated cost
Bid Submission
08 Jul 2026
0 days left
EMD
4400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Maldah → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Of Pump House & Internal Wiring At Naridiara Kaliaganj Hdtw (Ml No 249) Under Purbo Saidpur Mouza, Jl No 72, Plot No 1033 At Manikchak Block, Malda.
BOQ
| Sl. No. | Item Description |
| 1 | REPAIRING OF PUMP HOUSE |
| 2 | Stripping off worn out plaster and raking out joints of walls, celings etc. up to any height and in any floor including removing rubbish and stacking anywhere within the compound as directed. |
| 3 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m in ground floor including roof. (a) up to 150 mm. thick |
| 4 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof |
| 5 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.. a) In ground floor including roof. |
| 6 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 7 | Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth |
| 8 | Brick work with 1st class bricks in cement mortar (1:6) (a) In Super structure |
| 9 | Cement concrete with graded stone ballast (40 mm size) excluding shuttering in ground floor. (A) Pakur Variety a) 1:3:6 proportion |
| 10 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood plank of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (a) 25 mmto 30 mm thick wooden shuttering as per decision and direction of Engineer-in Charge. |
| 11 | Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial strightening and removal of loose rust (if necessary), cutting requisite length, hooking and binding to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor /upto 4 m. ( i ) Tor steel/Mild steel. II. JSW/JSPL/SHYAM/SRMB/ BMASL/ELECROSTEEL/SSL |
| 12 | Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips ( 20 mm down ) excluding shuttering and reinforcement. if any,in ground floor. as per IS 456-2000. a) Pakur Variety (Rate Analysis) |
| 13 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above |
| 14 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary (ground floor)(b) With (1:4) cement mortar. (ii) 15 mm thick plaster |
| 15 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. |
| 16 | Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners and including application of cement slurry before flooring works, using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm thick topping (High polishing grinding on this item is not permited) with ordinary cement. (iii) 25 mm thick |
| 17 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC(a) One Coatii) Solvent based interior grade Acrylic Primer(a) One Coat |
| 18 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat |
| 19 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat) |
| 20 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 21 | Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smoothening surface by sand papering etc. B) On Steel or other Metal surface |
| 22 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coat (with any shade except white) |
| 23 | Painting with ready mixed Black Japan of approved make and brand including smoothening surface for pipe. (PWD Schedule, Page No - 201 , Item No - 5(b) |
| 24 | Supplying fitting fixing MS Joist 125 mm x 75 mm size with RCC pillars at the roof of pump house for fitting device of pump until including hoisting and lifting MS structure |
| 25 | Painting block letters or digits in Black Japan or any approved paint as per direction.[P.W.D Schedule page no.268, item no 17]. h) Size above 15 cm. and upto 20 cm. |
| 26 | g) Size above 12.5 cm. and upto 15 cm. |
| 27 | INTERNAL WIRING OF PUMP HOUSE |
| 28 | Fixing only Sheet Steel Main Switch(Rewirwable type)/ Change over on Flat Iron Frame/Angle Iron Frame on wall ( including all materials except equipment ) i) For 100 Amp. Main Switch |
| 29 | Fixing only starters (for motor control) on flat angle iron frame on wall. b) For star delta starter 22.5 HP to 25 HP. |
| 30 | Fixing only Voltmeter/Ammeter/Energy meter with screws & other fixing materials incl. making necessary holes and connections |
| 31 | a) Voltmeter |
| 32 | b) Ammmeter |
| 33 | Supplying and fixing 240 volt, 15/16 Amps. DP. Sheet Steel Main Switch on flat iron frame on wall. (Havells make.) |
| 34 | Earthing with 65 mm. dia G.I. pipe ( TATA medium) into 3.0 mts . Long and 1 no 50mmx6mm galvanized ( hot deep) steel strip ( 4 metre long) , 20mm dia x125mm long galvized bolt , double nuts double washers including finishing both ends by making holes etc. and S& F 65 mm dia G.I. pipe ( ISI medium) protection ( 3mts long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 mts.(a) For soft soil |
| 35 | Finishing the end of XLPE/P.V.C.armoured cables by crimping method including supplying & fixing soldering socket,(dowels make), tapes , anti corrosive pastes & joining materials.(a) 3½ core 25 Sqmm. |
| 36 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface]Outside room - 1 light point Pump Room - 2 light point + 1 fan point Varandah - 1 light point (a) average run 6 mts. |
| 37 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. |
| 38 | Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set. |
| 39 | Add extra charge @ 5.0 % for Malda District as per preface item A - iv of Electrical wiring volume - I of 2017. |
| 40 | Meter loop connection with 1.1 K.v. Gr. 3% core 14 core 10 Sqmm to 50 Sq mm. p.v.C.! XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter toincomming TPN Main Switch1Terminal .(Brand:Gloster/Havells/Finolex)For HDTW/MDTW/MINI RLI Scheme i) 25 Sqmm 3% Core Copper Cable |
| 41 | ADD GST @ 18% |
| 42 | Add CESS @ 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents