Bids Are invited for Custom Bid For Services - R-1715 Dismantling Shifting Of Smcp Fldc Fmg Electrical Equipments For Mining Operation At Nalco Mines - Dismantling And Shifting Of Large Size Electrical Panels(As Per The List Attached Below This Boq Sheet), Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge. , Dismantling & Shifting Of Medium Size Electrical Panels(As Per The List Attached Below This Boq Sheet), Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge , Dismantling & Shifting Of Bch Panel Make 415 V 1000A Panel 1200(L)X2400(H)X800(D),Approx.,Weight:700Kg(Approx.),Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge. , Dismantling & Shifting Of Hitachi Ups Panels,2X5kva Pr Ups System,Make:Hi-Rel,Size:1830(L)X1600(H)X750(D),Weight:1000Kg(Approx.),Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge , Dismantling & Shifting Of Emerson Ups 2X5kva Pr Ups System,Make:Emerson,Size:600(L)X800(H)X750(D),Weight:600Kg(Approx.), Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge , Dismantling & Shifting Of 110 V Charger Battery Banks With 110 No. Of Battery Of 2 V Cells,Size:2000(L)X1000(H)X450(D),Weight:1008Kg(Approx.), Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge , Dismantling & Shifting Of Ups Battery Banks With 110 No. Of Battery Of 2 V Cells,Cells,Size:2000(L)X1000(H)X450(D),Weight:1008Kg(Approx.), Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge , Dismantling & Shifting Of Smcp Electromagnet Panel,Make:Cg,Size:1000(L)X1500(H)X400(D),Weight:600Kg(Approx.), Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge , Dismantling & Shifting Of 110 V Dcdb Panel Make:Chhabi,Size:1500(L)X2000(H)X500(D),Weight:500Kg(Approx.), Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge , Dismantling & Shifting Of Ht Panels And Breakers (33 Kv / 6.6 Kv) (As Per The List Attached Below This Boq Sheet)Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge , Dismantling & Shifting Of 33Kv Pt & Icog Panel ,Make:Cg,Size:1400(L)X2275(H)X3215(D),Weight:3T(Approx.), Including Proper Isolation, Safe Dismantling, Lifting, Loading, Unloading, Transportation, Stacking, And Preservation At The Designated Location, Complete As Directed By The Engineer-In-Charge
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Dismantling and shifting of Large Size Electrical Panels(as per the list attached below this BOQ sheet), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge. | Dismantling and shifting of Large Size Electrical Panels(as per the list attached below this BOQ sheet), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge. |
| 2 | Dismantling & shifting of Medium Size Electrical Panels(as per the list attached below this BOQ sheet), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & shifting of Medium Size Electrical Panels(as per the list attached below this BOQ sheet), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
| 3 | Dismantling & shifting of BCH Panel make 415 V 1000A PANEL 1200(L)X2400(H)X800(D),Approx.,Weight:700kg(Approx.),including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge. | Dismantling & shifting of BCH Panel make 415 V 1000A PANEL 1200(L)X2400(H)X800(D),Approx.,Weight:700kg(Approx.),including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge. |
| 4 | Dismantling & shifting of HITACHI UPS PANELS,2x5KVA PR ups system,Make:hi-rel,Size:1830(L)X1600(H)X750(D),Weight:1000kg(Approx.),including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & shifting of HITACHI UPS PANELS,2x5KVA PR ups system,Make:hi-rel,Size:1830(L)X1600(H)X750(D),Weight:1000kg(Approx.),including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
| 5 | Dismantling & shifting of EMERSON UPS 2x5KVA PR ups system,Make:Emerson,Size:600(L)X800(H)X750(D),Weight:600kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & shifting of EMERSON UPS 2x5KVA PR ups system,Make:Emerson,Size:600(L)X800(H)X750(D),Weight:600kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
| 6 | Dismantling & shifting of 110 V charger BATTERY BANKS with 110 no. of battery of 2 V cells,Size:2000(L)X1000(H)X450(D),Weight:1008kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & shifting of 110 V charger BATTERY BANKS with 110 no. of battery of 2 V cells,Size:2000(L)X1000(H)X450(D),Weight:1008kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
| 7 | Dismantling & shifting of UPS BATTERY BANKS with 110 no. of battery of 2 V cells,cells,Size:2000(L)X1000(H)X450(D),Weight:1008kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & shifting of UPS BATTERY BANKS with 110 no. of battery of 2 V cells,cells,Size:2000(L)X1000(H)X450(D),Weight:1008kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
| 8 | Dismantling & shifting of SMCP Electromagnet panel,Make:CG,Size:1000(L)X1500(H)X400(D),Weight:600kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & shifting of SMCP Electromagnet panel,Make:CG,Size:1000(L)X1500(H)X400(D),Weight:600kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
| 9 | Dismantling & shifting of 110 V DCDB PANEL Make:CHHABI,Size:1500(L)X2000(H)X500(D),Weight:500kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & shifting of 110 V DCDB PANEL Make:CHHABI,Size:1500(L)X2000(H)X500(D),Weight:500kg(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
| 10 | Dismantling & Shifting of HT Panels and Breakers (33 kV / 6.6 kV) (as per the list attached below this BOQ sheet)including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & Shifting of HT Panels and Breakers (33 kV / 6.6 kV) (as per the list attached below this BOQ sheet)including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
| 11 | Dismantling & shifting of 33KV PT & ICOG panel ,Make:CG,Size:1400(L)X2275(H)X3215(D),Weight:3T(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge | Dismantling & shifting of 33KV PT & ICOG panel ,Make:CG,Size:1400(L)X2275(H)X3215(D),Weight:3T(Approx.), including proper isolation, safe dismantling, lifting, loading, unloading, transportation, stacking, and preservation at the designated location, complete as directed by the Engineer-in-Charge |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender