Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation, Work Of Special Maintenance And Repairing Of 33 Kv, 11 Kv And Lt Lines Damaged Due To Heavy Storm At
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Commercial; Electrical System Or Installation, Work Of Special Maintenance And Repairing Of 33 Kv, 11 Kv And Lt Lines Damaged Due To Heavy Storm At 33/11 Kv Sub-Station,.. - Safe Cartage Of 8.5 Mtr. Long Pcc Poles , Safe Cartage Of 11 Mtr. Long St Poles , Safe Cartage Of Line Material , Erection Of Newly Erected 8.5 Mtr. Long Pcc Poles As Single Support Structure, Including Complete Ht/Lt Fittings As Per Direction Of Engineer Incharge/Resspo Manual. , Erection Of Newly Erected 11 Mtr. Long St Poles As Single Pole Structure, Including Complete Ht/Lt Fittings As Per Direction Of Engineer Incharge/Resspo Manual. , Erection Of Newly Erected 8.5 Mtr. Long Pcc Poles As Double Pole Structure, Including Complete Ht/Lt Fittings As Per Direction Of Engineer Incharge/Resspo Manual. , Erection Of Newly Erected 11 Mtr. Long St Poles As Double Pole Structure, Including Complete Ht/Lt Fittings As Per Direction Of Engineer Incharge/Resspo Manual. , Concreting/Grouting Of Newly Erected 8.5 Mtr. Long Pcc Poles As Single Support/Double Pole Structures. The Support Shall Be Grouted With Cement, Sand And Brick Ballast/Stone Ballast In Ratio 1:4:8 (0.285 Cu. Mtr. Each), Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast/Stone Ballast, Stone Pad Etc. As Per Actual Site Requirement & Direction Of Enginner Incharge. , Concreting/Grouting Of Newly Erected 11 Mtr. Long St Poles As Single Support/Double Pole Structures. The Support Shall Be Grouted With Cement, Sand And Brick Ballast/Stone Ballast In Ratio 1:4:8 (0.285 Cu. Mtr. Each), Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast/Stone Ballast, Stone Pad Etc. As Per Actual Site Requirement & Direction Of Enginner Incharge. , Erection And Grouting Of Stay Set Including The Work Of Nozelling Etc. As Per Resspo Manual And Also Including The Cost Of All Grouting Material. , Fixing Of Earthing Rod As Per Direction Of Supervising Engineer/Resspo Manual. Including The Cost Of Labour, T&P Etc. Required For Proper Completion Of Work. , Laying, Sagging, Stringing, Binding And Jumpering Of New Acsr Weasel/Dog Conductor On The Erected Poles In 11 Kv Ht/Lt Lines Also Providing In-Place Of Damaged/Misplace Conductor Due To Heavy Storm. , Laying, Stringing, Binding And Termination Etc. Of Abc Cable Of Various Size On The Erected Poles As Per Direction Of Supervising Engineer/Resspo Manual. , Re-Sagging Of Loose Conductor Of 33 Kv Lines At Various Places. , Re-Sagging Of Loose Conductor Of 11 Kv Ht Lines At Various Places. , Re-Sagging Of Loose Conductor Of Lt Lines At Various Places. , Dismentling & Removal Of Existing/Erected Old & Damaged Pcc/Stp/Joist/Rail Poles As Single Pole Structure With Its Accessories. , Dismentling & Removal Of Existing/Erected Old & Damaged Pcc/Stp/Joist/Rail Poles As Double Pole Structure With Its Accessories. , Carriage Of Damaged/Rusted St/Rail/Joist Poles From Work Site To Esc. , Replacement Of Damaged/Misplace Pin Insulator With Pin 33 Kv/11 Kv , Replacement Of Damaged/Misplace V Type Cross Arm 33 Kv/11 Kv , Replacement Of Damaged/Misplace Disc Insulator With Fitting 33 Kv/11 Kv , Guarding With Fitting Of All Accessories As Per Resspo Manual. , Dismentling & Removal Of Damaged Weasel/Dog Conductor With Its Accessories Due To Heavy Storm And Also Cartage Of Old/Damaged & Scrap Line Material From Work Site To Store Centre/Je(S). , Straightening Of Tilted Single Support As 8.5/11.0 Mtr. Long Pcc/St Pole At Various Places. , Chopping Of Tree Branches Coming In The Vicinity Of The Lines During The Execution Of Above Work. , Fixing Of T-Off Channel With Fitting Of All Accessories As Per Resspo Manual. , Supply & Fixing Of Nut-Bolts With Warsher Of Suitable Sizes As Per Resspo Manual. , Note: Any Quantity Of Item From Sl No. 1 To Sl No. 28 May Vary To Any Limit Within The Financial Value Of Agreement Against This Tender.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Safe cartage of 8.5 Mtr. long PCC poles | Safe cartage of 8.5 Mtr. long PCC poles |
| 2 | Safe cartage of 11 Mtr. long ST poles | Safe cartage of 11 Mtr. long ST poles |
| 3 | Safe cartage of line material | Safe cartage of line material |
| 4 | Erection of newly erected 8.5 Mtr. long PCC poles as single support structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. | Erection of newly erected 8.5 Mtr. long PCC poles as single support structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. |
| 5 | Erection of newly erected 11 Mtr. long ST poles as single pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. | Erection of newly erected 11 Mtr. long ST poles as single pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. |
| 6 | Erection of newly erected 8.5 Mtr. long PCC poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. | Erection of newly erected 8.5 Mtr. long PCC poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. |
| 7 | Erection of newly erected 11 Mtr. long ST poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. | Erection of newly erected 11 Mtr. long ST poles as double pole structure, including complete HT/LT fittings as per direction of Engineer incharge/RESSPO manual. |
| 8 | Concreting/Grouting of newly erected 8.5 Mtr. long PCC poles as single support/double pole structures. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge. | Concreting/Grouting of newly erected 8.5 Mtr. long PCC poles as single support/double pole structures. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge. |
| 9 | Concreting/Grouting of newly erected 11 Mtr. long ST poles as single support/double pole structures. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge. | Concreting/Grouting of newly erected 11 Mtr. long ST poles as single support/double pole structures. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge. |
| 10 | Erection and grouting of stay set including the work of nozelling etc. as per RESSPO manual and also including the cost of all grouting material. | Erection and grouting of stay set including the work of nozelling etc. as per RESSPO manual and also including the cost of all grouting material. |
| 11 | Fixing of earthing rod as per direction of supervising engineer/RESSPO manual. including the cost of labour, T&P etc. required for proper completion of work. | Fixing of earthing rod as per direction of supervising engineer/RESSPO manual. including the cost of labour, T&P etc. required for proper completion of work. |
| 12 | Laying, sagging, stringing, binding and jumpering of new ACSR Weasel/Dog Conductor on the erected poles in 11 KV HT/LT lines also providing in-place of damaged/misplace conductor due to heavy storm. | Laying, sagging, stringing, binding and jumpering of new ACSR Weasel/Dog Conductor on the erected poles in 11 KV HT/LT lines also providing in-place of damaged/misplace conductor due to heavy storm. |
| 13 | Laying, stringing, binding and termination etc. of ABC Cable of various size on the erected poles as per direction of supervising engineer/RESSPO manual. | Laying, stringing, binding and termination etc. of ABC Cable of various size on the erected poles as per direction of supervising engineer/RESSPO manual. |
| 14 | Re-sagging of loose conductor of 33 KV lines at various places. | Re-sagging of loose conductor of 33 KV lines at various places. |
| 15 | Re-sagging of loose conductor of 11 KV HT lines at various places. | Re-sagging of loose conductor of 11 KV HT lines at various places. |
| 16 | Re-sagging of loose conductor of LT lines at various places. | Re-sagging of loose conductor of LT lines at various places. |
| 17 | Dismentling & removal of existing/erected old & damaged PCC/STP/Joist/Rail Poles as single pole structure with its accessories. | Dismentling & removal of existing/erected old & damaged PCC/STP/Joist/Rail Poles as single pole structure with its accessories. |
| 18 | Dismentling & removal of existing/erected old & damaged PCC/STP/Joist/Rail Poles as double pole structure with its accessories. | Dismentling & removal of existing/erected old & damaged PCC/STP/Joist/Rail Poles as double pole structure with its accessories. |
| 19 | Carriage of damaged/rusted ST/Rail/Joist Poles from work site to ESC. | Carriage of damaged/rusted ST/Rail/Joist Poles from work site to ESC. |
| 20 | Replacement of damaged/misplace pin insulator with pin 33 KV/11 KV | Replacement of damaged/misplace pin insulator with pin 33 KV/11 KV |
| 21 | Replacement of damaged/misplace \\"V\\" Type Cross Arm 33 KV/11 KV | Replacement of damaged/misplace \\"V\\" Type Cross Arm 33 KV/11 KV |
| 22 | Replacement of damaged/misplace disc insulator with fitting 33 KV/11 KV | Replacement of damaged/misplace disc insulator with fitting 33 KV/11 KV |
| 23 | Guarding with fitting of all accessories as per RESSPO manual. | Guarding with fitting of all accessories as per RESSPO manual. |
| 24 | Dismentling & removal of damaged weasel/dog conductor with its accessories due to heavy storm and also cartage of old/damaged & scrap line material from work site to store centre/JE(s). | Dismentling & removal of damaged weasel/dog conductor with its accessories due to heavy storm and also cartage of old/damaged & scrap line material from work site to store centre/JE(s). |
| 25 | Straightening of tilted single support as 8.5/11.0 Mtr. Long PCC/ST Pole at various places. | Straightening of tilted single support as 8.5/11.0 Mtr. Long PCC/ST Pole at various places. |
| 26 | Chopping of Tree Branches coming in the vicinity of the lines during the execution of above work. | Chopping of Tree Branches coming in the vicinity of the lines during the execution of above work. |
| 27 | Fixing of T-Off Channel with fitting of all accessories as per RESSPO manual. | Fixing of T-Off Channel with fitting of all accessories as per RESSPO manual. |
| 28 | Supply & Fixing of Nut-Bolts with warsher of suitable sizes as per RESSPO manual. | Supply & Fixing of Nut-Bolts with warsher of suitable sizes as per RESSPO manual. |
| 29 | Note: Any quantity of item from sl no. 1 to sl no. 28 may vary to any limit within the financial value of agreement against this tender. | Note: Any quantity of item from sl no. 1 to sl no. 28 may vary to any limit within the financial value of agreement against this tender. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender