Tender For Construction Of Acr At Middle School Showgund_Malwan Adv Cost Rs. 10.41 Lacs Incld 18% Gst
Tender Overview
Project Description
Tender for Construction Of Acr At Middle School Showgund_Malwan Adv Cost Rs. 10.41 Lacs Incld 18% Gst
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Jul-2026 | Bid Submission date Extended | Date | 16-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : i/c back filling of same inside plinth and clearance of site after completion of work complete. |
| 2 | Providing and laying stone soling by way of Nallah boulders size on level ( Hand packed ) Watering ,ramming complete below foundation & rooms including carriage of material. |
| 3 | Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.) |
| 4 | P/L in position specified grade of reinforced cement cencrete excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. 1:1.5:3 graded stone agg. 20mm nominal size |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:(1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)) |
| 7 | Centring and shuttering of kit ply including proping, strutting & removal of the same up to plinth level |
| 8 | Centring and shuttering of kit ply including proping, strutting & removal of the same for suspended floors etc |
| 9 | Centring and shuttering of kit ply including proping, strutting etc & removal of the same for Suspended floors, roofs, landings, balconies and access platforms |
| 10 | Brick work with FPS bricks of class designation 75 in foundtion & plinth in cement mortar 1:6 (1 cement, 6 coarse sand)including extra over brick work in superstructure above plinth level upto floor five level including curing. |
| 11 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position Imported wood |
| 12 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, includingfixing of 3.50mm thick float glass panes complete and excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.30mm thick imported wood. |
| 13 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.30 mm thick imported wood. |
| 14 | Providing & fixing decorative plywood B/S decorative veneer (Type 1) confirming to IS 1328 BWR type |
| 15 | Providing & fixing of 40x5mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts &wooden plugs and embedding in cement conc block 30x10x5cm 1:3:6mix (1cement:3coarse sand:6 graded st agg)20mm nominal size |
| 16 | 12mm Cement Plaster on the rough side of single or half brick wall of mix 1:6(1 cement:6 fine sand) including cost of all material,skyfoulding for outside & curing. |
| 17 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 18 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600mm |
| 19 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 20 | Distempering with 1st quality acrylic distemper (ready made) of approved manufacturers and of required shade and color complete. Two or more coats on new work including cement primer coat over wall putty surface. |
| 21 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 22 | Applying priming coat with ready mixed Pink or grey primer of approved brand and manufacture on WOOD work (hard or soft wood) |
| 23 | Painting with synthetic enamel paint of app. Brand & manufacture to give an even shade 2 or more coats on new work |
| 24 | Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (Thermo-mechanically treated bars) |
| 25 | Structural steel welded in built up sections trusses and framed work incld cutting hoisting fixing in positon and applying a priminng coat of approved steel primer all complete i/c soffits / eaves board |
| 26 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 27 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coatedthickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 28 | Providing hardware items |
| 29 | L Drop |
| 30 | Towerbolts 100 mm |
| 31 | Handles 150 mm |
| 32 | Handles 100 mm |
| 33 | Hooks |
| 34 | Providing /fixing 25 mm dia pvc condute pipes,junctions,concealed boxes,fan boxes etc for electric fittings includng embedding all complete job |
| 35 | Carriage of materails By Mech.Transport, from source to site of work |
| 36 | Stone agg. for an avg lead of 15 km |
| 37 | Sand for an avg lead of 15km |
| 38 | Bricks for an avg lead of 10 km Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender