| Sl. No. | Item Description |
| 1 | Repairs to plaster inpatches of 2.5 sq.m. andunder including cutting thepatch in proper shape andpreparing and plasteringthe surface of the wallscomplete includingdisposal of rubbish to thedumping ground within50m lead.;With cementmortar 1:4 (1 cement : 4fine sand) |
| 2 | Demolishing R.C.C. workincluding stacking of steelbars & disposal ofunserviceable within 50mts. lead. |
| 3 | Dismantling the tile workin floors and roofs laid incement including stackingof materials within 50meters lead for thicknessof tiles 10mm to 25mm. |
| 4 | Removing old loosebottom or side cover ofRCC slab beam columnsetc. rubbing surface ofconcrete steel using wirebrush and applying 2 coatsof Alkaline rust convertingprimer (Feovert) after awaiting time of 6 hrsbetween coats and thenapplying another anticorrosive protectivecoating system ) forreinforcement bars (IPNet-RB) Conforms to IS-2770Part-1 (Pull out Test)ASTM-3963-86 (Adhesion Test) and then applyingconcrete penetratingcorrosion inhibitor (EPCOKP100)and applyingbonding new to oldconcrete (Epibond)Conforms to ASTM-C-882-87 and plastering on thefresh bond coat withPolymer Modified Mortar(Monobond) with 20mm C.M 1:3 and finishing coat of6mm C.P 1:3 (1 Cement :3 Sand ) incl. cost oftransport etc. as per dir ofEIC. All the chemicals willbe of Krishna ConchemProducts Pvt. Ltd. orEquivalent. |
| 5 | FRP (Fiber ReinforcedPolymer) FramesManufacture Supply andInstallation (with anchorfastener) of EPEE orequivalent Goan makeFRP (Fiber ReinforcedPolymer) Frame of crosssection as per optionsbelow with right anglejoint and FRP (FiberReinforced Polymer)laminate made from 450grams per sq.mts (gsm)chop strand glass fiber(matt) and unsaturatedpolyester resin withviscosity range of 400/450centipoises per second(cps). The core of framewould be filled withseasoned wood as infill material. The slot of framefor door resting will be ofsuitable width so as to takespecified thickness door..The frame will be waterproof as well as mild acid/alkali resistantmanufactured in an ISO9001- 2015 certifiedcompany.;Specified Cross Section;3” x 2” |
| 6 | Single Colour Foam CoreFRP (Fiber ReinforcedPolymer) Door ShutterManufacture Supply andInstallation (including accessories as mentionedbelow) of EPEE orequivalent Goan makeFRP (Fiber ReinforcedPolymer) door shutter ofspecified thickness as peroptions below by usingtray system with seasonedhard wood moisture lessthan 17% wood styles forTop rail and lock rails.FRP (Fiber ReinforcedPolymer) laminate madeup of 450 grams per sq.mts(gsm) chop strand matt andunsaturated polyester resinwith viscosity range of 400/450 centipoises persecond (cps) . The core ofshutter will be filled asspecified (Expanded Polystyrene Foam /Polyurethane Foam (EPS/PU) Foam). The shutter tobe of single colour & waterproof as well as mild acid /alkali resistantmanufactured using RVTIFAC (R V EngineeringCollege Bangalore &Technology InformationForecasting & AssessmentCouncil) technology in linewith IS 13034 1990 testStandard in an ISO 9001 –2015 certified factory.Accessories: i) S. S.Hinges 4” - 3 Nos ii) S. S.Latch - 1 No iii) TowerBolt 5” - 2 Nos iv) Handle5” - 2 Nos Note: For 35 &40mm thickness shuttersonly frames of 5 x 2 ½ Cross section frames to beused.;Shutter Thickness;30mm |
| 7 | Providing and and layingantiskid floor tiles 12 x 12upto 16 x 16 in of JohnsonSomany Kajaria (thicknessto be specified by themanufacturer) of 1stquality conforming to IS:15622 of approved make inshades as specified laid on20 mm thick cementmortar 1:4 (1 Cement : 4Coarse sand) including pointing the joints withwhite cement andmatching pigment etc.complete;Light Shades |
| 8 | Providing and fixinganodised aluminiumshutters in accordance withthe specification annexedherewith includingtransportation, scaffoldingand handling etc. completeas per direction of theEngineer-in-charge: windows with twosliding shutters using 18mm series shutters section.;Plain glass |
| 9 | Extra for powder coatingwith pure polyester powderof shade of required colouron the aluminium section |
| 10 | Providing water proofingtreatment over the new R.C.C. roofs terrace toilet byspreading cement slurryover the R.C.C. slab andlaying of 10cms. Averagelaterite stone ballast cobawith the necessary gradientfor easy flow of rain waterand the coba in coveredwith damp proof ofHindustan water proofingco. Or equivalent jointlesswater proofing plaster ofmix 1:3 ( 1 cement : 3 findsand) finished smooth withwooden trowel with falsemarking of 30 cms square.The vertical surface of theadjoining walls are to betreated upto a height of30cms including rounding of junction (the rateincludes for completeitems including labour andmaterials and includingcost of initial treatment ofroof slab as follows. Theinjunction of damp proofor equivalent compoundwith cement solution willbe given as and whenfound necessary for fillinghoney comb cracks etc. inthe R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. |
| 11 | Distempering two or morecoats with oil boundwashable distemper ofapproved brand andmanufacture and ofrequired shade on newwork over and including apriming coat withdistemper primer ofapproved brand andmanufacture to give aneven shade. |
| 12 | Proving and fixing whitevitreous china water closetsquating (European type w.c. pan) with seat and lid C.P. brass hinges and rubberbuffers 10 lts. High level P.V.C.. flushing cistern (ofapproved make ) withfittings rack bolts 32 mmdiameter P.V.C. telescopicflush pipe with fit tingsand clamps 25mm P.V.C..over flow pipe withspecials & mosquito proofcoupling of approvedmunicipal design andnylon. chain and pullcomplete cutting andmaking good the walls adfloors where required.;W.C. pan with white plasticseat and lid. |
| 13 | Providing and fixing brassbib cock (heavy) ofapproved quality :;15 mmnominal bore |
| 14 | Providing and fixing brassstop cock (heavy) ofapproved quality :;15 mmnominal bore |
| 15 | Providing and fixing C.P.brass shower rose with 15or 20 mm. Inlet:;100 mmdiameter. |
| 16 | Providing and fixing HandShower (Health Faucet)with 8mm dia ABS/brassbody with double lock 1.00m long Flexible tube (Brass plated stainles steelflexible hose) and wallhook of approved qualityconfirming to IS standards. |
| 17 | Providing and applyingwhite cement based puttyof average thickness 1.00mm of approved brand andmanufacturer over theplastered wall surface toprepare the surface evenand smooth complete. |
| 18 | Surface dressing of groundincluding removingvegetation in equalities notexceeding 15 cm deep anddisposal of rubbish leadupto 50 m and lift upto 1.5m.;Ordinary soil |
| 19 | Providing and fixing rigidPVC S.W.R. (soil waste &rain water drainage pipesof approved includinglubricant etc. complete(single/double) socketed:;110 mm dia |
| 20 | Providing and fixing rigidPVC S.W.R. (soil waste &rain water drainage pipesof approved includinglubricant etc. complete(single/double) socketed:;75 mm dia |
| 21 | Providing and fixing singleTee of rigid PVC(approved make ) for S.W.R. pipes includinglubricating etc completewith door :;110 mm dia |
| 22 | Providing and fixing singleTee of rigid PVC(approved make ) for S.W.R. pipes includinglubricating etc completewith door :;75 mm dia |
| 23 | Constructing brickmasonry manhole orinspection chamber withsecond class bricks incement mortar 1:5 (1cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4graded stone aggregate20mm nominal sizefoundation concrete 1:2:4mix (1 cement ;2 coarsesand :4 graded stoneagrregate 40mm nominalsize) inside plastering 12mm thick with cementmortar 1:3 (1 cement :3coarse sand) finished witha floating coat of neatcemetn and makingchannels in cementconcrete 1:2:4 mix (1cement :2 coarse sand :4graded stone aggregate 20mm nominal size) neatlyfinished complete as perstandard design.;Insidesize 60 x 60cm and 60cmdeep including C.I. cover with frame (light duty)455x610mm internaldiameter total weight ofcover and frame to be notless than 38 kg. (weight ofcover 23 kg). |
| 24 | Supplying and fixing glasspanes with new woodenfillets including removal ofbroken glass panes and oldwooden fillets wherevernecessary .;Glass panes3mm thick |
| 25 | Providing and fixingColouron Plus galvuliumroofing Sheets of 0.5mmthick double ribbedtrapezoidal profile coated1080mm with cover widthof 1020mm including allthe accessories (JSW orequivalent make) butexcluding the cost ofpurlins rafters trussesflashings etc. complete asper the directions of theEngineer in charge. |
| 26 | Steel work in built uptubular (round square orrectangular hollow tubesetc.) (Square HollowSection (SHS) IS4923/Rectangular HollowSection (RHS) IS4923/ Circular Hollow Section(CHS) IS1161 closedStructural Steel of (SAILTATA. VIZAG JSWAPOLLO Steel Ltd.) make(Min Yeild Stress 310Mpa)) trusses etc.including cutting hoistingfixing in position andapplying a priming coat ofapproved steel primerincluding welding andbolted with special shapedwashers etc. complete. |
| 27 | Identifying of choked inSewerlines between twoconsecutive manholescleaning and removal of allchoked materials withoutexcavating for pipes ofSewer and disposal ofunserviceable rubbishdirtymaterials etc as directedwithin alead of 3kmfromworksite and restoration ofSewers to functioning andflushing theSewersincluding necessarydewateringSewercleaningrodding andscavanging arrangementsall complete within 8 hoursfrom written instruction byEngineer-in-charge. |
| 28 | Flushing and rodding theSewerlines to clear thechokes and removal of gritand silt so accumulated inmanholes due to flushingand rodding outside anddisposal to a distance of 5km includingproviding necessary tools rodsflushing water tankersladderssafety equipment etccomplete. |
| 29 | Providing and fixingASTM UPVC pipeconforming to ASTM 2467with ISO 14001 includingall UPVC plain & brassthreaded fittings includingfixing the pipe with clampsat 1.00 m spacing. Thisincludes jointing of pipes & fittings with one stepUPVC solvent cement andtesting of joints completeas per direction ofEngineer. Internal work -Exposed on wall.;SCH-40(blue)/(white);20mm outer dia. |
| 30 | Providing and fixing 1stquality ceramic glazedwall tiles (JohnsonSomany Kajaria )conforming to IS:15622(thickness to be specifiedby the manufacture ofapproved make in allcolours shades exceptburgundy bottle greenblack of any size asapproved by Engineer-in-charge in skirtingrisers of steps and dadosover 12 mm thick bed ofcement mortar 1:3 (1cement : 3 coarse sand )and jointing with greycement slurry @3.3kg persq.m including pointing inwhite cement mixed withpigment of matching shade complete.;Wall CeramicGlazed Tiles : 200 x 300 |
| 31 | Providing and fixinganodised aluminiumshutters in accordance withthe specification annexedherewith includingtransportation, scaffoldingand handling etc. completeas per direction of theEngineer-in-charge: Adjustablelouvered windows.;Figured glass |
| 32 | Extra for cuttingreinforcement bars in R.C.C. or R.B. Work |
| 33 | Painting two or more coats(excluding priming coat)with superior quality readymixed paint for steel workof approved brand &manufacture in all shadeson new work to give aneven shade. |
| 34 | Transportation andcarriage of material bytipper truck lead beyond5.00km upto 10km.including loading,unloading and stacking. i)Lime, moorum, buildingrubbish Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.