Tender For Day To Day Maintenance Of Internal Electrification In Md Accn Of Age B/R-Ii (Mohan Enclave, Cmp Line, Capt Line) Under Ge (West) Delhi Cantt-10
Tender Value
25 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
15 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Day To Day Maintenance Of Internal Electrification In Md Accn Of Age B/R-Ii (Mohan Enclave, Cmp Line, Capt Line) Under Ge (West) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc.) and making good disturbed surfaces of walls, floor etc. |
| 2 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 1.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with modular metal flush boxes of size 1.6 mm thick including cover plate with frame of white colour of suitable size as required at site, including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed at site for the following: |
| 3 | One light/fan/bell point controlled by one by one way switch. |
| 4 | One socket outlet 6 amps controlled by one switch on independent board. |
| 5 | One socket outlet 6 amps on the same board with other switches. |
| 6 | Ditto- all as per Item No. 2 here-in-before but with cable 2.5 Sqmm size. |
| 7 | M&L for one power point with PVC insulated stranded copper conductor cable 4.00 Sqmm single core 1100 Volts for one 3 pin AC Box outlet, 20 Amps concealed and including provision of 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board. |
| 8 | M&L in repair Modular switch 1 way 6A,1 module, 230V, 50 Hz complete all as specified and directed.(As per sample) |
| 9 | M&L in repair Modular switch 1 way 16A,1 module, 230V, 50 Hz complete all as specified and directed.(As per sample) |
| 10 | S&F in repair Modular socket 6A- 5 pin combined 2 module,230V, 50 Hz complete all as specified and directed.(As per sample) |
| 11 | S&F in repair Modular socket 6A/16A - 2/3 pin combined 2 module, 230V, 50 Hz complete all as specified and directed.(As per sample) |
| 12 | S&F in repair Modular ceiling fan regulator, step type for BLDC ceiling fan 1 or 2 module. (As per sample) |
| 13 | M&L in repair ceiling rose 3 phase PVC polycorbonate,insulated body complete all as specified and directed. |
| 14 | M&L in repair switch modular type single pole Bell push 6 Amp 1 module complete all as specified and directed. (As per sample) |
| 15 | Taking down DBs,VTPN DBs of any make and type from the site and making good to the disturbed surfaces complete all as specified and directed. |
| 16 | M&L in repair MCB distribution board SPN 8 way with 100 Amps rated bus bar metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet complete all as specified and as directed. |
| 17 | S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for 100 Amps, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 including taking down old DBs all as specified.NOTE :-(a) MCBs/MCCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 18 | Supply and fixing in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB with connection testing and commissioning, complete all as specified and directed. |
| 19 | Ditto- all as per Item No.15 here-in-before but 40 amps. |
| 20 | Supply & Fixing in Repair 20A SP mini MCB, suitable for modular AC box, complete all as specified and directed. |
| 21 | Supply and fixing in repair 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 AMP in the MCB DB with connection testing and commissioning, complete all as specified and directed. |
| 22 | Supply and fixing in repair RCBO, 230 Volt, 32 Amp, 30mA, 50 Hz, double pole for ensuring protection from leakage current, short circuit & over load, complete all as specified and directed. |
| 23 | S&F in replacement MCCB 4 pole 125 Amp, Icu = 16 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts, bolts and washers for proper connections all as specified and directed. |
| 24 | S&F in replacement MCCB 4 pole 100 Amp, Icu = 16 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts, bolts and washers for proper connections all as specified and directed. |
| 25 | Supply and fix in repair sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and as directed. |
| 26 | Identifying and rectifying the minor defects pertaining to internal electrification of any type and nature such as taking down defective switch/socket/ceiling rose/holders/fittings / fixtures any type, rectification of faulty electric circuits, tightening of loose connections, replacement of old u/s wiring/conduits/casing capping,connections etc. including consumable items i.e. Screw, wall plug,PVC electrical insulation tape as required on sites complete all as specified and directed. |
| 27 | Identifying and rectifying the minor defects pertaining to internal electrification of any type and nature such as repair in Bldg LT panels ,taking down defective MCBs / MCB DBs/SPN DBs / TPN DBs any type and repairing/replacements, rectification of all type of electrical faults, tightening of loose Panels electric cablels connections, replacement of old U/S MCBs/DBs including consumable items i.e. Screw, wall plug, PVC electrical insulation tape as required on sites complete all as specified and directed. |
| 28 | Supply and fix in repair hylum sheets of the following sizes :- |
| 29 | Sheet as per sample suitable for mounting one piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed. |
| 30 | Sheet as per sample suitable for mounting one piano switch 15Amp and one 15Amp socket dully cut for mounting as above complete all as specified and directed. |
| 31 | Sheet as per sample suitable for mounting five piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed. |
| 32 | Supply and fix in repair metal sunken box of the following sizes :- |
| 33 | Box as per sample suitable for mounting one piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed. |
| 34 | Box as per sample suitable for mounting one piano switch 15Amp and one 15Amp socket dully cut for mounting as above complete all as specified and directed. |
| 35 | Box as per sample suitable for mounting five piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed. |
| 36 | Supply and fix in repair copper wind motor with capacitor, single phase, 240V suitable for PVC fresh air fan of sweep size 200 to 250 mm as per sample given at site complete all as specified and directed. |
| 37 | Supply and fix in repair copper wind motor, single phase, 240V suitable for metallic heavy duty exhaust fan of sweep size 250 to 300 mm as per sample given at site complete all as specified and directed. |
| 38 | S&F in repair exhaust fan body/frame metallic type of any make for size 250/300 mm sweep with mounting legs, nut, bolts, fastners complete for mounting as per requirement at site, all as specified and directed. |
| 39 | S&F in repair pvc fresh air fan body/frame 200 to 250 mm, complete for mounting as per requirement at site, all as specified and directed. |
| 40 | S&F in repair exhaust fan blade of any make for size 225 mm to 300 mm sweep as per requirement at site complete all as specified and directed. |
| 41 | Supply only pvc fresh air fan blade for size 200 to 250 mm, as per sample complete all as specified and dircted. |
| 42 | Supply & Fixing in repair T-cover with brass screws, as per site requirement including all connected items complete all as specified and directed. |
| 43 | Supply and fix in repairs LED bulb of 9 watt (B-22), including duly connecting, fixing with all accessories complete all as specified and directed by Engr-in-Charge. |
| 44 | Supply and fix in repair 9/10W LED bulkhead luminaires with color temperature 3000K-6500K, including connecting up with necessary PVC sheathed 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed. |
| 45 | Supply and fix in repair LED batten luminaire surface mounted system wattage of 10 watts and system efficacy =>100 lm/watt, color temperature 3000K- 6500 K, IP- 20 protected, voltage range 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including all connection upto ceiling rose complete all as specified and directed. |
| 46 | Supply and fix in repair LED batten luminaire surface mounted system wattage of 20 watts and system efficacy =>100 lm/watt, color temperature 3000K- 6500 K, IP- 20 protected, voltage range 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including all connection upto ceiling rose complete all as specified and directed. |
| 47 | Supply and fix in repair new generation LED post-top-lantearn 40 Watts,IP 65 energy saving, environmental friendly long life aesthetically designed with symmetrical light distrubution, complete all as specified and directed. |
| 48 | S&F of 35 watts 230 V AC outdoor type with High efficient LED Building security light fitting with high pressure die cast Aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP: 65/66 protected complete with bracket made out of 32 mm GI pipe light grade 1.2 mtr long bend to shape with clamps and fixing bolts all as specified and directed. |
| 49 | Supply & Fixing in repair ultra bright compact LED downlighter 12/15 Watts (round or square shape) with high efficiency LEDs ideally suited for low ceiling areas to give glare free light, complete all as specified and directed. |
| 50 | Supply and fix in repairs decorative wall light fittings suitable for LED bulb of 9/12 watt (B-22), including connection with all necessary fixing accessories complete all as specified and directed by Engr-in-Charge. |
| 51 | Identifying and rectifying the defects pertains to ceiling fans/exhaust fans/Air ventilation Fan and connects electric circuit, tightening of loose wiring/conduits/fan capacitors and connection carrying out minor repairs incl blade alignments, screwing/ tightening the nuts/bolts/washers etc incl taking down & refixing properly in the same position after repairs, complete all as specified and directed. |
| 52 | Dismantling of complete defective Ceiling fan of 1200 mm sweep i.e. down rod with its Canopies, Shackle, Blade, Condenser housing with its rubber bushes, split pins, unscrewing the body parts of Ceiling fan, taking out starter, rotor winding,ball bearing, gun metal bush etc. complete to carry out the following repairs :- |
| 53 | Notes :- (a) Removing of burnt out fan winding and rewinding of starter winding with suitable size of Copper enamelled wire, ( weight of copper coil shall be same as per dismantled Fan) varnishing heating and testing as per manufactures designed & specifications and as directed by Enge-in-charge. |
| 54 | (b) Re-assembling complete Ceiling fan by fixing only serviceable of old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, blades, ball bearing, twin twisted Copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling, cleaning outer body & surfaces etc all as directed. |
| 55 | Ditto- all as per Item No. 43 here-in-before but Air ventilation PVC body/ metal body exhaust fan of size 200 mm to 300 mm sweep. |
| 56 | Ditto- all as per Item No. 43 & 46 here-in-before but only overhauling of celing/exhaust fan by greasing and oiling, replacement of unserviceable/defective components, except rewinding complete all as directed. |
| 57 | Note Sl.No. 43 & 46 : (a) Spare parts found unserviceable/defective will be measured and paid separately under relevant item as Supply and fix in repair . |
| 58 | Supply in repairs/replacements of following spare of ceiling fan 1200mm/1400mm sweep of any make :- |
| 59 | Fan capacitor of capacity 2.5/3.5 mfd, 220 Volts, AC 50 Hz, plastic-casing, two terminal-copper wire, complete all as specified and directed. |
| 60 | S&F in repair MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed. |
| 61 | Ball bearing of size 6201/6202 as per sample complete all as specified and directed. |
| 62 | PCB card for BLDC ceiling fan size 1200 mm sweep with nominal voltage 230V AC, power consumption 28 to 32 watt, suitable for existing fan. |
| 63 | Gun metal bush as per sample. |
| 64 | MS down rod 300 mm for fixing of ceiling fan all as specified and directed |
| 65 | Fan canopy pvc body, white in colour, suitable for existing fan, as per sample and directed. |
| 66 | S&F of stainless steel louver shutter of exhaust fans suitable for 300 mm size at the height from 3 mtr to 14 mtr making good surface of disturbed area including taking down old louver shutters complete all as specified & directed. |
| 67 | Supply and fix in repair plug top 20 Amps 3 pin 230- volts complete all as specified and directed. |
| 68 | Supply and fix in repair Socket 20 Amps 3 pin 230- volts complete all as specified and directed. |
| 69 | Taking down carefully sub main wiring three single run 6 Sqmm of any make and type complete all as directed. |
| 70 | Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits/existing conduits including cutting of chases for laying conduit (if required) making good the disturbed surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated sheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete all as specified and directed. Note :- Two runs of IC x 6.00 sqmm (Phase wire and neutral ) and one run of IC x 6.00 sqmm (as earth wire) will be measured as one unit length. |
| 71 | S & F in repair PVC insulated flexible cable three core copper conductor of size 1.5 Sqmm, ISI marked, covered with white colour round insulation complete all as specified and directed. |
| 72 | Supply and fix in repair single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 73 | Supply and fix in repair single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 74 | Supply and fix in repair single core PVC insulated cable 4.0 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 75 | Supply and fix in repair single core PVC insulated cable 6 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-charge. |
| 76 | Supply and fix in repair switch piano flush type 6 Amp SP one way complete all as specified and directed. |
| 77 | Supply and fix in repair switch piano flush type 6 Amp SP two way complete all as specified and directed. |
| 78 | Supply and fix in repair switch piano flush type 16 Amp SP one way complete all as specified and directed. |
| 79 | Supply and fix in repair socket outlet 6 Amp flush type complete all as specified and directed. |
| 80 | Supply and fix in repair socket outlet 16 Amps complete all as specified and directed. |
| 81 | Supply and fix in repair switch type normal electronic fan regulator 5 step complete all as specified and directed. |
| 82 | Supply and fix in repair bell push switch, flush type, 5 amp complete all as specified and directed. |
| 83 | Supply and fix in repair bell ding dong AC, 230 volts, single pole complete all as specified and directed. |
| 84 | Supply & fixing in repair of SS combined 6/16 amp without box complete all as specified and directed by Engr-in-charge. |
| 85 | M & L for Overhauling/Dismantling of defective/rusted Geyser of 25 Ltr capacity, removing inlet/outlet connections, taking out U/S parts by unscrewing bolts and nuts etc, checking defects and re-assembling the Geyser after refixing serviceable/new parts & cleaning, descaling and refixing only serviceable items and re-installing the Geyser in suitable place/position and connecting inlet-outlet connections & testing complete, all as specified and directed by Engr-in-charge.Note:(a) Items required for replacement of U/S parts will be measured and paid separately under relevant item of sch \\"A\\" ). |
| 86 | Supply in Repairs/Replacements of following spare parts of geyser storage type of different make for capacity 25 ltrs. (Make of spare parts shall be of existing make or as per samples as required) |
| 87 | Apparatus assembly duly prewired without heating element and thermostat/thermal cutout. |
| 88 | Indication lamp (Green/Red) as per sample. |
| 89 | Thermostat as per sample as per sample. |
| 90 | Heating element 2.0 KW, circular/square/rectangular cross section of required size as per site requirement, complete all as specified and directed. |
| 91 | Cover outer for geysers suitable for any make/capacity/type of geysers installed at site duly painted complete all as specified and directed. |
| 92 | Stainless Steel inner tank of 25 Ltrs capacity complete all as specified and directed. |
| 93 | SS braided pipe of 12 mm dia suitable for hot/cold water, 450 mm long with brass nuts and rubber washers complete all as specified and directed. |
| 94 | S&F in repair Fresh Air Fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200/250 mm sweep, single phase,including cutting of holes in wall/windows for fixing the fresh air fan complete all as specified and directed. |
| 95 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.×6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to earthing test point including testing on completion all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender