Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56223993

Tender For Repair/Maintenance For Air Flow Duct , Internal Electrification Etc At 6 Afh, Pocket C And Echs At Afac Under Age(I) Af Coimbatore

Issued by Statutory Bodies & Commissions/Committees · Coimbatore, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Jul 2026
10 days left
EMD
18000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance For Air Flow Duct , Internal Electrification Etc At 6 Afh, Pocket C And Echs At Afac Under Age(I) Af Coimbatore

BOQ

Name of Work:- REPAIR/MAINTENANCE FOR AIR FLOW DUCT , INTERNAL ELECTRIFICATION ETC AT 6 AFH, POCKET C AND ECHS AT AFAC UNDER AGE(I) AF COIMBATORE
Sl. No. Item Description
1Receiving/recording complaints lodged by the occupants of all Md/OTM Accn of AFAC, Coimbatore area under AGE (I) (AF) Coimbatore of internal electrification nature, rectification of the fault / complaints as per the complaint lodged by the user or as given by MES from DB's box / Electric Meter having switch, fuses, MCB distribution board in sheet metal enclosure, point wiring, fixture for light/ Fan/bell/light or power sockets complete replace with new one or repairs to the extent by removing connections from the system, removing faults in wires, batten, conduit, sunk boxes, junction boxes, main switches, MCBs/DBs utility light fittings, FTL light fitting any wattage lamp, holders, ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as insulation wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws, nuts as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engineer-in-Charge/users. Note (i) All the complaint(s) received will be lodged & rectified by the contractor rep and will have to maintain a proper record as directed in complain register and in complaint slip (ii) Complaint slip and complaint register will be provided by the contractor without any extra charge. (iii) Complaint regiter will be produced on daily basis to JE and Engr-in-charge (iv) Contractor shall employee having minimum four year experiance electrical work in the said field. (vi) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’. (vii) Contacrtor failing to atttend the complient with in 24 Hrs time impose necessary penalty of Rs 1000 per complient per day till the time of rectification. (viii) Contrator deploy the electrician with helper daily excluding sunday and holidays without fail and necessary attendence register produced to Engr -in Charge whenever demanded all as directed
2Taking down old unserviceable point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
3Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces all as directed.
4Disconnecting electric connection and taking down main switch/SPN DB/TPN DB of any size and keep in safe custody for taking credit complete and good/levelling the disturbed surfaces of wall to match with existing surface.
5M&L for Point wiring one light/bell point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls/surface and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases and making good in wall / floor will be Measured and paid seperately.
6All as per item No 5 herein before but one ceiling/exhaust fan point controlled by one, one way switch.
7All as per item No 5 herein before but one light point controlled by two 2 way swithch.
8All as per item No 5 herein before but one 05 Amps socket outlet point on same board.
9All as per item No 5 herein before but one switch socket outlet point 5 Amps on independent board.
10All as per item No. 5 here-in-before but with copper conductor cable FRLS, 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board.
11All as per item no 5 above but copper conductor FRLS 4 Sq mm
12All as per item No 5 above one light/fan/bell point in PVC casing caping suitable size including terminal box for housing switches sockets regulaters with hylum sheet top cover all as directed (minimum 20 MM)
13All as per item No 5 above one 5 amps socket point on same board in PVC casing caping suitable size including terminal box for housing switches sockets regulaters with hylum sheet top cover all as directed (minimum 20 MM)
14All as per item No 5 above one 5 amps socket point on independent board in PVC casing caping suitable size including terminal box for housing switches sockets regulaters with hylum sheet top cover all as directed (minimum 20 MM)
15All as per item No 5 above one 15 amps socket point on independent board with 2.5 sq mm FRLS copper conductor in PVC conduit suitable dia including terminal box for housing switches sockets regulaters with hylum sheet top cover all as directed (minimum 20 MM)
16S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed.
17S&F Switch Modular 6A single pole, two way, 1 module complete all as specified and as directed.
18S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed.
19S&F Modular Modular Bell Push 6A 1 Module complete all as specified and as directed.
20S&F Socket, modular 6A - 2/3 pin combined 2 module complete all as specified and as directed.
21S&F socket Modular 6/16A 2/3 pin combined 2 module complete all as specified and as directed.
22S&F Modular fan regulator step type 120 W, 2 module complete all as specified and as directed.
23Supply and fix T8 20 watts retrofit LED tube PC cool day light 240 volts high efficiency approx 110 luman per watt, power supply in single side connection 2 pin terminals including taking down unserviceable lights all as directerd Cat No LTP820N of luker or equivalaent Make - Bajaj, Philips, Wipro, Crompton, Halonix, Luker
24Supply and fixing LED battern fitting 1 x 18/ 20W, powder coated white finish 220V,AC box type with driver, holder including LED lamp connecting up with three core white flexible copper conductor cable of suitable size from ceiling rose including taking down unserviceable lights all as directerd complete . Model T5 LT 20 Make - Bajaj, Philips, Wipro, Crompton, Halonix, Luker
25Supply and fixing LED battern light fitting with high out put diffuser 5 watts 220 V AC with driver holder and LED lamp including connecting up with white three core flexiblecopper conductor cable of suitable size including taking down unserviceable lights all as directerd complete model T5 LT505P. Make - Bajaj, Philips, Wipro, Crompton, Halonix, Luker
26Supply and fixing round / squre shape 9/12 watt 220 Volt AC recessed type with hight efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
27Supply and fixing round / squre shape 15/20/24 watt 220 Volt AC recessed/surface type with hight efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with three core white flexible copper conductor cable of suitable size complete. (Note : All recess mounted lights celing cutout size as per existing size at site)
28Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 Watt, 220 V AC recessed/surface type with hight efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core white flexible copper conductor of suitable size complete.
29Supply and fixing LED high bay luminaire 100 watts with mounting eye hole with hook 220 V AC surface mounted type with hight efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof including connecting up with driver three core white flexible copper conductor of suitable size and taking down unserviceable light all as directed complete.
30S & F Call Bell Ding Dong AC 230 V single pole complete connecting up with flexible copperconductor cable of suitable size.
31Supply and fix MCB DB, SPN, 8 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete. Make: L&T/Legrand/ Havells
32All as per item No. 31 above but DB SPN 12 ways (Note The existing serviceable MCB's refixing as per existing circuit/position all as directed)
33All as per item No. 31 above but DB TPN 4 ways (Note The existing serviceable MCB's refixing as per existing circuit/position all as directed)
34All as per item No. 31 above but DB TPN 8 ways (Note The existing serviceable MCB's refixing as per existing circuit/position all as directed)
35Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, \\"B\\" Curve complete. Make: L&T/Legrand/ Havells
36Supply and fixing SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete. Make: L&T/Legrand/ Havells
37Supply and fixing TP 25 to 63 Amp rating 440 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete. Make: L&T/Legrand/ Havells
38Supply and fixing TPN/FP 16 to 32 Amp rating 440 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete. Make: L&T/Legrand/ Havells
39Supply and fixing TPN/FP 40 to 63 Amp rating 440 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete. Make: L&T/Legrand/ Havells
40Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals.
41Material and labour for duct insulation with resin bondded fibre glass wool roll of density 24 Kg/Cum with factory laminated aluminium vapour barrier, thickness of the insulation is 50 mm and including the following (a) M&L for cleaning of the duct surface by scrapping carefully with wire brush etc to make the surface completely free from dirt,dust,grease and other foreign materials, seal the duct joints against leakage (b) M&L for applying the rubber based adhesive CPRX compound (c) M&L for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide to make the insulation leak proof (d) M&L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12 mm/50 mm at maximum intervells of 1.2 Mtr including damage insulation any type in any position all as directed
42Supply and fix Presure gauge 8\\" dial 0-14 Kgs rating including taking down old gauges all as directed
43Supply and fix liquid/gas filled temparature gauge 0 to 100 degre range of scale celcius and faharanheit stem type dial (150 mm)/squre type class 1 accuracy suitable to fit in eixisting air ducts/flow pipes etc with necessary fixing arrangement required at site including taking down unserviceable one any type all as directed Make H guru, Japsin, PI control, Danfoss
44Supply and fix liquid/gas filled room hygrometer celcius/faharenheit scale and humidity temparature gauge 0 to 100 degre range of scale wall mounted type analog display class 1 accuracy suitable to fit in eixisting locations with necessary fixing arrangement required at site including taking down unserviceable one any type all as directed Make H guru, Japsin, PI control, Danfoss, DWEPTU
45Supply and fixing tack light rotation type 18 watts LED 220 V AC track mounted type with hight efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for existing track and taking down unserviceable light all as directed complete.
46Materail and labour for PUF insulations for MS pipe with PUF slab 40 mm thick with and including applying bituminuoues compound and GI cladding with 26 gauge GI sheet complete or ready fix puf insulation semi circle slab suitable for 100 mm dia MS pipe including taking down unserviceable PUF insulation all as directed
47M&L for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
48All as per Item No 47 above but 4.0 sq mm.
49All as per Item No 47 above but 4 runs of 6 sq mm
50Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; andcutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56223993
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 14-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance For Air Flow Duct , Internal Electrification Etc At 6 Afh, Pocket C And Echs At Afac Under Age(I) Af Coimbatore
Basic Detail
Tender No 8181_E8
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 30 Jun 2026
Submission Date 14 Jul 2026
Open Date 16 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 18000
Exemption Available
Document List
8cc6e733-df57-434e-9a36-15c75c187188.html
BOQ_868329.xls
credit_exc.pdf
General_pages_.pdf
Particular_Specifications.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

8cc6e733-df57-434e-9a36-15c75c187188.html

xls

BOQ_868329.xls

pdf

credit_exc.pdf

pdf

General_pages_.pdf

pdf

Particular_Specifications.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders