Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #56223825

Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Works To Be Executed At Water Supply Facilities Of Hirpora Banimulla For Source Sustainability Under Ut Capex.

Issued by Government Departments · Pulwama, Jammu and Kashmir
Tender Value
50.35 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing And Commissioning Of Electro-Mechanical Works To Be Executed At Water Supply Facilities Of Hirpora Banimulla For Source Sustainability Under Ut Capex.

BOQ

Name of Work:- Supply, Installation, Testing and Commissioning of Electro-Mechanical works to be executed at water supply facilities of Hirpora Banimulla for source sustainability under UT Capex.
Sl. No. Item Description
1Supply, Installation, Testing & Commissioning of Submersible Pumping Unit as per IS 8034 with latest amendments having the specification as under:- PUMP: Discharge = 4000 GPH Head = 194 m Efficiency = Not less than 50% Speed = 2900 RpmType of pump : Mixed flow. Type of fluid to be handled: MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel / chrome steelPump Shaft = Stainless Steel SS 410. Pump Casing = Cast IronIMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set.Non Return Valve: Non Return Valve of the suitable size provided above the pump discharge case.MOTOR:- Method of starting = Star – Delta Speed = 2900 (Sync).Frequency = 50 ± 3 % Hz Working Voltage = 380 -415 ± 15% V, 03 phaseEfficiency =As per IS 9283 (2013) with latest amendments. Rating = Not less than 25 HPClass of insulation = F/ BSubmersible motor should be water filled, water lubricated squirrel cage type ,working on 3 phase; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length.b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of thickness (as per Table-17) at other end for 65 mm diameter column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing.The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site.Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory.
2Supply, Installation, Testing & Commissioning of Submersible Pumping Unit as per IS 8034 with latest amendments having the specification as under:- PUMP: Discharge = 4000 GPH Head = 250 m Efficiency = Not less than 50% Speed = 2900 RpmType of pump : Mixed flow. Type of fluid to be handled: MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel / chrome steelPump Shaft = Stainless Steel SS 410. Pump Casing = Cast IronIMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set.Non Return Valve: Non Return Valve of the suitable size provided above the pump discharge case.MOTOR:- Method of starting = Star – Delta Speed = 2900 (Sync).Frequency = 50 ± 3 % Hz Working Voltage = 380 -415 ± 15% V, 03 phaseEfficiency =As per IS 9283 (2013) with latest amendments. Rating = Not less than 30 HPClass of insulation = F/ BSubmersible motor should be water filled, water lubricated squirrel cage type, working on 3 phase; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length.b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of thickness (as per Table-17) at other end for 65 mm diameter column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing.The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site.Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory.
3Fabrication, providing, fitting and lowering of C class column pipe conforming to IS: 1239 of length 10 Rft into the sump; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labors, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 No. rectangular cable slots in each flange. Any modification to the column pipes /flanges required during lowering is included in the job.Size : DN 65 Class: C (Heavy)
4Providing/supplying and fitting of G.I flanged Rising Main–The Pipe shall be hot dip Galvanized, class C class Heavy pipe confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make.Flanges (as per IS 6392/1997 Table:17)Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint.Welding ElectrodeDC Arc Welding using welding electrode having diameter not less than 4mm.Nuts and BoltsNuts and Bolts (conforming to IS:1363 Part 1st)Rubber Insertion GasketsRubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The main technical specifications of the pipe are given here under:Size: DN 65mm Class \\"C\\" Heavy
5Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: - i. Valve type - single chamber, single/double orifice. ii. End connection - flanged ends to IS 1538 iii.Working temperature - 45oc to -150 c iv. Test pressure - body / seat 2.5 x PN v. Sealing ring - EPDM vi. Construction - ductile iron with stainless steel floats vii. Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, GI Pipe, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site.The Test Certificates of Air Release Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material.Size : DN 50mm Rating: PN16
6Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil- 1m from cutting edge.
7Filling available excavated earth in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift upto 1.5m.
8Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size). The job also includes all the necessary head load
9Fabrication, providing and fitting of split type MS clamps 10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. (Pair)Size : 65 mm
10Fabrication, Providing and fitting of 90-120 degree bend/elbow to be fabricated out of Class C GI pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with welded jointson three ends. The job includes nuts, bolts, gaskets etc complete.Size : DN 65, Class C
11Fabrication, providing and fitting of washout Tee with arm length 1 feet each (Approx). The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. The size of the Tee is given Below:Size: DN 65 MM
12Supply, Installation, Testing and Commissioning of Ductile Iron double flanged, non-rising spindle Resilient seated gate/ sluice valves as per IS 14846 (PN16) in accordance with BS 5163 part 1 and part 2 / EN 1074 Part 1 & 2 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work.The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. The Test Certificates of Sluice/Gate Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material.Size: DN 65 mm Rating: PN 16
13Supply, Installation, Testing and Commissioning of Ductile Iron double flanged, Slanted seat swing check valve (NRV) (PN16) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions.It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve.Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work.The job includes providing and fitting of 02 Nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. The Test Certificates of Check Valves (NRVs) mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of materialSize: DN 65 mm Rating: PN 16
14Providing, Fabrication and fitting of Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position. The Structural steel is to be utilized for fabrication of gantry. The Steel may include ISMB, ISMC, ISA (Angle Iron), MS plates etc as per the site requirement. The drawings and dimensions will be provided by Site In Charge at the time of execution of job.Rough estimation for fabrication of gantry. MS Sheet 475x304x12mmx4 No.=53kgMS Sheet609x609x12mmx2No.=70 kgISMC150x4876mmx4 No.=320 kgISMC100x254x36No.=85 kgISMB 200x3657mm.=93 kgBolt 25x609x8No.=19 kgTotal=53+70+320+85+93+19=640 kg
15Providing, installation and testing of manual type triple spur gear chain pulley blockLoad Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported and Specially designed, perfectly machined wheel providing correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Capacity = 2 ton No. of chain falls = 2 or above Min. Height of lift = 6 M
16Earth work in excavation required for installation of gantry by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil- 1m from cutting edge.
17Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns.
18Providing and laying of stone soling including manual compaction.
19Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size).
20Painting of the gantry and plate form of well using one coat of red oxide metal primer and two coats of enamel paint of different shades.
21Supply, Installation, Testing and Commissioning of outdoor type Electric Sub Station as per the technical specifications given here under -Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments.Type: HT/LT Transformer (Level-2)Capacity:- 100 KVAType of cooling: ONAN.Operating conditions:Input =11000 voltsOutput = 433 volts AC supply in 3- phase.Terminals:Input = 3 No. HT Brass bush rods with insulators, washer, nuts etc.Output = 4 No. LT Brass bush rods switch insulators, washers, nuts etc.Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved.The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vent and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment.
22Providing and fitting G.I Channel /Angle/ Flat/ V crosses/ F- tops of sizes including clamps. The job includes fitting of Channels on two poles for the installation of insulators and safety devices, GO Set, Lighting Arrestor etc. It also includes the channels for fitting of LT Meter and LT Distribution Box. The job includes P/F of GI channels at Tapping point for installation of GO Link Set, Pin Insulators Etc as per site requirement.Size of Channel= ISMC 75X40MM & ISMC 100x50mm
23Supply, Installation, Testing and commissioning of 01 No. Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT pole double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings, operating handle and 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. The 11 KV AB switches shall conform to IS: 9920 (Part-I to IV).01 No. GO Set is to be fitted at tapping point and 01 No at HT Transformer (Substation).
24Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.
25Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type.
26Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creepage distance 320 mm.
27Supply, installation, erection of 9 mtrs long H.T pole of specifications ST- 410 (sp-33). The job further includes drilling of holes for installation of various accessories, wherever required the job further includes G.I wire earthing of pole as per IEC standard.
28Supply, installation, erection of 11 mtrs long H.T pole of specifications ST- 410 (sp-54). The job further includes drilling of holes for installation of various accessories, wherever required the job further includes G.I wire earthing of pole as per IEC standard.
29P/F of Galvanized nuts bolts of various sizes as per site requirement.
30Earth work in excavation required for installation of HT poles by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil- 1m from cutting edge.
31Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns.
32Providing and laying of stone soling including manual compaction.
33Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size).
34Providing and fitting of PG clamps
35Painting of poles with red oxide.
36Painting of poles with Aluminum Paint.
37P/F Danger Plate with clamps on every HT pole.
38Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices. The barbed wire shall be tightly close wrapped around the pole for 10-12 turns, commencing at 2.50m above the datum line.
39Supply, Installation, Testing and Commissioning of Galvanized stay set with 50 X 8 mm Stay Clamp, Guy insulator (2 No.), Anchor plate (200X200X6mm), nuts and bolts, 2 No.- turn buckle, 1.8 m long, 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.
40Supply, installation,testing and commissioning of 11 KVA Disc insulator set 45 KN
41Supply, installation, testing of 50 sq mm XLPE HT cable (ABC type) of 11 KV Grade with following specifications size cross sectional area in sq mm) =3x35 phases Red, Yellow, Blue
42Providing and fitting of anchoring clamps comprising clamp body, plastic wedge, steel bill bracket, straps and buckles or nuts and bolts required for holding three core, 50 sq mm HT AB cable.
43Supply, Installation, Testing and Commissioning 11 KV cable termination kit for connecting 50 Sq mm ABC cable (ABC type) with the existing HT line near tapping point and HT transformer.
44Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mm ACSR (Galvanized steel reinforced) for fitment of various accessories.
45Supply, Installation, Testing and Commissioning of LT Distribution box for H.T transformer to be fitted on GI Channels. MCCB rating: 200A, SFU rating: 100A. Capacity of transformer: 100 kVA
46Supply, Installation, Testing and Commissioning of PRODIGY LT Meter of following specification complete with all fixtures required for fitment at site Type: 3 Phase, 4 wire Measurements offered: KWh, KVARh, KVAh, KVAVoltage : 3x240V (415v), 50HZIb : 40A Imax: 200A Battery: LithiumThe Prodigy Meter must be fitted inside the Box, that is to be fitted on GI Channels near LT Distribution Box. Both the enclosures must be symmetrical Sealing /Inspection report of Prodigy meter from JKPDCL (Concerned) is to be submitted by the firm at the time of charging of SUBSTATION.
47Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection (For Well)Class : IP-55 & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER with current density of suitable rating. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards b) Main Circuit Breaker (Incomer MCCB): Qty. = 02 No.No. of poles = 4 Pole Current Rating = 160 Amp. Rated operational voltage = 415 V + 15 % Rated frequency = 50+/-3%Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) =50 KA,Type of release = Thermal-Magnetic Thermal Release Range = 125-160 AOverload protection = 0.8 – 1×ln adjustable Short-circuit protection = 6-10×ln adjustable.c) Change over Switch: Qty. = 01 No. Rating = 160 Ampere Type = Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hzd) Motor Back-up Protection MCCB: Qnty = 2 No. No.of poles = 4Pole, Current Rating = 125 A Rated operational voltage = 415 V +15 % Rated frequency = 50 + 3% Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36KA. e) Submersible starters = Fully automatic submersible motor starters. Capacity = 25 HP Power Specs = 3 Ф, 415 + 15% V, 50 + 3 % Hz. Relay range = 45-75 A,Coil Voltage = 380 v Protection = Under voltage/Over voltage relays (01 No. for each starter) Rated insulation voltage = 690V Terminal capacity = 120 Sq. mm with lug Or above Conformity to standard = IS/IES 60947-4-1 Qty. = 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty. = 1 No. No. of poles = 4P, Current Rating = 63 Amp. Rated operational voltage = 415 V + 15 % Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 25 KA g) Motor Protection Relay: Digital Motor Protection Relay with LCD Display (MM10) for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, over current, Prolong starting, Locked Rotor & Earth fault. Qty = 02 No,s (01 for each starters) h. M-power module for mobile starter for submersible motor 1P/3P 3 wire IVRS Languages – English, Hindi, Suitable Region- North India.The panel shall be provided with phase indicators (03 No,s) and digital ammeter of range 0-60 A, digital voltmeter of range 0-500 V, and digital frequency meter 01 No for each starter(Single Function Type). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and powder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements.Preferably make of constituent parts: ABB/Schinider/L&K/C&S
48Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection (For Well)Class : IP-55 & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER with current density of suitable rating. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards b) Main Circuit Breaker (Incomer MCCB): Qty. = 02 No.No. of poles = 4 Pole Current Rating = 200 Amp. Rated operational voltage = 415 V + 15 % Rated frequency = 50+/-3%Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) =50 KA,Type of release = Thermal-Magnetic Thermal Release Range = 125-160 AOverload protection = 0.8 – 1×ln adjustable Short-circuit protection = 6-10×ln adjustable.c) Change over Switch: Qty. = 01 No. Rating = 160 Ampere Type = Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hzd) Motor Back-up Protection MCCB: Qnty = 2 No. No.of poles = 4Pole, Current Rating = 125 A Rated operational voltage = 415 V +15 % Rated frequency = 50 + 3% Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36KA. e) Submersible starters = Fully automatic submersible motor starters. Capacity = 30 HP Power Specs = 3 Ф, 415 + 15% V, 50 + 3 % Hz. Relay range = 45-75 A,Coil Voltage = 380 v Protection = Under voltage/Over voltage relays (01 No. for each starter) Rated insulation voltage = 690V Terminal capacity = 120 Sq. mm with lug Or above Conformity to standard = IS/IES 60947-4-1 Qty. = 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty. = 1 No. No. of poles = 4P, Current Rating = 63 Amp. Rated operational voltage = 415 V + 15 % Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 25 KA g) Motor Protection Relay: Digital Motor Protection Relay with LCD Display (MM10) for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, over current, Prolong starting, Locked Rotor & Earth fault. Qty = 02 No,s (01 for each starters) h. M-power module for mobile starter for submersible motor 1P/3P 3 wire IVRS Languages – English, Hindi, Suitable Region- North India.The panel shall be provided with phase indicators (03 No,s) and digital ammeter of range 0-60 A, digital voltmeter of range 0-500 V, and digital frequency meter 01 No for each starter(Single Function Type). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and powder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements.Preferably make of constituent parts: ABB/Schinider/L&K/C&S
49Supply, Installation, Testing and Commissioning of 50 KVA voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step.Type of Regulator : Double plate type with electrolytic copper contacts.Input voltage :190-400 volts.(3 phase)Output voltage : 415 ± 10% volts.Frequency : 50 ±3 C/S.Windings : Electrolytic grade copper of adequate section, vacuum impregnated and Oven-dried.Insulation : Fiber glass insulations to tested parameters.Cooling : Naturally, Oil cooled (ONAN)Temp. Rise (Max) : 30°C above ambientMounting : On Uni-directional wheels.Correction rate : 40 volts per stepWave form distortion : virtually nilDuty cycle : 100% continuous.Enclosure : MS sheet enclosure in pressed CGR Sheet powder coated with radiators.Core laminates : High grade, low eddy loss, grain oriented silicon steel laminations.Load : Three phase induction motor load.Load Amperes (continuous)Overload in 24-hours operation: 10% above continuous Ampere rating.The voltage stabilizer shall have T-oil level indicator gauge preferably glass type tube or otherwise visible to naked eye. The top of the container to have a display panel for housing 02 numbers Digital voltmeters (0-500V) along with 4-way selector switch and set of neon indicators for incoming and outgoing phases (06 No’s).Insulating media (T. Oil) of 11 KVA grade to be provided and filled up to top level, with dielectric strength of 5 KV at 4m air gap. The T-Oil of specific grade should be provided in separate barrels and filled at site up to top level.The voltage Stabilizer shall be accepted with manufacturers dully stamped test certificate and shall have name plate with specifications.
50Supply, Installation, Testing and Commissioning of 3.5-Core, XLPE, 1.1KV and 11KV grade Armoured Aluminium Cable conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. (Service line from HT Transformer and D.G Set).i) 70 sqmm, 3.5 core, LT cable
51Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below:Size :- 16 sqmm
52Supply, Installation, Testing and Commissioning of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated GI earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip (25x3mm) as per relevant standards.Safe earthing electrode size : 80 mm dia,Length : 2000 mmBack fill compound : 30 kg
53Illumination of Premises:Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items.1) 3 Way Terminal Connector 20 Amp.2) 3 No MCB 8 Amp.The job includes fabrication, providing and fitting of three arm GI structures at the top having 120˚ angle between arms and each arm having 15˚ inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary.The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm.The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code.
54Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole. Having following specs:Input: 90-240 V 50 HzPower Factor: >0.9Colour Temperature: 4K - 6.5KBeam Angle: 120˚ - 170˚Lumens: >12000Operating Temperature: -20˚C to 60˚CThe LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68.The LED is properly fitted on the arm of the pole and connected to the copper wire as provided in the high mast pole.
55Supply, Installation, Testing and Commissioning of L.T, 1 core, capable to work up to 1.1 KV, to be fitted from modular control panel to stabilizer etc. (interconnecting cable). The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation wherever required for laying of cable underground. Size: 25 sq mm
56Providing and fitting of 02 core, XLPE, 1.1 KV and 11 KV grade Armoured Aluminum Cable of Various sizes confirming to IS:7089 part 1st as service line from HT transformer to Control panel including necessary thimbles, crimping, taping etc.Size: 10 sq mm
57Supply, installation testing and commissioning of perforated cable tryes including horizotnal and vertical bends, tees , cross members and other accessorei as required and duly bolted to walls of building wih geaser bolts including nuts and bolts 150x50x1.6 mm
58Supply, installation, Testing & commissioning of 1050VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover, with 2-core 4 mm2 Cu (25 m) wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.
59Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: -Composition: Rubber (synthetic mats for electrical purpose)Thickness: - 2.5mm Size: - 1M wide.
60Supply, installation, testing and commissioning of 58.5 kVA, 3 Phase, 415V AC, Silent DG Set confirming to CPCB IV + comprising of Engine, with minimum 74.4 BHP, at 1500 RPM, coupled with alternator and mounted on a common base frame complete with • Fuel tank • Battery & leads • Silencer – Residential • AVM(Anti-Vibration Mounting) pads• Standard control panel• First Fill of lube oil • Acoustic enclosure • Aluminium Power cable ( upto 60 mtr) •Transportation upto Site•CommissioningThe DG set shall be able to operate at 1850m AMSLTECHNICAL REQUIREMENT DIESEL ENGINE Type : The Diesel Engine shall be suitable for generating set application• Developing specified BHP at 1500 RPM under NTP conditions of BS: 5514 or equivalent in IS, Liquid cooled, Turbocharged Inter-cooled, powered by four (4) strokes, multi cylinder with engine performance requirement as specified below. Diesel engines shall be as per MOEF (MINISTRY OF ENVIRONMENT, FOREST AND CLIMATE CHANGE) notification dtd. 3rd November 2022. Only Indian origin Engine is acceptable as per PPP (Public Procurements P-45021/2/2017-PP(BEII)) policy Nominal Output : To match with, alternator 58.5 kVA at 0.8 pf (lagging) i.e., 46.8 kW.• Revolution : 1500 rpm• Starting System: 12 V battery operated electric motor starting.• Fuel : High speed diesel oil• Governing Class: G3• Aspiration System : Turbocharged Inter-cooled• Cooling System : Liquid cooled • Lubrication System: As per engine OEM StandardEngine shall meet the following parameters: - The Engine shall be enclosed in an enclosure to make it work silently (as per CPCB IV norms) without any degradation in its performance. - The fuel shall be used: High Speed Diesel (HSD) as per IS: 1460. - Filter shall be dry type air filter with replaceable elements. - The Engine shall have closed loop lubricating system. No moving parts shall require lubrication by hand prior to the start of engine or while it is in operation. - The Engine shall be electric starting (by 12 V DC starter motor system for 58.5 kVA DG Set). - The engine shall be fitted with Governor Class G3Instrument Control Panel shall be furnished for the engine, which shall comprise the following:● Push Button ● Water temp. gauge ● Hour meter with rpm indicator ● Lube oil pressure gauge ● Other item as considered necessary by manufacturer The Instrument Control Panel shall preferably be mounted on the Diesel Generator skid. Otherwise it may be of separately pedestal / floor mounted type.GENERATOR / ALTERNATOR:Alternator with rated output of 58.5 kVA at STP suitable for continuous operation at 1500 RPM developing 415 volts at 0.8 p. f. (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless type, drip proof, screen protected as per IP-23, self excited & self regulated. The alternator shall conform to IS: 4722. The salient features of the alternator are: +/- 1% voltage regulation in static conditions. IP 23 protection with class ‘H’ insulation Permissible overload of 10% for one hour in 12 hours of operation●Type : Self excited ● kVA : 58.5 kVA 3 Voltage : 415V, solidly grounded● Phase : 3 phase ● Frequency : 50 Hz ● Power Factor : 0.8 (lagging) ● Excitation System : Brushless exciter ● Insulation Class : Class “H” insulation with temperature limitations for Class-H ● Connection : Star, with neutral terminal wired up to external bushing ●Voltage Regulator : Solid State Electronic typeSTANDARD CONTROL PANEL:The Control Panel shall be fabricated out of steel sheet 1.5 mm thick duly pre-treated and aesthetically finished. It shall be totally enclosed, dust, vermin proof with IP-53 degree of protection as per IS 2147-62. The panel shall consist of following instruments:a) 0 – 600 V, AC Voltmeter of class 1.5 accuracy with phase selector switchb) A.C. Ammeter of Class 1.5 accuracy.c) HRC Fuses of required rating.d) One No MCCB of required rating.e) Frequency Meter.f) Power factor meter.g) Pilot Lampsh) Energy Metrei) Push Button Switch for ON-OFF operation.All the above components shall be properly mounted duly wired and shall be of reputed make.Engine Instrument Panel:The Engine Instrument Panel shall be fitted with starting switch with keys, Lube Oil Gauge, Temperature & Pressure Gauge, Speedometer, Kilowatt Hour Meter etc and all other accessories as required.Safety Control:The D. G. Set shall be provided & fitted with all the safety controls i.e. for Low lube oil Pressure indication switch, High water temperature indication, RPM indication, water temperature indication, battery charging indication etc.Metering ● 3 phase current ● 3 phase voltage ● 3 phase Kilo-watt ● 3 phase KVA ● Kilo-watt hour ● Power factor ● System frequencyStarting Battery Starting battery shall be furnished along with the set, as per following particulars:i)Type : Lead acid ii) Nominal voltage: 12 V D.C.iii) Capacity : Minimum 1 Nos. of 130 AH battery iv) Mounting: Inside the Acoustic Enclosure. v) Battery: The Battery should be same brand as engine to avail single window service.Battery Charger i) Type : SMPS based ii) Charging System : Automatic float and boost chargingiii) Input voltage: 230V 1 phase, 50 Hz. Or 415V, 3 phase, 50 Hz. iv) Capacity: Adequate to restore the fully discharged battery state of full charge in twelve (12) hours.PERFORMANCE REQUIREMENT Performance Requirement ● Nominal output of the set : 58.5 kVA● Rated speed : 1500 rpm ● Rated voltage : 415 volts ● No of phases : 3 ● Rated frequency : 50 Hz ● Overload capacity : 10% for 1 hour ● Over speed withstand capacity : 110% of rated speed for 1 min ● Voltage Regulation : Within +/- 1% of rated voltage from no load to Full load ● Frequency Regulation : Within +/- 4% from no load to full loadTESTS AT SITE DG SET shall be tested at site and diesel (120 Litres) for testing is to be provided by the firm.PACKING ● The materials shall be property packed before dispatch to avoid damage during transport, storage and handling. ● Proper arrangement shall be provided to handle the equipment.INSTALLATION, ERECTION, TESTING AND COMMISSIONING● The generator set, control panel, as well as the neutral of the generator shall be effectively earthed. ●XLPE (L.T 3.5 Core) 50 sq mm 30 mtrs power cabling is to be provided by the contractor . Necessary aluminum power fittings, cable glands, cable end lugs, PVC numbering ferrules, tapes etc. shall be supplied and installed by the contractor.● Residential Silencer and The exhaust pipe upto Silencer shall be provided with each DG Set ● The Supplier shall follow occupational health and safety norms,
61Supply, Installation, Testing and Commissioning of earthing station for D.G SET comprising of company fabricated GI earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip (25x3mm) as per relevant standards.Safe earthing electrode size : 80 mm dia ,Length : 2000 mmBack fill compound : 30 kg
62TOOL KIT For Maintenance: -The Tool Kit for maintenance shall comprise of the following and all the items as mentioned belowshall be of Providing of tool kit consists of following itemsi. Double ended Spanner (Chrome plated) 01 set complete (6-32) sizesii. Double ended Ring spanners chrome plated 01 set complete (6-32) sizesiii. Cutting plier 9 inch -------1 No.iv. Long nose plier; size in mm 205 – 01 No.v. Insulated screw Drivers 12 inch,9 inch, 6inch---------------01 :No. eachvi. Hammer 1 kg--------------------1No. .vii. Heavy duty pipe wrench 24 inch -----------------– 01 No.ix. Providing of chain pipe wrench as per IS 4123-1998 (80mm)viii. Tool box/canvas bag for carriage of tools--------------------01 No.viii. Providng of cordless battery operated impact drill with brushless motor and min torque setting of 1000Nm along with socket set of sizes ranging from 13mm to 24mm.Additonal Features.a. 3-speed settings for torque adjustment.b. 02 No. batteries (min 18V and 4.0AH) along with fast charger.
63Providing of good quality bedding for night stay/Shift consisting of: a) i) Mattress with warm cover size 6'x3' (6Kg)- 02 No’s ii) Quilt with warm cover size 5'x8' (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 01 No, Rice cooker 3 ltr 01 No, Steel patella(utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 16 kg Gas cylinder with burner/ stove. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) locks,Providing of solar/electrical lantern (Andslite) chargeable on both solar & electrical 220v.Supply, providing of foldable aluminium telescopic ladder (22ft) with necessary supports and stabilizers.Fabrication of 4’ x 6’ angle iron bed by way of providing and fitting of Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded. The job also includes providing of 19mm ply sheet of size 4' x 6' Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56223825
AUTHORITY Government Departments
TENDER VALUE 50.35 Lakhs
LAST DATE 09-07-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Supply, Installation, Testing And Commissioning Of Electro-Mechanical Works To Be Executed At Water Supply Facilities Of Hirpora Banimulla For Source Sustainability Under Ut Capex.
Basic Detail
Tender No JSD/PHE/MDSA/ e-NIT No. 09
Bidding Type Tender
Location
City Pulwama
State Jammu and Kashmir
Key Dates
Publish Date 30 Jun 2026
Submission Date 09 Jul 2026
Open Date 10 Jul 2026
Finance
Tender Value 50.35 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Not Available
Document List
4750dd7b-ad4d-4fcd-8a6f-c7dc30b1d5ce.html
BOQ_1016629.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day