Public Administrative Department Government Departments Closing in 4 days TDR #56221321

Tender For Establishment Of Digital Abhuday Education Center For The Students Preparing For Various Competative And Services Exam In District Bahraich

Issued by Government Departments · Bahraich, Uttar Pradesh
Tender Value
1.91 Crore
Estimated cost
Bid Submission
06 Jul 2026
4 days left
EMD
1.91 Lakhs
Bank guarantee accepted
Document Fee
4515
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bahraich → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Establishment Of Digital Abhuday Education Center For The Students Preparing For Various Competative And Services Exam In District Bahraich

BOQ

Name of Work:- ESTABLISHMENT OF DIGITAL ABHUDAY EDUCATION CENTER FOR THE STUDENTS PREPARING FOR VARIOUS COMPETATIVE AND SERVICES EXAM IN DISTRICT BAHRAICH
Sl. No. Item Description
1Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.
2Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
3Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
4Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.
5Construction of drain along with apron. 150X150MM
6Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc,complete.
7(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm.(2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm
8(4) Treatment junction of wall and the floor7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm(6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
9Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources :3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C. work in Plinth Band
10Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).R.C.C. work in Lintel
11As in item no. 7 above but for slabs (Using 1:1.5:3 Mix concrete). M-20
12As in item 7 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) M-20
13Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources :3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C.work in footing
14Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources :3 graded stone aggregate 20 mm nominal size derived from natural sources) R.C.C.work in column
15Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) R.C.C.work in column
16M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
17Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 12.5 mm nominal size).
18Painting on DPC or over roof slab one coat of air blown bitumen 60/70 or 80/100 grade @ one Kg/Sqm including cost of fuel wood other materials, labour T & P etc required forproper completion of work.
19Brick work in super-structure above plinth level including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick.(1:6 cement & coarse sand).
20Half brick masonry with (Class M-150 First Class Brick) in superstructure above plinth level up to floor V level. Cement mortar 1:4(1 cement :4 coarse sand)
21Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
22Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0mm thick glass panes
23Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):Rectangular or square
24TMT Fe-500 iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
2515 mm plinth plaster (1 cement :4 coarse sand) F.M.-2.25
2612mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25
2715 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand.
28Making grooves 10 to12mm wide x 8mm deep in plaster of the wal or in ceilng vertical Ly or horizonta ly as required
29Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12- 20mm nominal size laid in one layer neat cement (40 mm thick floor).
30Supply and fixing of Kota Stone in flooring 25mm thick and joint filled 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12mm base coat (bedding) of 1:2 cement & coarse sand mortar and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour, tools & plants etc required for proper completion of the work. 25mm thick
31Supply and fixing 10 to 12mm thick Kota Stone tiles in skirting or dado laid with 1:2 cement and approved coarse sand mortar finished with in its cement colour slurry, jointing and polished or approved quality complete, including supply of all materials, labour tools & plants etc required for proper completion of teh work. 25mm thick
32Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm.
33Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 15mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm.
34Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
35Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
36Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour andtool sand plants etc.
37Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint ofapproved brand and manufacture
38Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
39Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface)
40Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surfaceeven and smooth complete.
41Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto300 mm height including cleaning the surface before treatment.
42b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs
43c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge :
44With average thickness of 120 mm andminimum thickness at khurra as 65 mm.
45ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion ofwork.
46Fixing of Door, windows/ventilators chaukhats in position.
47Door Chaukhats
48Windows Chaukhats
49Ventilators Chaukhats
50Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
51Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete.(a) 250mm x 16mm .
52Providing and fixing stainless steel towerbolts (barrel type) with necessaryscrews etc. complete
53(a) 250 mm x 10mm
54Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm
55Supply & fixing of flush doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplieddepartmentally. (a) 35mm thick
56(a) Single leaf
57(b) Extra for double leaf doors
58both side laminated
59Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
60Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
61Carpet flooring
62Providing & Fixing of AEROLITE or equivalent make 15mm thick Integral Densified Tegular/Butt edged Eco-Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600mm with Exposed GI Plain T24 Grid: The Eco-Friendly Lightweight Calcium Silicate Ceiling tiles shall be made from Non-Cementitious Hydrated Calcium Silicate Slurry/ Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Does not contain any toxic ingredients. The Tiles should have Humidity Resistance (RH)of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC i.e., Noise Reduction Coefficient 0.5 for Semi Perforated tiles of patterns Spectra/Spin tone/Cosmos/Fine Fissured as per IS 8225:1987, Sound Attenuation (STA) 30-32dB,Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center of the body, Light Reflectance > 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanized iron section of 0.40 mm thick on Silhouette profile, rotary stitched double webbed white with 6 mm reveal profile (white/ black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x1.6 mm galvanized iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
63Gypsum ceilingroviding and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediatechannel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with ecommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed,all complete as per drawings, specification and direction of the Engineerin Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
64Accostic Panelling on walls (Detail attached)
65Centering and shuttering including strutting, propping etc. and removal of form for all heights :
66Foundations, footings, bases of columns, etc. for mass concrete.
67Columns,Pillars, Piers, Abutments, Posts and Struts.
68Lintels, beams, plinth beams, girders, bressumers and cantilevers.
69Suspended floors, roofs, landings, balconiesand access platform.
70Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:-
71White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests.
72Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:-
73W.C. pan with ISI marked white solid plastic seat and lid
74Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
75White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
76Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
77Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
78White Agaria Marble Stone
79Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
80Semi rigid pipe
8140 mm dia
82Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings :
83Size 600x450x200 mm
84Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
85Providing and fixing uplasticised PVC connection pipe with brass unions :
8630 cm length
8715 mm nominal bore
88Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
8915 mm nominal bore
90Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
9115 mm nominal bore
92Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
9315 mm nominal bore
94Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
9515 mm nominal bore
96Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
9715 mm nominal bore
98Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
99Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects.
100Providing & fixing ss finish hand rail for handicap toilet complete in all respects.
101Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
102Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.
103Single socketed pipes.
104110 mm diameter
105Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
106110 mm Bend
107Shoe (Plain)
108110 mm Shoe
109Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
110110 mm
111Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
112Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.
113110 mm dia.
114Providing and fixing floor trap/floor drain of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
115110mm x 110mmX110mm
116Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
117Single 'Y'
118110x110x110 mm
119Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
120Concealed work, including cutting chases and making good the walls etc.
12115 mm dia nominal bore
122Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc
123Internal work - Exposed on wall / Terrace
12420 mm dia nominal bore
12525 mm dia nominal bore
12632 mm dia nominal bore
127Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good thewall :
12820 mm dia nominal bore
129Providing and fixing gun metal gate valve with wheel of approved quality.
13025mm dia nominal bore
131Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
13220 mm dia nominal bore
13325 mm dia nominal bore
13432 mm diameter pipe
135Providing , checking, storing, fixing in position of approved quality Screwed ends Brass float valve with brass ball float and PTFE seat suitable for Body test pressure of 15Kg/sqcm of the following sizes: (Lehry Make)
13640mm dia.
137Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Doemstic Tank =2kl.)
138Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
139Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
140Pipes, cables etc. exceeding 80 mm dia. But notexceeding 300 mm dia
141Providing, laying and jointing glazed stoneware pipes class SP-1with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
142150 mm diameter
143Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
144150 mm diameter S.W. pipe
145Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150x100 mm size P type
146With common burnt clay F.P.S. (non modular) bricksof class designation 7.5
147Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
148Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) :
149With common burnt clay F.P.S. (non modular) bricksof class designation 7.5
150Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work:
15140 mm diameter pipe
152Providing and fixing gun metal gate valve with wheel of approved quality.
15350mm dia nominal bore
154Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
155Group C
156Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
1572x2.5 Sq.mm +1x2.5 Sq.mm
1582x4.0 Sq.mm +1x4.0 Sq.mm
1592 x 6 sq.mm + 1 x 6 sq.mm. earth wire
1602 X 10 sq. mm + 1 X 6 sq. mm earth wire
1614 X 10 sq. mm + 2X 6 sq. mm earth wire
1624 X 16 sq. mm + 2 X 6 sq. mm earth wire
163Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
1642 Pair
165Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
166Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
16720 mm
16825 mm
169Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
170Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1711 or 2 Module (75mmX75mm)
172Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
173Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
174Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
175Group C
176Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
1776 way (4 + 18), Double door
178Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
17912 way , Double door
180Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distributionboard of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar,common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
1818 way (4 + 24), Double doo
182Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required
183Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
184Single pole
185Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
186Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
187Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
188Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
189100 mm width X 50 mm depth X 1.6 mm thickness
190Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
191Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
1928 - 10 watt
19312 -15 watt
194Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3,
19522 watt
19636 watt
197Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KVwith Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K
19818-22 Wat
199Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required.
2001200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum)
201Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good thedamage, connection, testing, commissioning etc. as required
202Upto 450 mm sweep
203supply of 450 mm sweep exhaust fan i
204Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
205Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
206Copper Patch Cords of length 1m (3ft)
207Copper Patch Cords of length 3m (10ft)
208Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted 275 DELHI SCHEDULE OF RATES (E&M)-2025Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.
2092 Run of cable
210Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coatedColor- RAL- 7035, complied with UL & RoHS, 2 x 6sockets 16A power distribution units, 3 numbersclosed cable organizer, Hardware mounting screwspacket of 20 x 1 number, etc. complete as required.
21115U Rack
212Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber
2136 PORT
214Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 276 DELHI SCHEDULE OF RATES (E&M)-2025db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 µm and 125 ± 0.7 µm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required
215Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
216Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.
217Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for nclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
218M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
219Suitable cement concrete foundation duly plastered and with anti vibration pads.
220450 lpm at 35 m Head.
221Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required
2221.2 Meter high and 250 mm dia.
223Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Civil DSR-Cost index 107Rate factor 0.757
224Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia
225Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 80 mm dia
226Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 80 mm dia
227Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 80 mm dia
228Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metalvalve & M.S. Pipe and socket 30M
229SITC weather proof M.S Door and glass fire door size1200 x 450 x 600 mm High or as per arch.
230Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 1200 x 450 x 600 mm High fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: -
231Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed.
2324.5kg capacity cylinder.
233ABC type extinguisher with cylinder fully charged with 6 Kg. capacity.
234Built and camera micTeachmint or equvalnet make 2 neo 98inch IFP 4K UHD 3 years onsitewarranty with google certified Android 14 Edla 8 gb ram / 128 gb storage with classroom connected software , AI integrated with cloud storage NFc card reader and 40 watt speaker with 20 watt subwoofer
235Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/bore log. including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
236300 mm dia 90 metre depth below ground level.
237300 mm dia 90 metre & upto 150 metre depth below ground level.
238Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
239100 mm nominal size dia.
240Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
241100 mm nominal size dia.
242Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
243Development of tube well in accordance with IS: 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
244Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing casing pipe, removable as per requirement, all complete for bore well of:
245100 mm Dia
246Providing and fixing Ball plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part 1).
247100 mm Dia
248Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
24950 mm Dia nominal bore
250Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
251Pumping Set KSB make submersible pump set suitable for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications. (2.00 Н.Р.)
252Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge.
253In all kind of soil upto 1.5m depth
254In all kind of soil upto 1.5m to 3.0m. depth
255In all kind of soil upto 3.0m to 4.5m. depth
256Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size)
257Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand)
258Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.
259Suspended floors, roofs, landings, balconies and access platform.
260P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
26112mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand)
262Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
263Providing and fixing C.I. tee at the inlet and outlet of septic tank.
264Providing & fixing 75mm dia vent pipes.
265Providing & fixing of 75mm dia cast iron terminal guard.
266Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
267M.D. -10- Circular shape 500mm internal diameter
268M.D. -2.5- Circular shape 450mm internal diameter
269Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.
270With F.P.S. bricks
271Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.
272In all kind of soil upto 1.5m depth
273In all kind of soil upto 1.5m to 3.0m. depth
274In all kind of soil upto 3.0m to 4.5m. depth
275In all kind of soil upto 4.5 m to 6.0m. depth
276Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
277Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
278Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.
279Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
280Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
28112mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand)
282Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
283Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
284Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
285Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
286Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
287Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
288Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
289Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
290Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain 244 DELHI SCHEDULE OF RATES (E&M)-2025 pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391as required.
2914.0 TR with 5 Star BEE Rating _lecture hall
292Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original 242 DELHI SCHEDULE OF RATES (E&M)-2025 Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
2931.5 TR with 5 Star BEE Rating _VIP room
2941.5 TR with 5 Star BEE Rating _Staff rooms
2952.0 TR with 5 Star BEE Rating _Library
296BLUE STAR Potable water purification system with inbuilt water cooler. RO BLUE STARR (NST80120B).
297Providing and Supply single Seater Sofa, Wooden Frame , Sear Back Leatherite Tapestry with leatherette finish (HENLY 3 ) design as per incharge of architect
298Providing and Supply 3 Seater Sofa, Wooden Frame , Sear Back Leatherite Tapestry with leatherette finish (HENLY 3 ) design as per incharge of architect
299Providing and Supply Low Back Chair, Cushion Arm, Chrome Base, Gas Lift, Swivel Tilt design as per incharge of architect
300Providing and Supply Chair without Arm, for lecture hall design as per incharge of architect
301Providing and Supply Table, Particle Board Top (SIZE - W1200 X D600 X H750) ,modesty panel design as per incharge of architect
302Providing and Supply Table, Particle Board Top (SIZE - W1000 X D800 X H750) ,modesty panel design as per incharge of architect
303Providing and Supply Table, Particle Board Top (SIZE - W1500 X D800 X H750) ,modesty panel design as per incharge of architect
304Providing and Supply Table, Particle Board Top (SIZE - W3000 X D500 X H750) for lecture hall ,modesty panel design as per incharge of architect
305Providing and Supply Table, Particle Board Top (SIZE - W2000 X D500 X H750) for lecture hall ,modesty panel design as per incharge of architect
306Library storage of size 900 x 450 x 2100
307staff room storage of size 4100 x 450 x 2100
308Side table of size 400x 400x400x
309Center table of size 600 x 600 x400 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56221321
AUTHORITY Government Departments
TENDER VALUE 1.91 Crore
LAST DATE 06-07-2026
Authority
Authority Name Uttar Pradesh Small Industries Corporation Limited
Work Description Tender for Establishment Of Digital Abhuday Education Center For The Students Preparing For Various Competative And Services Exam In District Bahraich
Basic Detail
Tender No 54/CE/26-27
Bidding Type Tender
Location
City Bahraich
State Uttar Pradesh
Key Dates
Publish Date 30 Jun 2026
Submission Date 06 Jul 2026
Open Date 07 Jul 2026
Finance
Tender Value 1.91 Crore
Tender Fee 4515
EMD 1.91 Lakhs
Exemption Not Available
Document List
498fd3af-a73a-4c16-a052-53b4a6e2f327.html
BOQ_2182112.xls
NITBahraich.pdf
Tendernotice_1 (25).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Jul 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

498fd3af-a73a-4c16-a052-53b4a6e2f327.html

xls

BOQ_2182112.xls

pdf

NITBahraich.pdf

pdf

Tendernotice_1 (25).pdf

TenderDetail
Loading tenders