Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56221183

Tender For special Repair To Mt And Gun Sheds (Bldg No P-478 To P-488) & Rewiring Of Officer Mess (Bldg No P-87) Of 53 Med Regt Under Ge (West) Jrc

Issued by Statutory Bodies & Commissions/Committees · Jalandhar, Punjab
Tender Value
43.98 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
19 days left
EMD
87960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Mt And Gun Sheds (Bldg No P-478 To P-488) & Rewiring Of Officer Mess (Bldg No P-87) Of 53 Med Regt Under Ge (West) Jrc

BOQ

Name of Work:- SPL REPAIR TO MT AND GUN SHEDS (BLDG NO P-478 TO P-488) & REWIRING OF OFFICER MESS (BLDG NO P-87) OF 53 MED REGT UNDER GE (WEST) JRC
Sl. No. Item Description
1Demolition of brick work or stone/boulder masonry, built in cement mortar or cement sime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
2M&L for Brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed.
3All as per item No 2 above but except bricks etc. complete all as specified and directed.
4Dismantling structural steel work including doors,gates but excluding framed truss etc.
5M&L for steel rolling shutters without ball bearing as specified including top cover anchoring rod hasp and staple and one coat of primer thickness of latch 1.25mm erected in position as indicated with including gear operated box and crank handle complete all as specified and directed.
6M&L Ball bearing for rolling shutters as specified .
7Petty repair to steel rolling shutters system of any size and any description including repairing of ball bearing, top cover, anchoring rod,hasp and staple, gear operated system, crank handle, chain wheel and hand chain including necessary welding, greesing etc and making the structure complete serviceable all as per existing pattern. complete all as specified and directed.
8M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
9Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
10M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls, finished even and smooth without using extra cement, complete all as specified and directed.
11M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls, finished fair and even, complete all as specified and directed.
12M&L for 5mm thick Rendering in CM 1:3 on brick work or concrete surfaces on ceiling finished even and smooth without using extra cement etc. complete all as specified and directed.
13M&L for preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of primer, complete all as specified and directed.
14M&L for preparation of new plastered surfaces and applying three coats of white wash on wall , complete all as specified and directed.
15M&L for preparation of newly plastered surfaces and applying three coats of White Wash on ceiling etc. complete all as specified and directed.
16All as per item No. 15 above but over old surfaces of ceiling, including removal of existing treatment. complete all as specified and directed.
17M&L for preparation of old plastered surfaces including removal of existing treatment and applying three coats of white wash on wall, complete all as specified and directed.
18M&L for complete removal of existing treatment and applying two coats of cement base paint, complete all as specified and directed.
19M&L for preparation of old painted surfaces of steel of any description not other wise described over 10cm width or girth and applying one coats of synthetic enamel paint all as specified.
20Repairing of RCC projections chajjas, roofs, facia etc by necessary preparation, scrapping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC and providing cement concrete (1:1.5:3) using 12.5 mm graded crushed stone aggregate including necessary form work and reinforced with chicken wire mesh and rendering 15mm thick in cement mortar 1:3 in patches area not exceeding 5 sqm each and thickness of RCC member not exceeding 100mm at any height complete all as specified and directed.
21Taking down carefully aluminium / copper point wiring (light / fan / socket or power) while not disturbing existing conduit complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls and floors and one coat of putty and two coat of distemper as per existing colour complete all as directed.
22Taking down sub main wiring of two single core PVC cable PVC insulated 4 / 6/10 sqmm including conduit or wooden batten and remove from the site of work and making good the disturbed surfaces of wall or floor etc. and one coat of putty and two coat of distemper as per existing colour complete all as directed.
23Taking down main switch / DB and making good the disturbed surface and one coat of putty and two coat of distemper as per existing colour complete all as directed.
24M&L for point wiring with 1.5 sqmm, PVC insulated but sheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit medium grade 20mm dia (minimum) or higher size as specified and cutting chasing on wall/ground complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc/ fittings ISI marked for modular fittings and brass screws and cup washers including 1.5 sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed. Note : 1. Cost of Metal boxes and modular accessories like cover plates will be paid seprately in respective items) 2. Wiring has to be done in the Sheds having Length more than 100 meter, width up to 20 meter and height up to 10 meter.(a) Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push.
25(b) One socket outet point 5 amps on the same board.
26(c) One socket outet point 5 amps on the independent board.
27All as Ser item 24 here in before but with 2.5 sq mm wire and earth wire (green colour) of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet.
28Supply and fixing modular metal flush box 1/2 module complete all as specified and directed.
29Supply and fixing modular metal flush box 3 module complete all as specified and directed.
30Supply and fixing modular metal flush box 4 module complete all as specified and directed.
31Supply and fixing modular metal flush box 6 module complete all as specified and directed.
32Supply and fixing modular metal flush box 12 module complete all as specified and directed.
33Supply and fixing modular white cover plate with frame, 1 module complete all as specified and directed.
34Supply and fixing modular white cover plate with frame, 3 module complete all as specified and directed.
35Supply and fixing modular white cover plate with frame, 4 module complete all as specified and directed.
36Supply and fixing modular white cover plate with frame, 6 module complete all as specified and directed.
37Supply and fixing modular white cover plate with frame,12 module complete all as specified and directed.
38Supply and fixing modular Dummy plate complete all as specified and directed.
39Supply and fix in repair Modular switch 6 Amps single pole one way as per existing make & model/ as per sample.
40Supply and fix in repair Modular switch 16 Amps single pole one way as per existing make & model/ as per sample.
41Supply and fix Modular multi socket 3 pin and 2 pin 6 Amps round and flat as per existing make & model/ as per sample.
42Supply and fix in repair Modular socket 6A /16 A Twin socket heavy duty as per existing make & model/ as per sample.
43Supply & fixing ceiling roses surfaces bakelite two three terminals 65 x 50 mm all as specified.
44Supply & fixing lamp holder PVC, insulated body with back plate suitable for batten fittings including LED lamp 9W BEE Energy star rating of five star all as specified.
45Supply and fix in repair modular/BLDC fan regulator step type 240 V, 120 W, 2 modules all as as per existing make & model/ as per sample.
46Supply and Fixed single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of cap 20A complete all as specified and directed.
47Supply & fixing of 20 Watt Batten luminaire with Polycarbonate Housing with high quality opal finish diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an System efficacy of at least 100 lumen/watt and maximum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
48S & F SITC of high-quality integrated LED Street Light with a minimum system lumen of4750 Lm and system wattage not exceeding 45W with a nominal efficiency 105 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/ULaccredited lab to verify above parameters complete all as specified and directed.
49S & F of SITC of high-quality integrated LED Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 60W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
50S & F SITC of high-quality LED Flood Light with a minimum system lumen of 6000 Lm and system wattage not exceeding 50 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with CRI >70. The housing should be of pure polyester powder coated die-cast aluminum with high efficiency LEDs as lighting source. The fitting should have PC reflector for maximum output and PC Lens for symmetric distribution & tempered protective Toughened Glass with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 6 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
51S&F SITC of high-quality LED Flood Light with a minimum system lumen of 12000 Lm and system wattage not exceeding 100 W with a nominal efficiency 120 lumen/watt. CCT of 5700K with CRI >70. The housing should be of pure polyester powder coated die-cast aluminum with high efficiency LEDs as lighting source. The fitting should have PC reflector for maximum output and PC Lens for symmetric distribution & tempered protective Toughened Glass with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 6 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
52S & F high speed wall mounted fan of sweep size 450 mm copper winded complete with wide oscillation with motorised control including fitting and fixtures as per site requirement and two core PVC insulated, PVC sheathed copper conductor for connection all as specified and directed. Make : Crompton/Havells or equivalent
53Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
54S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
55Supply and fix Sheet metal DB,double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc complete all as specified and directed. Make : EKINOX3 series of Legrand/Acti 9 metalic series of Schneider /Osafe series of HPL/Metallica of Havells/Hager/L&T/Siemens
56Supply and fix Sheet metal DB,Single door, SPN 4 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc complete all as specified and directed. Make : EKINOX3 series of Legrand/Acti 9 metalic series of Schneider /Osafe series of HPL/Metallica of Havells/Hager/L&T/Siemens
57S/F MCB TPN 40 Amps 415 volts as per Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
58Supply and fix MCCB 63 Amps 4 pole 415 Volt,25 KA breaking capacity conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
59Supply and fix MCB DB, TPN 4 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus bars, Neutral links, blanking plates conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
60Supply and fix MCCB 100 Amps 4 pole 415 Volt,25 KA breaking capacity conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
61Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus bars , Neutral links , blanking plates conforming to Osafe of HPL / Acti 9 series of Schneider /Ekinox3 of Legrand /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
62M & L for sub main wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 10 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 10 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed. Including taking down old unserviceable sub main wiring. Note : Four runs of 10 sqmm PVC FRLS multi stranded copper cable wire and One run of 10 sqmm PVC FRLS multi stranded copper cable earth wire and One run (01 meter) PVC conduit of suitable size ISI mark will be measured and one unit length.
63M&L for earthing complete with GI steel earth plate electrod 60x60cmx6.00mm thick bouried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4 mm as earthing lead soldering/revated to earth plate at one end and connected DB by means of nut, bolts etc complete with PCC pit (1:3:6) type GI cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead all complete as specified and as per electric plate No.5 of SSR Part I
64Taking down unserviceable Cable of any size as directed.
65Supply and laying XLPE insulated, armoured electric cable heavy duty with aluminium conductor,1100 volts UG cable of size 4 Core 35 Sqmmm complete as specified and directed.
66Supply and laying XLPE insulated, armoured electric cable heavy duty with aluminium conductor,1100 volts UG cable of size 4 Core 25 Sqmmm complete as specified and directed.
67Supply and laying XLPE insulated, armoured electric cable heavy duty with aluminium conductor,1100 volts UG cable of size 2 Core 25 Sqmmm complete as specified and directed.
68Excavation in trenches in soft/lose soil not exceeding 1.5 Mtr wide and not exc 1.5M depth for laying of UG cables and getting out all as specified and directed.
69Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms thick of soil complete all as specified and directed.
70M & L river sand in trenches as cable cushioning 8 cm below the cables and 15cm above the cable which is to be punned down to 10m all as specified and directed. Only punned thickness will be measured.
71Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed.
72Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed.
73Supply and fixing /laying PVC conduit pipe 50 mm bore light grade fixed to pole with clamps nuts, Bend/Tee/Junction box , bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed.
74Supply and fix Bed side Reading light with all electrical connection as required all as specified and directed.
75Supply & fixing decorative wall light fixture made up of polycarbonate/glass including LED lamp 9W BEE Energy star rating of five star warm/white all as specified and directed.
76S & F surface mounted LED Battern with LED tube rod 2 Feet 10W internal surge protection device of 4 KV with voltage band 140-280V and making electrical connection to ceiling rose all as directed.
77Supply & fixing of 14 Watt Batten luminaire with Polycarbonate Housing with high quality extruded polycarbonate diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2100 nominal lumens and an outstanding System efficacy of at least 150 lumen/watt and maximum system wattage of 14 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <15% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
78Supply & fixing of Recess LED 2x2 luminaire with CRCA powder coated housing suitable with high transmittance opal diffuser for glare free symmetric lightb distribution for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 4000/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and an outstanding System efficacy of atleast 120 lumen/watt and maximum system wattage of 30 Watts.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% , EMC EMI CISPR 15 complaint, Ripple <5% (Flicker Free), Short-circuit protection, 4KVA Surge and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Please Enable Macros to View BoQ information
79Supply & fixing of Recess LED 2x2 luminaire with CRCA powder coated housing suitable with high transmittance opal diffuser for glare free symmetric lightb distribution for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 4000/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and an outstanding System efficacy of atleast 120 lumen/watt and maximum system wattage of 30 Watts.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% , EMC EMI CISPR 15 complaint, Ripple <5% (Flicker Free), Short-circuit protection, 4KVA Surge and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56221183
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.98 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Mt And Gun Sheds (Bldg No P-478 To P-488) & Rewiring Of Officer Mess (Bldg No P-87) Of 53 Med Regt Under Ge (West) Jrc
Basic Detail
Tender No GE/JAL(W)-14/2026-27
Bidding Type Tender
Location
City Jalandhar
State Punjab
Key Dates
Publish Date 30 Jun 2026
Submission Date 20 Jul 2026
Open Date 27 Jul 2026
Finance
Tender Value 43.98 Lakhs
Tender Fee 500
EMD 87960
Exemption Available
Document List
af0b5780-5ca3-48c8-86fb-9958c1c9da85.html
BOQ_868303.xls
TenderDocuments14.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Jul 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

af0b5780-5ca3-48c8-86fb-9958c1c9da85.html

xls

BOQ_868303.xls

pdf

TenderDocuments14.pdf

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders