Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #56221123

Tender For Illumination Of Nemai Tirtha Ghat In Connection With Shrabani Mela 2026 At Tarakeshwar.

Issued by Local Bodies · Hooghly, West Bengal
Tender Value
9.40 Lakhs
Estimated cost
Bid Submission
07 Jul 2026
6 days left
EMD
18811
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hooghly → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Illumination Of Nemai Tirtha Ghat In Connection With Shrabani Mela 2026 At Tarakeshwar.

BOQ

Name of Work:- Illumination of Nemai Tirtha Ghat in connection with Shrabani Mela 2026 at Tarakeshwar.
Sl. No. Item Description
1Supply & Fixing of double arm projected lamp bracket (Single pip bending) of 50mm (2\\") dia G.I. pipe (ISI medium) of 2.5 mtr long each having 105 degree curvature with reducing socket to be fitted at the top of the pole with bolts, nuts clamps etc. as required.
2Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection,EMI EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
3a) 120 Watt
4Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
5a) 250 Watt
6Supply and fixing of Sky Cove LED strip light (5M length) with driver and necessary connection as per direction of EIC.
7Supplying and Fixing waterproof looping cable box/ junction box having one 250 V, 6 A SP MCB and housing the same in pole incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting as per direction of EIC.
8a) 250 x 200 x 105 mm
9Earthing with one 15.88mm dia GI rod with double GI nuts and washers and 4 SWG GI wire to an average depth of 3 mtr.
10a) With 1.8mtr long earth spike.
11Supplying & Erection of mini size feeder pillar box of Size (918 x 561 x 382 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5\\" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of EIC.
12Supplying and Drawing 1.1KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
13a) 3 x 22/0.3 (1.5 mm²)
14b) 3 x 56/0.3 (4 mm²)
15Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
16a) 40 mm dia
17Supply of 1.1KV grade XLPE insulated Armoured/ Un-armoured Al. conductor cable.
18(a) Cable size: - 4 Core 10 mm² Armoured
19(b) Cable size: - 4 Core 10 mm² Un-armoured
20Laying only Cable upto 50 sqmm through existing RCC/ Hume/ GI Pipe/ open masonary trench for single, 2, 3, 3½ & 4 core.
21(a) Cable size: - 4 Core 10 mm² Armoured.
22Supply & installation of permanent catenary cabling arrangement of street light pole with following size unarmoured PVC / XLPE insulated cable (cable supplied seperately), 7/18 stranded G.I. wire after binding the same on real insulator with necy. Al. binding wire and fixing the same to Galv. 'D' iron clamp, straining screw arrangement on pole as per direction of EIC.
23Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
24(a) Cable size: - 4 Core 10 mm² Un-armoured.
25Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
26(a) Cable size: - 4 Core 10 mm² Armoured
27Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
28(a) Cable size: - 4 Core 10 mm² Armoured, Un-Armoured
29Sub-Total = 7,89,189.00
30Add LWC @ 1%
31Sub-Total = 7,97,080.89
32Add GST @ 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56221123
AUTHORITY Local Bodies
TENDER VALUE 9.40 Lakhs
LAST DATE 07-07-2026
Authority
Authority Name Kolkata Metropolitan Development Authority
Work Description Tender for Illumination Of Nemai Tirtha Ghat In Connection With Shrabani Mela 2026 At Tarakeshwar.
Basic Detail
Tender No 07 / EE / ED-I / EM / KMDA / T-2 of 2026-27
Bidding Type Tender
Location
City Hooghly
State West Bengal
Key Dates
Publish Date 30 Jun 2026
Submission Date 07 Jul 2026
Open Date 09 Jul 2026
Finance
Tender Value 9.40 Lakhs
Tender Fee Ref. Documents
EMD 18811
Exemption Not Available
Document List
BOQ_2529237.xls
eaf37b2b-ccff-4050-8ad3-27052582a4db.html
Tendernotice_1 (14).pdf
TENDER_DOCUMENTS.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2529237.xls

html

eaf37b2b-ccff-4050-8ad3-27052582a4db.html

pdf

Tendernotice_1 (14).pdf

pdf

TENDER_DOCUMENTS.pdf

TenderDetail
Loading tenders