Tender For Illumination Of Nemai Tirtha Ghat In Connection With Shrabani Mela 2026 At Tarakeshwar.
Tender Value
9.40 Lakhs
Estimated cost
Bid Submission
07 Jul 2026
6 days left
EMD
18811
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hooghly → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Illumination Of Nemai Tirtha Ghat In Connection With Shrabani Mela 2026 At Tarakeshwar.
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Fixing of double arm projected lamp bracket (Single pip bending) of 50mm (2\\") dia G.I. pipe (ISI medium) of 2.5 mtr long each having 105 degree curvature with reducing socket to be fitted at the top of the pole with bolts, nuts clamps etc. as required. |
| 2 | Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection,EMI EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 3 | a) 120 Watt |
| 4 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 5 | a) 250 Watt |
| 6 | Supply and fixing of Sky Cove LED strip light (5M length) with driver and necessary connection as per direction of EIC. |
| 7 | Supplying and Fixing waterproof looping cable box/ junction box having one 250 V, 6 A SP MCB and housing the same in pole incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting as per direction of EIC. |
| 8 | a) 250 x 200 x 105 mm |
| 9 | Earthing with one 15.88mm dia GI rod with double GI nuts and washers and 4 SWG GI wire to an average depth of 3 mtr. |
| 10 | a) With 1.8mtr long earth spike. |
| 11 | Supplying & Erection of mini size feeder pillar box of Size (918 x 561 x 382 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5\\" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of EIC. |
| 12 | Supplying and Drawing 1.1KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. |
| 13 | a) 3 x 22/0.3 (1.5 mm²) |
| 14 | b) 3 x 56/0.3 (4 mm²) |
| 15 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. |
| 16 | a) 40 mm dia |
| 17 | Supply of 1.1KV grade XLPE insulated Armoured/ Un-armoured Al. conductor cable. |
| 18 | (a) Cable size: - 4 Core 10 mm² Armoured |
| 19 | (b) Cable size: - 4 Core 10 mm² Un-armoured |
| 20 | Laying only Cable upto 50 sqmm through existing RCC/ Hume/ GI Pipe/ open masonary trench for single, 2, 3, 3½ & 4 core. |
| 21 | (a) Cable size: - 4 Core 10 mm² Armoured. |
| 22 | Supply & installation of permanent catenary cabling arrangement of street light pole with following size unarmoured PVC / XLPE insulated cable (cable supplied seperately), 7/18 stranded G.I. wire after binding the same on real insulator with necy. Al. binding wire and fixing the same to Galv. 'D' iron clamp, straining screw arrangement on pole as per direction of EIC. |
| 23 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. |
| 24 | (a) Cable size: - 4 Core 10 mm² Un-armoured. |
| 25 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 26 | (a) Cable size: - 4 Core 10 mm² Armoured |
| 27 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 28 | (a) Cable size: - 4 Core 10 mm² Armoured, Un-Armoured |
| 29 | Sub-Total = 7,89,189.00 |
| 30 | Add LWC @ 1% |
| 31 | Sub-Total = 7,97,080.89 |
| 32 | Add GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 days