Tender For Repair And Maintenance To Geyser, Ceiling Fans, Exhaust Fans And Domestic Ro Etc Work In Certain Building At Hq 10 Sector repair renovation And 29 repair renovation At Pattan Garrison Under Age (I) Cif (K)
Tender Overview
Project Description
Tender for Repair And Maintenance To Geyser, Ceiling Fans, Exhaust Fans And Domestic Ro Etc Work In Certain Building At Hq 10 Sector repair renovation And 29 repair renovation At Pattan Garrison Under Age (I) Cif (K)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-Jul-2026 | BOQ | BOQ | 21-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws, canopy screws of suitable size and ensuring all blades screwed properly before refixing including replacement of PVC fan box round sheet as required on site and making electric connection with flexible copper conductor of size 3 core 0.50 Sqmm complete all as specified and directed.(Note:- Rewinding and unserviceable parts other than specified in this item if any will be measured seperately). |
| 2 | M & L for taking down, opening, dismantling and taking out burnt winding wire by cutting, cleaning slots and re-winding of AC ceiling fan motor 1400/1200mm sweep any make with super enameled colour copper winding wire of gauge 35/36 SWG including, sleeve work, varnishing with 1st class insulation paper with threading complete all as specified and directed.Note:- Total weight of winding wire should not be less than 200gm Per fan.Make of winding wire: RR/ BIC/ Devidyal/ Swastik or equivalent make as per command approved list. |
| 3 | Servicing of Exhaust fans of size upto 750 mm sweep including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws of suitable size and ensuring fan blades screwed properly before refixing and making electric connection with flexible copper conductor of size 3 core 0.50 Sqmm complete all as specified and directed. (Note:- Rewinding and unserviceable parts other than specified in this item if any will be measured seperately). |
| 4 | M & L for taking down, opening, dismantling and taking out burnt winding wire by cutting, cleaning slots and re-winding of exhaust fan/wall mounted fan motor upto 450mm sweep with super enameled copper winding wire of gauge as per existing and approved from engr-in-charge before fitted including cutting and getting out old brunt winding, sleeve work, varnishing with E class insulation varnish, threading complete all as specified and directed. |
| 5 | Supply & fixing only for replacement of old unserviceable gun metal bush of ceiling fan of size 1200/1400mm sweep as per existing size complete all as specified and directed. |
| 6 | Supply & fixing only for replacement of old unserviceable capacitor AC 440 volts 2.5 mfd with copper wire terminal including PVC clamp complete all as specified and directed. |
| 7 | All as per Srl item No 6 above but of rating 3.15mfd. |
| 8 | Supply & fixing ball bearing suitable for ceiling fan/exhaust fan/wall/pedestal fan any type complete all as specified and directed. |
| 9 | Supply & fixing only for replacement of old unserviceable shackle assembly kit (rubber real -01, MS split clamp -02 Nos, nut ,check nut,spring washer, bolt not less tha 6.0mm dia & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed. |
| 10 | Supply & fixing only in replacement of old unserviceable ceiling fan blades made of MS sheet duly powder coated of thickness not less than 1.0mm suitable for 1400/1200mm sweep ceiling fan complete all as specified & directed. |
| 11 | Supply and fixing down rod made of MS pipe medium grade 15mm dia of 300/600mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to down rod with spray painted two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 12 | Supply and fixing in replacement PVC canopy for ceiling fan of suitable size complete all as specified and directed. |
| 13 | S&F in replacement of Metallic casing (upper and lower) for housing ceiling fan motor of size required at site for ceiling fan 1200mm/1400mm sweep made out of powder coated CRCA sheet complete all as specified and directed. |
| 14 | Supply and Fixing in replacement cable PVC insulated and overall sheathed with flexible copper conductor 3 core of size 0.5 sqmm |
| 15 | M & L for Removing old paint by scraping with sand paper including washing and filling cavities with filler and applying two coats of painting with existing colour to ceiling fan 1200-1400mm sweep at site with heat resistant synthetic enamel paint by spray painting on the ceiling fans complete all as specified and directed by Engr-in-Charge. |
| 16 | M & L for Removing old paint by scraping with sand paper including washing and filling cavities with filler and applying two coats of painting with existing colour to Exhuast fan upto 750mm sweep alongwith connected part at site with heat resistant synthetic enamel paint by spray painting incl on the Exhuast fan complete all as specified and directed by Engr-in-Charge. |
| 17 | M & L for Replacement of old unserviceable electronic fan regulator stepped type hum free heavy duty 230 volts on existing laminated sheets complete |
| 18 | Supply and replace existing unserviceable Metallic shutter of exhaust fan as per existing size & shape complete all as specified and directed. |
| 19 | Supply and replace existing unserviceable PVC fan blade of exhaust fan as per existing size & shape complete all as specified and directed. |
| 20 | M & L for lathe work of Ceiling Fan/ Exhaust fan of any capacity and make incl re-alignment to rotor, stater sloter, cleaning welding , bracing and polishing etc and refixing after repair and testing complete all as specified and directed by Engr-in-Charge. |
| 21 | Replacement of old unserviceable outer PVC body of exhuast fan alongwith shutter cover plate of size upto 300mm including all fitments such screws, gasket cover canopy of both side etc complete |
| 22 | S & F as in replacement of motor of Exhuast fan upto 450mm sweep Metallic body 230 volts 50Hz 900 RPM (ISI Marked) with copper winding complete all specified and directed. |
| 23 | M&L for replacement of old unserviceable outer Metallic body of exhuast fan alongwith connected support arm and body frame of size upto 449mm including all fitments such screws, gasket cover canopy of both side etc complete |
| 24 | Taking down carefully from wall after unscrewing nut/bolts geysers 50/25 ltr capacity and strip opening the same for taking out internal tank, syphon assembly etc and re-assembling and re-fixing after repair servicing unserviceable spares parts to be replaced including descaling of water storage tank and testing complete Note :- Supply and replacement of spare components shall be measured and paid for separately under the respective items as given here-in-after. |
| 25 | Supply and replacement of internal glass lined/enameled/ titanium coated, SS 304 steel water tank with 0.7 Mpa bar pressure conforming to IS as per site requirement of geyser 50 ltr capacity complete with syphon–assembly, 1.5 kw element , rubber gasket , thermostat switch , all as specified and directed. The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor. Tank with stud type round element shall only be used . (Triangular element shall not be allowed .) |
| 26 | Supply and replacement internal glass lined/enameled/ titanium coated, SS 304 steel water tank with 0.7 Mpa bar pressure conforming to IS as per site requirement of geyser 25 ltr capacity complete with syphon –assembly, 1.5 kw element , rubber gasket , thermostat switch , all as specified and directed. The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor . Tank with stud type round element shall only be used . (Triangular element shall not be allowed .) |
| 27 | Supply and fix in replacement of syphon assembly of 6 hole/09 holes as per site requirement made out of brass of 50 ltr capacity (ISI marked) including necessary studs screws and rubber gasket/washers complete all as spd and directed. |
| 28 | All as per Srl item No. 27 above but 25/35 ltr capacity. |
| 29 | Supply and fix in replacement of thermostat switch (ISI marked) suitable for geyser 25 ltr to 50 ltr, AC 230 volt adjustable range from 0-90 degree Celsius as per exisiting size, make and shape complete all as specified and directed. |
| 30 | Supply and fix in replacement of heating element titanium coated of rating 1.5/2 KW suitable for geyser any type and make as per existing and site requirement incl gasket washer (ISI marked) geyser element AC 230 volt complete all as specified and directed. |
| 31 | S&F in replacement heating element, titanium coated of rating 1.5 KW suitable for water heater storage type combination with syphon assembly and thermostat complete (Round / Oval /Square type a directed by engr-in-charge for 5 star rated geyser as per sample with existing one) of any make and description as required at site including rubber washers (ISI Marked), complete all as specified and directed by Engineer-in-Charge. |
| 32 | S & F in replacement of outer body suitable for 50 ltr geyser with rust proof made out of CRCA sheet (16 gauge) 1.5 mm thick electro statically powder coated stove enamelled factory made complete with fixing bracket matching with existing and nuts and bolts to fixed to wall complete all as specified and directed. |
| 33 | S & F in replacement of outer body suitable for 25 ltr geyser with rust proof made out of CRCA sheet (16 gauge) 1.5 mm thick electro statically powder coated stove enamelled factory made complete with fixing bracket matching with existing and nuts and bolts to fixed to wall complete all as specified and directed. |
| 34 | S & F in replacment of indicator lamp (green and red ) with neon lamps (ISI marked ) indicating automatic working of geyser round/square type as per existing and suitable for geyser 25/50 ltr all as per sample AC 230 Volt complete all as spd and directed. |
| 35 | Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 2.5 sqmm (ISI marked ) 1100 volts grade. |
| 36 | S & F in replacment of geyser connections pipes for hot & cold water supply made out of stainless steel wire braided connector with crome finish heavy duty nuts of 15 mm dia size with suitable length and as per existing site condition incl taking down of old UNSV pipes complete all as specified and directed. |
| 37 | Supply and fixing anchor bolt 12mmX100mm long complete all as specified and directed (Note:- Anchor bolt shall be grouted with hammer drill only) |
| 38 | M & L for preparing the old painted steel surface by rubbing/scratching the old paint and painting with the two coats of synthetic enameled paint white with spray gun incl MES No with black paint of required size and shape complete of 50 ltr geyser. |
| 39 | All as per Srl item No. 38 above but 25 ltr capacity |
| 40 | S&F in replacement top /bottom cover Plate along with screws for outer body of geyser 25-50 Ltrs capacity complete all as specified and as directed by the Engineer-in-Charge. |
| 41 | S&F in replacement of safety valve (ISI marked ) suitable for 25 ltr to 50 Ltr geyser capacity as per site requirement and shape and size complete with all as specified and directed |
| 42 | S&F in replacement of spring loaded air release valve (ISI marked ) suitable for 25 ltr to 50 Ltr geyser capacity as per site requirement shape and size complete with all as specified and directed |
| 43 | S&F in replacement of fusible plug (ISI marked ) suitable for 25 to 50 Ltr geyser capacity as per site requirement shape and size complete with all as specified and directed |
| 44 | S&F in replacement of non return valve (ISI marked ) suitable for 25 ltr to 50 Ltr geyser capacity made out of brass for bore dia of pipe 15 mm dia and as per site requirement and shape and size complete with all as specified and directed |
| 45 | S&F in replacement of high density PUF insulation material non hygroscopic , fire resistant , for suitable for 25 to 50 ltr cap geyser complete with taking out old material coomplete all as specified and directed. |
| 46 | Replacement old unserviceable and providing new internal glass lined/enameled/ titanium coated, SS 304 steel water tank with 0.7 Mpa bar pressure, suitable for geyser 25 ltr capacity complete with rubber gasket, complete all as specified and directed by Engineer-in-Charge Notes :- (i) The tank shall be tested at site and shall be able to withstand requisite pressure, necessary arragengments for the testing shall be made arranged by the contractor. (ii) Tank with stud type and round element shall only be provided and trianguluar element shall not be accepetable. |
| 47 | M & L for point wiring for geyser with 4.00 sqmm in PVC insulated copper conductor cable ( multistrand) single core PVC insulated cable in existing PVC concealed conduit terminated in new sunken pressed steel boxes of suitable size as required at site including inner and outer frame plate for mounting of switches/socket and continuous earth wire 4.00 Sqmm copper cable PVC insulated controlled by one switch for 15 Amp sockets point independent all as specified and directed by Engr-in-Charge. (Note:- In ceiling Portion surface conduit wiring to be done). |
| 48 | S & F in replacment of single pole and neutral enclosure with two pin and earth plug industrial type socket complete with one single pole MCB 20 Amp C curve type 230 volts 10 KA complete with fixing to wall by cutting, chasing of wall and making surface good as per existing matching to colour and finish work complete all as spd and directed. |
| 49 | S & F in replacement of Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed bore dia of pipe 15 mm. |
| 50 | Supply and fix Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm dia or for unions and fixed. |
| 51 | M & L for 3-layer PR-(Polyropylene random copolymer) concealed pipe SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass theraded polypropylence random fitting laid in wall/ceiling of size 16mm outer dia incl cutting the wall and making good to distrub surfaces of wall/floor to match to existing finishes etc complete all as specified and directed. complete all as specified. |
| 52 | Supply and fixing in replacement of old unserviceable and providing new internal glass lined/enameled/titanium coated, SS 304 steel water tank with 0.7 Mpa bar pressure, suitable for geyser 50 ltr capacity complete with rubber gasket, complete all as specified and directed by Engineer-in-Charge Notes :- (i) The tank shall be tested at site and shall be able to withstand requisite pressure, necessary arragengments for the testing shall be made arranged by the contractor. (ii) Tank with stud type and round element shall only be provided and trianguluar element shall not be accepetable. |
| 53 | Taking down & up and supply and fixing in replacement of unserviceable consumable items of reverse osmosis water purifier of capacity 500 LPH (including taking down & up) complete as per satisfaction of users all are specified and directed for the follwings Make :-Aquaguard or as per norms |
| 54 | (a) Big Blue 20 inch Jumbo sediment filter with housing and others |
| 55 | (b) Big Blue 20 inch SPUN filter |
| 56 | (c) 10\\" UF Membrane |
| 57 | (d) 4040 Hydranautic Reverse Osmosis membrane top quality |
| 58 | (e) Chemical cleaning of RO Membrane. |
| 59 | (f) 1 HP motor rewinding . |
| 60 | (g) 2 HP High Pressure pump motor rewinding . |
| 61 | (h) Capacitor of 2 HP motor set. |
| 62 | (i) Relay of 2 HP motor set. |
| 63 | (j) Material and labour for rectifying any type of blockage of any filters of RO or any loose connection in electric and electronic component, complete all as specified and directed at site by Engr-in charge. |
| 64 | Taking down & up and supply and fixing in replacement of unserviceable consumable items of reverse osmosis water purifier of capacity 50 LPH (including taking down & up) complete as per satisfaction of users all are specified and directed for the follwings Make :-Aquaguard or as per norms |
| 65 | (a) Plane Filter 20 inch long. |
| 66 | (b) Activated Carbon filter 20\\" long. |
| 67 | (c) Carbon block granule 20\\". |
| 68 | (d) Solenoid valve |
| 69 | (e) Booster pump 150 SPD |
| 70 | (f) AC /DC Adopter 48Volts |
| 71 | (g) RO membrane ( closed/open) |
| 72 | (h) UV ballast . |
| 73 | (i) Ultra violet lamp . |
| 74 | (j) UV cartridge . |
| 75 | (k) Low pressure switch |
| 76 | (l) TDS valve |
| 77 | (m) Rejector valve |
| 78 | (n) PVC pipe of size 4mm/8mm with connectors |
| 79 | (o) Big Blue 20 inch Jumbo sediment filter |
| 80 | (p) Big Blue 20 inch Jumbo sediment filter with housing and others |
| 81 | (q) In line carbon 10\\" long |
| 82 | (r) Material and labour for rectifying any type of blockage of any filters of RO or any loose connection in electric and electronic component, complete all as specified and directed at site by Engr-in charge. |
| 83 | M & L for taking down, opening, dismantling and taking out burnt winding wire by cutting, cleaning slots and re-winding of Centrifugal Monoset Pump of 15 HP motor of any make with super enameled colour copper winding wire of gauge 35/36 SWG including, sleeve work, varnishing with 1st class insulation paper with threading complete all as specified and directedMake of winding wire: RR/ BIC/ Devidyal/ Swastik or equivalent make as per command approved list. |
| 84 | Note :- An amount of Rs. Rs 35,725.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender