Tender For Repair And Maintenance To Ac, Refrigerators And Other Connected Work Of 663 R&O And Hq 10 Sector repair renovation And 29Rr Under Age (I) Cif (K)
Tender Value
8 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
20 days left
EMD
16000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance To Ac, Refrigerators And Other Connected Work Of 663 R&O And Hq 10 Sector repair renovation And 29Rr Under Age (I) Cif (K)
BOQ
| Sl. No. | Item Description |
| 1 | SHALATENG GARRISON |
| 2 | Dismantling and lowering to ground for repair, inspecting defective parts of Window and split type AC of capacity 1.5 and 2 Ton and re-installing the same after repair and descaling of condenser and servicing complete, testing to the complete satisfaction of Engr-in-Charge |
| 3 | Taking out the existing burntout compressor and supply & replacement of compressor sealed unit suitable for ACs 1.5 Ton capacity including flushing, vaccumising and hydration the system, leakage testing, welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including including replacement of strainer complete all as directed.Make- Kirloskar/ Tecumseh |
| 4 | Taking out the existing burntout compressor and supply & replacement of compressor sealed unit suitable for ACs 2 Ton capacity including flushing, vaccumising and hydration the system, leakage testing, welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including including replacement of strainer complete all as directed.Make- Kirloskar/ Tecumseh |
| 5 | Material and labour for charging of gas in window type AC 1.5/2 Ton after flushing, vaccumising and hydration as per laid down standard practice including replacement of copper strainer complete as directed. |
| 6 | Material and labour for charging of gas in split ype AC 2 Ton after flushing, vaccumising and hydration as per laid down standard practice including replacement of copper strainer complete as directed. |
| 7 | Supply and replacement of blower motor of size 1/10 HP for Air Conditioner of capacity 1.5 Ton as per existing model of approved make. Make: NDO AIR MASTER/FRAC MASTER |
| 8 | Supply and replacement of running capacitor 36 mfd. Make-TIBCON/SIEMENS. |
| 9 | Supply and replacement of running capacitor 45 mfd. Make-TIBCON/SIEMENS. |
| 10 | Supply and replacement of starting capacitor of size 100-120 MFD for Air Conditioner upto 2 Ton Capacity. Make-TIBCON/SIEMENS. |
| 11 | Supply and replacement of starting capacitor of size 80-100 mfd. Make-TIBCON/SIEMENS. |
| 12 | Supply and replacement of box type relay type Model Sr-1622 for Air Conditioner 1.5 Ton/2 Ton capacity as per sample approved by department complete all as directed. Make-SHRIRAM/RANUTROL. |
| 13 | Supply and replacement of air filter of window/ split type AC suitable AC 1.5/2 Ton Capacity.Male-BLUESTAR/VOLTAS/FEEDER LLOYD |
| 14 | Supply and replacement of thermostatic switch of ACs capacity 1.5 to 2 Ton. Make- INDFOSS or equivalent as approved by AGE(I). |
| 15 | Supply and replacement of PCB assembly for ACs 1.5 to 2.0 ton window type ACs with remote control. |
| 16 | Supply and replacement of PCB assembly for ACs 1.5 to 2.0 ton split type ACs with remote control. |
| 17 | Supply and replacement of fan blade of ACs of cap 1.5 to 2.0 ton as per existing. |
| 18 | Supply and fix sheet metal enclosures, single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, 240 volts. |
| 19 | Disconnecting electrical connection and taken out to inspect the defect of refrigerator of capacity 165 to 310 Litres including cleaning greasing, oiling of required parts etc and re-installing the same after repair and testing the unit complete |
| 20 | Supply and replacement of compressor sealed unit for refrigerator of size 165 to 220 litre capacity with copper strainer and including , supplying and charging of gas with necessary welding/soldering for leak proof as required and commissioning, testing complete all as direc. Make- Kirloskar/Tecumseh |
| 21 | Ditto as per item No-19 as above but capacity 280/320Ltrs Make-Kirloskar/Tecumseh |
| 22 | Supply and replacement of Freezer with door frame of refrigerator of capacity 165 to 220 ltrs. |
| 23 | Supply and replacement of Freezer with door frame of refrigerator capacity 286 to 310 ltrs. |
| 24 | Supply and replacement of starting box type relay 1/6 HP for Refrigerator |
| 25 | Supply and replacement of Over load protector 1/6 HP for Refrigerator |
| 26 | Supply and charging refrigerant gas in the refrigerator including satisfactory leak test and vaccum test of capacity 165 to 220 litres including replacement of copper strainer and necessary welding work. Make-Kirloskar/Tecumseh |
| 27 | Ditto as per item No-25 as above but capacity 280/320Ltrs.Make-Kirloskar/Tecumseh |
| 28 | Ditto as per item No-25 as above but Deep freezer of capacity 280/320Ltrs Make-Kirloskar/Tecumseh/Voltas/Godrej |
| 29 | Supply and replacement of thermostat switch for refrigerator of any size Make-IND FOSS/RANUTROL/HITECH. |
| 30 | Supply and replacement of door gaskets of Refrigerator 165 to 310 ltrs |
| 31 | Supply and replacement of fan motor of freezer of refrigerator 286 to 310 ltrs |
| 32 | Disconnecting and complete opening of voltage stablizer of capacity upto 10KVA and removing the burnt out unserviceable parts and cleaning. |
| 33 | Rewinding with copper enamelled wire as per existing gauge complete all as directed of transformer assembly of voltage stabilizer of capacity upto 0.5 KVA. |
| 34 | All as per item No- 32 but 1.0 KVA. |
| 35 | All as per item No- 32 but 2.0 KVA. |
| 36 | All as per item No- 32 but 4.0 KVA. |
| 37 | All as per item No- 32 but 5.0/6.0 KVA. |
| 38 | Supply and replacement of boost/buck relay of voltage stablizer of capacity upto 0.5 KVA. |
| 39 | Supply and replacement of boost/buck relay of voltage stablizer of capacity upto 1 KVA. |
| 40 | Supply and replacement of boost/buck relay of voltage stablizer of capacity upto 2 KVA. |
| 41 | Supply and replacement of boost/buck relay of voltage stablizer of capacity upto 4/5 KVA. |
| 42 | Supply and replacement of time delay relay PCB card for 0.5 to 10KVA |
| 43 | Supply and replacement of 909V sensing transformer of capacity 500ma. |
| 44 | Supply and replacement of 909V sensing transformer of capacity 1 Amp. |
| 45 | Supply and replacement of toggle switch 2way 10Amp |
| 46 | M&L for repair, maint, cleaning, descaling and inspecting defective parts and repalcing the same of water dispensor and re-installing the same after repair and descaling of condensor and servicing, testing to the complete satisfaction of Engineer in charge. |
| 47 | Supply and fixing plug top 3 pin 15 amp, 240 volts ISI marked complete all as specified. |
| 48 | PATTAN GARRISON |
| 49 | Repair & maint of water cooler 60/120 Ltr capacity by disconnecting and taking down old unserviceable burnt compressor unit and S&F with new company manufactures sealed unit compressor complete with initial filling of gas conforming to ISI mark suitable to existing water cooler including testing, complete unit for required performance and smooth functioning for 24 Hrs complete with checking internal wiring cleaning, flushing to condensing coil, cleaning to tank etc complete all as specified and directed.Notes :-(i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/MES store yard. Make of compressor unit :- Copeland / Usha / Sidwal / Voltas / Blue star |
| 50 | Material and labour for repairing to bottom base/stand of water cooler of any make/type/capacity including welding of MS/GI sheet 16 SWG of suitable size to fill up rusted patches, grinding and applying base material for smooth surface and applying 2 coat of synthetic enamel spray paint of existing colour over one coat of primer etc complete all as specified and directed by Engineer-in-charge. |
| 51 | S&F in replacement of old unserviceable starting relay with overload protector for water cooler of any capacity, complete all as specified and directed. Make :- As per existing sample or Model No. 85002/85003 of Kirloskar / Sri Ram / Hi Tech |
| 52 | S&F in replacement of running capacitor 10/15/20 mfd for water cooler complete all as specified and directed.Make :- Havells / Asian / Texla / Bajaj / EPCOS |
| 53 | S&F in replacement of old unserviceable push cock / bib cock tap, copper alloy chromium plated of 15mm bore, matching to the existing one, complete all as specified and directed. |
| 54 | S&F in replacement of old unserviceable fan blade for water cooler fan motor of type and size matching to existing sample and size complete all as specified and directed. |
| 55 | S&F in replacement of old unserviceable fan motor of cap 1/10 HP, single phase, 230 volt suitable to existing type water cooler complete all as specified and directed.Make :- Universel / AUE / Airmaster |
| 56 | S&F in replacement of old unserviceable thermostat as per existing sample/make for water cooler of any capacity, complete all as specified and directed. Make :- Renutral / Indfos / ANNAPURNA |
| 57 | S&F in replacement of old unserviceable PVC waste water pipe with clamp, suitable to existing size for water cooler of any cap, complete all as specified and directed. |
| 58 | S&F chromium plated water tray basin for water cooler of any cap matching to the existing including taking down old one and removal from site, complete all as specified and directed. |
| 59 | M&L for preparation of old painted surfaces of water cooler including repairing the denting surface by applying putty and removing old paint cleaning and applying two coats by spray painting with approved colour,,writting the SM /Ser No / unit name and date of repair of machine complete all as specified and directed.Note :- Colour code shall be approved by Engineer-in-Charge. |
| 60 | S&F in replacement 15mm dia PTMT float ball valve complete for water cooler, complete all as specified and directed. |
| 61 | S&F in replacement of starting capacitor 100/120 mfd complete all as specified and directed.Make :- Havells / Asian / Texla / Bajaj / EPCOS |
| 62 | Replacement of old unsericeable / damage condensing coil with new condensing coil matching to existing one for water cooler of cap any type , complete all as specified and directed by Engineer-in-charge. |
| 63 | S&F in replacement of 5 Amp plug top, 3 pin complete all as specified and directed. |
| 64 | S&F in replacement of old unserviceable PVC insulated, sheathed, stranded copper conductor cable of size 0.75 Sqmm, 3 core, 1100 volt grade, incl connection and testing, complete all as specified and directed. |
| 65 | Repair and Maint of window/split AC 1.5/2Ton capacity by disconnecting and taking down old unserviceable burnt compressor unit and S&F with new company manufactures sealed unit compressor complete with initial filling of gas confirming to ISI suitable to existing AC including testing complete unit for required performance and smooth functioning for 24 Hrs, complete with checking internal wiring , cleaning , flushing to condensing coil , cleaning to tank etc complete all as specified and directed.Notes:-(i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/MES store yard. Make of compressor :- Copeland / Kirloskar / Whirlpool / Voltas / Blue star / LG |
| 66 | S&F in replacement of starting capacitor 36 or 50 + 6 mfd as required at site complete all as specified and directed.Make :- Havelles / TEXLA / AUE / ASIAN / USHA / EPCOS |
| 67 | S&F in replacement of starting relay with overload protector suitable for split/ window AC any cap complete as per existing sample complete all as specified and directed. Make Anapurna / TEXLA / AUE / ASIAN / USHA. |
| 68 | S&F in replacement of anti-bacteria air filter as per sample for split/window type AC of any capacity complete all as specified and directed. |
| 69 | S&F in replacement of blower for split/window type AC complete as per existing sample complete all as specified and directed. |
| 70 | S&F in replacement of 15 Amp plug top, 3 pin complete all as specified and directed. |
| 71 | S&F in replacement of old unserviceable PVC insulated, sheathed, stranded copper conductor cable of size 2.5 Sqmm, 3 core, 1100 volt grade, incl connection and testing, complete all as specified and directed. |
| 72 | S&F in replacement of plug top (male) 20 Amps for sheet metal(industrial) enclosure complete all as specified and directed. |
| 73 | S&F in replacement of old unserviceable swing motor for 1.5/2.00 Ton split AC/ window type AC as per sample and existing make, complete all as specified and directed. |
| 74 | S&F in replacement of old unserviceable condenser coil/ evaporator coil (cooling coil) suitable for split AC/ window AC 1.5/ 2.0 Ton including welding/ soldering at site, all as per sample complete all as specified and directed. |
| 75 | S&F in replacement of old unserviceable PCB circuit with remote,display, board, display sticker, Transformer, suitable for window / split type AC of any type and any capacity including all electrical connections at site, complete all as specified and directed. Make of OEM :- Samsung / LG / VOLTAS / Haier |
| 76 | S&F in replacement old unserviceable PVC front grill as per existing sample for window type AC 1.5/ 2.0 Ton complete all as specified and directed. |
| 77 | Dismantling/ opening the split AC/ window type AC 1.0 / 1.5 / 2.0 ton capacity from the site and supply and fixing reversible cycle valves in existing AC to function for cooling or heating system including electrical connection, refixing the AC at it's position and testing, complete all as specified and directed. |
| 78 | S&F in replacement of old unserviceable blower motor (as per sample) double shaft having for 1.5/ 2 Ton window AC, complete all as specified and directed. |
| 79 | S&F in replacement of old unserviceable indoor unit blower motor for split AC 1.5/ 2.0 Ton as per sample complete all as specified and directed. |
| 80 | S&F in replacement of old unserviceable discharge service valve as per sample for Split AC of any type complete all as specified and directed. |
| 81 | S&F in replacement old unserviceable condensing coil fan motor for Split AC 1.5/ 2 Ton as per sample complete all as specified and directed. |
| 82 | S&F in replacement of unserviceable copper pipe ½\\" dia as per sample complete all as specified and directed. |
| 83 | S&F in replacement of unserviceable copper pipe ¼\\" dia as per sample complete all as specified and directed. |
| 84 | S & F in replacement of new nitrile rubber insulation tube for split air conditioner copper pipes of any size upto 1/2\\" dia complete all as specified and directed. (Make : Glaxy/Superlon/KAIFLEX/PARAMOUNT/ARMAFLEX/ VIDOFLEX) |
| 85 | M&L for fixing M-Seal water proof in ACs window/split type, complete all as specified and directed. |
| 86 | M&L for replacement of liquid line valve of suitable size for Split AC, complete all as specified and directed. |
| 87 | Supply in replacement of remote control suitable to existing window/split type ACs (As per sample & existing make) complete all as specified and directed. |
| 88 | M&L for servicing at site of window/ split AC of any type, any size by opening , cleaning, re-fixing the filters, cleaning & washing of condenser and evaporator coil with brushes, chemical etc. including taking down and refixing in position of AC, if reqd for satisfactory functioning of AC complete all as specified and directed.Note : Gas and spare parts are measure for separately. |
| 89 | Repair and maint of deep freezer of 120 to 500 ltr capacity by disconnecting and taking down old unsv burn compressor unit and Supply and fixing new company manufactures sealed unit compressor complete with initialfilling of Gas confirming to ISI suitable to existing deep freezer including testing ,complete unit for required perfermance and smooth functioning for 24 Hrs complete with checking internal wiring , cleaning , flushing to condensing coil, cleaning to tank etc. complete all as specified and directed .Notes :- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All Engineering works shall be carried out at site/ MES store yard and in presence of Engineer-in-Charge. (Make of compressor : Copeland / Voltas / LG / Usha / Godrej |
| 90 | S&F in replacement of old unserviceable starting relay as per sample for deep freezers of any capacity, complete all as specified and directed. |
| 91 | S&F in replacement of old unserviceable thermostat switch as per sample for deep freezer of any capacity, complete all as specified and directed.Make :- Renutrol / Indofoss / ANNAPURNA |
| 92 | S&F in replacement of old unserviceable blower motor as per sample for deep freezer complete all as specified and directed. |
| 93 | Supply and fixing in replacement of Door Lock with door gasket for refrigerator 165 to 310 ltrs complete all as specified and directed. |
| 94 | M & L for replacement of deep freezer outer body 320 ltr capacity including all accessories as per existing make approved by Engr-in- charge. |
| 95 | Repair and maint of refrigirator 210 to 320 Ltrs capacity by disconnecting and taking down old unsv burnt compressor unit and S&F with new company manufactures sealed unit compressor complete with initial filling of gas confirming to ISI suitable to existing refrigirator including testing complete unit for required performance and smooth functioning for 24 Hrs complete with checking internal wiring , cleaning , flushing to considering coil , cleaning to tank etc complete all as specified and directed.Notes:- (i) Purchase Voucher, test certificate, warranty to be furnished by the contractor to Engineer-in-Charge. (ii) All engineering works shall be carried out at site/ MES store yard and in presence of Engineer-in-Charge.Make of compressor :- Whirlpool / LG / Samsung / Copeland / Godrej |
| 96 | S&F in replacement of old unserviceable cooling coil freezer/ evaporator assy as per sample for refrigerator of any capacity complete all as specified and directed. |
| 97 | S&F in replacement of old unsv condensing coil assembly as per sample for refrigerator of any capacity, any type (single door/ double door) complete all as specified and directed. |
| 98 | S&F in replacement of old unserviceable auto defrost thermostat switch as per sample for refrigerator of any capacity. Make: ANNAPURNA or equivalent approved make. |
| 99 | S&F in replacement of old unserviceable starting PTC relay with OLP as per existing sample for Refrigerator of any cap Make:- Godrej / Whirpool / Hi-Tech / LG complete all as specified and directed. |
| 100 | S&F in replacement of old unserviceable cooling coils (fins and tube type/ pressed type) for double door refrigerator (as per sample required at site) complete all as specified and directed. |
| 101 | S&F in replacement of old unserviceable timer as per sample for double door refrigerator of any capacity complete all as specified and directed. |
| 102 | S&F in replacement of old unserviceable Bimetal thermostat assembly as per sample for double door refrigerator of any capacity complete all as specified and directed. |
| 103 | S&F in replacement of old unserviceable blower motor/fan motor as per sample for double door refrigerator of any capacity complete all as specified and directed. |
| 104 | S&F in replacement of old unserviceable heater as per sample for any capacity refrigerator complete all as specified and directed. |
| 105 | S&F in replacement of old unserviceable transparent vegetable tray as per sample for any capacity refrigerator complete all as specified and directed. |
| 106 | S&F in replacement of old unserviceable wire shelf set as per sample for any capacity refrigerator complete all as specified and directed. |
| 107 | S&F in replacement of old unserviceable electronic control board (PCB) as per sample for refrigerator of capacity 210 Ltrs to 320 Ltrs including connection, complete as specified and as directed. |
| 108 | M&L for charging refrigerant gas R-22 in old or new compressor and make up required pressure including brazing and testing, complete all as specified and directed. |
| 109 | Supply and fixing in replacement of Interior light fittings with bulb for refrigerator of any size and any capcity |
| 110 | M&L for charging refrigerant gas R-134a or 410a in old or new compressor to make-up required pressure including cutting piping, brazing and testing, complete all as specified and directed. |
| 111 | M&L for writing SM Number / MES No , Unit and date of repair on refrigerator / deep freezer and AC with paint & colour, text height complete all as specified and directed by Engr-in-Charge.Note: The writing of SM/MES No at one equipment shall be measured as one unit. |
| 112 | M&L for repair of voltage stabilizer of 15 KVA of any type including replacement of spare parts such as transformer, PCB, diode, condenser, preset ic , volt meter, ammeter, indicator lamp, socket outlet and any other parts as required for proper functioning of stabilizer complete along with testing and transportation charges from site to workshop, complete all as specified and directed. |
| 113 | Supply of CTC (commercial technical chemical) for flushing of refrigerator & deep freezer lines to remove choking all as specified and directed. |
| 114 | S&F copper coil capillary tube for Refrigerator/ Deep freezer as per sample size complete all as speciifed and directed. |
| 115 | S&F in replacement of old Unsv copper Pencil filter drier with new drier filter having desiccant complete including necessary cutting, removing old drier filter with reqd brading work for Refrigerator, Deep Freezer any cap complete all as specified and directed. |
| 116 | M & L for replacement of Gas charging pin valve for any type of AC as per sample all as specified and directed. |
| 117 | Note :- An amount of Rs. Rs 59,001.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 days