Rural Development Government Departments Closing in 3 days TDR #56217680

Tender For Mp-Lads-2025-26-Sri. Rajmohan Unnithan,Honble Mp (Ls)- Electrificationof Modern Crematorium Building At Thuruthi Kadamkod (Sc Category) Incheruvathur Grama Panchayath-Electrification-General Electrical Work

Issued by Government Departments · Kasaragod, Kerala
Tender Value
84717
Estimated cost
Bid Submission
08 Jul 2026
3 days left
EMD
2118
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kasaragod → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Mp-Lads-2025-26-Sri. Rajmohan Unnithan,Honble Mp (Ls)- Electrificationof Modern Crematorium Building At Thuruthi Kadamkod (Sc Category) Incheruvathur Grama Panchayath-Electrification-General Electrical Work

BOQ

Name of Work:- MP-LADS-2025-26-Sri. Rajmohan Unnithan,Honble MP (LS)- Electrificationof modern crematorium building at Thuruthi Kadamkod (SC category) inCheruvathur Grama Panchayath-Electrification-General Electrical Work
Sl. No. Item Description
1Electrification
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
3OD94993/2025-2026:Wiring combined plug point together with the light point/ fan point/ exhaust fan point/ call bell point including 6 A 5 pin modular socket controlled by 6A one way modular switch in the existing switch board and giving connection to the phase,neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable ( Green wire for earthing) etc as required.
41.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
590.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
690.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
7OD19795/2026-2027:Supply, conveyance, installation, testing and commissioning of cast aluminium stove enameled elliptical shaped bulk head fittings directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required
8OD19809/2026-2027:Supply and providing the 9W LED Bulb in the existing fittings as required
990.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1090.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
111.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
121.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
131.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
141.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
151.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
161.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
172.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
182.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
192.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
202.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
215.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2290.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2390.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
2490.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
2590.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
26OD94968/2025-2026:Supply and providing 25x3mm brass nut and bolt etc. as required
27OD94983/2025-2026:Supply and providing 12x3mm brass nut and bolt etc. as required
28OD94987/2025-2026:Supplying and fixing 32A HRC Fuse with HRC Fuse link with connections, in existing meter board
29OD94985/2025-2026:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
30OD94977/2025-2026:Supply & installation of dust and vermin proof, single Phase Syntax Meter Board( GS-MB- 4030) and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required.
31OD94990/2025-2026:Supply and installation of switch gear units in sheet steel enclosure complete withhandle assembly, door interlock and pad locking arrangement of the following ratingson existing angle iron frame work or directly to wall using necessary bolts & nuts,fixing the unit to wall, making good the damages, colour washing etc. including givingnecessary connections as required.32 Amp SPN SDF AC 23A with ISI marked HRCfuse
32OD94972/2025-2026: Supply and providing M8 anchor bolt hook in wall / parapet for binding support for service main Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56217680
AUTHORITY Government Departments
TENDER VALUE 84717
LAST DATE 08-07-2026
Authority
Authority Name Rural Development Department
Work Description Tender for Mp-Lads-2025-26-Sri. Rajmohan Unnithan,Honble Mp (Ls)- Electrificationof Modern Crematorium Building At Thuruthi Kadamkod (Sc Category) Incheruvathur Grama Panchayath-Electrification-General Electrical Work
Basic Detail
Tender No 4307553/2026
Bidding Type Tender
Location
City Kasaragod
State Kerala
Key Dates
Publish Date 30 Jun 2026
Submission Date 08 Jul 2026
Open Date 10 Jul 2026
Finance
Tender Value 84717
Tender Fee 555
EMD 2118
Exemption Available
Document List
01618e47-da78-43e1-9a4d-fc41063a68e5.html
BOQ_1449981.xls
ELECTRIAFFIDAVIT.pdf
ELECTRIAGREE.pdf
ELECTRIBID.pdf
ELECTRIEPAYMENT.pdf
ELECTRIFORMOFTENDER.pdf
ELECTRINIT.pdf
ELECTRIPACT.pdf
ELECTRISBD.pdf
Tendernotice_1.pdf
Tendernotice_2 (6).pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

01618e47-da78-43e1-9a4d-fc41063a68e5.html

xls

BOQ_1449981.xls

pdf

ELECTRIAFFIDAVIT.pdf

pdf

ELECTRIAGREE.pdf

pdf

ELECTRIBID.pdf

pdf

ELECTRIEPAYMENT.pdf

pdf

ELECTRIFORMOFTENDER.pdf

pdf

ELECTRINIT.pdf

pdf

ELECTRIPACT.pdf

pdf

ELECTRISBD.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (6).pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders