Tender For Ht Constructing 11Kv S.C Line From Manjappallikunnu To Azhanthakuzhi In Ht/Lt Configuration (Cw-5633-202526-9)
Tender Value
9.41 Lakhs
Estimated cost
Bid Submission
08 Jul 2026
6 days left
EMD
23600
Bank guarantee accepted
Document Fee
2242
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Ht Constructing 11Kv S.C Line From Manjappallikunnu To Azhanthakuzhi In Ht/Lt Configuration (Cw-5633-202526-9)
BOQ
| Sl. No. | Item Description |
| 1 | Stringing of one km 3 PH 11kV line with XLPE Insulated ACSR Raccoon or equivalant (3 conductors) |
| 2 | Insertion of one LT PSC pole in existing single phase OH line including digging & back filling pit in ordinary soil, fitting cross arm, insulator, binding etc. excluding transportation of poles. |
| 3 | Providing Stay for LT poles including digging & back filling pit in ordinary soil. |
| 4 | Renewal of existing damaged/broken old LT stay in existing stay rod. |
| 5 | Providing Strut using LT PSC pole including digging and back filling pit in ordinary soil. |
| 6 | Straightening one slanted LT pole after unbinding the line and binding the line after work. |
| 7 | Straightening one slanted LT Cut Pole after lowering down the existing line and stringing the line after work. |
| 8 | Erection of Anchor clamp / dead end clamp for LT ABC of any size |
| 9 | Reconductoring (changing) one km LT single phase 2 wire OH Copper/old AAC/ACSR conductor line with new ACSR Rabbit conductor including conveyance of materials to and from the stacking place. |
| 10 | Providing End Caps |
| 11 | Installation of Insulation piercing connector for main to service line main:16-95 sqmm, Tap 16-95 sqmm |
| 12 | Installing One No. Insulation piercing connector of size Main :16 to 95 ,Tap:1.5 to 16 Sq.mm |
| 13 | Singe Phase Satellite connectors upto 4 service main connections (25-95 ABC/2.5-25 sqmm SM wire-2No) |
| 14 | Labour charges for loading LT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle). |
| 15 | Additional rate for excavation of one Pit for LT Pole/LT Stay in Hard Laterite. |
| 16 | Transporting LT ABC by hired vehicle to a distance up to 5 km and carring up to 2 drum including loading and un loading using crane |
| 17 | Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling. |
| 18 | Cutting Channel/Cross Arm/Angle Iron into two pieces. |
| 19 | Drilling hole of various sizes on existing Channel/Cross Arm. |
| 20 | Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt & nut etc. |
| 21 | Reconductoring (changing) one km LT OH Copper/old AAC/ACSR one conductor with new ACSR Rabbit conductor including conveyance of materials to and from the stacking place. |
| 22 | Insertion of one LT PSC pole in existing three phase OH line including digging & back filling pit in ordinary soil, fitting cross arm, insulator, binding etc. excluding transportation of poles. |
| 23 | Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole including digging and back filling pits in ordinary soil, drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing). |
| 24 | Labour charges for loading HT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle). |
| 25 | Additional rate for excavation of one Pit for HT Pole/HT Stay in Hard Laterite. |
| 26 | Stringing of one km 3 PH 11kV line with XLPE Insulated ACSR Raccoon or equivalant (3 conductors) after fitting insulators, binding conductors to pin insulators using suitable tie and anchoring with wedge type anchoring clamps including cutting and removing tree branches wherever necessary excluding cut point works. |
| 27 | Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm and connecting to existing MVT or other terminals,using the cable end termination kit supplied departmentally including charges for cable jointer etc. complete as per the direction of the departmental officers. |
| 28 | Providing bridging at Cut points for 3 PH 11kV line with XLPE Insulated ACSR Raccoon or equivalent (1 conductors) using IPC and respective conductors |
| 29 | Erection of Anchor clamp / dead end clamp for 11kV ABC of any size |
| 30 | Conveyance of one km 11kV line materials from section store/stacking place to the work site (excluding poles). |
| 31 | Fitting and providing one Strut using HT PSC pole including digging and back filling pit in ordinary soil. |
| 32 | Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP including conveyance of materials. |
| 33 | Additional rate for providing one disc set, PG clamp etc. complete, on any type of HT pole for making cut point. |
| 34 | Fitting one Additional V cross arm in existing single pole including conveyance of materials. |
| 35 | Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole including conveyance of materials. |
| 36 | Fitting and erecting one HT Double Pole Structure using A type pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing). |
| 37 | Providing concrete muffing of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides. |
| 38 | Additional rate for excavation of Pit for A type pole in Hard Laterite. |
| 39 | Dismantling (without damage) one 11kV PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same. |
| 40 | Transferring LT three phase 4/5 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete. |
| 41 | Labour charges for loading HT A type pole from the stacking place and unloading the same at work site (transportation by any vehicle). |
| 42 | Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 numbers of poles excluding loading& unloading charges. |
| 43 | Providing one Driven Earth using GI earth pipe of size 38.1mm dia, 2.5m length at minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in loose soil. |
| 44 | Fitting and erecting one HT PSC Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing). |
| 45 | Insertion of one HT PSC pole in existing HT/LT line including digging & back filling of pit in ordinary soil, fitting cross arm, insulator, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing). |
| 46 | Dismantling (without damage) LT stay including digging pit in all classes of soil and backfilling. |
| 47 | Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same. |
| 48 | Dismantling (without damage) one km 11kV line (three conductors) including dismantling cross arm, insulators, disc, disconnecting jumper connection, rolling the conductor and stacking the materials. |
| 49 | Fitting and erecting one HT A type Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing). |
| 50 | Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing. |
| 51 | Fitting and providing one HT Stay for 11kV pole, including digging and back filling pit in ordinary soil. |
| 52 | Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting 2 channel cross arms, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing). |
| 53 | Additional rate for refitting/redoing one Disc set while renewing any type of 11kV cut pole. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 days