Tender For Supply Of Coverd Conductor-11Kv 99 Sq.Mm Aaac With Accessories And Reconductoring 5.5Km Double Circuit 11Kv Feeders - Marthimoodu And Enadimangalam From,110Kv Substation,Pathanapuram To Puthuval Border Ab,With Coverd Conductor,As Per The R
Tender Value
79.42 Lakhs
Estimated cost
Bid Submission
16 Jul 2026
14 days left
EMD
50000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kollam → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Of Coverd Conductor-11Kv 99 Sq.Mm Aaac With Accessories And Reconductoring 5.5Km Double Circuit 11Kv Feeders - Marthimoodu And Enadimangalam From,110Kv Substation,Pathanapuram To Puthuval Border Ab,With Coverd Conductor,As Per The Request Of M/S Kinfra Park ,Adoor On Turnkey Basis At Electrical Section Pathanapuram
BOQ
| Sl. No. | Item Description |
| 1 | MaterialDisc insulator 11 kV composite polymeric covered conductor |
| 2 | Single core outdoor termination kit forcovered conductor |
| 3 | Aluminium Clamp Fiber fixed with CBN ForClamping 120 Sq.mm Covered Conductor |
| 4 | Mid Span Joint for 70 Sq.mm -HT CoveredConductor (Compression Type) |
| 5 | Insulation Piercing connector Bare to coveredconductor |
| 6 | Covered Conductor -11kV 99 Sq.mm AAAC |
| 7 | Anchoring /Dead end Clamp Assemblysuitable for XLPE insulated covered condutorequivalent to ACSR Rabbit 50 Sqmm |
| 8 | Pin Insulator 11 kV composite polymeric heavy headed type for covered conductor |
| 9 | Tension/Anchoring clamp assembly withtracking protection IPC for coveredconductor |
| 10 | Non-metalic alignment tie (Pin insulator) forcovered conductor |
| 11 | Insulation Piercing Connector for CoveredConductor -Main 35-240 Sq.mm,Tap 35-240Sq.mm( For AAAC Covered Conductor) |
| 12 | LabourLabour charges for loading HT Four legged latticestructure from the stacking place and unloading the sameat work site (transportation by any vehicle). |
| 13 | Labour charges for loading HT A type pole from thestacking place and unloading the same at work site(transportation by any vehicle). |
| 14 | Transporting poles by hired vehicle to a distance upto5km and carrying upto 4 numbers of poles excludingloading& unloading charges. |
| 15 | Fitting and erecting one HT Four legged lattice structurein position including fitting cross arm, digging and backfilling pit in ordinary soil (as per standards), drawingsufficient length of GI earthing leads from F clampthrough V cross arm to the ground for earthing (excludingprovision of earthing). |
| 16 | Fitting and erecting one HT Double Pole Structure usingA type pole in position including fitting 2 No. channelcross arm, digging and back filling pit in ordinary soil,drawing sufficient length of GI earthing leads through allcross arms to the ground for earthing (excluding provisionof earthing). |
| 17 | Fitting and erecting one HT A type Single Pole in position, including fitting cross arm, digging and backfilling pit in ordinary soil (as per standards), drawingsufficient length of GI earthing leads from F clampthrough V cross arm to the ground for earthing (excludingprovision of earthing). |
| 18 | Additional rate for excavation of Pit for A type pole inLaterite. |
| 19 | Providing one Earth using GI earth pipe of size 38.1mmdia, 2.5m length including digging separate pit(0.45x0.45x2.5m) at a minimum distance of 1.5m awayfrom the pole/structure and maintaining standard distancebetween different earth pipes in ordinary soil &backfilling. |
| 20 | Additional rate for excavation of one Earth Pit (2.5mdepth) in Laterite. |
| 21 | Providing one Coil Earth using No.8 GI-earth wire(50mm dia, 115 turns) including digging separate pit(0.45x0.45x1.5m) at standard distance away from thepole/structure in ordinary soil & backfilling. |
| 22 | Fitting one set (3No.) 11kV LA and giving connectionsexcluding earthing. |
| 23 | Fitting one set AB switch on existing DP, givingconnection and drawing sufficient length of GI earthingleads to the ground for earthing, excluding provision ofearthing. |
| 24 | Conveyance of one km 11kV line materials from sectionstore/stacking place to the work site (excluding poles). |
| 25 | Fitting one Additional V cross arm in existing single poleincluding conveyance of materials. |
| 26 | Fitting one Additional 75x40mm, 1.8m Channel cross armin existing single pole including conveyance of materials. |
| 27 | Fitting one Additional 2.4/3m Channel cross arm(75x40x6mm), in existing 11kV DP including conveyanceof materials. |
| 28 | Additional rate for excavation of Pit for 4 legged pole in Laterite. |
| 29 | Replacing one set AB switch including dismantlingexisting AB, giving connections etc. |
| 30 | Dismantling (without damage) one 11kV A type pole afterdisconnecting stays, strut etc. attached thereon andstacking the same |
| 31 | Dismantling (without damage) one Channel cross armfrom existing DP structure and bringing back to sectionstore. |
| 32 | Providing concrete muffing of size 0.45x0. 45x1.5m(0.5m above GL and 1m below GL). Excavation0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m,Plastering (1:3) 12mm 0.45x0.45mx5sides. |
| 33 | Additional rate for providing one HT Pin with insulator,complete on any type of HT pole. |
| 34 | Providing concrete muffing for fabricated 4-legged poleProviding concrete muffing of size 0.50x0. 50x2m (0.5mabove GL and 1.5m below GL). (cost index(e) : 1included in Rate) |
| 35 | Painting A pole structure with one coat Synchromateprimer and two coat grey enamel paint/aluminium paintincluding cost of paint. |
| 36 | Stringing of one km 3 PH 11kV line with XLPE InsulatedACSR Raccoon or equivalant (3 conductors) after fittinginsulators, binding conductors to pin insulators usingsuitable tie and anchoring with wedge type anchoringclamps including cutting and removing tree brancheswherever necessary excluding cut point works. |
| 37 | Drilling hole of various sizes on existing Channel/CrossArm. |
| 38 | Drilling oval shaped hole of various sizes on existingChannel/Cross Arm/GI/MS cleat etc. |
| 39 | Dismantling (without damage) one km 11kV line (threeconductors) including dismantling cross arm, insulators,disc, disconnecting jumper connection, rolling the conductor and stacking the materials. |
| 40 | Fitting and providing one HT Stay for 11kV pole,including digging and back filling pit in ordinary soil. |
| 41 | Additional rate for excavation of one Pit for HT Pole/HTStay in Laterite. |
| 42 | Renewal of existing damaged/broken old 11kV Stay to theexisting stay rod. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 days