Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #56216527

Tender For Comprehensive Maintenance Work To Md Accn For Jcos / Or At Dronachal Top Under Ge Dronachal

Issued by Statutory Bodies & Commissions/Committees · Bhopal, Madhya Pradesh
Tender Value
35 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
8 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Comprehensive Maintenance Work To Md Accn For Jcos / Or At Dronachal Top Under Ge Dronachal

BOQ

Name of Work:- COMPREHENSIVE MAINTENANCE WORK TO MD ACCN FOR JCOs / OR AT DRONACHAL TOP UNDER GE DRONACHAL
Sl. No. Item Description
1M&L for preparation of old decorated plastered or unplastered surfaces and applying one coat of white wash on ceiling complete all as specified and directed.
2M&L for complete removal of existing treatment on walls and applying 1 coat of wall care white putty 1-2mm thick and applying 2 coats of oil bound distemper including a coat of compatible wall priming paint complete all as specified and as directed.
3M & L for preparing of old distempered surface of wall and applying one coat of oil bound distemper complete all as specified and directed.
4M & L for preparing of old /any surfaces of wall and applying two coat of cement based paint complete all as specified and directed.
5M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
6M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
7Hacking out old broken glass of ( any thickness, size or quality from wooden or metal frame glazed with putty or beads/cleat etc complete all as specified and directed.
8S&F 3-4mm thick figured glass with oil putty, ordinary quality not exc 0.5sqm in each pane complete all as specified and directed.
9S&F 3-4mm thick plain sheet glass fixed with oil putty, ordinary quality n exc. 0.5sqm in each pane complcomplete all as specified and directed.
10Easing of door shutters, window shutters, wooden cupboard shutters, show case shutter drawers incl fixing of screws for easy closing/opening and tightening of hinges or changing the position of hinges, adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed.
11Petty repairs to leaking water in bib taps, pillar taps, stop cock, angle valve, shower, concealed stop cock, low level flushing cistern , CPVC/GI pipe fittings incl replacing & providing of good quality rubber washer check nuts plunges ,taflon tape, M-seal, brass spindles (specific type), GI/ brass/CPVC fittings etc or any other minor accessories / repairs to make the system all time functional , ensure smooth water supply without any wastage and stop water leakage complete all as specified and directed.
12Cleaning and removing all scale and dirt etc from tanks Capacity exc 250 but not exc 500 litres & from mouths of circulating pipes etc of service water/loft tanks in / over roof buildings at different locations of capacities as under: Note:1. The contractor will write date of cleaning & next due date of cleaning on Tank as directed by the Engr-in-Charge.2. At the time of cleaning disconnected pipes/fittings shall be reconnected as per existing to make it leak proof complete all as specified and directed.
13Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar complete all as specified and directed .
14M&L Granite/ green Marble (approved pattern) work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) 20mm including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble complete all as specified and directed.
15M&L for vitrified ceramic tiles of light shade 8 to 10 mm thick (square/rectangular) of size 600 mm x 600 mm as in floors/skirtings etc. over and including 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match with shade of tiles, incl dismantling floor hearth or wall tiling including cement mortar bedding, removing serviceable tiles to store and rubish of the premisses complete all as specified and directed.
16M&L for non skid cramic tiles colured of size area of each tile exc 0.16 sqm but not exc 0.38 sqm in flooor and in skirting etc, jointed in neat cement slurry and pointed in white or colours cement to match complete all as specfied and directed over and including 15 mm thick screed bed in Cement Mortar 1:6 incl dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) , removing serviceable tiles to store and rubish of the premisses complete all as specified and directed
17M&L for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, including finishing of concrete topping even and rough complete all as specified and directed
18M&L for coloured Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular), coloured tiles, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed in CM 1:6 incl dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) , removing serviceable tiles to store and rubish of the premisses completeall as specified and directed.
19M&L for coloured Glazed ceramic tiles in vertical surface 450 X 300 X 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to matchtiles in vertical surface including 10mm thick rendering in CM 1:4, incl dismantling of tiling including cement mortar bedding (but not backing) , removing serviceable tiles to store and rubish of the premisses complete all as specified and directed
20Demolition of cement concrete in ground floors and pavings not exc. 15 Cm thickness (below/above ground level) including floor finishes all as specified and directed
21M & L cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete to be laid in required slope complete all as specified and directed.
22Taking up or down pvc/ steel tubing of 20/25mm bore and connections complete all as specified and directed
23S&F CPVC pipe 20mm dia of grade SDR-11 (class-I) including all CPVC and brass fittings fixed to wall, floor or ceiling or laid in floors etc complete all as specified and directed.
24S&F CPVC pipe 15mm dia of grade SDR-11 (class-I) including all CPVC and brass fittings fixed to wall, floor or ceiling or laid in floors with and incl clamps etc complete all as specified and directed.
25Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface complete all as specified and directed
26S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron or cpvc pipe and fixed complete all as specified and directed
27S&F in repair 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
28Dismantling of old broken water storage tank cap exc 250 ltrs and n exc 500 ltrs complete all as specified and directed
29S&F rotational moulded polyethylene water storage tank 500 ltrs cap cylindrical vertical with closed top hoisted and fixed in position at roof or stand all as specified in SSR Pt-I complete all as specified and directed
30S&F in repair PVC water tank cover (black/white) suitable for size 250 ltr to 500 ltr capacity etc complete all as specified and directed.
31S&F in repairs 20/25mm Ball (float) valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron/pvc/cpvc pipe in water tank and fixed. (Minimum weight 25mm-455gms) complete all as specified and directed
32S&F in repair Vitreous china wash hand basin (550X400mm) white, flat back excluding taps but including brackets & CP waste coupling 32mm, LDPE waste pipe 32mm upto floor trap complete all as specifed and directed.
33S&F in repair vitreous china wash down water closet pan (pedestal pattern), white and trap including seat cover, fixing bolt, flush pipe, connection to drain (or out going pipe) and to flushing pipe, antisyphonage pipe, etc (complete set) all as specified & as directed.
34S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern', size 580 mm x 440 mm, white with integral foot rests, embedded and set in PCC 1:5:10 type E-2 incl flush pipe and making good to floor including removing rubbish all as specified and directed.
35S&F in repairs 32mm bore LDPE waste pipe for WHB/ sink length not less than 80cm upto floor trap complete all as specified and directed.
36S & F in repair 10 ltrs capacity PVC low level flushing cistern, of make specified with inlet, float valve and handle including bracket with 32 mm dia PVC flush pipe complete all as specified and as directed.
37S & F in repairs kit for PVC flushing cistern valveless, syphonic action kit and washers type, 10 litres capacity with inlet, ball valve float and handle any make with exisiting fixed, complete all as specified and directed.
38S&F in repair fancy type 15 mm bore Pillar cock tall height, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
39S&F in repair 15mm bore fancy type CP bib tap long body, cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule complete all as specified & as directed.
40S&F in repair CP two way bib tap 15mm dia complete all as specified and directed.
41S&F in repair 15/20mm bore dia CP stop valve/angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed
42S&F in repair 15 mm bore CP Concealed Stop valves with long shank and cup fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe complete all as specified and directed
43S&F in repairs brass chromium plated shower rose with swivel joint not less than 125mm dia and not less than 200mm long arm all as specified and directed.
44S&F in repairs CP SS Soap dish premium quality, fixed to wall with plugs and screws complete all as specified and directed.
45S&F in repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed.
46S&F in repairs PVC connection 15mm dia of length not less than 600mm with both ends, brass fly nut for water supply complete all as specified & as directed.
47S&F in repair CP Health faucet( ABS Body) suitable for 15mm dia pipe with 1.25m long flexible steel tube and ABS wall hook incl making connections and fixed in position complete in all respect as specified
48Supply and fixing in repair brass chromium plated kitchen sink waste coupling comperising of four parts CP brass kitchen sink strainer & basket, rubber gasket, PTMT locknut, PTMT strainer sleeve with 32mm outlet and check of any dia as per site requirement complete all as specified and directed.
49S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including beding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mmx 460mm bowl size 410mm x 330mmx 160mm complete all as specified and directed
50S&F in repair 600mmx450mm Looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed
51Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but n exc 4.0 sqm each complete all as specified and directed.
52Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.5 sqm each complete all as specified and directed.
53Taking down Shutters of any description exc 1 sq m but n exc 2 sqm each complete all as specified and directed
54M&L for Pressed steel frames for doors of size 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed
55M&L for cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for fixing hold fast, coping, cills and filling in pressed steel door frames including plastering, painting and finishing the surfaces to match with existing surface complete all as specified and directed.
56S&F 35mm thick second class hard wood factory made, plain framed panelled door shutter (any number of panels) with panel of 9mm thick BWP commercial plywood or 12mm thick veneered particle board medium dencity, wood partical board with commercial face veneers. The size of members of shutters shall be as specified in section 8 clause 8.20 (a) of SSR Part-I 1991 complete all as specified and directed
57S&F 35mm thick second class hard wood factory made glazed and Skelton door shutter open rebated and prepared to receive glass or gauge etc divided into square with plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note: - Size of member of shutters as specified in SSR Part-I 1991 section 8 clause 8.24 (a) complete all as specified and directed
58S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed
59S&F solid PVC door frame(approved color) of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing complete all as specified and directed.
60S&F Factory made solid panel PVC door shutter(approved color and pattern) 30mm thick (stiles) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap inserted for top rail and bottom rail. Penelling of plain colour PVC sheet to be fitted to the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame at site complete all as specified and directed.
61Supply only galvanised mild steel wire clothes 0.46 mm nominal dia of wire and average width of aperture 1.4 mm complete all as specified and as directed . Note : Fixing only rate is included in window/door shutter item considered therein.
62S & F 100mm size Butt hinges, medium weight cold rolled, stainless steel and fixed complete all as specified and as directed.
63S&F Aluminum tower bolts of extruded section of size 150mm all as specified and directed.
64S&F 150 mm size Extruded aluminium alloy handles, fabricated type., anodised handles all as specified and directed.
65S&F 250-300mm size Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
66S&F double body Floor door stopper of aluminium alloy body and tongue, anodised fixed in door shutters complete all as specified and directed.
67M & L preparing wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
68M&L for preparation of new steel surfaces over 10cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
69S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of tinned tacks, or galvanised wire staples complete all as specified and as directed .
70S&F in repairs 100mm size Butt hinges, medium weight cold rolled, stainless steel and fixed complete all as specified and as directed.
71S&F in repairs Aluminum tower bolts of extruded section of size 150mm all as specified and directed.
72S&F in repair 150 mm size Extruded aluminium alloy handles, fabricated type., anodised handles all as specified and directed.
73S&F in repairs 250-300mm size Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
74S&F in repairs double body Floor door stopper of aluminium alloy body and tongue, anodised fixed in door shutters.
75S&F 17-18mm thick WPC (Wood plastic Composite) water proof board, interior grade, but prelaminated both sides with decorative choice laminations, fixed to frame work incl dismantling boarding, any description, fixed in any position with screws etc complete all as specified and directed and approved by Engr-in-Charge.
76S&F 2nd class hard wood plain fillet sq. rect and triangluar in section, wrought secured with sectional area exc 13 but n exc 25 sqcm complete all as specified and directed
77S&F 75mm size Hasp and staple, aluminium anodised, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed
78S & F 30mm Continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed
79S&F magnetic catches for cabinets of size 50 mm complete with striking plate & magnetic stud complete all as per approved smaple complete all as specified and directed.
80S&F in repair SS kitchen plate rack made out of 1mm thick sheet of type SS 304 grade of size min 750x600mm of best quality of approved make complete all as specified and directed.
81S&F 75mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint laid in trenches or in floor or fixed to walls etc incl bends, elbow, tee, coupler etc equal or unequal complete fittings incl taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store all as spd and directed.
82S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint laid in trenches or floors or fixed to walls etc incl bends, elbow, tee, coupler etc equal or unequal complete fittings incl taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store all as spd and directed.
83S&F in repair PVC (SWR) floor trap plain with grating having dia meter of out let 75mm including jointing with solvent cement complete all as specified & as directed.
84Material and labour for sunken floor treatment as follows:-
85(i) Demolition of cement concrete in sunken floors incl. removing dubrish outside MD land complete all as specified and directed.
86(ii) Brushing neat cement slurry with 3.0kg of cement per sq. metre mixed with WPC @ 3% by weight of cement as per manufacturer's instruction to fill all hole and crack complete all as specified and as directed. Note:- Water tightness testing should be done after 24 hours
87(iii) Material and labour for PCC (1:1 1/2 :3) type A-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Note : Water proofing compound will be measured and paid separately.
88(iv) Material and labour for plastering on vertical sides and top surface of CM (1:3) 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time. Note :Water proofing compound will be measured and paid separately.
89(v) Material and labour for 2 coats of Dr. Fixit krystalline waterproofing coating compound shall be applied after laying sewage/ plumbing pipes with fixtures in position.
90(vi) Material and labour for filling the sunken floor with PCC ( 1:5:10) type E-2 using brick aggregate over the treated surface.
91(vii) Material and labour spouts of 50mm dia GI pipe light grade projecting 450mm clear of face outer wall with PVC mosquito proof cap on inner face of pipe shall be provided to drain out seepage water , if any.Note : Water tightness testing should be done after applying Dr Fixit epoxy compound, by pounding water for 72 hours & rectify defects if any till total elimination of defect. Dubrish to be removed outside MD land.
92Taking down cement plaster from brick or concrete surface incl raking out joints hacking for key and scrubbing down with water complete all as specified and directed.
93Rendering 15 mm thick on fair face of brick work or concrete surfaces or stone masonry surfaces or surface in CM 1:4 using WPC finished even and smooth without using extra cement complete all as specified. Note: WPC shall be measured and paid separately under relevant item.
94M&L for rendering 10 mm thick on brick or concrete surfaces or surface other than fair faces of brick work in cement plaster 1:6, finished even and smooth w/o using extra cement all as specified and directed
95M&L for preparation of newly plastered or unplastered surfaces in walls soffits, facia, chajjas and applying two coat of exterior weather proof water based emulsion over a coat of compatible primer complete all as specified and directed.
96M&L for preparing of newly plastered surface of walls and applying one layer of white putty 1-2 mm and two coats of oil bound distemper over a coat of compatible primer etc complete all as specified and directed.
97Supply only integral water proofing compound of approved make complete all as specified and as directed
98Demolition of cement Concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
99M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges using WPC of approved make as per manufacturers instruction all as spc and directed (WPC shall be measured and paid separately)
100M&L for 10mm thick cement plaster over PCC in CM 1:3 finished even and smooth (without using extra cement) and using WPC of approved make per manufacturers instruction all as spcified and directed (WPC shall be measured and paid separately)
101M&L for preparation and cleaning of newly plastered surface and applying two coat of Dr fixit Roofseal classic as per following direction 1. Marking of 2 x 2 m area on roof/terrace surface 2. Apply Ist coat on ready surface in one direction using 1.5 ltr/ 4 sqm area 3. Apply 2nd coat using 1.0 ltr/ 4 sqm after 12 hrs in perpendicular direction of 1st coat application 4. Removal of all unwanted material and debris outside MD land.
102M & L PCC (1:3:6) type C-2 using 40mm graded stone aggregate 75 mm thick as in plinth protection and similar works finished fair even laid in bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed
103Taking down carefully copper/aluminium point wiring from wooden battan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including fittings (such as switches, ceiling roses, pendants, regulator, sockets etc) and making good disturbed surfaces of walls, floor etc.
104Taking down old DBs including existing MCCBs,MCB TPN and connected items of any make and type from the site and making good surface complete all as specified and directed.
105Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
106Taking down old unsv light fitting,Security light ,bulb of any size and make from the site and making good surface complete all as specified and directed.
107M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and its also including various sizes of module frame, plates in gray/white colour also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly complete all as speccified and as directed
108One light/fan point controlled by one way switch ( switch to be measured and paid separtely)
109One socket outlet on same board.
110One light point controlled by two way switch.
111One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
112-ditto- as above item No 100.04 but copper conductor 2.5 sqmm for 15 amp socket outlet.
113M & L for power point with insulated stranded copper conductor cable 4 Sqmm single core two run and PVC insulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to earth dolly complete (socket and switches to be measured and paid separately)
114S & F in repair incl making existing surface good sheet metal enclosures with socket plug top and MCB's with two pin and earth plug and socket complete with one single pole MCB 240 V grade 20 Amp.(AC Box) complete all as directed by EIC.
115S & F in repair of modular switch single pole one way 6 Amps, 1 module ISI marked complete all as specified and directed by EIC.
116S & F in repair of modular socket single pole one way 6 Amp-2/3 pin, 2 module ISI marked complete all as specified and directed by EIC.
117S & F in repair of modular switch single pole one way 16 Amps, 1 module ISI marked complete all as specified and directed by EIC.
118S & F in repair of modular socket single pole one way 16 Amp-2/3 PIN, 2 module ISI marked complete all as specified and directed by EIC
119Supply and Fix in repair of call bell Ding Dong ISI marked complete all as specified and directed by Engr in Charge
120Supply and fix in repair of bell push flush type SP 5 Amp complete all as specified and directed by EIC..
121S & F in repair of switch piano type flush type single pole one way 5 Amps, ISI marked complete all as directed by EIC.
122S & F in repair of socket outlet 5 pin flush 6 Amp multi pin 2/3 pin complete all as directed by EIC.
123S & F in repair of switch socket combined outlet 6 pin flush 16 Amp multi, ISI marked complete all as directed by EIC.
124S & F in repair of switch piano type/flush button type single pole two way 5 Amps front operated ISI marked complete all as directed by EIC.
125S & F in repair of lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings complete all as directed by EIC.
126S & F in repair of ceiling fan regulator stepped type 2 module ISI marked, complete all as specified and directed by EIC
127S & F in repair of 3 pin plug top AC-230V, 6 Amp complete all as directed by EIC.
128S & F in repair of 3 pin plug top AC-230V, 16 Amp complete all as directed by EIC.
129S&F in repair ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and directed by Engr-in- charge.
130S & F in repair of High lam sheet cover ISI marked with required Nos of space for switches/ Sockets/ Regulator of size 250x280mm complete all as directed by EIC.
131S & F in repair incl taking down LED bulb 12 Watt with very high efficiency suited for installation in existing lamp holders, complete all as as directed by EIC.
132M & L Submain wiring with two run single core 10 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in concealed New PVC conduit 25 mm dia ISI marked alongwith one run of 10 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 10 sqmm cable and one run of PVC conduit shall be measured as one RM.
133M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in concealed New PVC conduit 25mm dia ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
134Material & Labour for sub main wiring with two run of 4 sqmm size PVC insulated multi stranded copper conductor fire retardanr cable (Nominal area) and one run of 4 sqmm size PVC insulated unsheathed solid core copper conductor cable drawn in either existing or new surface/ recessed steel/ PVC conduit/ PVC casing capping of required size complete all as directed by EIC. Note: Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
135Material & Labour for sub main wiring with two run of 2.5 sqmm size PVC insulated multi stranded copper conductor fire retardanr cable (Nominal area) and one run of 2.5 sqmm size PVC insulated unsheathed solid core copper conductor cable drawn in either existing or new surface/ recessed steel/ PVC conduit/ PVC casing capping of required size complete all as directed by Engr-in-charge.Note: Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
136S & F in replacement LED batten luminaire surface/wall mounted ,4 feet 20 Watts comprise of aluminium extruded with anodised with powder coated in white colour with decorative end cap. The luminare is pre-wired with high efficiency electronic driver, with lifetime of 50000 burning hours . CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6000 to 6500K, surge protection DM-4KV & CM-3KV, IP-40 protected, meets LED IS specifications, Class -1, Short circuit and over circuit protection, voltage range - 140 to 300 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 lm/w, filiker free and including connecting up with PVC sheathed suitable size copper conductor with push type cable connector 2/3 pin cable connector from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings complete all as specified and directed by EIC.
137S & F in replacement LED batten luminaire surface/wall mounted, 2 feet 10 Watts comprise of aluminium extruded with anodised thermally conductive material with powder coated in white colour with decorative end cap. The luminare is pre wired with high efficacy electronic driver, with lifetime of 50000 burning hours . CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6000 to 6500K, surge protection DM-4KV & CM-3KV, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 140 to 300 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 lm/w, filiker free and including connecting up with PVC sheathed suitable size copper conductor with push type cable connector 2/3 pin cable connector from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings complete all as specified and directed by EIC.
138S&F 30 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is 6000 to 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
139S&F sheet metal enclosure for VT DB TPN, MCCB DB TPN 4 way, with 200 A rated bus bar, double door with 100 Amp,25 KA,TP MCCB as incomer (Vertical type double door,100 Amps MCCB rate inclusive) 200 Amp rated bus-bar and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection including wooden rectangle board of first quality of suitable size for mounting of DB box with provision for 4 Pole MCCB* as incomer and SP/TP MCB's as outgoingscomplete all as specified and directed.
140M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing medium grade and necessary fitting for protection of earth lead incl laying of charcoal dust and common salt, precast PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed by EIC
141S&F in repair of SPN DB 8 way with 200 Amp rated bus bar, IP 43, ISI marked acrylic double door complete all as directed by EIC. Note: - Contractor must provides IP43 certificate.
142S&F in repair of SPN DB 12 way with 200 Amp rated bus bar, IP 43, ISI marked acrylic double door complete all as directed by EIC. Note: - Contractor must provides IP43 certificate.
143S & F in repair amp rating 240V 10 KA'B' curve MCB SPN 32-40 A current currying capacity in the MCB DB complete with connection testing and commissioing complete all as specified and directed by EIC
144S & F in repair of MCB TPN 40 to 63 Amps, 415 V with thimble suitable for existing wires complete all as directed by EIC.
145S & F in repair amp rating 240V 10 KA'B' curve MCB SP 6-32 Amp current currying capacity in the MCB DB complete with connection testing and commissioing complete all as specified and directed by EIC.
146Supply and Fix in repair 100 A MCCB 4 pole, 16 kA breaking capacity, 415 V ( Ics=100% Icu ) with suitable thimbles all as specified and directed by Engr-in-charge
147Supply and Fix in repair 63 A MCCB 4 pole, 16 kA breaking capacity, 415 V ( Ics=100% Icu ) with suitable thimbles all as specified and directed by Engr-in-charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56216527
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Maintenance Work To Md Accn For Jcos / Or At Dronachal Top Under Ge Dronachal
Basic Detail
Tender No 8981/E8
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 30 Jun 2026
Submission Date 14 Jul 2026
Open Date 16 Jul 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Available
Document List
SOC_8981.pdf
Tendernotice_1.pdf
9a801af2-f216-4d8b-aef5-202ae5c0503d.html
BOQ_868227.xls
GPSC_8981.pdf
PS_8981.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

SOC_8981.pdf

pdf

Tendernotice_1.pdf

html

9a801af2-f216-4d8b-aef5-202ae5c0503d.html

xls

BOQ_868227.xls

pdf

GPSC_8981.pdf

pdf

PS_8981.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail