Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56216522

Tender For Rep/ Replacement Of Elect Fittings And Fixtures, Dbs, Wiring, Sub Main Wiring, Earthing Etc, Rep/ Overhauling Of Ceiling Fans, Exhaust Fan, Wall Fans, Air Circulators, Geysers, Summer Cooling Appliances At Certain Bldgs Of Tech Area, Resid

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
30 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
18 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Rep/ Replacement Of Elect Fittings And Fixtures, Dbs, Wiring, Sub Main Wiring, Earthing Etc, Rep/ Overhauling Of Ceiling Fans, Exhaust Fan, Wall Fans, Air Circulators, Geysers, Summer Cooling Appliances At Certain Bldgs Of Tech Area, Residential Area Type Iv & V Qtrs Area At Vrde Ahmednagar

BOQ

Name of Work:- REP/ REPLACEMENT OF ELECT FITTINGS AND FIXTURES, DBS, WIRING, SUB MAIN WIRING, EARTHING ETC, REP/ OVERHAULING OF CEILING FANS, EXHAUST FAN, WALL FANS, AIR CIRCULATORS, GEYSERS, SUMMER COOLING APPLIANCES AT CERTAIN BLDGS OF TECH AREA, RESIDENTIAL AREA TYPE IV & V QTRS AREA AT VRDE AHMEDNAGAR
Sl. No. Item Description
1Taking down carefully aluminium point wiring ( light, Fan, socket or power) complete including fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of walls, ceilings and floors etc complete all as specified and directed.
2Taking down unserviceable DB's any type carefully disconnecting and making good disturbed surfaces complete all as specified and directed.
3Taking down unserviceable MCBs/Isolator/DP any rating and size complete all as specified and directed.
4Taking down old/unserviceable light fitting from wall, ceiling etc any type complete all as specified and directed.
5M & L for point wiring with single core PVC insulated and unsheathed 1100 volts grade FRLS electric cable with multistranded copper conductor of size 1.5 sqmm (nominal area) drawn through & including PVC casing and caping, medium duty (ISI marked) on wall, ceiling with GI screws, rawl plugs with all fittings including tees, junction boxes & provision of pressed steel terminal box powder coated of suitable size with 3mm thick plastic laminated sheet cover for mounting switches, sockets & regulators & drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5sqmm (nominal area) complete all as specified and directed. (a) For one light point controlled by one single pole switch.
6(b) For one ceiling fan/exhaust fan/wall and wall mounted fan point controlled by one singel pole switch.
7(c) For one 3 pin, 5 Amp socket oultet on independent board.
8(d) For one 3 pin, 5 Amp socket oultet on same board with other switches.
9(e) For one bell/buzzer point controlled by one bell push button on independent board.
10(f) For one light point controlled by two 2-way switches.
11All as per item herein above but for 3 pin socket outlet 15 Amp on independent board with other circuit with the cable of 2.5 sqmm size and earth continuity conductior of 2.5 sqmm size PVC insulated copper stranded conductor cable complete all as specified and directed.(Switch and socket shall be paid separately)
12All as per item herein above but for single pole and neutral with a two pin and earth plug and socket outlet on independent board with other circuit with the cable of 4 sqmm size and earth continuity conductior of 4 sqmm size PVC insulated copper stranded conductor cable complete all as specified and directed.(PVC enclosure with plug & socket shall be paid separately).
13M & L for point wiring with single core PVC insulated and unsheathed 1100 volts grade FRLS electric cable with multistranded copper conductor of size 1.5 sqmm (nominal area) drawn through surface/ consealed / recessed steel / PVC conduit, including wall clamp, tees, junction boxes where required to repair existing conduit & provision of pressed steel terminal box powder coated of suitable size with 3mm thick plastic laminated sheet cover for mounting switches, sockets & regulators & drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 sqmm (nominal area) complete all as specified and directed. (a) For one light point controlled by one single pole switch.
14(b) For one ceiling fan/exhaust fan/wall and wall mounted fan point controlled by one singel pole switch.
15(c) For one 3 pin, 5 Amp socket oultet on independent board.
16(d) For one 3 pin, 5 Amp socket oultet on same board with other switches.
17(e) For one bell/buzzer point controlled by one bell push button on independent board.
18All as per item herein above but for 3 pin socket outlet 15 Amp on independent board with the cable of 2.5 sqmm size and earth continuity conductior of 2.5 sqmm size PVC insulated copper stranded conductor cable complete all as specified and directed. (Switch and socket shall be paid separately)
19S & F switch socket combination 2 in 1 , 3 pin 15 Amp flush/box type complete as per site requirement complete all as specified and directed.
20S & F socket outlet 5 pin 5 Amps flush type complete all as specified and directed.
21S & F switch socket combination 2 in 1 , 3 pin 5 Amp flush/box type complete as per site requirement complete all as specified and directed.
22S & F switch piano, flush button 15 Amps single pole, one way complete all as specified and directed.
23S & F switch piano, flush button 5 Amps single pole, one way complete all as specified and directed.
24S&F bell push flush type 5 Amp complete all as specified and directed.
25S & F bell, AC 230 V, single pole complete all as specified and directed.
26S & F socket outlet Modular type 6A/16A Amps, 2/3 Pin combined 2 Module complete all as specified and directed.
27S & F socket outlet 5 pin 5 Amps Modular type complete all as specified and directed.
28S & F switch Modular button 15 Amps single pole, one way complete all as specified and directed.
29S & F switch Modular button 5 Amps single pole, one way complete all as specified and directed.
30S&F Modular bell push flush type 5 Amp complete all as specified and directed.
31S&F Modular 16A switch socket combination complete all as specified and directed.
32S & F in replacement the following accessories:-(a) White cover plate with frame, 6 module complete all as specified and directed.
33(b) White cover plate with frame, 4 module complete all as specified and directed.
34(c) White cover plate with frame, 2 module complete all as specified and directed.
35(d) White cover plate with frame, 1 module complete all as specified and directed.
36Supply & fix in replacement the following accessories :-(a) Metal flush box, 6 module complete all as specified and directed.
37(b) Metal flush box, 4 module complete all as specified and directed.
38(c) Metal flush box, 1 or 2 module complete all as specified and directed.
39Supply and fixing ceiling rose, surface, backlite 2 to 3 terminals 65mm x 50mm complete all as specified and directed.
40Supply and fixing in repair stepped type electronic fan regulator complete all as specified and directed.
41S&Fin repair lamp holder 230 volt, AC, PVC/polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
42S & F in repair Modular DB Box for AC connection including 20A MCB protected 3Way with socket Cover plate AC Point complete all as specified and directed.
43Taking down old aluminium unserviceable sub main wiring/cable of any type complete all as specified and directed.
44M & L for sub main wiring with two single core PVC insualted unsheathed stranded copper conductor cable 4 sqmm size drawn through existing surface/recessed/consealed PVC/steel conduit with all accessories including continuous earth wire PVC insualted unsheathed cable 4 sqmm copper stranded conductor and connection to common earth and earth dolly including conneciting to main board complete all as specified and directed.
45All as per item herein above of 6 sqmm and one run of 6 sqmm as earth wire complete all as specified and directed.
46All as per item herein above but four run of 6 sqmm and two run of 6 sqmm as earth wire including with new PVC conduit complete all as specified and directed.
47S & F in replacement LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
48S & F in replacement LED tube rod 18 watt with single side connection complete including remove electronic/copper ballast from existing batten and make necessary electric connections with suitable size of copper wire complete all as specified and directed.
49S & F in repair energy saving recessed/Surface mounting LED 36 watt low glare luminaries suitable for 600mm x 600mm modular/POP/Gypsum ceiling, false ceiling type with all accessoreis pre-wired complete all as specified and directed.
50S & F in replacement LED batten light 10 watt mirror light fitting wall mounted with tubelight including making necessary electrical connection to the fitting using flexible copper cable 3 core 23/0.0076 from ceiling rose to light fitting complete all as specified and directed.
51S & F in replacement round shape 15 watt / 24 watt 220 volts AC Surface/ recess type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
52S & F in replacement suspension (Pendant) mounting LED light 25 watt, 4 feet long luminaires including with hanging chain /rod including making necessary electrical connection to the fitting using flexible copper cable 3 core 23/0.0076 from ceiling rose to light fitting complete all as specified and directed.
53S & F in repair Building/street security LED light fittings of Cap 35 W 230V AC outdoor type with high pressure,corrosion resistant suitable for new generation energy saving and environmental friendly long life, light madeup of pressure diecast aluminium housing with highly efficient LEDs as lighting source and pc cover with integrated lens with IP66 protection and impact resistance of IK07 complete all as specified and directed.
54S & F in replacement of energy saving, enviromental friendly highbay fitting with highpower COM LED as light source of 120 W complete all as specified and directed.
55S & F sheet steel enclosure MCB DB's factory fabricated phosphatised powder painted,Single pole & neutral, with 200 Amp rated bus-bar, 240 volt, AC ,8 ways, double door type complete all as specified and directed.
56All as per item herein above but SPN 12 way double door complete all as specified and directed.
57S & F sheet steel enclosure MCB DB's factory fabricated phosphatised powder painted, tripple pole & neutral, with 200 Amp rated bus-bar, 415 volt, AC , 4 ways, double door type complete all as specified and directed.
58All as per item herein above but TPN 8 way double door complete all as specified and directed.
59S & F in repairs MCB, Single pole 6-32 Amps, 240 volts complete all as specified and directed.
60S & F in repairs MCB, Single pole and neutral, 32 Amps, 240 volts complete all as specified and directed.
61All as per item herein above but SPN 63 Amps complete all as specified and directed.
62S & F in repairs MCB, triple pole and neutral, 63 Amps, 415 volts complete all as specified and directed.
63All as per item herein above but TP 63 Amps complete all as specified and directed.
64S & F in repairs sheet metal enclosure industrial type complete with plug and socket 5 pin ( 3 phase+1 N+1E) including three pole MCB 32 Amps breaking capacity 6 kA complete all as specified and directed.
65M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre deep below ground level with top edge of the plate not less than 1.5 metre below normal ground level and connected to earth plate surrounded by 15cm thick packed layers of charcoal dust and common salt and conected to GI wire 4mm dia by means of bolts, nuts check nuts and wahsers of galvaised iron or steel and thimbles and otehr end of the earth wire connected to DB and protected by galvaised iron or steel pipe light grade 15mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and Rcc cover all as shown in Electrical Plate No 3. complete all as specified and directed including dismantling/ taking down of existing earthing.
66Supply & fix in repair cable PVC FRLSH insulated unsheathed stranded copper conductor 2.5 Sqmm 2 core complete all as specified and directed.
67Supply & fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core complete all as specified and directed including taking down existing u/s cable.
68Supply & fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core complete all as specified and directed including taking down existing old cable.
69Supply & fix in repair fan condensor 2.5 mfd complete all as specified and directed.
70Taking down the defective ceiling fan of 1200/1400 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the ceiling fan by throughly cleaning the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly complete all as specified and directed. (Note : Spare parts will be measured & paid as separate items)
71M & L for Re-winding the ceiling fan 1200/1400 mm sweep with same guage supper enamelled copper wire complete all as specified and directed.
72Taking down the defective Exhaust fan 300 mm sweep any make and any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the exhaust fan by throughly cleaning/changing the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly complete all as specified and directed. (Note : Spare parts will be measured & paid as separate items)
73M& L for Re-winding the exhaust fan with same guage supper enamelled copper wire complete all as specified and directed.
74Taking down the defective Exhaust fan 450 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the exhaust fan by throughly cleaning/changing the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly complete all as specified and directed. (Note : Spare parts will be measured & paid as separate items)
75M & L for re-winding the exhaust fan with same guage supper enamelled copper wire complete all as specified and directed.
76Taking down the defective Wall mounted fan 450 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running including servicing/overhauling the Wall mounted fan by throughly cleaning/changing the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly complete all as specified and directed. (Note : Spare parts will be measured & paid as separate items)
77M & L for re-winding the wall fan with same guage supper enamelled copper wire complete all as specified and as directed.
78Taking down the defective Air circulator fan 600 mm sweep any make any height from Tech area, Resi area, NCAT area after disconnecting electrical connection and transporting to workshop for examine and carry out the repairs as required and brought back to site, refixing, testing in all respect for smooth running includingservicing/overhauling the Air circulator fan by throughly cleaning/changing the bearing, shaft, stator, rotor & appling the lubricant/grease to the bearing, replacement the wornout, unserviceable screw assembly complete all as specified and directed. (Note : Spare parts will be measured & paid as separate items)
79M & L for re-winding the air circulator fan with same guage supper enamelled copper wire complete all as specified and as directed.
80Supply & Fix ball bearing of 1200 mm/1400mm ceiling fans & 450mm exhaust fan complete all as specified and as directed.
81S & F in repairs ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed.
82S & F in repairs exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
83Inspection and maintenance of water heater (Geysers) of capacity, 25 ltrs to 50 litres including performing the following task at different locations at VRDE complete all as specified and directed:-(a) Removing the heather plate assembly and descaling the heating element/pipe either by use of acid or equa cleaner to make it functional complete all as specified and directed.(b) Checking and setting of thermostat between 70 to 80 degree Celsius complete all as specified and directed.(c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional complete all as specified and directed.(d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional complete all as specified and directed.(e) Examine water leakage and rectifying copper tank and making soldering & brazing as required and replacement of rubber washer gasket etc to make it functional complete all as specified and directed. (f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional complete all as specified and directed.Note :- Spare parts will be measured and paid for separatly)
84Supply & fix of heating element of rating 1.5 to 2 KW to geyser 25 to 50 litres capacity, any type, complete all as specified and as directed.
85Supply & fix of the thermostat (adjustable type) suitable for upto 50 litres capacity of geysers complete all as specified and directed.
86Supplying and fixing in replacement of geyser plate assembly suitable for 25 to 50 litres capacity geysers, of brass with inlet, outlet pipe, drain plug, thermostat chamber fixing heating element gasket nut, bolt etc are fixing the assembly to make it functional complete all as specified and directed.
87Supply & fix of flexible PVC pipe connection, heavy duty nylon thread reinforced 15 mm dia, 450 mm long with brass union at both ends for 15 mm dia pipe complete all as specified and as directed.
88Supply & Fix gasket of thickness 5 mm for geyser assembly of 08 holes/09 holes complete all as specified and directed.
89S&F non return valve for geyser complete all as specified and directed.
90Supply & fix fastner mild steel 100/150/200 mm long complete all as specified and directed.
91Taking down /out from existing position window type AC's of capacity 1.5/2TR, servicing the same by cleaning, dusting with blower, checking wiring, nuts, bolts, electrical contacts, tightening all loosened parts as required,setting grills and fan blades for proper functioning, oiling, greasing to moving parts including replacing defective parts and sleaves etc and refixing the same to its original position and testing for smooth functioning complete all as specified and as directed.
92Taking down /out from existing position split type AC's indoor & outdoor units of capacity 1.5/2TR, servicing the same by repairing minor problem & cleaning, dusting with blower, checking wiring, nuts, bolts, electrical contacts, tightening all loosened parts as required,setting grills and fan blades for proper functioning, oiling, greasing to moving parts including replacing defective parts and sleaves etc and refixing the same to its original position and testing for smooth functioning complete all as specified and as directed.
93All as per item herein above, but refigerator & deep freezer capacity 165 ltrs to 350 ltrs complete all as specified and directed.
94All as per item herein above, but water cooler capacity 40 ltrs to 150 ltrs complete all as specified and directed.
95Disconnecting burnt out compressor from existing electric and pipe line connections of refrigerator/ deep freezer of capacity up to 300/350 ltr of any make and replacing the same with factory made reconditioned compressor including connecting suction and discharge line by cooler brazing complete all as specified and directed.
96All as per item herein above, but water cooler of capacity 40/80 ltrs complete all as specified and as directed.
97All as per item herein above, but water cooler of capacity 60/120/150 ltrs complete all as specified and as directed.
98All as per item herein above, but Window / Split type AC of capacity 1.5 TR complete all as specified and as directed.
99All as per item herein above, but Window / Split type AC of capacity 2 TR complete all as specified and as directed.
100S&F in replacement condensor fan motor for water coolers any capacity.suitable for water cooler of capacity 40/80, 60/120 & 60/150 liters complete all as specified and directed.
101S&F in replacement blower fan motor for window AC of capacity 1.5 TR complete all as specified and as directed.
102S&F in replacement blower fan motor for window AC of capacity 2 TR complete all as specified and as directed.
103S&F in replacement blower fan motor for split type AC in door unit of capacity 1.5 TR complete all as specified and as directed.
104S&F in replacement blower fan motor for split type AC in door unit of capacity 2 TR complete all as specified and as directed.
105S&F in replacement condensor motor for split type AC out door unit of capacity 1.5 TR complete all as specified and as directed.
106S&F in replacement condensor motor for split type AC out door unit of capacity 2 TR complete all as specified and as directed.
107S&F in replacement fan motor of 230 volt, 50 Hz, SP suitable for desert cooler of capacity 3000/5000 cum per hour complete all as specified and as directed.
108Supply and charging only refrigerent gas of required HD ie Hydrocarbon, 134, R-22 or R-12 or any latest version for refrigerators / Deep freezer of capacity up to 310 lts including cutting copper pipe and sealing by brazing etc after charging gas as required and leak testing complete all as specified and as directed.
109All as per item herein above, but for water coolers of capacity 40/80, 60/120, 150/150 ltr capacity complete all as specified and as directed.
110All as per item herein above, but for window/split type AC of capacity 1.5 TR complete all as specified and as directed.
111All as per item herein above, but for window/split type AC of capacity 2 TR complete all as specified and as directed.
112Supply & fix in replacement running/starter capacitor 2.5/3.15/4.0/6.0 mfd, 230 volt, AC for cooling appaliances complete all as specified and as directed.
113All as per item herein above, but of 10.0/15.0 mfd complete all as aspecified and as directed.
114All as per item herein above, but of 36.0/45.0 mfd complete all as aspecified and as directed.
115All as per item herein above, but of 40.0/60.0 mfd complete all as aspecified and as directed.
116Supply & fix in replacement thermostate suitable for window/split type AC's water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing complete all as specified and as directed.
117S & F in replacement box type relay or package assembly from suitable window type AC's of capacity 1.5/2 TR complete all as specified and as directed.
118All as per item herein above, but for split type AC's of capacity 1.5/2 TR complete all as aspecified and as directed.
119All as per item herein above, but for water coolers capacity 40/80, 60/120 & 60/150 ltrs complete all as aspecified and as directed.
120S&F in replacement 15mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed in water coolers complete all as aspecified and as directed.
121S&F in replacement 15mm dia stop valve, cromium plated screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as aspecified and as directed.
122S&F in replacement PVC connection 600 mm long with brass ends terminals suitable for water coolers complete all as aspecified and as directed.
123S&F in replacement PVC pipe 32mm dia for draining out waste water complete all as aspecified and as directed.
124S&F in replacement fan blade set for water coolers fan motor complete all as aspecified and as directed.
125S & F in replacement Plug top 3 pin, 230 volt 16 Amps complete all as specified and directed.
126S & F in replacement Air filter PVC type of existing window / split type AC's of capacity 1.5/2 TR complete all as specified and directed.
127S&F in replacement AC Outdoor unit 1.5 TR split type, complete all as specified and as directed.
128S&F in replacement AC Outdoor unit 2.0 TR split type, complete all as specified and as directed.
129S & F in replacement Sedimentation/ carbon filter set for Water purifier complete all as specified and directed.
130S&F in replacement of SMPS kit for water filter unit of any make including testing complete all as specified and as directed.
131S&F in replacement Heat insulation pipe for wrapping copper tape duly fixed with polythelene type to suction and discharge lines for existing window/split type AC's 1.5/2 TR from any position or any make including testing complete all as specified and as directed.
132S&F in replacement Electronic card/PCB of existing window/split type AC's of capacity 1.5 / 2 TR including testing complete all as specified and as directed.
133Supply & fix wood wool pads of best quality as approved with and including wire mesh jalli for desert cooler of any size make and capacity all as specified and as directed.
134S&F in replacement water pump, 230 volt, 50 Hz, SP with discharge head 1.87 mtr for desert cooler of any capacity complete all as specified and as directed.
135S&F in replacement AC indoor unit 1.5 TR split type, complete all as specified and as directed.
136S&F in replacement AC indoor unit 2.0 TR split type, complete all as specified and as directed.
137To attend any break down & checking the electrical connections & wiring of equipment and rectify the problem of summer appliances ie. Split type AC's, window type AC's, water coolers, refrigerator,deep freezer, desert coolers, package type Acs of any capacity or make/model, installed at VRDE complex as and when required during working/non working hours complete all as specified and directed. Note :- (i) If Spares will be required in particular complaint then the item will not be measured in this item it will be measured & paid separately under relevent items.
138Taking down/out the blower/condensor fan motor of any make and capacity, transporting to workshop, opening up, cleaning, taking out burnt winding etc, and rewinding of motor with superior quality of enamelled copper wire of same guage, reassembling and fixing back at the same position including testing and making necessary connection complete all as specified and as directed. (a) Blower fan motor (Two speed i.e. low and high for window type AC of capacity 1/5 HP capacity)
139(b) Condensor fan motor for water cooler1/6 HP Capacity.
140(c) Air cooler fan motor having three speed, single phase 230 volts, 50 Hz of 380 to 450mm sweep.
141(d) Condensor fan motor for split type AC of capacity 1.5 TR.
142(e) Blower fan motor for split type AC of capacity 1.5 TR.
143(f) Condensor fan motor for split type AC of capacity 2 TR.
144(g) Blower fan motor for split type AC of capacity 2 TR.
145Taking down/out window / split type AC 1.5/2 TR capacity of any make, from existing position, transporting and refixing at new location including cutting chasing of wall making necessary connections to make it functional complete all as specified and directed.Note : Gas charging and/or parts if required shall be measured and paid separetely.
146Detecting gas leakage of water cooler, refrigerators, deep freezers, window type AC's and split type AC's and rectifying / arresting the leakages, testing for pressure drop complete all as specified and as directed.Note : Gas charging shall be measured and paid separetely.
147S&F in repair selector switch 3 way for AC 1.5/2 ton complete all as specified and directed.
148Supply & Fix PCB board for Inverter type AC of 1.5 /2.0 TR capacity complete all as specified and directed.
149S&F copper tubing along with necessary insulation as per manufacture standerd for 1.5/2 TR split AC unit, copper tubing pipe 3/8\\" for split type AC including provision of insulation on tubing complete all as specified and directed.
150.S&F copper tubing along with necessary insulation as per manufacture standerd for 1.5/2 TR split AC unit, copper tubing pipe 5/8\\" for split type AC including provision of insulation on tubing complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56216522
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Rep/ Replacement Of Elect Fittings And Fixtures, Dbs, Wiring, Sub Main Wiring, Earthing Etc, Rep/ Overhauling Of Ceiling Fans, Exhaust Fan, Wall Fans, Air Circulators, Geysers, Summer Cooling Appliances At Certain Bldgs Of Tech Area, Residential Area Type Iv & V Qtrs Area At Vrde Ahmednagar
Basic Detail
Tender No GE I R AND D GNR TOKEN 27 OF 2026-27(8015)
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 30 Jun 2026
Submission Date 21 Jul 2026
Open Date 23 Jul 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
3fcf916d-1822-4a10-a5f8-6b982c5d1516.html
BOQ_868236.xls
TENDERDOCUMENTS.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Jul 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

3fcf916d-1822-4a10-a5f8-6b982c5d1516.html

xls

BOQ_868236.xls

pdf

TENDERDOCUMENTS.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders