Tender For Development Of Sports Center (Cricket Stadium & Swimming Pool ) At Nayapura , Kota
Tender Value
134.15 Crore
Estimated cost
Bid Submission
29 Jul 2026
27 days left
EMD
2.68 Crore
Bank guarantee accepted
Document Fee
7500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kota → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Development Of Sports Center (Cricket Stadium & Swimming Pool ) At Nayapura , Kota
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. |
| 2 | 1: 3: 6 or richer mix. |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 4 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | In cement mortar. |
| 7 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: |
| 8 | In cement mortar. |
| 9 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead: |
| 10 | Of area 3 square meter and below. |
| 11 | Of area exceeding 3 square meter. |
| 12 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. |
| 13 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: |
| 14 | For thickness of tiles 10mm to 25mm. |
| 15 | For thickness of tiles 25mm to 40mm. |
| 16 | Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 17 | Dismantling roofing including ridges, hips, valleys and rafters etc. and stacking the within 50 meter lead of: |
| 18 | G.I. Sheet. |
| 19 | Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: |
| 20 | Dismantling GI pipes (external work) including excavation and refilling trenches after taking out the pipes and including stacking of pipes within 50 meter lead: |
| 21 | 15mm to 40mm nominal bore. |
| 22 | Above 40mm nominal bore. |
| 23 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 24 | Removing aluminium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 25 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer-in-charge : |
| 26 | Water bound macadam road (average thickness 250 mm) |
| 27 | bituminous road (average thickness 300 mm) |
| 28 | Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed : All kinds of soil |
| 29 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 30 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 31 | Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in |
| 32 | All kinds of soil |
| 33 | Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . |
| 34 | Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand |
| 35 | Random rubble dry stone Kharanja under floor. |
| 36 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 37 | M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 38 | Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20 grade Design Mix by using cement as per codal provision. |
| 39 | Providing M-30 grade concrete by using cement as per codal provision instead of M-20 grade design mix. |
| 40 | Qty same as item above ( BSR item No. 4.5) |
| 41 | Add extra for RCC work in superstructure above floor five level for each four floor or part thereof |
| 42 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 43 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: |
| 44 | Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 45 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : |
| 46 | Walls (any thickness) including attached pilasters, buttresses plinth and string course. |
| 47 | Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 48 | Columns, pillars, posts and struts etc. |
| 49 | Add extra for shuttering in circular work (in respective centering and shuttering items) |
| 50 | Add extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured |
| 51 | Add extra for centering and shuttering work in superstructure above floor five level for each four floor or part thereof . |
| 52 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786 |
| 53 | Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 54 | Add extra for reinforcement in superstructure above floor five level for each four floor or part thereof . |
| 55 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : |
| 56 | Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 57 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 |
| 58 | Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 59 | Providing Factory Made 100% Solid WPC (Wood polymer Composite) Board of 18mm thicknesss of required size comprising of virign PVC resin of K Value 58-60 ( Suspemsion Grade), Calcium Corbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk) and Non toxic additives , made from Extrusion process WPC foam sheet Single Extruded ( Inner) with density not less than 550 kg/cbm manufactured by an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withrawal strength of 1800 N ( Face) & 900 N ( Edge), Minimum Compissive Stength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance of spread of flam of Class A caegory wih Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. |
| 60 | All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For KITCHEN CABINET & CUPBOARDS.. |
| 61 | Providing & fixing factory made 100% Solid WPC (Wood Polymer Composite) Door Frame 90mm x 45 mm ( Moulded ) Single Rebated,, made from Wood Polymer Composite (Single Extruded Process) material comparising of virign PVC polymer of K Value 58-60 ( Suspemsion Grade), Calcium Corbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk) and Nor toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed srews having minimum frame density of 780 kg/ cbm & manufactured by an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withrawal strength of 2200 N ( Face) & 1100 N ( Edge), |
| 62 | Minimum Compissive Stength of 58 N/mm2, Moduus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in postion with SS Dash Fasterns / Hold Fast of reuired dia and lenght, all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company ( Hold Fast or Dash Fastners shall be paid seperately) |
| 63 | Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shutter shall be made of 39w x 69h mm Extruded 3 box multi-chamber UPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. |
| 64 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in– charge .(Glazing and paneling to be paid for separately). |
| 65 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). |
| 66 | Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 67 | Extra for shutters of sliding aluminum windows |
| 68 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) |
| 69 | With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) |
| 70 | Extra for providing toughened glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 71 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. |
| 72 | With stainless steel cover plate |
| 73 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment). |
| 74 | Providing & fixing ball bearing for rolling shutters |
| 75 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. |
| 76 | Exceeding 10.00 Sqm and upto 16.80 Sqm in the area. |
| 77 | Providing and fixing fully panelled/partly panelled/ double leaf shutter frame for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - 'A' and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : |
| 78 | 35 mm thick |
| 79 | Nigeria wood grade I |
| 80 | Supply and fixing of solid stainless steel grade 304 C type door handle of dia 32mm length 600 (outside measurement) having hole dia 14 mm of with i/c key arrangement. |
| 81 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : |
| 82 | 35 mm thick . |
| 83 | Decorative teak veneer One side |
| 84 | Extra for providing other type of fittings as mention in annexure A ( as approved by EI) |
| 85 | Stainless steel fittings |
| 86 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. |
| 87 | Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area of the shutter to be measured). |
| 88 | Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge. |
| 89 | 0.8mm thick mica |
| 90 | Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : |
| 91 | Sal wood Grade - I. |
| 92 | Ghana teak wood Grade - I. |
| 93 | Providing and applying Melamine polish on teak wood work of approved brand and manufacture to give an even shade with two or more coats by compressor including sand papering, wood filler coat etc complete in all respect: |
| 94 | New Surface |
| 95 | Providing & Fixing decorative veneer of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge. |
| 96 | 4.0mm thick veneer |
| 97 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: |
| 98 | 20 mm |
| 99 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 100 | Providing and Fixing Aluminium composite panel of approved make 3mm thick with 0.5mm thick skin & PVDF coated approved shade for wall panelling. Main framing work to be done using 50mmx25mmx1.6mm tubular section of approved make. Stainless steel screw to be used to fix the ACP panel to be fixed to the main frame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealant suitable for glass/aluminium etc. complete in all respect as approved by Engineer-in-charge. |
| 101 | Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 102 | For area of each slab from 2001 to 5000 Sq.Cm |
| 103 | Extra for Mirror polishing on terrazzo/Kota stone work where ever required to give high gloss finish complete. |
| 104 | Providing and laying M30 grade controlled cement concrete pavements including mixing and vibrations concrete with necessary needle vibrators and surface with screed board vibrating complete in all respect with 20/25 mm stone aggregate (crusher broken) including anti-skid textured finish to required camber/ super elevation and grade including curing etc. as per specification with cement concrete M-30 grade including cost of Steel frame work for sides of C.C. pavement consisting of M. S. channels flats and angles with required steel pegs ( some of them may left embedded in concrete/ including providing frame work) |
| 105 | Extra for vacuum processed concrete including cost of equipments labour etc. |
| 106 | Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size. |
| 107 | Welded mesh 50 mmx 50 mm x 2.1 mm |
| 108 | Providing and Fixing machine made Synthetic Carpet having total Carpet weight 850 gm Psqm. and 5mm thickness superior quality complete in all respect as per direction of Engineer-in-charge. |
| 109 | Providing and Fixing Cushion Vinyl/Fully flexible Vinyl Flooring confirming to I.S.-3462 Flooring of approved make with fibre base using rubber base adhesives including rolling with light wooden roller complete : |
| 110 | 2.0 mm thick. |
| 111 | Precast terrazzo tiles of approved make 20mm thick with marble chips of size upto 6mm in skirting & risers, treads of steps and dados 12mm thick cement plaster 1:3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of : |
| 112 | P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thicknessminimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. |
| 113 | Size 300mm x 450mm |
| 114 | Size 600mm x 600mm |
| 115 | size 600 mm X 1200 mm |
| 116 | P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. |
| 117 | size 600 mm X 600 mm |
| 118 | Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, in average 3mm thickness instead of cement mortar. |
| 119 | Providing & fixing Brown Kota/ Mandana /Dholpur/ Bijoliya /Gwalior Mint/ Teak stone/ slate stone in cladding / Flooring Structural base with Shot blast and or River wash where ever required with white cement & Tinex chemical & SS Clamp and Fasteners (of approved brand) laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attached complete in all respect as per direction of Engineer- In- Charge & Architect with all lead & lift. The Stone measurement will be done of outer most dimension. Thickness of stone 25-30mm. |
| 120 | Providing and laying wooden flooring with a direct laminated surface treated with aluminum oxide on top of a high-density fiber board with a density of 850 Kg./per Mtr. having a click system tongue and groove joint to secure a long lasting joint. The planks are or termite resistant and water protected with both side lamination Wooden flooring Planks of size 1208 x 194 x 8 mm / 1215x294x8 mm (8mm thick laminated floor class of use 23/31 having a wear resistance level of AC-3 , impact resistance > 9mm, moisture resistance 3-10% as per (EN-424, EN– 438 EN– 425 EN– 417– 2)or PREN 3329 complete in all respect as per direction of EI |
| 121 | Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work. |
| 122 | Grading roof for water proofing treatment with water proffing compound |
| 123 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 124 | Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with (Bevelled Tegular) EDGE TILES WITH 15 mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99% NRC 0.5, Light Reflectance _>85%, Thermal Conductivity K =0.052-0.057 w/m K, Colour White, Fire Performance UK Class 0/Class 1 (BS 476 Part 6 & 7), in module size of 600 x 600 x 16 mm, suitable for Green Building application, with Recycled content of 32 %. The tile shall be laid on Silhouette profile grid system with 15 mm white/black flanges incorporating a 6 mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/Sqm minimum pull out strength of 100 kgs. Silhouette, Main Runners & Cross Tees to have mitred ends & \\"birdsmouth\\" notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per sqm and need to be installed with suspension system of make. The Tile & Grid system used together should carry a 30 year warranty. INSTALLATION :- To comprise main runner spaced at 1200 mm centres securely fixed to the structural soffit using suspension system (Specifications below) at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450 mmfrom the adjacent wall. Flush fitting 1200 mm long cross tees to be interlocked between main runners at 600 mm centre to form 1200 x 600 mm module. Cut cross tees longer |
| 125 | Providing and fixing calcium silicate perforated board false ceiling at all heights including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the calcium silicate board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but but excluding the cost of painting of thickness of calcium silicate board as below |
| 126 | 6 mm thick |
| 127 | Providing and fixing tiled false ceiling of approved materials of size 595X595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams per sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24X38 mm made from 0.30 mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24X25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200X600 mm and secondary cross “T” of length 600 mm and size 24X25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200X600 mm panel to form grids of 600X600 mm and wall angle of size 24X24X0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. |
| 128 | Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 X 37 X 25 X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 X 30 X 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 129 | 12.5mm thick square edge PVC laminated Gypsum tiles of size 595mm x 595mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edged and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 130 | Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 |
| 131 | Providing and fixing Ceramic vitrified pool tiles as per FINA standard and approved design and colour of size 247mmx122mmx8mm thick including corner tiles accessories with waterabsorption less than 3% laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete .(including the cost of cement mortar bed 1:4). |
| 132 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : |
| 133 | 20mm thick. |
| 134 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
| 135 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 136 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 137 | Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mm and 10 mm thick as per approved design |
| 138 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 139 | New Plastered Surface (three or more coats) |
| 140 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: |
| 141 | Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 142 | Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision |
| 143 | Trowel Finish av. thickness 1000 to 1200 microns. New Work |
| 144 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 145 | Two or more coats on new work |
| 146 | Providing and fixing to existing door frames. |
| 147 | 30mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mm top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter). |
| 148 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 149 | Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) |
| 150 | Above 3601 Cm2 Slabs |
| 151 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 152 | South Zed Black |
| 153 | Above 3601 Cm2 Slabs |
| 154 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. |
| 155 | Rajasthan Black |
| 156 | Above 3601 Cm2 Slabs |
| 157 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil |
| 158 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 159 | Extra if square,rectangular hollow tubelar sections are used or grill made by flats only |
| 160 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 161 | Providing non slip grooves to granite/ kota stone flooring, counters, vanities etc. using groove cutter V type including machine polishing to groove to give high gloss finish etc. complete as per design approved by engineer in charge |
| 162 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 163 | Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide. |
| 164 | Extra for providing D type pipe head as top of hand railing |
| 165 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades ceramic glazed vitrified tiles with water absortion less than or equal to 0.08% confirming to IS:13753 & IS : 15622 on walls, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 166 | Size 600mm x 1200mm |
| 167 | Providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutter 25 mm to 40 mm thick Wood panel grade I |
| 168 | Ivory coast wood grade I |
| 169 | Providing and fixing 150 mm wide sheet covering over expansion joints with iron screws as per design to match the colour / shade of wall treatment. |
| 170 | Aluminum fluted strips 2 mm thick |
| 171 | Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 172 | Granite/Kota Stone Work |
| 173 | Full Edge moulding |
| 174 | Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick bats complete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification. |
| 175 | Add extra for Square or Rectangular Pillars in Superstructre brick work up to five storey |
| 176 | Upto 45 cm length and two corners are free |
| 177 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 178 | P/F wall mounted foldable hinged (Grab rail) size 750mm x 100mm (LxW) as approved design, made of 35mm stainless steel pipe having anti-bacterial Nylon surface with contour finish for better grip. Grab bar should be mounted on wall between height 200mm to 250mm from the top of W.C seat and extending 100mm to 150mm beyond the front of the W.C. Complete in all respect as per Harmonized guideline & Satisfaction of Engineer-in-Charge. Cera make (B2210108) |
| 179 | Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. |
| 180 | Electric resistance or induction butt welded tubes. |
| 181 | Extra for hoisting and fixing for every additional one metre or part thereof beyond 10 mtr height. |
| 182 | Providing and fixing Structural glazing work with toughened glass of 6mm thick and reflective colour as approved in dark shade like Blue/Dark Blue etc. with frame work of curtain section 65x60mm (Weight 1.64 kg/m min.) made of aluminium with chrome plating. Internal frame work will also be of curtain section 65x60mm of chrome plated aluminium section with20x20mm aluminium tube section and structural spacer made of rubber. The aluminium frame work size as per instruction of Engineer-in-charge and including openable panels with all necesary sections and fitting.The work include silicon structural adhesive for complete gripping of glass with framing members and silicon weather seal sealant to prevent moisture/water through joints. Glass will be fixed in plumb and with uniform spacing of 10-12mm wide duly filled with silicon weather seal sealant. The work includes all labour,scaffolding , structural aluminium work, toughened glasses,silicon weather seal sealant, silicon structural adhesive structural spacer, all accessories like handles, peg stays, M-15 grade cement concrete for fixing holdfast .(Face area of glass shall be measured) |
| 183 | Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-charge including cutting and making good the wall and floor |
| 184 | W.C. orissa pan with 100 mm vitreous china P or S trap (Size 580x440 mm.) |
| 185 | Wall Mounting European type W.C. |
| 186 | Double Syphonic European W.C. with mounted W.V.C. flushing cistern of 10 litre capacity complete with all necessary internal fittings with Hydraulic seat cover. |
| 187 | Providing & Fixing premium qulaity W.V.C. Urinal Partition plate of size 630x315 m |
| 188 | Providing & Fixing premium qulaity WVC Wash basin with C.I. brackets duly painted & 32 mm C.P. brass waste coupling of approved make with PVC waste pipe complete |
| 189 | Size 550 mm x 400 mm dia for counter top. |
| 190 | P &F Premium quality Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make as per Engineer-in charge with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : |
| 191 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 192 | Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern. |
| 193 | Providing & Fixing premium qulaity WVC Urinal with PVC waste pipe, dome couplings, concealed iron brackets or screws etc. complete. |
| 194 | Flat Back (large) or half stall size 590x375x390 mm. |
| 195 | P & F Premium quality water closet Seat Covers with brass hinges complete Solid PVC (ISI marked) grade-I White for EWC |
| 196 | P&F Looking Mirror 5mm thick of approved make with ornamental frame size 50x12 with 6mm Ply Board on Back Side Complete as per approved sample |
| 197 | P & F Grating of approved quality/make: |
| 198 | (-do-) Square 150 x 150 x 8mm. (Anti Cockroach) |
| 199 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : |
| 200 | 1.0mm thick stainless steel AISI-304& IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling. |
| 201 | 24 x 18 x 8 20x16x8 |
| 202 | Providing and fixing Superior quality CPBrass fittings of approved make as per direction of Engineer-in-charge |
| 203 | Bib Cock with long thread 15 mm nominal size |
| 204 | Long body Bib Cock 15 mm nominal size |
| 205 | Sink cock with swinging casted spout (table mounted) 15mm nominal size |
| 206 | 600 mm long towel rail |
| 207 | Soap dish |
| 208 | 190 mm rain shower |
| 209 | Paper holder |
| 210 | Hand shower with 8mm dia 1mt long PVC tube & wall hook complete |
| 211 | JetSpray (Premium heavy Quality)as approved by Engineer in-Charge |
| 212 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. |
| 213 | ---do--- with 60 cm long thread and nut |
| 214 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 215 | 110 mm dia |
| 216 | Providing at site, lowering & laying in trenches, aligning & jointing of PVC-U pipes (SN 8) as per IS 15328 (amended up to date) and as per specifications with rubber rings with socket and spigot joint, (EPDM/SBR) for all depths for pipe length as per drawing and specification including hydraulic field testing (including the cost and conveyance of water to site for testing) and commissioning etc complete as directed by the item of manhole/inspection chamber shall not be payable. Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in |
| 217 | 160 mm Nominal Dia |
| 218 | Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15CM] excluding cost of Pipe & Excavation of trenches etc. |
| 219 | PVC pipe 110 mm dia |
| 220 | PVC pipe 160 mm dia |
| 221 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: |
| 222 | Coupler (socket) |
| 223 | 110 mm dia |
| 224 | Plain Tee |
| 225 | 110 mm dia |
| 226 | Door Tee |
| 227 | 110 mm |
| 228 | Bend 87.5 |
| 229 | 110 mm |
| 230 | Vent Cowel |
| 231 | 110 mm |
| 232 | Pipe clip 110mm |
| 233 | 110 mm |
| 234 | Multi floor trap |
| 235 | Gully trap 110 mm |
| 236 | Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. |
| 237 | Depth up to 0.5 M |
| 238 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. |
| 239 | -do- size 600 x 450mm depth upto 0.5 M Cement cover with frame. |
| 240 | Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: |
| 241 | Size 300 Cm. dia outside & 300 Cm. depth . |
| 242 | Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- |
| 243 | Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. |
| 244 | Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size : |
| 245 | 15mm dia nominal bore |
| 246 | 20mm dia nominal bore |
| 247 | 25mm dia nominal bore |
| 248 | 32mm dia nominal bore |
| 249 | 40mm dia nominal bore |
| 250 | 50mm dia nominal bore |
| 251 | 65mm dia nominal bore |
| 252 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) |
| 253 | 15 mm nominal size |
| 254 | 20mm nominal size |
| 255 | 25 mm nominal size |
| 256 | 32mm nominal size |
| 257 | 40 mm nominal size |
| 258 | 50 mm nominal size |
| 259 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) |
| 260 | 15 mm nominal size |
| 261 | 20mm nominal size |
| 262 | 25 mm nominal size |
| 263 | 32mm nominal size |
| 264 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). |
| 265 | 32mm nominal size |
| 266 | 40 mm nominal size |
| 267 | 50 mm nominal size |
| 268 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : |
| 269 | (-do-) 20mm nominal bore. |
| 270 | (-do-) 32mm nominal bore. |
| 271 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: |
| 272 | 1000 (-do-) |
| 273 | 2000 (-do-) |
| 274 | 5000(-do-) |
| 275 | Hoisting Charges for each floor : |
| 276 | For items 2.26.5 to 2.26.8 |
| 277 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : |
| 278 | (-do-) wt.Not less than 800 gm, 32mm. |
| 279 | Providing & Fixing Premium quality Bottle trap internal portion 32mm, size 250mm long wall connection pipe & wall flange as per approved by Engineer in Charge. |
| 280 | P & F Towel Rail or Ring of approved quality/make: |
| 281 | C.P. Brass Towel Ring revolving type |
| 282 | P & F Liquid Soap Container with brackets complete of approved make: |
| 283 | C.P. brass |
| 284 | P&F Divertors in water supply lines for walls, wash basin etc |
| 285 | P&F Sink Mixture of (Adjustable or Non Adjustable) Superior quality Swan Neck. |
| 286 | Supplying and Fixing of PN 16 Brass/GM Ball valves with screwed end, SS Ball including teflon tape etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 287 | 25 mm nominal dia |
| 288 | 40 mm nominal bore |
| 289 | 50 mm nominal dia |
| 290 | Supplying and Fixing of PN 1.6 Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 291 | 65 mm nominal dia |
| 292 | 100 mm nominal dia |
| 293 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 294 | 25 mm nominal bore |
| 295 | Providing and erecting Drainage Spouts with 0.15m long GI pipe 150mm dia and GI bolt 10mm dia with Galvanised MS flat clamp complete as per drawing and Technical specification as per clause 2705 of MoRT&H specifications including all material, labour, machinery etc. |
| 296 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in-charge. External work |
| 297 | 62.50mm nominal outer dia pipes |
| 298 | 75 mm nominal outer dia pipes |
| 299 | Providing and fixing of Reinforced Ferro cement Drain cover designed for class \\"AA\\" loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti- corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks admixture like plasticizer bond improving compound shrinkage resistance compound abrasion resistant complete as per approved design etc. |
| 300 | for drain Opeining Size 300 to 450 mm Standard Drain Cover Size 600mm x 800mm x 75mm |
| 301 | Providing, lowering, laying, aligning, fixing in position and jointing in pipe line CI Kinetic Double Air Valves as per IS:14845 of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 302 | 100 mm dia |
| 303 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 304 | 40 mm nominal bore |
| 305 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for for Isolating Valve / garden hydrant, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : |
| 306 | Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated CI D/F Sluice valves of approved make (IS: 14846 amended upto date) PN 1.0 class of following dia complete (including jointing and jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. |
| 307 | 80 mm nominal dia |
| 308 | 100 mm nominal dia |
| 309 | 150 mm dia |
| 310 | 200 mm dia |
| 311 | Providing, lowering, laying & jointing MDPE/ HDPE pipes (Class-PE 80) PN 12.5 composite pipes for extra length for house service connections as per drawing and specifications complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. |
| 312 | With HDPE pipe |
| 313 | 20 mm dia service pipe |
| 314 | 25 mm dia service pipe |
| 315 | 32 mm dia service pipe |
| 316 | Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches complete with all accessories like Bend, Tee, Reducer, Stub end, End cap etc including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. |
| 317 | 75 mm. OD. |
| 318 | 90 mm. OD. |
| 319 | 110 mm. OD. |
| 320 | RISING MAIN WATER SUPPLY |
| 321 | Construction of brick masonry valve chamber for different type of valves with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand), wall 230 mm thick, top cover slab 150mm thick RCC M20 grade (1:1½:3 i.e. 1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) with C.I. surface box with hinged cover 100x100x75mm (deep) including earthwork excavation, 100mm thick levelling course of PCC M10 (1:3:6 i.e. 1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Engineer. |
| 322 | 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve |
| 323 | Supply and fixing of Fire Exit Door of Size 2 mtr L*2.4 Mtr H With Frame and Push bar Double Door Type. Including all required nacessary fitting & fixtures as per direction of engineer incharge . |
| 324 | Supply and fixing of CURVED “SELF SUPPORTED” SECRET FIX STANDING ROOFING SYSTEM IN 0.9 mm THICK AA 3004 ALUMINIUM ALLOY. The general roof-construction shall comprise from bottom to top:1) First Layer Steel liner -28-32/200-250 Galvalume steel liner sheet (GSM 150) 550 MPa, 0.5 mm TCT 1000 mm total cover width 35mm deep ribs spanning up to 1300 mm centres (multiple spans). The finish to the exposed surface of the liner will be polyester coating with film thickness of 23um +/-2 um.2) Second Layer Top Hats & Brackets- Top hat & brackets as required 1.6mm & 2mm thick galvanised steel hat section respectively.3) Third Layer - Single layer of scrim reinforced polyethylene or Aluminium foil in 150 g/m2 water vapour resistance .The VCL shall be of 180-200 Microns thickness.4) Fourth Layer Insulation - One layer of Rockwool/Glasswool insulation of 100mm thickness each minimum 64 kg/m³ rockwool/24 Kg/m3 (glasswool)density with thermal conductivity of K=0.035 W/mk at 20 degrees Celsius when tested to ASTM C518.5) Fifth Layer - Halters - Aluminium Halters/- in grade 6082 (T6), of suitable height with thermal barrier pads to be fixed to the sub purlins with SS 304 screws only. |
| 325 | 6) Sixth Layer –Aluminum 65/400 Straight profile sheeting manufactured from aluminum self-supported standing seam roof system from aluminum alloy AA 3004 H44 (AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and PVDF2 finish (standard colors) on the exposed surface. The profiled roof panel should have 24nos. of Micro ribs of height 1.5mm in between 3Nos of Mini ribs for extra strength Accessories, Fasteners. The material properties shall be as follows: Ultimate tensile strength: minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, Modulus of elasticity: 70,000 N/mm2. Sheets are to be laid to meet the requirements of the building geometry and fixed on Aluminum Halters. Halters to be fixed to the top hat/purlins with SS 304 screws All installation is to be carried out by approved trained roofing installer. The roofing system provider should have both Factory Mutual (FM-4471) & UL Certification (UL-90). The Roofing system provider should have done testing for Water leakage ( Static & Dynamic ) and Air Infiltration test as per ASTM E 283-04,ASTM E330-02 (2010),ASTM E331-00, AAMA 501.1.05, AAMA 501.2-09 . All installation is to be carried out by approved trained roofing installer. The installation team shall be fully trained and approved by the supplier.Complete job in all respect as per approved design & drawing under approval of project consultant, appointed for the project & as per directions of Engineer-In-Charge. |
| 326 | Providing and Fixing of Multi cell Polycarbonate Panels 16mm thick with 5 cells - 6 walls structure over MS Supporting structures (paid separately). Panel Width shall be 600mm - 1040mm to ensure best performance for wind uplift. The panels shall be uniform in colour with an integral Microcell core with softlight/ Reflective finish to give diffused/optimum light. In a cross section, the core shall be constructed of microcells not exceeding 4mm x 4mm and shall be square/rectangular in appearance. Panels shall be coextruded with UV Protection layers having UV filtration of less than 0.1% as per UV filtration test AS No.1067-1990. The weight of the only panel shall not be less than 3250 gram per square meter. Panel shall have U value not more than 2.0 W/m2k (lower U Value would be preferred). Panel and system should pass impact and shock resistance tested for D1(Small Hardbody of 1KG Maas) -10j(Energy), M 50(Large Soft Body of 50KG Maas) -300J, (Energy), M 50 (Large Soft Body of 50KG Maas) - 400J (Energy). The panels shall have cold bending radius of minimum 3.2 meter. Panel should achieve minimum sound absorption level 19DB (Higher sound absorbtion would be preferred). Panel system shall have Vertical Standing Seam 15mm at both sides and snap-on connector to interlock the panels with a grip-lock 2 tooth locking mechanism to ensure maximum uplift capability. Panels shall be fixed on Purlins (paid separately) with special SS Expansion fastener with design load 5000 Newtons per expansion fastener and polycarbonate U/2 connectors. Panel system shall be sealed with additional Tape / End caps / Aluminium F and/or U Profile (mill finish) at the ends. Panel should pass through Sandbag impact test ASTM E 695-03 after 25,000 hours of environmental exposure and Hailstone impact test as per ASTM E 822-81. The panel system shall pass water penetration test ASTM E -331. The panel to have classification under B S1 D0 for reaction to fire as per test standard EN 13501 – 1:2002 tested by an independent, recognized testing laboratory. Panels shall have Yellowness Index as per ASTM D-1925; the change shall not be more that 10 points after 5 Years of exposure in comparison to original. The Colour of the panel shall change no more than 3 units as per ASTM D2244 after 5 Years of exposure in comparison to original. The Light Transmission of panels shall not change more than 10% after exposure of 5 years in comparison to original. The Panels shall be manufactured with approved quality assurance as per ISO 9001 & ISO 14001 and manufacturer should have successful project reference in Indian sub-continent at least 10 years old. Translucent polycarbonate system shall be manufactured by a company continuously and regularly employed in the manufacture of translucent systems using polycarbonate panel systems for a period of at least ten (10) years and the panels shall be warranted for ten (10) years. Complete job in all respect as per approved design & drawing under approval of project consultant, appointed for the project & as per directions of Engineer-In-Charge. |
| 327 | Following third party test certificates as per above specification to be submitted for approval to Engineer in Charge before supply of materials :1. UV Filtration Test, 2. U Value Test, 3. Impact & Shock Resistance Test, 4. Acoustic Performance Test , 5. Sand Bag Impact Test, 6. Hailstone Impact Test, 7. Water Penetration Test , 8. Reaction to Fire Test, 9. Yellowness Index Test, 10. Colour Change Test, 11. Light Transmission Test , 12 ISO 9001 & ISO 14001 |
| 328 | P/F Turbo Ventilators and Skylights - 3600 CFM Advance Turbo, Size 24\\", With 2X14 Ft. Skylights - 2MM thick Polycarbonate sheet |
| 329 | Supply and Installation of ROOF – PREFABRICATED INSULATED PPGL FACE PANEL: |
| 330 | Roof: Insulated sandwich panels for roof of total thickness mentioned below exclusive of crest height of top corrugation. Panel shall be made of 0.50mm (+/-0.04mm) thick pre coated metal sheet on both sides of rigid polyurethane insulation. The top external facing metal sheet shall have corrugated shape with crest. The trapezoidal shape crowns/crest height should not be less than 30mm. The pre-coated metal sheet shall be PPGL (Pre Painted Galvalume Sheet with AZ coating) sheet having SDP (Super Durable Polyester) colour coat of 18 micron (min). The bottom sheet must have tongue and groove type flange (U shape) of 8mm x 8mm on groove side and 8mm x 12mm on tongue side. Flange must be on lengthwise sides for joining adjacent panels. Panel's bottom side PPGL sheet must also be pre-strengthened by full lengthwise stiffening with semi-circular beading of 12mm width & 3 to 4mm depth at 240 (+/-5) mm pitch. The top corrugated sheet must have at-least one open crown/crest for overlapping adjacent panel widthwise. Similarly the top corrugated sheet must have suitable open extension of min 6” on bottom widthwise side of panel for overlapping further panels joined lengthwise also. The insulation core shall be self-extinguishing DIN 4102,Class B3 fire retardant class rigid PUR with thermal conductivity of 0.025 W/mK and with initial density of 40kg/m3 (+/-2kg) suitable for temperature range of -30 degree C to +80 degree C. The panel must be made using glue-free high pressure hot pressing self-bonding method. PPGL sheet on both sides of panel shall have a min15 micron protective plastic guard film to avoid scratches during transportation. |
| 331 | Thickness 105mm (+/- 2mm) |
| 332 | Providing and Fixing of Perforated MS Sheet of thickness 3mm with Powder coating of 80-100 microns including frame work, CNC Cutting, installation, fittings, Scaffolding Complete in all respect upto hight of 20 mtr as per dirction of engineer incharge. |
| 333 | Heritage elevation front porch (bansi pharpur stone |
| 334 | Providing and Fixing Dholpur White / Mandana stone/ Gwalior mint stone base with white cement & Tinex chamical, & SS Clamp and Fastners (of approved brand) inclusive of moulding, carving, rubbing, polishing complet, laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attached with hairline joint at transition including rubbing, polishing and finishing, complete in all respect as per direction of Enginner & Architect with all lead & lift. The Stone measurement will be done of outer most dimension. |
| 335 | Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10 m height with 20 to 30 mm thick Pink Sand stone (Bansi Paharpur) and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid separately) |
| 336 | Exposed face Machine cut |
| 337 | Providing and fixing Stone jali 50mm thick Red/Pink sand stone as per ornamental design to fixed with white cement/epoxy mortar including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade. |
| 338 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases in stone and holes in walls wherever required. |
| 339 | Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of. |
| 340 | Supplying and fixing machine cut dressed 75 mm Pink sand stone (Bansi Paharpur) dasa/ coping wth ornamental shape having moulding and \\"PAN Shape\\" engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. |
| 341 | Providing and fixing 12MM toughened glass and staking with spider SS fittings & Weather proofing of glass panels using weather proof silicon (Dow Corny 789) complete in all respect as per drawings attached (Drg-7), as per direction of Engineer-in-charge and Architect with all lead and lift |
| 342 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, as per the drawing attached (Drg 7) and complete in all respect as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately), with all lead & lift. |
| 343 | Providing and Fixing of Stone Chattris(Palki) of size (4X6X8 ) M in Bansipaharpur stone on 4 pillars of size 0.45M Dia. as per drawing including carving, cladding etc all including required DASA copings and all attached and fixing with SS clamps and fasterners with tenax chemical ,including Planning, developing, making base, carving work, polishing, all loading-unloading, transportation, scaffolding, hoisting, installation with all required T&P (including white cement, pigment, Chemical, SS clamps and fasteners of approved brand etc.), fixing over/on base/surface as per shape-size & placement of approved drawing , finishing, surface treatment etc. covering properly till the date of opening/inauguration of site etc. under the direction of engineer incharge and as per approval from Architect. |
| 344 | Providing and Fixing of Stone Chattris of size (1X1X1.5 ) M in Bansipaharpur stone on 4 pillars of size 0.45M Dia. as per drawing including carving, cladding etc all including required DASA copings and all attached and fixing with SS clamps and fasterners with tenax chemical ,including Planning, developing, making base, carving work, polishing, all loading-unloading, transportation, scaffolding, hoisting, installation with all required T&P (including white cement, pigment, Chemical, SS clamps and fasteners of approved brand etc.), fixing over/on base/surface as per shape-size & placement of approved drawing , finishing, surface treatment etc. covering properly till the date of opening/inauguration of site etc. under the direction of engineer incharge and as per approval from Architect |
| 345 | Providing and applying breathable, nonreactive, transparent, antifungal, UV resistant, alkaline stable, impregnable silane-siloxane or equivalent based water repellent coating on exposed absorbing substrate like stone surface/ concrete surface/ mineral painted surface / exposed brick surface / lime surface in two or more coats to give uniform finish surface in all heights, horizontal, inclined, vertical and on ceiling complete in all respect and making it complete waterproof as per direction of the Engineer-in charge |
| 346 | P & F lst quality WVC white sensor Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete make Kerovit/Jaquar/Cera or equivalent size 460x580x340 |
| 347 | P & F European syphonic white one pieces S trap 220/300 mm rough in with PP thin rim seat cover including concealed cistern body with installation kit 10 liter capacityglazed vitreous china 1st quality including cutting and making good the wall and floor make Kerovit/Jaquar/Cera or equivalent size 520x360x360 |
| 348 | P & F WVC wash basin white under counter 1st quality of approved make Kerovit/Jaquar/Cera or equivalent with C.I. brackets duly painted, 32 mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall.: with all accessories size 540x420x150 |
| 349 | Providing and fixing Superior quality (Jaguar, kerovit, cera Contiental or equivalent) CP Brass fittings complete as per direction of EI, Pillar Cock with auto closing system 15 mm nominal size I all accessoroies |
| 350 | Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.: All kinds of soil |
| 351 | Pipes cables, etc. exceeding 80mm dia but not exceeding 300mm dia. |
| 352 | SMARTFLOW HAND DRYER WHITE OF ABS MATERIAL |
| 353 | Providing and fixing of UPVC casement fully (french) open-able windows (outward / inward) : Frame made from the Extruded UPVC Windows profile section of size 60w X 60h mm having outer wall thickness of 2.5 mm (+/- 0.2mm) and 3 box multi-chamber constuction, White in finish, duly reinforced with 1.5 mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 60w X 80h mm UPVC profile section with steel reinforcement shall be provided for the fix portion of the window and for the window area having 2 or more openable shutters / fix part as per the requirement. Frame shall have co-extruded EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. |
| 354 | Shutter: The shutter of outward openable window shall be made of size 60w X 74h mm and shutter of inward openable window shall be made of size 60w X 77h mm Extruded 3 box multi-chamber UPVC Window profile section of white colour having outer wall thickness of 2.5 mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners. shutter as well as fix part of the window shall be fitted with UPVC glazing bead of size 36 X 20 mm with inner and outer co-extruded EPDM/TPE-E Gasket. |
| 355 | Supplying and laying of 150 gsm Geotextile to cover the walls and base of drainage trenches with sufficient overlapping as per the direction of the engineer in charge. |
| 356 | Supply and laying of crushed stone chips, sharp and angular graded of size 6 to 12mm graded etc. Complete with a lead of 10km. |
| 357 | Supplying and laying of 100mm uPVC single wall Corrugated Perforated Pipe (As per ASIM, DIN & IS 9271:2004) for lateral subsurface drainage lines including all fittings ( as per IS:7834 / IS: 10124) and fixing using single and double ‘ Y’ joints and maintaining a spacing of 5 metres at one side of the main pipe preferably keeping uniform spacing for all alternate joints on the other sides of the main pipes and as per the direction of the engineer in charge. |
| 358 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. |
| 359 | 160 mm dia |
| 360 | Supplying and laying approved quality USGA Standard river sand at an uniformly compacted layer . Particles Size Distrbution of Root Zone Mix Sand should be as below:- Fine Gravel & Very Coarse Sand- 1.0-3.4mm Not more than 10% of the total particles in this range, Including a maximum of 3% fine gravel. Coarse sand & Medium Sand -0.25-1.0 mm- Minimum of 60% of the Particles must fall in this Range Fine Sand - 0.15-0.25 mm- Not more than 20% of the Particles may fall within this range Very Fine Sand & Silt - 0.002-0.15 mm - Not more than 5% Clay- Less than 0.002 mm - Not more than 3% |
| 361 | Supply of dry manure including loading unloading,transportation & stacking at site. |
| 362 | Neemcack |
| 363 | Supplying and laying Bermuda tifway 419 grass, cleaned to remove soil from the roots, washed with fungicides, from any approved source under monitoring of the curator in charge, Sprigging or dibbling Bermuda Tifway 419 variety grass in the outfield not more than 25 mm apart, thereafter continued monitoring and maintaining pest and disease free healthy turf growth, maintaining good color and texture, constant de-weeding , mowing, frequent top dressing with sieved sand to maintain the desired gradient the top surface with a minimum maintenance period of 75 days or till the grass becomes dense. |
| 364 | Supplying Black Cotton soil from local soil (Haryana/ Rajasthan border ) from a source approved by a BCCI certified curator. |
| 365 | Drying, breaking and sieving Black soil at 12 mm down size, second sieving at 4 mm down size at third sieving at 2 mm above size, separating 4 to 12 mm, 2 to 4 mm aggregates and 2 mm down size, properly stored in a dry place protected from rain and irrigation water and surface moisture. The work should be carried out as per direction of the curator in charge. |
| 366 | Excavation of earth measuring 30.48 m x 21.35 m x 0.25 m at the main ground for cricket pitch construction, dressing, neatly finishing the base following the desired gradient, fixing plywood of 400 mm height surrounding the pitch squares, laying 150 gsm geotextile in between pitch squares and the outfield as per direction of the engineer in charge. |
| 367 | Construction of two layer cricket pitches of 30.48 x 3.05 m x 250 mm sizes, maintaining 1% slope at the base from west side towards east direction, consisting a compacted and neatly finished drainage layer of 100 mm river sand and 250 mm ( dry) Black soil as supplied and sieved to 4 to 12 mm and finished at the final layer, laid in layers not exceeding 75 mm each, compacted in dry conditions with vibratory plate compactor, lightly scarified before adding next layers, neatly finished at the top maintaining 1% slope from west side towards east direction. (Direction of slope as per site) |
| 368 | Supplying and Dibbling Bermuda selection one grass sprigs 25 mm apart at 45 degree angle, free of roots, soil and leaves, washed with fungicides at the dry final surface of the pitch without creating any depressions or disturbing the surface level. Drenching Nuturf Folimax 0-22-42 immediately after dibbling and thereafter maintaining the pitch square for a minimum period of 3 months preferably Nuturf Folimax or equivalent standard imported turf grade liquid fertilisers and micronutrients with low salt index as approved by the curator in charge. Broadcasting any type of organic fertiliser or granular, water soluble fertilisers with high salt index will not be used. |
| 369 | Providing, fabricating, assembling and erection of pre stressed Special Architectural structure/membrane roofing structure of Tensile fabric TX – 30, Type - III fabric for opaque and translucent of 1050 GSM precontraint PVDF coated fabric from Serge Ferrari or equivalent brands. The membrane should confirm to the manufacturing standard of being pre stretched in both warp and weft direction during manufacturing to perform best dynamic stability in both wrap and weft direction with approved installers and Manufacturer for Architectural Roofing ,(Construction Catalysers/Ancon India/GrorichHorivert etc.) The fabric must be of HT polyester cables yarns 1100 Dtex coated with uniform 230 micron PVC coating over the polyester yarn. The surface coating ( top/back) cross link PVDF/PVDF Coated, Includes self – cleaning, anti-uv, anti-static,anti-mildew and excellent weathering resistance properties. |
| 370 | The dimensional stability of the fabric should be measured as per elongation test of 24h -10daN/5cm which should confirm <1%-<1% (EN 15977) and residual elongation should confirm <0.4%-<0.4% (EN 15977) ensuring dimensional stability in both warp and weft direction, coated fabric weight should be 1050 gsm ,Tensile strength of 5600 N/ 5 cm in Warp direction and 5600 N/ 5 cm in in weft direction and tear strength of wrap/weft direction800 / 650 N and with a Guarantee of 25yrs (with non depreciating guarantee for first three years) from the manufacturer, width of the fabric should be 178cm, Adhesion 120 N/5cm . Flame retardancy Bs2d0 -EN 1350-1, Quality in conformity with ISO 9001 with 25 years warranty from manufacturer. |
| 371 | The Membrane fabrication should confirm to standards of desired profile as per approved shop drawing including necessary designing with non-linear design software, seaming machine at least capacity from 20 kv to 25kv not including travelers seaming machine, CNC plotter & cutter machine for cutting of membrane pattern, swage end machine upto 30mm dia cables etc. The welding should be using High Frequency welding machine of minimum welding seam width with 50 mm. This work shall include CHS members of YST 310 Mpa, plates - YST 245 MPa, anchor bolt , nut and washer are to be HDG Gr.8.8, structure steel cables should be with class A HDG wire rope with minimum tensile strength of 1570 MPa and single construction, swagged cable end connectors. |
| 372 | All fabricated steel members should be zinc primer (DFT 50 microns minimum), top coat of HB epoxy paint (DFT 100 microns), top PU to coat (DFT 50 microns), over steel structure frames with all fittings and fixtures such as Stainless steel End Plate ,Shackles, Rigging Screws , Turnbuckles, swedge, fork, keder rods & galvanized MS strands with stainless steel end terminals asper Drawing / Detail & as per particular/ technical specifications and as per the directions of Engineer-in-charge and the submitted approved drawing. |
| 373 | The contactor shall provide original warranty certificate issued by his company with manufacturer warranty. Actual surface area of canopy end to end shall only be measured in square meter correct up to two decimal places. |
| 374 | (Rate includes cost of fabric, fabrication, laser / CNC, cutting of plates and pipes,sand blasting , epoxy coating. PU coating ,erection of steel structure (for Canopy Only), supply of fabric, accessories, cables, aluminium profiles, total station survey of structure, cutting pattern generation, plotting cutting, welding, packing, transportation, installation of fabric, etc . Tensile strength of 5600 N/ 5 cm in Warp direction and 5600 N/ 5 cm in in weft direction with 25 year diminishing warranty.complete in all respect as per direction of Engineer-In-Charge) |
| 375 | Cleaning of external surface of MS pipe with sand blasting and or abrasive blasting at factory/ site complete |
| 376 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 377 | Providing and applying P.U. paint of apporved brand and manufature to even shade. Two or more coats on New works. |
| 378 | Spray painting in approved shade and approved quality with Duco paint of required colour to give even shade with two or more coats by compressor including sand papering, NC putty filler coat etc complete in all respect as per design given by Engineeer incharge on new work. |
| 379 | Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversioncomplete.[MoRTH specification : Clause 401]. By mechanical means. For Grading-III Material |
| 380 | Dry Lean Cement ConcreteConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing. |
| 381 | Construction of un-reinforced , plain cement concrete pavement M30 (Grade), thickness as per design, over a prepared sub base, with 43/53 grade cement as per Clause 602.2.2 , coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design including pumping of R.M.C. from transit mixer to site of laying , with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using Fixed Form Paver and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days using water finishing to lines and grade as per drawing and MoRTH Specification Clause 602 including vaccum dewatering process with all required equipments (Dowel Bars will be paid seprately). |
| 382 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 383 | Mumtis D |
| 384 | Add extra for double leaf shutters. |
| 385 | Providing and fixing of Perforated Metal Tile Ceiling System comprising of Tile of 600mm wide and 600mm long manufactured out of 0.5mm thick Galvanised Iron with beveled edge of 4.15mm width height of 32mm. The tiles shall be perforated to 1.5mm dia with open area of 23%. The Tile will be manufactured on advanced equipment that includes several leveling stages in the manufacturing process by approved manufacturers. Tile ends will be raised with pips and slops to ensure positive engagement into the spring to enable for de-mounting of individual panels. The Tile sides will be sufficiently high to ensure a minimum deflection across the length of Tile. All Tiles will be bevel edged. The Tile shall be epoxy polyester powder coating in white colour. The Tile shall be cllpped into clip in rail of 0.5mm thick GI. in form of a grid system using a cross connector. The clip in rail shall be supported from slab by means of rigid Suspension of 4mm G .I rod, Hold on Clamp with Clip. POWDER COATING SPECIFICATION: Aluminium PANELS, cleaned through eco friendly cleaning ,process and powder applied thru electrostatic charged Automatic Carona technology spray guns and cured in combination of Infrared & hot air oven in a certified plant as Akzo International approved applicator . |
| 386 | The powder is conforming with the performance requirements of the AAMA2603.02 & Qualicoat Claa 1 specifications. The coating thickness will be minimum 60 microns with properties of Salt Spray of 1500 hrs in exposure in SST Cabinet with Minimum blister rating 8. (Tensile strength of suspension-344/413 mpa and fastner strength-110kg) All Ceiling Panels shall adhere to GreenPro Certifications. |
| 387 | Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : |
| 388 | 12 mm thick one side laminated board Practical board (Phenol bonded) |
| 389 | Laying of Selection No.1 grass tiles (2’X2’ size) for development of garden, including levelling of soil and spreading of manure |
| 390 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. |
| 391 | 1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 392 | Swimming Pool Accessories |
| 393 | Supply & Fixing of TOTALLY ANTI-CORROSIVE Bobbin Wound filter, 2000mm diameter. Fitted with pressure gauge panel manual air bleeder, water drain and emptying plug. fitted with collector arms and diffuser made from unplasticized PVC and polypropelene with all accessories required. Filtration velocity 40m³/hr/m². Max. working pressure : 2.5 kg/cm². Flow rate: 125m³/hr , outlet size 140mm, Height : 2040mm. Make Astral pool , Hayward , Zodiac . |
| 394 | Supply & Fixing of Valve Battery Manifold made in PVC with flanges for connecting to filters as per DIN 2501 standards. Consists of set of 5 - buttterfly valves for carrying out filtration, back-washing, rinsing and shut down of the filters. Size : 140mm . Make Astral pool , Hayward , Zodiac . |
| 395 | Supply & Fixing of Valve battery supports made in Zinc Plated Steel. Height : 2.30m. Complete in all respect and as per dirction of Engineer-in-charge. |
| 396 | Supply & Fixing of Support Brackets : 2 Support Brackets with anti-vortex clamps and fixing screws For Ø 140 mm pipe. Complete in all respect and as per dirction of Engineer-in-charge. |
| 397 | Supply, Installation, Testing and Commisioning of ActiveClear Glass Media which should have Efficient and environmentally friendly filtration, Greater filtration capacity, Water and energy savings & Clean filter bed as bacteria does not remain trapped and fewer chemical products are needed.Grade 1. Size 0.5 mm - 1.0 mm. (bag of 25 kgs) |
| 398 | Supply, Installation, Testing and Commisioning of ActiveClear Glass Media which should have Efficient and environmentally friendly filtration, Greater filtration capacity, Water and energy savings & Clean filter bed as bacteria does not remain trapped and fewer chemical products are needed.Grade 2. Size 1.0 mm - 3.0 mm. (bag of 25 kgs) |
| 399 | Supply, Installation, Testing and Commisioning of ActiveClear Glass Media which should have Efficient and environmentally friendly filtration, Greater filtration capacity, Water and energy savings & Clean filter bed as bacteria does not remain trapped and fewer chemical products are needed.Grade 3. Size 3.0 mm - 7.0 mm. (bag of 25 kgs) |
| 400 | Supply & Fixing of Cast Iron Pumps 3000 r.p.m. Mechanical Seal in Stainless Steel. I.P.-54 motor protection. Stainless steel shaft. stainless steel strainer basket. Conn. PN-16 according to DIN2501. Flowrate : 125m3/h @ 12m.head. 10 HP Voltage 400V/ 3 ph. Pump housing and Impeller in cast Iron. Make Astral pool , Hayward , Zodiac . |
| 401 | Supply & Fixing of dosing pumps with constant flow rate manually adjustable by a knob mounted on the front panel.The flow rate has two frequency ranges: 0-20 % of max flow rate, 0-100% of max flow rate 32 l/h for Pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 402 | Supply & Fixing of Semi transparent polyethelene tank with external scale so that levels can be checked easily, capacity of tank 500lts. Complete in all respect and as per dirction of Engineer-in-charge. |
| 403 | Supply & Fixing of Agitators for easy installation in the tanks, provided with steering grip in bakelite, rod and propellor arms in PVC, length of stirring rod 900mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 404 | Supply & Fixing of White ABS plastic bottom inlet for concrete with S.S. screws. and regulable flow. Max. Flow/ inlet of 9,000l/hr for pool inlet. Complete in all respect and as per dirction of Engineer-in-charge. |
| 405 | Supply & Fixing of Drain grille in SS 304. 500mm x 500mm Flow: 136m3/hr for Pool Drain. Complete in all respect and as per dirction of Engineer-in-charge. |
| 406 | Supply & Fixing of 200 drain grille in ABS. Ring support and grille in white ABS. Supplied with grille fixing screws for Pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 407 | Supply & Fixing of Overflow 1000 model. Ladder width 500 mm Ø 43 mm handrail, non-slip surface stainless treads, bright satin finish, anchoring fixtures for connection to the equipotential circuit and removable anchoring with plate for fastening to wall. AISI-316 handrail and steps. 4 steps for Pool |
| 408 | Supply & Fixing of Overflow 1000 model. Ladder width 500 mm Ø 43 mm handrail, non-slip surface stainless treads, bright satin finish, anchoring fixtures for connection to the equipotential circuit and removable anchoring with plate for fastening to wall. AISI-316 handrail and steps. 3 steps for Pool |
| 409 | Supply & Fixing of Underwater LED Warm White LumiPlus Flexi spotlightLight 32 W/12V AC. 4320lm with White Faceplate. Complete in all respect and as per dirction of Engineer-in-charge. |
| 410 | Supply & Fixing of Standard Niche for Pool lighting. Complete in all respect and as per dirction of Engineer-in-charge. |
| 411 | Supply & Fixing of Junction Boxes, made in ABS, composed of 3 entries. 3/4\\" or PG-16 coupling for Pool lighting. Complete in all respect and as per dirction of Engineer-in-charge. |
| 412 | Supply & Fixing of Cable Conduit Hose, Flexible 1 mt. long conduit for conn. light to junction box. 3/4\\" and PG-16 threaded ends for Pool lighting. Complete in all respect and as per dirction of Engineer-in-charge. |
| 413 | Supply & Fixing of Transformer 300 W/12V with protection box for pool. Complete in all respect and as per dirction of Engineer-in-charge. Complete in all respect and as per dirction of Engineer-in-charge. |
| 414 | Supply & Fixing of Overflow Grating Tile 300mm for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 415 | Supply & Fixing of grating Support profile Made in plastic. Suitable for 35mm high grating, Supplied in 2 m length. Complete in all respect and as per dirction of Engineer-in-charge. |
| 416 | Supply & Fixing of 90° corner tiles for overflow channels made of white, injection moulded copolymer polypropylene. Height 22 mm, channel width 295 mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 417 | Supply & Fixing of Pump caddy for stand-alone pool cleaners. Made of anodized aluminium tube and a 460 mm x 370 mm plastic platform. Face plate in AISI-304 stainless steel. Starter and cable. Complete in all respect and as per dirction of Engineer-in-charge.Make Astral pool , Hayward , Zodiac . |
| 418 | Supply & Fixing of Victoria Monoblock Pump - 3 HP / Single phase. Pump. body and support in heat resistant plastic. Shaft with Noryl Impeller. Large capacity strainer for cleaning of pool. Complete in all respect and as per dirction of Engineer-in-charge. Make Astral pool , Hayward , Zodiac . |
| 419 | Supply & Fixing of aluminium pool cleaner - 1000mm length. 2\\" connection. Trailing cable 110m Complete in all respect and as per dirction of Engineer-in-charge. Make Astral pool , Hayward , Zodiac . |
| 420 | Supply & Fixing of Extensible handles for cleaning attachments in anodized aluminium which can be adapted to the entire range of cleaning equipment, brushes, leaf skimmers and scoops.10.0mts. Long with Handle adaptor for cleaning of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 421 | Supply & Fixing of Floating suction hose Made of blue polyethylene. Ø 50 mm (2”) 30 m for cleaning of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 422 | Supply & Fixing of Shark leaf skimmers - wing-nut or wishbone fixing. Shark deep water leaf skimmer forcleaning of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 423 | Supply & Fixing of Shark leaf skimmers - wing-nut or wishbone fixing. Shark surface leaf skimmer for cleaning of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 424 | Supply & Fixing of Shark brushes - wing-nut or wishbone fixing. Shark special bottom curved brush for cleaning of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 425 | Supply & Fixing of Shark brushes - wing-nut or wishbone fixing. Shark bottom/walls curved brus for cleaning of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 426 | Supply & Fixing of Classic brushes - wing-nut fastening. S.S. bristle 165 mm for cleaning of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 427 | Supply & Fixing of Free chlorine and pH Pooltester. Chlorine range: 0.5–6.0 mg/l & ph range: 6.8–8.2 for Pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 428 | Supply & Fixing of valves, shall be in PVC with PN10 rating and EPDM seat.Ball Valve single union dia 50mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 429 | Supply & Fixing of valves, shall be in PVC with PN10 rating and EPDM seat.Ball Valve single union dia 63mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 430 | Supply & Fixing of valves, shall be in PVC with PN10 rating and EPDM seat.Wafer type check valve 150mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 431 | Supply & Fixing of valves, shall be in PVC with PN10 rating and EPDM seat.Butterfly Valve with Flange Adapters dia 150mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 432 | Supply & Fixing of valves, shall be in PVC with PN10 rating and EPDM seat.Expansion Bellows dia 160mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 433 | Supply & Fixing of Bobbin Wound Filter Dia 600mm with Clamp Lid, 1.5\\" SideConnection. Flow Rate: 14m3/hr, Filtration Velocity: 50 m³/h/m²) Max Pressure: 2.5 bar. Totally Anti- Corrosive polyester+Fiber glass filter with Clamp Lid. Fitted with pressure gauge panel, manual air bleeder, water drain & emptying plug. fitted with collected arms and diffuser made unplasticized PVC & Polypropelene. Make Astral pool , Hayward , Zodiac . |
| 434 | Supply & Fixing of Multiport Valve 1.5\\"-Manual multiport valves with six channels to carry out different functions in an hydraulic circuit. Its design, basically functional, offers a wide range of possibilities of connection to any installation, assuring perfect water-tightness and comfortable handling. |
| 435 | Supply & Fixing of union fitting 1.5\\" for Equipment of Pool filtration. Complete in all respect and as per dirction of Engineer-in-charge. |
| 436 | Providing & Fixing of Victoria Silent Monoblock Pump 1HP - S. Phase 16,000 l/h / 230V II Low noise level: between 61 dB and 70 dB Pump body and support in heat resistant plastic. Double protected shaft with IP-55 protection. Large capacity strainer. Noryl Impeller. Complete in all respect and as per dirction of Engineer-in-charge. |
| 437 | Supply & Fixing of dosing pump Adjustable Optima manual pump at 8 bar and 5 l/h for Pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 438 | Supply & Fixing of Semi transparent polyethelene tank with external scale so that levels can be checked easily, capacity of tank 100lts. Complete in all respect and as per dirction of Engineer-in-charge. |
| 439 | Supply & Fixing of Agitators for easy installation in the tanks, provided with steering grip in bakelite, rod and propellor arms in PVC, length of stirring rod 600mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 440 | Supply & Fixing of Wall Inlets 50mm Outer 2\\" thread and Ø 50 mm inner wall to be glued for Pool Inlet Made of ABS. Flow rate 4.5 m3/hr. Complete in all respect and as per dirction of Engineer-in-charge. |
| 441 | Supply & Fixing of Round Main Antivortex Drain 2\\" Body & Grill in ABS Grill Fitted using screws for Pool Drains Max Flow rate: 13m3/h. Complete in all respect and as per dirction of Engineer-in-charge. |
| 442 | Supply & Fixing of Skimmer Square Lid 15 Ltrs Made of ABS, they come with a weir flap and a flow regulator check valve. Bottom suction nozzle connection: 11/2\\" inner thread, 2\\" outer thread. Simultaneous connection to the main drain: Ø 50 mm inner wall. Overflow connection: Ø 40 mm. Leaf trap. Recommended flow rate: 5 m3/h. |
| 443 | Supply & Fixing of Overflow 1000 model. Ladder width 500 mm Ø 43 mm handrail, non-slip surface stainless treads, bright satin finish, anchoring fixtures for connection to the equipotential circuit and removable anchoring with plate for fastening to wall. AISI-316 handrail and steps. 2 steps |
| 444 | Supply & Fixing of Underwater LED Warm White LumiPlus Flexi spotlightLight 14.5 W/12V AC for Pool lighting. Complete in all respect and as per dirction of Engineer-in-charge. |
| 445 | Supply & Fixing of Transformer 100 W/12V with protection box for Pool lighting. Complete in all respect and as per dirction of Engineer-in-charge. |
| 446 | Supply & Fixing of valves, shall be in PVC with PN10 rating and EPDM seat. Double union check valve 50mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 447 | Supply & Fixing of valves, shall be in PVC with PN10 rating and EPDM seat. Double union check valve 63mm. Complete in all respect and as per dirction of Engineer-in-charge. |
| 448 | Supply & Fixing with anchoring fixture of Starting Block for Pool which should be Specially designed for competition events. Available with adjustable footrest to facilitate entry into the water. Its minimalist design in high quality materials gives it an elegant and modern look. Manufactured in AISI-316 stainless steel. Polished surface finish. Adjustable support (6 positions) Complete in all respect, Dimension as per fina standard and as per dirction of EIC. Make Astral pool , Hayward , Zodiac . |
| 449 | Supply & Fixing of Lane Rope comprising lane ropes with an external Ø of 148 mm in accordance with FINA international swimming federation regulation FR 3 for pools for Olympic Games or world championships. Supplied assembled with floats, 6 mm stainless steel rope. - 50m. Complete in all respect and as per dirction of Engineer-in-charge. Make Astral pool , Hayward , Zodiac . |
| 450 | Supply & Fixing of Float Line anchors made in S.S.-316 for Float Lanes of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 451 | Supply & Fixing of Float Line Flange anchoring Socket made in S.S.-316 for Float Lanes of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 452 | Supply & Fixing of Lane Tensioner in Chrome plated brass for Float Lanes of pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 453 | Supply & Fixing of Float Line Roller Made of S.S.-304. Mounted on 4 rotating wheels for maximum mobility and transport. 1.2m width for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 454 | Supply & Fixing of 'False start indicators comprise of 2 posts in S.S-316 Height : 1.8m for Pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 455 | Supply & Fixing of False start floats includes polyester cord and float 25m. Complete in all respect and as per dirction of Engineer-in-charge. |
| 456 | Supply & Fixing of Backstroke turn indicators comprise of 4 posts in S.S-316 for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 457 | Supply & Fixing of Backstroke turn indicator bunting. 2 polyester cord and bunting 25 m for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 458 | Supply & Fixing of Level anchor fixing in S.S.-316 for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 459 | Supply & Fixing of Life Buoys. made of Styropor covered with orange canvas, Ø 700 mm for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 460 | Supply & Fixing of Lifebuoy hook made of AISI-316 stainless steel with connection to telescopic handles for pool. Complete in all respect and as per dirction of Engineer-in-charge. Make Astral pool , Hayward , Zodiac . |
| 461 | Supply & Fixing of Reinforced telescopic pole, aluminium.10.0mts. Long for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 462 | Supply & Fixing of Made in Stainless Steel AISI-304. With dismountable base plate. Steps, Platform, chair, including parasol holder made of polypropylene fibre-glass.Wheeled base for lifeguard chair. Complete in all respect and as per dirction of Engineer-in-charge. Make Astral pool , Hayward , Zodiac . |
| 463 | Supply & Fixing of Outdoor heatpump with Full inverter technology, equipped with high-quality Inverter DC Panasonic compressor and DC fan motor, the unit's COP is up to 16.1 and EER reach to 5.3. Particularly, the unit have 2 displays for option. Both the displays provide a one-key boost button, users can maximize the running capacity, so as to achieve the ideal heating or cooling result in a shorter time. 300kW output in Booster mode and 250kW output in smart mode.Above heat pump functions, subject to conditions mentioned below :(1) Cease to operate at 10°C ambient temperature(2) Installed outdoor(3) Max Pool Temperature : 28°C(4) Initial Heating time required shall be 48 hours Make Astral pool , Hayward , Zodiac . |
| 464 | Supply & Fixing of Butterfly valve of 110mm Dia. Complete in all respect and as per dirction of Engineer-in-charge. |
| 465 | Supply & Fixing of flange of 110mm Dia. Complete in all respect and as per dirction of Engineer-in-charge. |
| 466 | Supply & Fixing of flange Adapter of 110mm Dia. Complete in all respect and as per dirction of Engineer-in-charge. |
| 467 | Supply & Fixing of Thermal Pool Cover, Blue Deluxe, Bubble Type, 400 micron, Std Model. Complete in all respect and as per dirction of Engineer-in-charge. |
| 468 | Supply & Fixing of Roller Shaft in Aluminium Telescopic 5-6.6m for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 469 | Supply & Fixing of Roller Support - 2 mobile supports. Contains of 2 Stainless Steel AISI-304 structures with wheels (1 set with brakes) to move the roller. Includes 8 straps per roller for pool. Complete in all respect and as per dirction of Engineer-in-charge. |
| 470 | SITC of Control panel for controlling pumps, lights. Body shall be powder coated sheet metal cabinet for indoor installation, wall mounted, dust proof and shall be with hinged doors with rubber gasket. Panel shall read and display pump status, light status, voltage, current. Panel shall come with single phase prevention, phase reversal protection. Complete in all respect and as per dirction of Engineer-in-charge. |
| 471 | Supply & Fixing of uPVC pipe 10 kg/sqcm approved quality /make including joining the pipe with solvent cement rubber ring and lubricant with fittings where required e.g. tees, bends, etc. Complete in all respect and as per dirction of Engineer-in-charge. Make : Supreme, Finolex or equivalent50mm dia pipe |
| 472 | Supply & Fixing of uPVC pipe 10 kg/sqcm approved quality /make including joining the pipe with solvent cement rubber ring and lubricant with fittings where required e.g. tees, bends, etc. Complete in all respect and as per dirction of Engineer-in-charge. Make : Supreme, Finolex or equivalent63mm dia pipe |
| 473 | Supply & Fixing of uPVC pipe 10 kg/sqcm approved quality /make including joining the pipe with solvent cement rubber ring and lubricant with fittings where required e.g. tees, bends, etc. Complete in all respect and as per dirction of Engineer-in-charge. Make : Supreme, Finolex or equivalent90mm dia pipe |
| 474 | Supply & Fixing of uPVC pipe 10 kg/sqcm approved quality /make including joining the pipe with solvent cement rubber ring and lubricant with fittings where required e.g. tees, bends, etc. Complete in all respect and as per dirction of Engineer-in-charge. Make : Supreme, Finolex or equivalent 110mm dia pipe |
| 475 | Supply & Fixing of uPVC pipe 10 kg/sqcm approved quality /make including joining the pipe with solvent cement rubber ring and lubricant with fittings where required e.g. tees, bends, etc. Complete in all respect and as per dirction of Engineer-in-charge. Make : Supreme, Finolex or equivalent. 160mm dia pipe |
| 476 | Supply & Fixing of uPVC pipe 10 kg/sqcm approved quality /make including joining the pipe with solvent cement rubber ring and lubricant with fittings where required e.g. tees, bends, etc. Complete in all respect and as per dirction of Engineer-in-charge. Make : Supreme, Finolex or equivalent200mm dia pipe |
| 477 | Providing and Fixing of MS Sheet Personal Locker Almira with Door made of minimum 0.80 thickness and Body , Back and Shelves made of minimum 0.60 thickness with Powder coating with Minimum Locker size 0.30 x 0.30 x 0.40 m including installation, fittings Complete in all respect as per dirction of engineer incharge. |
| 478 | Practice Pitch |
| 479 | Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. |
| 480 | Good soil of earth |
| 481 | Supply of dry manure including loading unloading,transportation & stacking at site. |
| 482 | Farm yard manure(organic) |
| 483 | Supply of Chemical Fertilizers at store in bags weighing not less than 50 kg each including loading unloading & transportation |
| 484 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : |
| 485 | Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 486 | Providing & making artistic/heritage painting with the using oil paint/apex ultima or equivalent exterior paint having anti algal and dust pick up resistance with finish as per direction of Engineer in charge on wall faces/panels etc. with approved colour in following patterns including painting base works of required exterior paint in approved quality/brand:- |
| 487 | The Painting will be based on theme that is to made available by engineer in charge. As the work shall be at the level of similar to enclosed drawing “D”. |
| 488 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision |
| 489 | New Work |
| 490 | Providing and applying superior quality emulsion for wall painting with Velvet touch/Royal paint etc of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of Engineer-in-charge. |
| 491 | New Work Three or More coat |
| 492 | Providing and Laying of Interlocking M-30 grade Concrete Block Pavements having thickness 80 mm as per drawings and as per IS 15658:2006.and all materials shall conform to MoRTH Specification Clause 602 with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks. |
| 493 | Category 'B' : Dentated only two side like I,Z,T shape as per IRC:SP:63-2004 |
| 494 | Add extra for different colour in top surface |
| 495 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). |
| 496 | Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. |
| 497 | 50mm x 50mm x 3.15mm |
| 498 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 499 | M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 500 | Providing, fixing & Installation of Spectator Chairs in wall with Blow Molded Bucket, HDPE Material , Aluminium Pressure Die Cast Frame , Wall Mounted Stands , Powder Coated Frames , Water Drainage Facility , UV Protected Shells , Installation with M10x75mm Anchor Fastners Shell Size :- 450mm(W) x 520mm(D) x 390mm (H) |
| 501 | Providing, fixing & Installation of Spectator Chairs in wall with HDPE Blow Molded Seat , Seat Auto Tip Up , Common Armrest , Aluminium Pressure Die Cast Frame , Wall Mounted Stands , Powder Coated Frames , Water Drainage Facility , UV Protected Shells , Installation with M10x75mm Anchor Fastners , Shell Size (Back) :- 450mm(W) x 490mm(D), Shell Size (seat) :- 450mm(W) x 410mm(D) |
| 502 | Earth work for Sewer line and Manhole in excavation in foundation, trenches manholes, road side chambers etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level including allowances for any additional excavation beyond the drawings (measurement for payment to be as per standard drawings), re-handling of material/earth to complete the task. |
| 503 | In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. |
| 504 | Depth upto 1.5 m |
| 505 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 506 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 507 | With bricks with class designation 75 |
| 508 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) |
| 509 | With bricks class designation 75 |
| 510 | Extra for depth for manholes: |
| 511 | size 90 X 80 cm |
| 512 | With bricks class designation 75 |
| 513 | size 120 X 90 cm |
| 514 | With bricks class designation 75 |
| 515 | Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 516 | 100x100 mm size P type |
| 517 | With bricks class designation 75 |
| 518 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : |
| 519 | With bricks |
| 520 | Providing, fixing and constructing of pre-cast RCC M-40 grade circular manholes with internal dia 1.0m and up to specified depth having pre-cast RCC M-40 grade circular manhole cover frame (ID 0.56m, OD 0.92m), conical piece (top ID 0.56m, bottom ID 1.0m, vertical height 0.805m, wall thickness 125mm), and circular rings of required heights (ID 1.0m, height 150/225/300/600 mm, wall thickness 125mm) below conical piece as per required depth of manhole and having steel reinforcement in conical piece @ not less than 80 kg per cum of concrete, including cast-in-situ PCC M-10 grade (1:3:6) foundation of 1.625m dia and 150mm thickness, PCC M15 grade circular wall ID 0.925m, wall thickness 200mm, height equal to ID of sewer pipe + one wall thickness of pipe + 50 mm (to flush the manhole frame with road top, height of wall can be increased but not more than 100mm), PCC M15 grade benching and channel portion and up to top level of sewer pipe etc complete with curing compaction and form work, supplying and fixing heavy duty SFRC manhole cover as per IS 12592 (Part I and II), supplying and fixing plastic encapsulated CI/MS foot steps / SFRC foot steps, including cost of shuttering, steel reinforcement, testing for water tightness etc. complete in all respect as per drawing, as per specification and the direction of the Engineer. Note:- Excavation of earth work and road cutting for manhole will be measured and paid separately. |
| 521 | Pre-cast RCC M-40 grade circular manhole conical piece with inbuilt cover and frame (height 0.805), cast-in-situ PCC M-10 grade foundation, PCC M15 grade circular wall ID 0.925m, wall thickness 200mm, wall height equal to ID of sewer pipe + one wall thickness of pipe + 50 mm, PCC M15 grade benching and channel portion. Depth of manhole shall be measured from top of manhole cover upto lowest invert of pipe. (Depth includes in the item = height of Conical piece + ID of Sewer pipe + 1 Wall thickness of pipe + 50mm) |
| 522 | Providing and fixing pre-cast RCC M-40 grade circular ring of ID 1.0m, wall thickness 125mm, height 150/225/300/600 mm for constructing extra depth of manhole beyond depth mentioned in item no-17.59.1 as per drawing. |
| 523 | Providing, fixing and constructing of pre-cast RCC M-40 grade circular manholes with internal dia 1.5m and up to specified depth having pre-cast RCC M-40 grade circular manhole cover frame (ID 0.56m, OD 0.92m), conical piece (top ID 0.56m, bottom ID 1.5m, vertical height 1.305m, wall thickness 125mm), and circular rings of required heights (ID 1.5m, height 150/225/300/600/900/1200 mm, wall thickness 125mm) below conical piece as per required depth of manhole and having steel reinforcement in conical piece @ not less than 80 kg per cum of concrete, including cast-in-situ PCC M-10 grade (1:3:6) foundation of 2.125m dia and 150mm thickness, PCC M15 grade circular wall ID 1.425 m, wall thickness 200mm, height equal to ID of sewer pipe + one wall thickness of pipe + 50 mm (to flush the manhole frame with road top, height of wall can be increased but not more than 100mm), PCC M15 grade benching and channel portion and up to top level of sewer pipe etc complete with curing compaction and form work, supplying and fixing heavy duty SFRC manhole cover as per IS 12592 (Part I and II), supplying andfixing plastic encapsulated CI/MS footsteps / SFRC footsteps, including cost of shuttering, steel reinforcement, testing for water tightness etc complete in all respect as per drawing, as per specification and the direction of the Engineer. Note:- Excavation of earth work and road cutting for manhole will be measured and paid separately. |
| 524 | Pre-cast RCC M-40 grade circular manhole conical piece with inbuilt cover and frame (height 1.305), cast-in-situ PCC M-10 grade foundation, PCC M15 grade circular wall ID 1.425m, wall thickness 200mm, wall height equal to ID of sewer pipe + one wall thickness of pipe + 50 mm, PCC M15 grade benching and channel portion. Depth of manhole shall be measured from top of manhole cover upto lowest invert of pipe. (Depth includes in the item = height of Conical piece + ID of Sewer pipe + 1 Wall thickness of pipe + increased height of wall (if any) + 50mm) |
| 525 | Providing and fixing pre-cast RCC M-40 grade circular ring of ID 1.5m, wall thickness 125mm, height 150/225/300/600/900/1200mm for constructing extra depth of manhole beyond depth mentioned in item no-17.61.1 as per drawing. |
| 526 | Providing and making connection to the manhole/ road side chamber/ property chamber by cutting hole in wall, making good the same with brick work/ stone masonry work in cement mortar 1:4, plaster in cement mortar 1:3, encasement of pipe at manhole with 75mm thick M15 grade concrete etc complete as directed by Engineer. |
| 527 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths full round HDPE DWC (double wall corrugated) pipes of SN8 grade as per IS 16098 (Part 2) amended upto date in trenches in complete including all material, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications, drawings and as per direction of Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. |
| 528 | 200 mm ID |
| 529 | 250 mm ID |
| 530 | 300 mm ID |
| 531 | 400 mm ID |
| 532 | Providing and laying plain cement concrete M15 grade (using mechanical concrete mixer) using 20mm graded hard crusher broken stone aggregate, laying in layers of not more than 15cm thick, for bedding having width = outer dia of pipe (Bc) + 200mm or 1.25Bc (whichever is higher), thickness below pipe = 0.25Bc or 100mm (whichever is higher) and haunching = 0.25Bc, for all type of pipes of following sizes, including compaction, curing, form work, etc complete as per drawing and/ or as directed by Engineer |
| 533 | 200 mm internal diameter |
| 534 | 250 mm internal diameter |
| 535 | 300 mm internal diameter |
| 536 | 400 mm internal diameter |
| 537 | Constructing providing and fixing of pre-cast RCC M-40 grade circular Road Side Inspection Chamber including earthwork with following dia and depth cylindrical piece with 100mm wall thickness, inbuilt 100mm thick base slab, inbuilt cover & frame on top, provision for 110mm OD in and out sewer connection with making proper inbuilt benching and channel with PCC M-15 grade including providing cast-in-situ 100mm thick base foundation of PCC M-10 grade, supplying and fixing circular precast SFRC Circular 300 / 450 mm dia manhole cover with frame MD-10 (as per IS-12592 amended upto date), including steel reinforcement minimum @ 80kg/cum, testing for water tightness complete in all respect as per drawing, specification and the direction of the Engineer. |
| 538 | Pre-cast Road side inspection chamber of 450mm dia (internal), 900mm depth and 750mm dia base foundation |
| 539 | Excavating trenches of required width for pipe cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.: All kinds of soil |
| 540 | Pipes cables etc. not exceeding 80mm dia |
| 541 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 542 | for Horizontal installation |
| 543 | 40 mm OD 4kg/ cm2 |
| 544 | 50 mm OD 4 kg/ cm2 |
| 545 | 63 mm OD 4 kg/ cm2 |
| 546 | Providing & fixing of Gear Driven Rain gun sprinkler, grillo (Ajay (Indra)/Rain Bird/Premier-Full/ Part circle) with oscillating arm having radius of 41m and flow of 617lpm at an operative pressure of 5 kg/cm.sq, having 11/2\\" inlet. The body of sprinkler is made of aluminium alloy duty protected in its main parts by brass stainless steel and techno polymers. The sprinkler is equipped with Jet breaker and four different nozzles. |
| 547 | Providing and fixing of self closing spring loaded quick coupling 3/4\\" hydrant (Drip'n'Drip /Whethermetic/ Premier); made of Aluminium alloy doly procted ints main parts by brass stainless steel and techno polymors & having self closing thermoplastic hinged lid, anti rotating device and with requirew no. of 3/4\\" key for quick coupling hydrant made up of Aluminium alloy ;doly procted. An electro galvanized MS saddle with 3/4\\" G.I Riser with galvanized nut & bolts and parallel female thread (pressure tight) shall be used to connect the quick coupling hydrant to the pipeline. |
| 548 | Providing and fixing of Auto Flush Hot dip galvanised Screen filter 40m3/Hr confirming to IS 12785:1994 having inlet & outlets connections of 3\\", 2 pressure gauge ports of 3/4\\", 2\\" outlet for flushing of at bottom of filter & maximum working pressure of 14 bars with 2 Pressure Gauze (glycerine filled). 4\\" (0-10 kg/cm2). (Make – Drip 'n' Drip, AZUD) |
| 549 | P/F 20 Cum Gravel filter of GI with 20 nos mushrooms having gravel size 1-2mm & thickness 600 mm of mable chips with total quantity of 150.00 kg comprising with back wash assembly complete in all respect as per Drg. No. 11 & direction of engineer in charge (Neafime, NAAN HARVEL make) |
| 550 | P/F 20 Cum DISC FILTER of arcylic plastic body with 120mesh fine filter with 150 Disc's having back wash valve complete direction of engineer in charge (Neafime, NAAN HARVEL ) |
| 551 | P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.\\"B\\" Class |
| 552 | 32mm dia nominal bore |
| 553 | Making connection of G.I. distribution branch with G.I. mainincluding all fitting. |
| 554 | Beyond 25mm & upto 100mm dia |
| 555 | P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:Horizontal |
| 556 | (a) 32mm nominal bore. |
| 557 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. |
| 558 | Nominal bore 150 mm dia. |
| 559 | Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. |
| 560 | Nominal bore 150 mm dia. |
| 561 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes |
| 562 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) |
| 563 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 564 | 150 mm dia |
| 565 | Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect. |
| 566 | 40 mm dia |
| 567 | Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. |
| 568 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. |
| 569 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 570 | Up to 2.0 KW |
| 571 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 572 | 3 core 6.0 Sq.mm |
| 573 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase upto 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply. |
| 574 | Providing & Laying P.V.C./XLPE insulated & P.V.C. sheathed Armoured aluminium cable conf to IS:1554 P-I / of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity> 99.60%, round/flat strip armouring of cables, inner / outer sheath confirming to IS:5831 in existing RCC/Hume? Stoneware/PVC pipe/ Open duct/ cable trench/ cable tray (with cable tie) including testing etc.as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product/work refer Annexure \\"A\\" attached with this BSR. |
| 575 | (b) 10.00 sqmm 2 core |
| 576 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRTH Specification Clause 401. |
| 577 | For Grading I Material |
| 578 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400-12 & 400-13 and MoRTH Specification Clause 406. |
| 579 | By Mechanical Means with all lead |
| 580 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base(WBM/WMM) including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per MoRTH Specification Clause 502 |
| 581 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per MoRTH Specification Clause 503. |
| 582 | Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500-7 premixed with bituminous binder, transported to site with all leads laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per MoRTH Specification Clause 504. |
| 583 | Bitumen (VG-30) |
| 584 | Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH Specifications Clause 507 complete in all respects |
| 585 | for Grading-II(13 mm nominal size) Bitumen (VG-30) |
| 586 | Providing and laying Synthetic Athletics Track FULL PUR SYSTEM system including WA Standard markings on the surface all complete as per requirements/ specifications laid down by WA class -I certification and as per direction of the Engineer-in-charge.The offered product should be of European, Australian and American origin only. |
| 587 | (ii) High Stress Areas with a minimum thickness of 20 mm of finished Track Surface. |
| 588 | Providing and fixing Mandana Cobble Stone flooring work dressed stone 100mm thick in hound finished with pattern as per approved design over 25-50mm thick base in CM 1:6 incl. pointing with cement sand mortar 1:2 (1 Cement:2 sand)match the shade of stone with joint complete in all respect as per direction of engineer-in-charge & Architect with all lead & lift. |
| 589 | Providing and fixing Black Cadappa Cobble Stone flooring work dressed stone 100mm thick in hound finished with pattern as per approved design over 25-50mm thick base in CM 1:6 incl. pointing with cement sand mortar 1:2 (1 Cement:2 sand)match the shade of stone with joint as per direction of engineer-in- charge |
| 590 | Spreading of manure , good earth in required thickness (cost of manure and good earth to be separately ) |
| 591 | O&M of Swimming pool & GymComprehensive Operation, Maintenace, Cleaning & Security work Services for Civil, Electrical, Horticulture and MEP (Mechanical, Electrical, Plumbing) installed at the Swiming pool Building .The Scope of the work includes Operation & routine, preventive and breakdown maintenance of all associated infrastructure to ensure they remain in functional and safe condition. Operation & maintenace of Swimming Pool, Filtration plant and Pumps, Chemical Dosing for Pool, Gym, Cutting and maintainance of Grass and Plants , Cleaning , Security and maintainance of Entire campus , Pool , Parking and Open area , Gym , Multipurpose hall , Toilets , Changing rooms , Lifts Pump room , Electrical Items Etc. . The rate shall be inclusive of all specialized skilled/unskilled manpower for Operation, maintenance & Security by necessary tools & tackles, Life Guards, safety gears (PPE), test equipment and consumables Items.\\"Complete in all respect and as per dirction of Engineer-in-charge. |
| 592 | O&M of StadiumComprehensive operation, Maintenace, Cleaning & Security work Services for Civil, Electrical, Horticulture and MEP (Mechanical, Electrical, Plumbing) installed at the Cricket Stadium .The Scope of the work includes Operation & routine, preventive and breakdown maintenance of all associated infrastructure to ensure they remain in functional and safe condition. Cutting and maintainance of Grass and Plants, Pitch Area, Cleaning , Security and maintainance of Entire stadium campus , All Buildings , General stands , Parking and Open area , Practice ground , Toilets , Lifts , Electrical Items Etc. . The rate shall be inclusive of all specialized skilled/unskilled manpower for Operation, maintenance & Security by necessary tools & tackles, safety gears (PPE), test equipment and consumables Items. \\"Complete in all respect and as per dirction of Engineer-in-charge. |
| 593 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 594 | Short point (up to 3 mtr.) |
| 595 | Medium point (up to 6 mtr.) |
| 596 | Long point (up to 10 mtr.) |
| 597 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 598 | Short point (up to 3 mtr.) |
| 599 | Medium point (up to 6 mtr.) |
| 600 | Long point (up to 10 mtr.) |
| 601 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 602 | On board |
| 603 | Short point (up to 3 mtr.) |
| 604 | Medium point (up to 6 mtr.) |
| 605 | Long point (up to 10 mtr..) |
| 606 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 607 | 20 mm |
| 608 | 25 mm |
| 609 | 32 mm |
| 610 | 40 mm |
| 611 | 50 mm |
| 612 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 613 | 1 x 1.5 sq.mm |
| 614 | 3x 1.5 sq.mm |
| 615 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 616 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 617 | 1 x 6.0 sq.mm |
| 618 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 619 | 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. |
| 620 | 4 x 10.0 sq.mm |
| 621 | 4 x 16.0 sq.mm |
| 622 | Supply and laying following size twin parallel type Speaker cables of IS/ISO 9001 CERTIFIED COMPANY made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 623 | 1.5 Sq.mm |
| 624 | Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 625 | 3 Module |
| 626 | 1-2 Module |
| 627 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 628 | Single pole MCB (With B / C curve tripping characteristics) |
| 629 | 0.5 A to 5 A rating |
| 630 | 6 A to 32 A rating |
| 631 | 40 A rating |
| 632 | Double pole MCB (With B / C curve tripping characteristics) |
| 633 | 40 A rating |
| 634 | 6 A to 32 A rating |
| 635 | Triple pole MCB (With B / C curve tripping characteristics) |
| 636 | 6 A to 32 A rating |
| 637 | 40 A rating |
| 638 | 50/63 A rating |
| 639 | Four pole MCB (With B / C curve tripping characteristics) |
| 640 | 6 A to 32 A rating |
| 641 | 40 A rating |
| 642 | 50/63 A rating |
| 643 | Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 644 | Two pole 100/300mA sensitivity |
| 645 | 40 A rating |
| 646 | 63 A rating |
| 647 | Providing & Fixing of din rail mounting contactor and accessories confirming to IEC 61095 with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 648 | Modular contactor 40A - 4NO |
| 649 | Auxilary contact, 1 NO + 1 NC |
| 650 | Providing & Fixing of din rail mounting LED Indicating Lights with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 651 | Red / Yellow / Blue / Green |
| 652 | Red-yellow-Blue |
| 653 | Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 654 | Suitable for Two / Three / Four module for MCB |
| 655 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 656 | Glazed door (single phase) IK-09 and IP-43 with Metal end box |
| 657 | 8 Way (8+2) |
| 658 | 12 Way (12+2) |
| 659 | Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box |
| 660 | 6Way {8 Incomer + 6 Sub Incomer (2+2+2) + 18 out going } |
| 661 | 8Way. {8 Incomer + 6 Sub Incomer (2+2+2) + 24 out going } |
| 662 | 12 Way(Incomer 8,Sub Incomer2+2+2) |
| 663 | P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 664 | 20 amp, 2 pin + scrapping Earth, 1 Module |
| 665 | 20 amp, 3 pin + scrapping Earth, 4 Module |
| 666 | 32 amp, 5 pin + scrapping Earth, 8 Module |
| 667 | P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 668 | IP -67, IK - 09 Panel mounted socket |
| 669 | 16 A 3 pin(2P+E) |
| 670 | 32 A (3P+N+E) |
| 671 | 63 A (3P+N+E) |
| 672 | IP -67, IK-09 Surface/Wall mounted socket |
| 673 | 32 A (3P+N+E) |
| 674 | 63 A (3P+N+E) |
| 675 | IP -67 Surface/Wall mounted Interlocked Switched socket Outlet Vertical |
| 676 | 16 A 3 pin(2P+E) |
| 677 | 32 A 3 pin(2P+E) |
| 678 | 32 A 5 pin(3P+N+E) |
| 679 | IP - 67 Plug top |
| 680 | 32 A (3P+N+E) |
| 681 | 63 A (3P+N+E) |
| 682 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 683 | Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box |
| 684 | 8 Way |
| 685 | 12 Way |
| 686 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal End Box |
| 687 | 8 Way |
| 688 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 200/250 A Rating with metal End Box |
| 689 | 8 Way |
| 690 | P & F Surface mounting IP-65, IK-09 Class-II self extinguishing insulating material weather proof cabinets confirming to EN60439-3 with IP-65 Key lock, fully reversible door and cabinet, removable chasis and face plates, of following size. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 691 | 3 row x 12 module |
| 692 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 693 | 10 A one way switch |
| 694 | 10 A two way switch |
| 695 | 16 A one way switch 1M |
| 696 | 10 A bell push |
| 697 | 16 Amp. 2 Module switch With Led Indicator |
| 698 | 25 Amp. 2 Module switch With Led Indicator |
| 699 | 32 Amp. 2 Module switch With Led Indicator |
| 700 | Providing & Fixing of of ISO certified company made Multiple socket with surge and spikes protection cartridge not less then 5 KV as per PWD specification for electrical Works with minimum four nos. universal 6 A sockets, one 6 A switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr. including making connection etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 701 | Providing & Fixing of shackle (iron hook) made from 2mm nominal thick CRCA sheet and bolts (2nos) of 6mm with spring washer nut, checknut & split pin as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 702 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 703 | Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 704 | Providing & Fixing of modular type lockable feature socket duly made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 705 | 6 A 3/5 pin shuttered socket |
| 706 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 707 | 5 step fan regulator 2 Module 360 dgree rotating |
| 708 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 709 | RJ-11 telephone jack Double line |
| 710 | USB Charger 1 A - 1 M with BIS mark |
| 711 | RJ-45, Cat 6 computer jack with shutter |
| 712 | T.V. coaxial socket |
| 713 | Blanking plate |
| 714 | 25 Amp. 2 Module Motor Starter with on / off Push button |
| 715 | LED Skirting /Foot Light 2 Module |
| 716 | Electronic Chime/Buzzer 2M |
| 717 | Modular MCB 6 A to 32 A SP |
| 718 | Modular MCB 6 A to 32 A DP |
| 719 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 720 | 3 Module |
| 721 | Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 722 | 3 Module |
| 723 | Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 724 | 1-2-3 Module |
| 725 | Providing & Fixing of ISO certified company made virgin material PVC trunking system as per PWD specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM shall have submit NABL accrediated /CPET lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 726 | 80mm x 50mm |
| 727 | 100/105mm x 50mm |
| 728 | Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. . For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 729 | P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferruling and punching of telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 730 | 10 Pairs |
| 731 | 20 Pairs |
| 732 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 733 | Electrolytic grade Aluminium bus bar 6010 grade |
| 734 | Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1.0 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 735 | Three phase Ammeter with Inbuilt Selector Switch |
| 736 | Three phase Voltmeter with Inbuilt Selector Switch |
| 737 | Three phase KWH Meter |
| 738 | Three phase KWH Meter Dual Source |
| 739 | Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS Meter |
| 740 | Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS Meter |
| 741 | Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 Meter |
| 742 | Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . |
| 743 | Resin cast wound type CT |
| 744 | C T Class 1, Ratio upto 150/5, Burden 5 VA |
| 745 | C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA |
| 746 | C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA |
| 747 | C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA |
| 748 | C T Class 1, Ratio 3200/5 to 4000/5, Burden 15 VA |
| 749 | Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 750 | Voltage Between Phases with OFF ( 4 Position ) |
| 751 | Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 752 | Providing & Fixing of 10 A Cam operated rotary (Local- Remote, Auto - manual) switches on existing panel with 1 pole 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . |
| 753 | Providing & Fixing of 25 A TNC ( Trip - neutal - close ) switch to control remotely on existing panel as required. |
| 754 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 755 | Red/yellow/Green colour |
| 756 | Blue / white Colour |
| 757 | Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 758 | Luminous type Red , Yellow, Green, Amber |
| 759 | Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 760 | 3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) |
| 761 | 11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms) |
| 762 | Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 763 | Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank) |
| 764 | Providing & Fixing of 3-Phase 415/440 V , 7 % / 14 % Detuned Reactors conforming to IEC 61558-2-20 & IEC 60076-6 Aluminium wound for harmonics filter with 180% to 200 % Linearity, H - Class Insulation ( 180 degree C), high temp. Disconnection above 155 deg C., ambient temperature: +60 deg C. with thermal cut off switch in existing panel with following Capacitor ratings. including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 765 | 7 % (189 Hz) Aluminium wound Reactors |
| 766 | For 1 to 5 KVAR capacitor |
| 767 | 10 KVAR |
| 768 | 15 KVAR |
| 769 | 20 KVAR |
| 770 | 25 KVAR |
| 771 | 50 KVAR |
| 772 | Providing & Fixing of microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay with Approx. Size 139 mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analyzing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, High voltage, THD-I & THD-V insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi Built in MFM with PF Controller LCD Display, CT polarity auto correction % THD up to 30 harmonics level, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT for sensing the relay including making connection with 1.5 Sq.mm copper wire etc. as required. |
| 773 | 12 to 16 stage |
| 774 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 775 | 3 pole Power contactors with following AC 3 Rating |
| 776 | 32 Amp. |
| 777 | 40 Amp |
| 778 | 70 Amp |
| 779 | 140 Amp |
| 780 | 250 Amp |
| 781 | Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works, IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 782 | up to 6 KVAR |
| 783 | 10 KVAR |
| 784 | 15.0 KVAR |
| 785 | 20.0 KVAR |
| 786 | 25.0 KVAR |
| 787 | 50.0 KVAR |
| 788 | P & F of Auxiliary Contactor for AC control standard. 24 V Coil 110, 240 V, 415 V, 50 Hz conforming to IS:13947-4-1/IEC:60947-4-1 with required NO & NC combination including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 789 | P & F of Front / Side mounting Add on Auxiliary Contact Block with required NO & NC combination including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 790 | Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 791 | One day & week reserve (digital type ) |
| 792 | P & F of Automatic Transfer Switch (ATS) confirming to IEC60947-6-1, Utilization cateogory AC-33B in Existing panel for automatic on load transfer between two source power supply of 415V through Solenoid/Motorised mechanism and integrated with three positions realize fast transfer within 100 ms. ATS shall have three postions (S1-OFF-S2) , Manual / Auto Override feature, The two sources can be isolated in the off position with a padlock. capability to expand with RS 485 communication module, which can ensure real-time transmission of communication data. ATS shall have automatic generator start & stop control function; Auxillary contacts to indicate mechanical positions. Minimum Electrical operations 6000, of following Current ratings, including making connections etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 793 | 800 Amps |
| 794 | 630 Amps |
| 795 | SITC of IP-43 and general construction confirming to IEC 61439-1&2. type tested assembly (TTA) wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- |
| 796 | (a) Panel having short circuit withstand capacity of minimum of 50 kA for 1s (Icw rating) at 415 V, 50 HZ AC supply, Rated Impulse withstand voltage (Uimp) of 12kV for withstanding against transient Over voltage, mechanical impact level of IK10 level and internal arc for 50 kA for 0.3 second with aluminum busbar and fully type tested at an Independent Laboratory, Type test certificate has to be submitted for all rating of LV Switchgear to be used in Panel. |
| 797 | (b) All four Horizontal Busbars shall be in same compartment. Certified design of switchboards shall be proven design from OEM (Switchgear Manufacturer). OEM name should be mentioned on top of each column of switchboard. Also, OEM Partnership Certificate shall be furnished by Panel builder. Panel shall be fully modular with standard OEM designas per latest IEC 61439 Part 1&2 standard |
| 798 | © Panels and cubicles shall be fabricated with CRCA Sheet Steel of thickness, same as as per OEM Design. Sheet Steel having vibration free structure chemically treated with nine tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity Aluminium busbar extensible type, busbar supports, ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) |
| 799 | (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. |
| 800 | (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. |
| 801 | (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) |
| 802 | (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. |
| 803 | (h) only outer surface area on all sides shall be measured & panel to be fabricated only from Switchgear OEM approved fabricators only. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 804 | SITC of Draw out type 3/4 pole door interlock Air Circuit Breaker (ACB) as conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440 V, 50 Hz and having adjustable over load short-circuit, Instantaneous , earth fault (LSIG) with separate LED indication for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 trip history, provision of ZSI, Communication, Power metering module, Thermal memory , trip free mechanisum , suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping feature , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electrical operation 10000 upto 2000 A rating and 5,000 for 2500 A to 4000 A. including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 805 | Microprocessor based release Draw out type ( Motorised charging type ) 4 Pole |
| 806 | 630/800 A Rating ,50 kA |
| 807 | 1000 A Rating , 50 kA |
| 808 | 1250 A Rating ,50 kA |
| 809 | Supply and fixing of following accessories for Air circuit breaker (ACB) compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 810 | Mechanical Interlocking Kit using key & Lock |
| 811 | Closing Release |
| 812 | Shunt Trip Release |
| 813 | Under voltage Release |
| 814 | External Neutral CT cast resin |
| 815 | Microswitch for Indication |
| 816 | Operation Counter |
| 817 | Door Interlock |
| 818 | Auxiliary Contact 4 NO + 4 NC |
| 819 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 820 | 3 pole MCCB With Thermal Magnetic release |
| 821 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 822 | 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 823 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 824 | 4 pole MCCB With Thermal Magnetic release |
| 825 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting |
| 826 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 827 | 125 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 828 | 160 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 829 | 200 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 830 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 831 | 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 832 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 833 | 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 834 | 800 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 835 | Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 836 | Extended Rotary Handle |
| 837 | Auxiliary contact |
| 838 | Trip Alarm contact |
| 839 | Auxiliary + Trip alarm contact |
| 840 | Spreaders upto 125A, 3 Pole MCCB |
| 841 | Spreaders for 160A, 3 Pole MCCB |
| 842 | Spreaders for 160A, 4 Pole MCCB |
| 843 | Spreaders for 250A, 3 Pole MCCB |
| 844 | Spreaders for 250A, 4 Pole MCCB |
| 845 | Spreaders for 400A, 4Pole MCCB |
| 846 | Spreaders for 630A, 4Pole MCCB |
| 847 | Spreaders for 800A, 4Pole MCCB |
| 848 | External Neutral CT with Adaptor Kit |
| 849 | Current Metering Module |
| 850 | Providing & Fixing of IK08 and IP-30 Recessed/surface mounting heavy duty Enclosure suitable for mounting 3 / 4 pole MCCB, Inbuilt neutral linkmade out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations, detachable gland plate, including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 851 | Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable |
| 852 | Suitable to accommodate above 70 sqmm 3.5 core Al arm. Cable to 185 Sqm , 3.5 core Al Arm. Cable |
| 853 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 854 | 10.0 Sq. mm |
| 855 | 4 core |
| 856 | 35.0 Sq. mm |
| 857 | 3.5 core |
| 858 | 50.0 Sq. mm |
| 859 | 3.5 core |
| 860 | 70.0 Sq. mm |
| 861 | 3.5 core |
| 862 | 95.0 Sq. mm |
| 863 | 3.5 core |
| 864 | 185.0 Sq. mm |
| 865 | 3.5 core |
| 866 | 300.0 Sq. mm |
| 867 | 3.5 core |
| 868 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 869 | 1.5 Sq. mm |
| 870 | 8 core |
| 871 | 16.0 Sq. mm |
| 872 | 1 core |
| 873 | 25.0 Sq. mm |
| 874 | 1 core |
| 875 | 4.0 Sq. mm |
| 876 | 4 core |
| 877 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 878 | 1.5 Sq. mm |
| 879 | 10 core |
| 880 | 2.5 Sq. mm |
| 881 | 2 core |
| 882 | 3 core |
| 883 | 10 core |
| 884 | 4.0 Sq. mm |
| 885 | 3 core |
| 886 | 6.0 Sq. mm |
| 887 | 4 core |
| 888 | 10.0 Sq. mm |
| 889 | 4 core |
| 890 | 16.0 Sq. mm |
| 891 | 4 core |
| 892 | 25.0 Sq. mm |
| 893 | 4 core |
| 894 | 35 Sq. mm |
| 895 | 4 core |
| 896 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 897 | Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 898 | Add Extra for Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points :- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 /Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 899 | Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 900 | Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 901 | Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 902 | Above 35 sq. mm and upto 95 sq. mm fixed with 40 mm x 3 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 903 | Above 95 sq. mm and upto 185 sq. mm fixed with 40 mm x 4 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 904 | Above 185 sq. mm and upto 400 sq. mm fixed with 50 mm x 5 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 905 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 906 | 3.5 x 35.0 sq.mm |
| 907 | 3.5 x 50.0 sq.mm |
| 908 | 3.5 x 70.0 sq.mm |
| 909 | 3.5 x 95.0 sq.mm |
| 910 | 3.5 x 120.0 sq.mm |
| 911 | 3.5 x 150.0 sq.mm |
| 912 | 3.5 x 185.0 sq.mm |
| 913 | 3.5 x 240.0 sq.mm |
| 914 | 3.5 x 300.0 sq.mm |
| 915 | Supply, Fabricating & installing following sizes of Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with rungs at span of 250mm including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/wall with M.S. suspenders etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 916 | 150mm x 50mm x 1.6mm |
| 917 | 300mm x 50mm x 1.6mm |
| 918 | Supply and fixing following size of Hot dipped Galvanized (275 GSM) floor raceways / Under floor trunking with/ without partion, including common cover, joint sleeve, cross over junction Box etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 919 | 100 mm x 25 mm x 1.5 mm |
| 920 | Supply and fixing following Hot dipped Galvanized (275 GSM) accessories for floor raceways / Under floor trunking etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 921 | Access Outlet 300 mm x 300 mm x 40-75 mm with Galvanized Lid |
| 922 | S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required |
| 923 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 924 | 50 mm |
| 925 | 90 mm |
| 926 | 120 mm |
| 927 | 160 mm |
| 928 | Providing and laying Non Pressure NP-3 class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) etc. as required. (Excavation of Earth & Back filling with compaction is to be Paid Extra). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 929 | 200 mm Dia. |
| 930 | labour charges for Excavating trenches of required width for pipes dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.: |
| 931 | All kind of Soils |
| 932 | Hard Rocks |
| 933 | Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 934 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 935 | (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts |
| 936 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 937 | (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. |
| 938 | (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. |
| 939 | (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 940 | 17.2 mm thick and 3 Mtr. Long |
| 941 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 942 | 50mm x 6mm copper strip |
| 943 | 25mm x 6mm G.I. ( Hot Dipped ) Strip |
| 944 | 32mm x6mm G.I. ( Hot Dipped ) Strip |
| 945 | 50mm x 6mm G.I. ( Hot Dipped ) Strip |
| 946 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 947 | 8 SWG G.I. ( Hot Dipped ) Wire |
| 948 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR . |
| 949 | 40 mm dia. |
| 950 | 65 mm dia. |
| 951 | S & F of Earth Bar with Disconnecting link Made out from 50 mm x 6 mm copper purity purity >95% /GI strip pre fitted on epoxy powder coated metal base mounted on hexagonal SMC Insulators of following Size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR . |
| 952 | 600 mm , 10 Way Copper |
| 953 | 600 mm , 10 Way GI |
| 954 | Supply, installation, testing & commissioning of following size & Material air termination rods confirming to IEC/EN 62561 with suitable OEM recommended mounting arrangement on parapet wall all as per standard , complete as required. the test report accredited by third party accreditation body like VDE/ ILAC/ DAkkS/ UL/ NABL is to be submitted.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR . |
| 955 | 2000 mm long, 16mm rod tapered to 10 mm, AlMgSi |
| 956 | Supply & Fixing Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 10 / 16 mm and Clamping range of conductor Rd 2x 8-10 mm, & Complied as per Standard EN 62561-1, tested to carry from 100KA (10/350μs) lightning current the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR . |
| 957 | Supply & Laying of Aluminum / SS / AlMgSi Round Conductor confirming to IEC/EN 62561 etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. ( Supporting Clamps to be paid Extra )All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR . |
| 958 | 8 mm Dia. Aluminium conductor |
| 959 | 8 mm Dia. AlMgSi conductor |
| 960 | Supply, installation, and testing of an Early Streamer Emission (ESE) Air Terminal, designed and tested in accordance with NFC 17-102 standards, with Delta T ( Initiation Advance ) time tested and certified by an ILAC-accredited high-voltage test laboratory. The air terminal shall be constructed from corrosion-resistant materials to ensure durability and long-term performance. It shall be installed at the highest point of the structure and mounted on a mast of minimum 5.5 meters or as determined by the initiation advance time (ΔT) calculations, ensuring the required protection radius. The protection radius shall be determined as per NFC 17-102, based on the level of risk protection required (Levels I to IV), with proper Earthings integration for effective lightning dissipation. |
| 961 | ES-60 Triggering Advance Time (ΔT) -60µs, Protection Radius (meters) as per Highest Risk 79 Mtr. |
| 962 | Providing & Fixing of 1200 mm sweep BLDC technology power saving ceiling fan which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe up to 80 cm , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 963 | With Remote |
| 964 | Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be <= 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote ) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 965 | Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM |
| 966 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 967 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 968 | 300 mm sweep(900 RPM) |
| 969 | 450 mm sweep(900/1400 RPM) |
| 970 | Providing & Fixing of of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 971 | 250 mm sweep |
| 972 | Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 973 | P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Opening of following size and made out from 24 SWG GI sheet as per instructions of Engineer in charge including fixing with suitable fasteners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 974 | Suitable for 300 mm sweep Exhaust Fan |
| 975 | S & F Extruded Aluminium Fresh Air / External Weather Louvre, Small Format type with 38 mm Flange width & 50 mm depth. Finish - Powder coated Off white with Alum. Mesh of required Size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 976 | Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloy connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 977 | 15 Ltr. |
| 978 | 25 Ltr. |
| 979 | SITC of IP20 SMD Mid Power LED batten with integrated box (min.1200mmx40mmx60mm including reflector) with replacable driver fixture made from Powder coated Extruded aluminium housing ,Min. lumen output 4800 lm, System lumen efficacy ≥ 120 lm/Watt output nly at CW (5700K to 6500K), internal surge protection of 4.0 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 980 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 981 | 570mm (+/-10%) batten with min. lumen output 1000 lm |
| 982 | SITC of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥120 lm/Watt output only at CW (5700K to 6500K) , THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 983 | Minimum lumen output 1200 lm |
| 984 | SITC of IP-20 LED Recessed / Surface Mounted, Round / Sqaure backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCm (standard deviation colour matching)<5.life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 985 | Recessed Mounting |
| 986 | Minimum lumen output 1950 lm |
| 987 | Minimum lumen output 2400 lm |
| 988 | Surface Mounting (with extruded alumn. Housing ) |
| 989 | Minimum lumen output 1950 lm |
| 990 | Minimum lumen output 2400 lm |
| 991 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 992 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 993 | Recessed Mounting |
| 994 | Minimum lumen output 330 lm |
| 995 | Minimum lumen output 650 lm |
| 996 | Minimum lumen output 1300 lm |
| 997 | Minimum lumen output 1600 lm |
| 998 | Surface Mounting (with extruded alumn. Housing ) |
| 999 | Minimum lumen output 1300 lm |
| 1000 | Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 1001 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1002 | Recessed Mounting |
| 1003 | Minimum lumen output 3000 lm |
| 1004 | Minimum lumen output 4200 lm |
| 1005 | Surface Moutning |
| 1006 | Minimum lumen output 3600 lm |
| 1007 | Minimum lumen output 4200 lm |
| 1008 | Providing & Fixing of IP20, 1100-1200 mm x 50-60 mm x 70-85 mm size Suspended mounting Mid power SMD type LED linear Light fixture made from Extruded Aluminium housing, PMMI diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 100 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 1009 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1010 | Minimum lumen output 2000 lm |
| 1011 | Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 4 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1012 | Minimum lumen output 1000 lm |
| 1013 | Providing & Fixing of IP65 IK08 rated Integrated High power LED ( each LED between 3 to 5 watt power with secondary lencs on each LED) Highbay light fixture made from Pressure Die Cast Aluminium housing, toughned glass diffuser, potted driver, Eye bolt for mounting, system lumen efficacy ≥140 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 4 KV inbuilt & 10 KV external inside fixture. |
| 1014 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1015 | Minimum lumen output 10000 lm |
| 1016 | Minimum lumen output 14000 lm |
| 1017 | Minimum lumen output 16500 lm |
| 1018 | SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , UGR (unified glare rating)<19, fliker free (current ripple should be below 5%), SDCm (standard deviation colour matching)<5 life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 1019 | Recessed Mounting |
| 1020 | Minimum lumen output 4800 lm |
| 1021 | Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1022 | Poles with Octagonal Cross Section |
| 1023 | 3 Mtr. |
| 1024 | 9 Mtr. |
| 1025 | Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1026 | Single arm overhang |
| 1027 | Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1028 | A) Excavation of Pit for Foundation Size upto required depth from Ground level |
| 1029 | B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. |
| 1030 | C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness |
| 1031 | D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. |
| 1032 | E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal |
| 1033 | F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations. |
| 1034 | G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. |
| 1035 | H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. |
| 1036 | Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr. |
| 1037 | Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. |
| 1038 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1039 | LED Street Light fixture with Minimum lumen output 8700 lm |
| 1040 | LED Street Light fixture with Minimum lumen output 12500 lm |
| 1041 | Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes. |
| 1042 | 320 x 440 x 179 mm |
| 1043 | Supply and erection of PU coated , 6 to 7 mm thick Glass / Fibre Reinforced Pole (GRP /FRP) made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. designed to withstand the maximum wind speed as per IS 875, and Tested for deflection not more than 15% length of pole as per ASTM D 4923, The pole should be in one piece and tapered round in shape, pole shafts shall be provided with FRP Anchor with suitable MS cated Base with provision for fixing 4 no. foundation bolts( Including cost of Foundation Bolt), The Pole shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension on Existing cement concrete foundation. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1044 | 6 Mtr. Long, Top/ Bottom OD Dia 89/152mm ± 2mm approx. With Base 250X250 X 10mm |
| 1045 | Supply, Erection and Fixing of GRP Overhang with cap over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1046 | Single arm overhang |
| 1047 | Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1048 | Minimum lumen output 3000 lm Post top Luminarie |
| 1049 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1050 | High Power LED Flood Light Minimum lumen output 12400 lm |
| 1051 | High Power LED Flood Light Minimum lumen output 30000 lm |
| 1052 | Providing & Fixing of IK10 IP65 protected 600 mm height LED Bollard Luminarie with base plate made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1053 | Minimum lumen output 980 lm Bollard |
| 1054 | Providing & Fixing of IK10 IP66 / IP67 protected Rectangular shape LED Step Luminarie made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . driver current <750mA . Fixture must be in compliance with BIS Standards and Trade mak Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1055 | Minimum lumen output 630 lm Step light |
| 1056 | Providing & Fixing of IK10 IP65 / IP66 protected LED Up - Down Luminarie Wall / Surface mounting made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. COB LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1057 | Minimum lumen output 1300 lm Up-Down Luminary |
| 1058 | Providing & Fixing of IK10/ IP66 protected pole mount LED Post top Luminarie top & bottom made of single piece construction powder coated pressure die cast alluminium housing with High purity PC diffuser, downward illumination to control light pollution. The System level Luminous efficacy ≥ 120 Lumen/W. SMD LEDs is to be used, System CRI>/=70, CCT: 4000/5700 K. Driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.95, THD<10% and with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety, driver should be Phase to phase protection of 440 V for 4 Hrs. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED driving current <750mA. Mounting pole diameter 060mm, The Luminaire dimension min Dia 450mm x 200mm(H). including making connections etc. as required. |
| 1059 | Minimum lumen output 6000 lm Post top Luminaire |
| 1060 | Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1061 | 3 core 185.0 Sq.mm |
| 1062 | Add Extra for Laying of one number XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground including excavation of trench of size 120 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 1063 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1064 | 11 KV End Termination Kit Indoor type |
| 1065 | 3 core 120/150/185 Sq.mm |
| 1066 | 11 KV End Termination Kit Outdoor type |
| 1067 | 3 core 120/150/185 Sq.mm |
| 1068 | 11 KV Straight Through Joint Kit |
| 1069 | 3 core 120/150/185 Sq.mm |
| 1070 | SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 1071 | Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch |
| 1072 | SITC of Indoor Type Floor mounted metal clad 11 KV, 630 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification totally enclosed with Aluminium bus bar of 630 Amps for each phase, flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assambly of 3 vaccum interrupters (VCB manufacturer's own make) , with each pole individually encapsulated by epoxy insulations to make it dust proof and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker. |
| 1073 | interconnected with HT sleeve bus bar of 630 Amps , Basic Insulation level (BIL) : 28KV (RMS) / 75KV (Peak) and Altiude less than 1000 meters, including all protection, indication, Operation, monitoring and control and accessories etc. as required. Factory Tests of VCB panel as per System Integrator's QAP in it's own Manufacturing facility shall be witnessed by department Engineer virtually / Physically. (Cost of RCC Foundation / Steel Structure to be paid Extra). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1074 | Incoming Panel comprising of following: - VCB 630 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation.- Closing & tripping coil of VCB should be of continious rating to achive minimal failure.- Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters- Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. |
| 1075 | Outgoing Panel comprising of following: - VCB 630 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturer's own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) |
| 1076 | Bus Coupler Panel comprising of following: -VCB 630 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Space heaters - Power Pack (230V AC- 110V DC) |
| 1077 | S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 ( Correspnding level as per BIS amended upto date of receipt of tender) & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, undirectional rollers as required including carrying of pre-commission Testing & Charging of Transformer complete in all respect . Factory Tests : The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) in OEM's own lab and same shall be witnessed by Department engineer. Site Tests : Following tests shall be carried out on each transformer at site by OEM engineer in presence of department's site engineer:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor) |
| 1078 | Note :Manufacturer's testing laboratory should be certified by NABL and have an in house core cutting facility to ensure proper control & monitoring of quality. This is crutial to prevent the mixing of prime core materials with Second grade or defective materials. The core should be constructed from high grade, non ageing, PRIME GRADE CRGO steel with M4 Grade or Better, using silicon steel laminations, and should be of boltless design. The core and coil assembly should be undergo drying process using a highly efficient vacuum drying autoclave to remove moisture through heating and drying. |
| 1079 | 800 KVA with Off -LTC (+5% to - 10% @ 2.5%) % Impedance 5.0 |
| 1080 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries, FCBC ( Float cum boost charger)suitable for 415V +/-10%, 50 Hz , 1-ǿ / 3 -ǿ Input & 24/ 48 /110 V DC Output Natural Cooled, free standing in Sheet Steel enclosure,SCR controlled , regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,Built in DC Distribution Board (6 No MCB), indication , control as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1081 | SITC of Marshalling box fabricated out of 2.0 mm thick sheet steel, provided with water tight hinged doors with padlock arrangement, neoprene gasket all around door to make enclosure water and dust proof (IP-55). Space Heater, Illumination lamp, 5A switch & Socket, MCB, Viewing window, detachable gland plate completely wired, ready for external connections at the terminal blocks. All wirings shall be carried out with 1100 V grade PVC insulated stranded conductors. Power circuits if any shall be wired with stranded copper conductors of adequate sizes to suit the rated current. The minimum size shall be 2.5 sq.mm. Control, alarm and indication circuits, shall be wired with stranded copper conductor of sizes not smaller than 1.5 sq. mm. CT circuits shall be wired with stranded copper conductor of size not smaller than 4 sq.mm. including 150 mm dia. Winding temperature indicator with A&T contacts, 150 mm dia. Oil temperature indicator with A&T contacts , 150 mm dia. Magnetic Oil level Gauge ( MOG) with alarm contact, double float type Buchholz relay with isolating valves on both sides and as per IS: 3637 with A&T Contacts etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1082 | SITC of following capacity IK10 Sandwich Type Rising Mains / Bus Bar trunking Confirming to IEC 61439 part 1 & part 6 standard & IS 8623 P-II and Manufactured in India for use on 3 phase 4 wire , 50% integral earth , 415 volts, 50Hz A.C. supply , class F insulation, rated insulation voltage 1000V, impulse withstand voltage 12 KV, min. seismic zone 5 as per IS1893 (Part 1) , with IP-54/ IP-55 / IP-65(with Canopy) enclosure made of 1.5 mm thick sheet steel duly powder coated in convenient sections complete with 4 Nos aluminium (with IS 19501 or superior) bus bars, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre,continuous external earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system including making opening in RCC / Brick Masonary and repairing the same etc. as required. Type Tests reports like (i) Short Circuit Test (ii) Degree of Protection (iii) Temperature rise test of Rising main in CPRI / UL / ASTA/ LOVAG accrediated lab will be submitted by OEM. |
| 1083 | Note : Routine tests, as per OEM's QAP shall be conducted at the manufacturers facility in India and witnessed by the Departmental Engineer, either virtually or physically. Furthermore, complete Installation of Rising Mains shall be Vetted by Manufacturer before Comissioning. |
| 1084 | Sandwich Type Bus Rising Main IP-54 |
| 1085 | 630 amps 40 KA SC for 1 sec |
| 1086 | 800 amps 50 KA SC for 1 sec |
| 1087 | Out Door Bus Duct IP66 with Canopy |
| 1088 | 2000 Amps 80kA SC for 1 sec |
| 1089 | SITC of Bus Rising Main OEM manufactured following capacity End Feed Unit Confirming to ANSI C37.23 standard & IS 8623 P-II suitable for Sandwich / Compact Air Insulated type for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB/ACB (but without MCCB/ACB), Interlocking feature complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1090 | For 630 Amp. (Without MCCB) |
| 1091 | For 800 Amp. (Without MCCB) |
| 1092 | For 250 Amp. (Without MCCB) |
| 1093 | SITC of Bus Rising Main OEM manufactured Tinned copper flexible joint with enclosure of following capacity with Transformer / DG / Panel as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1094 | 2000 Amp. |
| 1095 | SITC of HT metering cubical panel as approved By DISCOMs fabricated out of 18 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX 6mm having provision for Following: (i)Provision for fixing Trivector / Import - Export Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set with Copper strip for Connection (To be supplied by DISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections, etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1096 | SITC of Radiator Cooled Silent DG Set (As per latest CPCB-IV+ emission norms) having specifications as per A, B, C, D, E, F & G : |
| 1097 | A) Diesel Engine : Turbo charged Diesel Engine ( conforming to BS:649/5514), multi cylinder, dynamically balanced flywheel, electric start of suitable BHP at 1500 rpm capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with silencer and Diesel oxidation catalyst & selective catalyst reduction system (isolated from main DG chamber), up to 1.50 M exhaust piping (with LRB insulation & Alum. cladding ) as required .Diesel engine should have Precise emission control by treatment with Diesel exhaust fluid (DEF)/Aqueous urea tank (above 82.5 KVA) as per CPCB 4+ norms |
| 1098 | B) Alternator : AC Brush less SPDP Synchronous alternator rated of appropriate KVA, 415 volts at 1500 rpm, 3 phase, 50 Hz, ac supply with 0.8 lagging power factor. Alternator conforming to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown). |
| 1099 | C) Canopy : CPCB / ARAI approved Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from CRCA sheet steel (structure) including sidewals & filled with glasswool (96Kg/m3) /PU Foam. as per IS8183 and the thickness of the doors should be 28/40/50/85 mm as per rating . All doors/opening are sealed with neoprene /EPDN gaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs along with DEF tank (as per OEM standards). There should be provision of protection and tripping of DG set for temperature greater than 50 degree centigrade. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. in open free field environment as per ISO 8528 part 10 duly certified by authorised agency etc. |
| 1100 | D) Instruments : Electronic / Mechanical governor, Manual & electric Start ,Batteries with battery charger, Electronic fuel system, advanced after treatment system (ATS), Exhaust gas recirculation(EGR) System along with Diesel oxidation catalyst(DOC) and Selective catalytic reduction (SCR) , supply module and DCU to control and monitor DEF. Engine instruments panel should have microprocessor based Genset monitoring system capable of displaying Running Hour, RPM, lubbrication oil pressure indication, lubrication oil temperature, battery charging indication, overspeed indication, fuel level etc. The control Panel should equipped with MCCB/ACB of suitable rating. |
| 1101 | E) Base frame and foundation : Both the engine and alternator shall be mounted on suitable base frame made of MS channel & coupled through a flexible coupling or close coupled which shall be installed on existing cement concrete foundation and vibration isolation arrangements as per recommendation of manufacturer. |
| 1102 | F) First filling of the FUEL Tank and DEF tank shall be done by contractor. |
| 1103 | G) DG set will be offered for Inspection and Testing at OEM's Works ( as per approved QAP ) in presence of Departmental Engineers .In case of 13 hour running testing at OEM's works, cost of actual consumables will be reimbursed. |
| 1104 | Note: 1. During the DLP, the contractor shall arrange for servicing of the DG set through authorized dealer of OEM, as per the manufacturers guidelines. The actual cost of consumables used during servicing will be reimbursed to the contractor by the end user department.2. Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. |
| 1105 | 500 KVA at 0.8 pf 415V 50Hz 3-ǿ with 8 Cylinder Engine |
| 1106 | 400 KVA at 0.8 pf 415V 50Hz 3-ǿ with 6 Cylinder Engine |
| 1107 | Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications (beyond 1.5 Mtr. length) including cutting, welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect. (Cost of Steel Structure for Exhaust pipe will be paid Extra). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1108 | 200 mm dia |
| 1109 | Supply, installation and testing of metal flexible coupling (bellow) of following dia required for horizontal length more than 3 mtr.as per standard of guide line of D.G. set company complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1110 | 200 mm dia |
| 1111 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1112 | Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including leveling, Dressing etc. as Required. |
| 1113 | SITC of 3Phase Input, 3Phase Output Online double conversion VFI-SS-111 IGBT based Rectifier & Inverter UPS with 0.99 Input power factor & unity Output factor(KVA=KW), having Inbuilt Isolation Transformer at Input, Phase balance of 120° ±1° (100% unbalanced load), input voltage & frequency range of 320-480V & 45-55 Hz and output voltage of 415V (+/- 1% for balanced & +/- 2% for unbalanced load) & output frequency of 50Hz +/- 0.1 Hz.UPS should have Inbuilt phase sequence corrector & protector both (UPS should correct the Input Phase reversal condition & shall not go to battery mode) and Input, output & Bypass breaker, UPS should have Inbuilt Static & maintenance bypass, Parallel kit, EPO, dust filter & conformal coated boards, Overall efficiency without transformer loss (93% for 10KVA, 94% for 20KVA & 30KVA, 95% for 40KVA& 60KVA) , Overloading on mains mode = 110% for 60 mins, = 125% for 10 mins, =150% for 1 min, THDi < 4%. UPS should have LED Panel with minimum 5 inch Intuitive Touch Screen LCD Displayy showing UPS status with other parameters like Input, Output, Bypass - Voltage/ Frequency,load%, Battery%. UPS should have protection from Input High / Low; Over Load;Short Circuit; Over Temperature and give audible alarms on Battery Mode;Low Battery;Fault;Over Load & Bypass Mode.UPS communication through RS485. SMF Batteries of 12V VRLA for 30 min back up with MS Rack having battery breaker with enclosure and necessary cable for UPS to Batteries Installation of 20 Mtrs.UPS should have feature to connect similer model & capacity with common battery bank.Operating Temperature of UPS 40 degree, relative humidity 0-95% (Non condensing), Noise level of 65dBA @1 mtr. UPS should have CE, ROHS, IEC62040-1,2&3 compliance and should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location Etc. as required. |
| 1114 | 20KVA UPS with 20160 VAH Battery |
| 1115 | Supplying, Installation, Testing & Commissioning of Electrical Driven fire fighting duty pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given as A, B, C, D, E, F, G and H. |
| 1116 | (A) End Suction / Horizontal Axially split casing volute type Single / Multi stage Centrifugal pump complete for delivery of below mentioned discharge and Head |
| 1117 | (B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal |
| 1118 | (C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head |
| 1119 | (D) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed 2900 / 1500 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect . |
| 1120 | ( E) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads. |
| 1121 | (F) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Physical presence of Department’s representatives. |
| 1122 | (G) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM |
| 1123 | (H)Suitable size Reinforced cement concrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1124 | 2850 LPM suitable for 70 Mtr Head Horizontal Axially split casing volute type Two stage, 1500 RPM |
| 1125 | 2280 LPM suitable for 56 Mtr Head End Suction Back pull type Single Stage, 2900 RPM |
| 1126 | Supplying, Installation, Testing & Commissioning of Diesel Engine Driven fire fighting duty pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given as A, B, C, D, E, F, G and H. |
| 1127 | (A) End Suction / Horizontal Axially split casing volute type Single / Multi stage Centrifugal pump complete for delivery of below mentioned discharge and Head |
| 1128 | (B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal |
| 1129 | (C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head |
| 1130 | (D) Heat Exchanger cooled Diesel Engine as per NFPA 20 developing suitable BHP for the below mentioned discharge at 1500 / 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump,Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter upto 10 M length (with LRB insulation & Alum. Cladding), with muffler, Diesel tank of 300 Lts capacity (made out from 2 mm thick MS sheet with filling Cap) with drain cock, Diesel level Indicator, Suitable MS angle iron stand for placing tank, first Filling of Diesel tank. |
| 1131 | (E) Diesel Engine Control comprising Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication, Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter, All standard relays and accessories for automatic operation of diesel engine System Controller in Existing Fire Fighting Control panel |
| 1132 | (F) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Physical presence of Department’s representatives. |
| 1133 | (G) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM |
| 1134 | (H) Pump to be placed on Suitable size Existing Reinforced cement concrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1135 | 2850 LPM suitable for 70 Mtr Head Horizontal Axially split casing volute type Two stage, 1500 RPM |
| 1136 | 2280 LPM suitable for 56 Mtr Head End Suction Back pull type Single Stage, 1800 / 2300 RPM |
| 1137 | Supplying, Installation, Testing & Commissioning of Electrical Driven fire fighting duty Jockey pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM suitable for automatic operation and consisting of following details given as A, B, C, D, E,F and G |
| 1138 | (A) Horizontal End suction Single / Multi Stage Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head |
| 1139 | (B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal |
| 1140 | (C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 2900 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect . |
| 1141 | (D) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads. |
| 1142 | (E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives. |
| 1143 | (F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM |
| 1144 | (G)Suitable size Reinforced cement concrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1145 | 180 LPM suitable for 70 Mtr Single Stage |
| 1146 | 180 LPM suitable for 56 Mtr Single Stage |
| 1147 | Supplying, Installation, Testing & Commissioning of Electrical Driven fire fighting duty Terrace pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM suitable for automatic operation and consisting of following details given as A, B, C, D, E, F, G and H. |
| 1148 | (A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head |
| 1149 | (B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal |
| 1150 | (C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect . |
| 1151 | (D) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads. |
| 1152 | (E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives. |
| 1153 | (F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM |
| 1154 | (G) Suitable size Reinforced cement concreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ) |
| 1155 | (H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1156 | 900 LPM with 35 mtr head |
| 1157 | Supplying, Installation, Testing & Commissioning submersible type dewatering pump of stainless steel casing and Noryl impellor of discharge and head given below complete with all accessories suitable for operation on 230 V, single phase/415 V /3 phase, 50 Hz. AC supply complete with starter for automatic operation including water level sensing device / float switch inter connection with submersible cable etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1158 | 180 LPM with 10 mtr head |
| 1159 | SITC of pressure switches of pressure range 3 to 15 Bar for Main, Jockey, Terrace pump and Diesel pumps, Etc. as Required ( Control Cable from Pressure switch to Panel to be Paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1160 | Providing and fixing 20/25 mm dia. (PN - 1.6, Type-S1, Flanged, ISI marked) air release valve confirming to IS - 14845 : 2000 with Double Flange isolating valve (pressure rating PN 1.6) complete with 1 no. Matching Flanges (Minimum 10 mm thick), nuts, bolts, washers, gaskets etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1161 | SITC of UL listed and FM Approved Polyethelene vane type water flow switch with actuation & delay mechanism for sensitivity in the range of 4 to 10 GPM and suitable for installation in following sizes of Sprinkler pipe for a Static pressure rating up to 250 PSI in cluding making connections, making hole in pipe for inserting the vane etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1162 | 80 mm Dia. |
| 1163 | 100 mm Dia. |
| 1164 | SITC of suitable Pressure release valve of 50 mm dia, of CI body, with pressure setting range 7-15 kg/sqcm, on discharge header / Air Vessel, complete in all respect etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1165 | Providing & fixing pressure transducer in M.S. Pipe line (pressure range 0 to 10 kg/cm2) suitable for 12 volts/24 volt DC. Including connection etc. as required. ( Control Cable from Pressure Transducer to Panel to be Paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1166 | SITC of UL listed / FM Approved Brass Test and drain valve assembly for sprinkler system comprising of 3-position ( off, test and Drain ) ball valves with drain orifice having K-factor 5.6 and maximum working pressure 300 PSI and Inbuilt sight glass etc. as required of following size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1167 | 50 mm Dia. |
| 1168 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C ' class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications including cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of required shade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1169 | 25 mm dia |
| 1170 | 32 mm dia |
| 1171 | 40 mm dia |
| 1172 | 50 mm dia |
| 1173 | 65 mm dia |
| 1174 | 80 mm dia |
| 1175 | 100 mm dia |
| 1176 | 150 mm dia |
| 1177 | 200 mm dia, 6.0 mm thick |
| 1178 | Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS 'C' class (Heavy) pipe conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications in Existing trench with cement concrete block as supports including cutting, welding etc & forged steel fittings like elbows, tees, tapers, reducer with cleaning,wrapping and coating of the pipe with 4 mm thick tar based polymaric corrosion protection tape including applying uniform coat of cold pipekot primer as per IS; 10221 for protection against corrosion complete in all respect. ( Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs. & Excavation of Trench and refilling of trench to be paid extra). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1179 | 80 mm dia |
| 1180 | 100 mm dia |
| 1181 | 150 mm dia |
| 1182 | Supplying and fixing cylindrical air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with flanged connection, Provision for 25 mm dia drain valve,air release valve,safety valve pressure gauge as required accessories and painting with two coats of Red Oxide and two coat of post office red enamel paint including The tank shall be installed on suitable vertical legs. The legs shall be provided with M.S. Angle of size 75 mm x 75 mm x 5 mm at the bottom. The legs shall be grouted in cement concrete foundation. as required. ( Air Release valve, Drain valve, PRV, Pressure Gauge shall be Paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1183 | Supplying and fixing cylindrical air vessel of continuous welded construction fixed at riser top made of 250 mm dia, fabricated out of 8 mm thick MS sheet, 1200 mm in height with flanged connection, Provision for 25 mm dia drain valve,air release valve,safety valve pressure gauge as required accessories and painting with two coats of Red Oxide and two coat of post office red enamel paint including The tank shall be installed on suitable vertical legs. The legs shall be provided with M.S. Angle of size 75 mm x 75 mm x 5 mm at the bottom. The legs shall be grouted in cement concrete foundation. as required. ( Air Release valve, Drain valve, PRV, Pressure Gauge shall be Paid Extra ). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1184 | Supplying and Fixing of PN 16 Flanged Y strainer fabricated out of cast iron body, SS 304 strainer with perforated screen with 3 mm. dia holes in existing MS / GI pipe complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1185 | 150 mm dia |
| 1186 | 200 mm dia |
| 1187 | Supplying and Fixing of PN 16 Flanged sluice valve with non rising spindle, bronze /gun metal seat confirming to IS:14846 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1188 | 150 mm dia |
| 1189 | Providing and constructing masonry chamber 90 x 90 x 100 cms inside with brick work in cement mortar 1:5 (1cement : 5fine sand) for water meter ,M.S. cover (6mmthick sheet with locking arrangement, 600 x600 with M.S. frame etc. all epoxy coated and R.C.C. top slab 1:2:4 mix(1 Cement : 2 coarsesand : 4 graded stone aggregate 20mm nominalsize) including necessary excavation, back fillingfoundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 20mmnominal size) leaving a pocket of 30x30 cmwith out concrete and filled with pebbles andinside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finishedwith a floating coat of neat cement and outside plaster finished rough complete. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1190 | Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1191 | 80 mm dia |
| 1192 | 150 mm dia |
| 1193 | 100 mm dia |
| 1194 | 200 mm dia |
| 1195 | Supplying and Fixing of PN 1.6 Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1196 | 50 mm dia |
| 1197 | 65 mm dia |
| 1198 | 80 mm dia |
| 1199 | 100 mm dia |
| 1200 | 150 mm dia |
| 1201 | 200 mm dia Gear Operated |
| 1202 | Supplying and Fixing of PN 16 Brass/GM Ball valves with screwed end, SS Ball including teflon tape etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1203 | 20 mm dia. |
| 1204 | 25 mm dia. |
| 1205 | SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1206 | 150 mm |
| 1207 | Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick), nuts, bolts, washers, gaskets, etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1208 | Single Headed with 75 mm Dia. Flanged Inlet |
| 1209 | Supplying and fixing orifice plate made of 6 mm thick stainless steel with orifice of required size in between flange & landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm2 complete with rubber gasket, GI bolts, nuts, washers etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1210 | Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A) 63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304 male and female couplings (IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. |
| 1211 | Supplying & fixing SS-304 Short Branch Pipe conforming to IS: 903:93 fitted with 20mm (nominal internal diameter) bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1212 | Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required. (A) Thermoplastic / Rubber Hose (B)20 mm dia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall. (D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1 through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1213 | With 30 m x 20 mm Thermoplastic hose as per IS:12585 Type-2 and Bursting pressure 42 Kg/sqcm |
| 1214 | With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969 and Bursting pressure 42 Kg/sqcm |
| 1215 | Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valve complete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following Ways. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1216 | 4 Way |
| 1217 | 2 Way |
| 1218 | Providing and fixing of 150 mm Dia. Flanged Gun Metal Fire brigade Suction hose coupling (draw out connection) for female coupling as per IS:902-1974 complete with Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required. |
| 1219 | Supply and Fixing of Cast iron body one side Flanged and other side strainer ball type foot valve with Reinforced rubber Nitrile rubber coated Ball including Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following Sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1220 | 150 mm Dia. |
| 1221 | Providing and Fixing of PN16 Resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 8.5 Kg/cm2 and test pressure 14 Kg/cm2 to provide relief from stresses at pipe including Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets, etc as required of following Sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1222 | 150 mm Dia. x 150 mm Oal |
| 1223 | Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheet Duly powder coated in red color externally and white internally with 6 mm thick glazed doors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1224 | Providing and Fixing of 15 mm dia Bronze quartzoid bulb type sprinkler heads with Maximum working pressure 11.6 Kg / Sqcm and suitable for 68 degree centigrade rating standard response (UL Listed) chrome plated complete in all respect of the following type. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1225 | Pendant/ Upright type |
| 1226 | Sidewall Sprinklers (ordinary) |
| 1227 | Extended Throw Sidewall type . |
| 1228 | Providing & fixing of UL listed 1.5 mm thick chrome plated Dual type MS Escutcheon plates fixed at junction of Sprinkler piping with the false ceiling. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1229 | Supply & Fixing of Fire Man's Axe with carbon steel head & rubber moulde handel usable upto 20 KV and confirming to IS :926 with length approx 0.4 M & weight 3.0 Kg. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1230 | Providing & fixing sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1231 | 700 mm Long |
| 1232 | 1000 mm Long |
| 1233 | 1200 mm Long |
| 1234 | 1500 mm Long |
| 1235 | Providing & fixing Stainless Steel pressure gauge with dial of 150 mm dia size and range 0 to 20 kg/sq.cm with 3 / 8 \\" BSP bottom entry , Ball valve , SS Syphon tube all fittings etc, duly calibrated before installation in MKS and FPS units, Accuracy Level +/- 1% including Making Drilling in Existing MS Pipe Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1236 | Fabrication, Supply, Installation, testing and commissioning of IP-42 Electrical control panel of cubical construction, floor mounted type fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 9 tank treatment process, cable alley, Interconnection with suitable size copper conductor cable / solid alum. strip strip having switchgear and accessories, mountings and internal wiring, earth terminals numbering etc. complete in all respect for main fire pump, Jockey pump and diesel pump set complete with following incoming and outgoings suitable for operation on 415 V 3 phase |
| 1237 | Incoming : 800 A, 50 kA, 4 pole MCCB, Ics = 100% Icu rating, Digital Voltmeter (0-500 V) with selector switch, Digital Ammeter (0-250A) with selector switch and CTs, LED type RYB Indicating lamp, ON, OFF Trip Indicating lamps, Aluminium TPN Busbar 1000 Amps. |
| 1238 | Outgoing Main Fire Pump: 250 A, 50 kA, 4 pole MCCB, Ics = 100% Icu rating, with suitable HP fully automatic DOL starter as per type-2 coordination with all accessories, internal wiring required for automatic operation, Digital Ammeter with selector switch and LED type ON, OFF Trip Indicating lamp, selector switch for local/remote, auto /manual/OFF operation - 2 Set |
| 1239 | Outgoing Jockey Pump: 125 A, 50 kA, 4 pole MCCB, Ics = 100% Icu rating, with suitable HP fully automatic DOL starter as per type-2 coordination with all accessories, internal wiring required for automatic operation, Digital Ammeter with selector switch and LED type ON, OFF Trip Indicating lamp, selector switch for local/remote, auto /manual/OFF operation - 2 Set |
| 1240 | Diesel Engine Control Panel : Comprising of Automatic / Manual selector switch and 3 attempts starting device, timers and relays as required push buttons, Start / Stop in Manual mode Indicating lamp for high / low lub. Oil pressure, High water temperature indication, Battery charger suitable for for 12V/ 24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, 0-20 A Dc ammeter, All standard accessories and relays for automatic operation of Engine |
| 1241 | System controller : Designing, supply Installation testing and commissioning of system controller to control operation main Electrical fire pump, jockey pump, Terrace pump in sequence as per requirement, consisting of relays, timers sensors, annunciation window for fault indication complete as required. |
| 1242 | SITC of UL 10th edition / EN54 / VDS certified Automatic Floating Sensitivity type Analog addressable Multi criteria (two optical/Smoke sensor to reduce false alarm) detector with mounting base & LED etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1243 | SITC of UL 10th edition / EN54 / VDS certified Rate of Rise Heat Detectors (Thermal Detectors):GRADE-I Analouge Addressable type Heat Detectors with solid state design with sensing element combination of fixed type and rate of rise of temperature mounting base & LED etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1244 | SITC of UL 10th edition / EN54 / VDS certified Analouge Addressable type Multi criteria (Heat & smoke) Beam detector along with interface module having a coverage area with a distance of min. 10 m and max. 100 m ,Operating temperature range: -20 C to +55 C, Response sensitivity of 40% , shall UL/EN54 certification including transmitter and receiver unit with mounting base & LED etc including the cost of all accessories, mouting arrangement Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1245 | SITC of UL 10th edition / EN54 / VDS certified Addressable type fault isolator with base for isolating shorted, dewired and loose circuits between two successive fault, isolators with automatic resetting arrangement etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1246 | SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED / FIRE Indication Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1247 | SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light, Loop Powered / Direct powered from FACP with sound level 90 dB and programmable from the panel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1248 | SITC of UL 10th edition / EN54 / VDS certified Addressable control (input/output) modules/ Relay Module for shutting down lifts, Hooters, AHU's, Acknoledgement of Sprinkler system with potential free contact monitoring Etc. as Required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1249 | SITC of Response Indicator for indicating the activation of the Remotely located Detector for Addressable type Detectors Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1250 | SITC of UL 10th edition / EN54 / VDS certified Microprocessor based inteligent, Analogue addressable,modular, expandable networkable loop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 125 detectors & devices with Loop length up to 1 KM as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, LCD/LED unit to indicate Fire / Fault Signal of individual unit, inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1251 | 2 - Loop Panel |
| 1252 | Add Extra for per Loop expansion beyond Two Loop |
| 1253 | Add Extra for Graphics User Inteface (GUI) Software for programming the fire detection and voice alarm system through FACP / PC. |
| 1254 | Add Extra for Workstation latest Intel® i5 processor, Intel Chipset motherboard, 08 GB RAM, 1 TB SATA HDD at 7200 rpm, with 2 x 4GB GPU type higher end Graphic card for H.265 compression technique with dual display ports/DVI/ HDMI port, Giga LAN Card, wireless Keyboard, wireless optical Mouse. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1255 | SITC of UL 10th edition / EN54 / VDS certified Active Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1256 | SITC of 2 way communication Fire Fighter's Telephone Jack.Complete as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1257 | SITC of 2 way communication Fire Fighter's Telephone Handset to make a call to the Main FACP from Telephone Jack Location Complete as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1258 | Supplying and drawing Fire Resistant flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1259 | 2 x 1.5 Sq.mm Unarmoured With Outer Sheath in Red Color |
| 1260 | 2 x 1.5 Sq.mm Armoured With Outer Sheath in Red Color |
| 1261 | SITC of PA system Operator Console of following wattage to be installed with Conventional fire alarm system complete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console , equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1262 | 1x 240 Watt |
| 1263 | 1x 350 Watt |
| 1264 | SITC 6 watt Speaker mounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1265 | SITC of 6W Ceiling Speaker with max SPL1M/1W 95dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W |
| 1266 | SITC of 6W Wall mount Speaker with max SPL1M/1W 92dB . Frequency response of 160Hz-20KHz. The speaker shoud have tappings at 6W/3W/1.5W |
| 1267 | Supply, Installation, Testing & Commssioning of of 8 Channel & 8 Zones IP based digital Voice Alarm controller capable of handling 4000 Watts. The voice alarm controller should be able to connect directly over Ethernet. It should have functions like the audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. The System shall be expandable type upto 2000 Zones. Individual Voice alarm controller should also have the following functions: . 255 Priorities . Time schedule broadcasts . 2 additional Channels for back up Amplifiers. . 8 trigger inputs/outputs . 8 AVC dgital input. . 5 Addressable Noise detectors per speaker zone. |
| 1268 | Supply, Installation, Testing & Commssioning of IP based Networkable 7 \\" capacitive touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions:. Built-in monitoring loudspeaker. Detachable goose-neck microphone. LCD touchscreen display. Audio input. Power Supply - 24VDC or POE. Provision for temporary recording function. Shortcut functions - one key broadcast, volume control etc. Shall be capable of monitoring & controlling multiple zones. |
| 1269 | SITC of 1X500W Class-D Amplifier, which can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection and High Efficiency Class D Power Amplifier, 500W, 100V/70 Output, with 100 - 240 VAC input and 24 VDC backup power Supply |
| 1270 | Supply and laying speaker cable of ollowing size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required. |
| 1271 | 1.5 Sq.mm |
| 1272 | Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability, including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1273 | Capacity 3.0 Kg. |
| 1274 | Capacity 4.5 Kg. |
| 1275 | Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1276 | Supplying and Fixing of Galvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Buckets including associated civil works etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1277 | Providing and fixing signages as per required content printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating with suitable colour combination (Glow in dark) with high intensity properties for indoor surface glow visibility not less than 6 hrs. in total darkness and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1278 | Double sided signage board |
| 1279 | Providing and fixing of Aluminium housing body self contained Rechargeable LED Emergency Light with required content and Size Approx. 300 mm x 180 mm, confirming to IS:9583 :1981with Ni-Mh / Ni - Cd Battery, 3 Hrs Back Up, Constant Current Charger, Input Voltage 230 V , 50 Hz including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1280 | Single sided signage |
| 1281 | Double sided signage |
| 1282 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Outdoor Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, seperated by a cross divider & protected by LSZH PVC outer jacket of UV resistant. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1283 | Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, Category 6A/Class Ea, U/FTP (Unscreened/Foiled Twisted Pair), 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, Unscreened and Aluminum Foil Sheilding of Individual pairs protected by a Low Smoke Zero Halogen (LSZH)(IEC 60332-1) Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 500 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1284 | Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1285 | Cat 6A, Sheilded Information Outlet |
| 1286 | Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1287 | Single Aperture |
| 1288 | Supply, Installation, Testing and Comissioning of Rack mounted 19\\" 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1289 | Modular Patch Panel Loaded with Cat -6A I/O |
| 1290 | Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1291 | Cat 6A, U/FTP (Unscreened/Foiled Twisted Pair) Patch Cord |
| 1292 | 1 Mtr |
| 1293 | 2 Mtr |
| 1294 | Supply, Drawing and Testing, of stranded Single mode (9/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1295 | 6 fiber |
| 1296 | 12 Fiber |
| 1297 | 24 Fiber |
| 1298 | Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm (OS1/OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2), should have length of min 1.5m, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, Should be delta IL < 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirments.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1299 | Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1300 | Single Mode Patch Cord 3 Mtr. |
| 1301 | Supply, Installation, & Testing of 19\\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1302 | 6 Ports |
| 1303 | Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1304 | 12 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 1305 | Supply & Installation of IP-20 & IK-08 , UL Listed Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,Vertical Mounting Rail 1.6 MM with 'U'Marking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, Set of 75 mm height 4 castors, 2 of which have brakes, Accessories like: 5 Nos of 19\\" 1U Horizontal Cable manager, 2 Nos of vertical cable managers, 1 no. Keyboard Tray, 4 Nos of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 2 No of 19\\" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1306 | 42 U Rack with Width 800 mm & Depth 1000 mm with 3 no. Heavy Duty Sliding Drawer |
| 1307 | Supplying, installation, Testing and commissioning of following capacity 8 port Non POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1308 | Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1309 | Supplying, installation, Testing and commissioning of following capacity 24 port POE Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snooping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.0Ǫ,Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snooping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.0P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.0p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.0ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1310 | Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.(For Each SM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class. |
| 1311 | 10 G SFP + Single Mode/Multi Mode |
| 1312 | Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect. |
| 1313 | Fiber Fusion Splicing with OTDR/OLTS Testing of Fiber Single/ Multi mode (per splice) of glass Fiber Optic Cable including jointer box and cleaning the cable and making splice as per standard practice complete in all respect. |
| 1314 | Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High density use having features and specifications etc. as mentioned here under- WiFi6 802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, WPA/WPA2/WPA3TM Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client ., Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 1315 | Supplying, Installation, Testing and commissioning of Outdoor Wireless Access Point having features and specifications etc. as mentioned here under - WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, 4 x internal antennas, the transmission coverage of shall be minimum 80 meters in radius, AP should have transmission power minimum of 22 dBm, The AP shall provide a minimum of 29 dBm EIRP for both 2.4 GHz and 5 GHz frequencies. Field deployment shall be with EIRP as per regulatory guidelines, AP shall have dual-band Omni-directional Antenna, either internal or external. Field deployment shall be with EIRP as per the WPC guideline, WPA/WPA2/WPA3TM Personal/ Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA- PSK/WPA2-PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, IP68 water/dustproof standard, 6KV Surge Protection; 4KV ESD Protection (contact), 6KV (air), Operating ambient temperature (-5~50 °C), Grounding point support, IEC 60601-1-2 EMC Medical Electrical Equipment Testing and Certification, EN50121-1 & EN50121-4 for Wireless Application. Certifications:MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with additional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role- Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication. OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. as required. |
| 1316 | SITC of IP Based 5MP Dome camera: 1/2.8\\" or larger Progressive Scan CMOS Sensor with resolution:(2560 x 1920) @30 fps. Should Support H.264, H.265, MJPEG, Quad/Triple streaming profiles, Frame rate upto 1-30 fps, 120dB WDR, 2DNR/3DNR, BLC. Camera should support Open standard to support ONVIF (PROFILE S, PROFILE G, PROFILE T), 1/1 Audio In/Out or better and 1/1 Alarm In/Out or better, onboard storage upto 512GB (SD card not included). The camera supports advanced Video Analytics (VA) including motion detection, and alarm should be trigger on Tampering, Network disconnect, IP address conflict. CCTV should have password protection, privacy mask, IP address filtering, Metal Housing, Vandal-proof housing, IP67, IK10, DC 12V & PoE, Complete with Junction box for cable management. Operating Conditions within -20°C to 60°C or better. The MAC address of Camera/NVR must be registered in the name of OEM. Regulatory approvals include FCC, BIS/UL, CE. CCTV cameras must be BIS Registered Cyber Security Certified by STQC as per IoTSCS and meet the Essential Requirement (ER) issued by MeitY for security. The CCTV OEM should have its service/ support center in Rajasthan. |
| 1317 | Varifocal 2.8mm to 12mm lens or better with 40 Meter IR Range or higher |
| 1318 | SITC of IP Based 5MP Bullet camera: 1/2.8\\" or larger Progressive Scan CMOS Sensor with resolution:(2560 x 1920) @30 fps Should Support H.264, H.265, MJPEG, Quad/Triple streaming profiles, Frame rate upto 1-30 fps, 120dB WDR, 2DNR/3DNR, BLC. Camera should support Open standard to support ONVIF (PROFILE S, PROFILE G, PROFILE T), 1/1 Audio In/Out or better and 1/1 Alarm In/Out or better, onboard storage upto 512GB (SD card not included). The camera supports advanced Video Analytics (VA) including motion detection and alarm should be trigger on Tampering, Network disconnect, IP address conflict. CCTV should have password protection, privacy mask, IP address filtering, Metal Housing, Vandal-proof housing, IP67, IK10, DC 12V & PoE, Complete with Junction box for cable management. Operating Conditions within -20°C to 60°C or better. The MAC address of Camera/NVR must be registered in the name of OEM. Regulatory approvals include FCC, BIS/UL, CE. CCTV cameras must be BIS Registered Cyber Security Certified by STQC as per IoTSCS and meet the Essential Requirement (ER) issued by MeitY for security. The CCTV OEM should have its service/ support center in Rajasthan. |
| 1319 | Varifocal 2.8mm to 12mm lens or better with 50 Meter IR Range or higher |
| 1320 | SITC of 4/5 MP (minimum 2560X1440) IR Dome PTZ with minimum 36x or more Optical Zoom and minimum 16x or more Digital Zoom, 1/ 2.8” or larger CMOS Sensor, WDR -120dB, and, PAN range 360 degree, Quad/Triple streaming profiles, Frame rate upto 30 fps or more, Video Compression -H.265/H.264/M-JPEG, IR LEDs with IR Distance of 250 mtr or more, Camera should support Open standard to support ONVIF (PROFILE S, PROFILE G, PROFILE T), 1/1 Audio In/Out or better and 1/1 Alarm In/Out or better, onboard storage upto 512GB (SD card not included). The camera supports advanced Video Analytics (VA) including motion detection and alarm should be trigger on Tampering, Network disconnect, IP address conflict. CCTV should have password protection, privacy mask, IP address filtering, Metal Housing, Vandal-proof housing, IP67, IK10, DC 12V & PoE, Complete with Junction box for cable management. Operating Conditions within -20°C to 60°C or better. The MAC address of Camera/NVR must be registered in the name of OEM.Regulatory approvals include FCC, BIS/UL, CE. CCTV cameras must be BIS Registered Cyber Security Certified by STQC as per IoTSCS and meet the Essential Requirement (ER) issued by MeitY for security. The CCTV OEM should have its service/ support center in Rajasthan. |
| 1321 | SITC of 64CH NVR for 8 MP cameras with minimum 8 SATA HDD Support with minimum 128 TB capacity (Hard Disk Not Included), minimum 1 HDMI output port, Video comression - H.265/H.264/JPEG, 1/1 Audio In/Out, Preview Capability - Upto 4K, Playback: 16-channel simultaneously. NVR should support minimum 1024 Mbps throughput bandwidth (512 incoming bandwidth), ONVIF compliance (Profile S/G/T). Recording resolution up to 4K/8MP, minimum 2 USB Ports, minimum 1 Ethernet Ports (RJ-45) 10/100/1000Mbps, RAID 0/1/5/10 or better. The system shall operate in 0°C to +50°C or better with BIS, FCC, CE. The CCTV OEM should have its service/ support center in Rajasthan. |
| 1322 | SITC of 3.5\\" 4TB internal HDD for cctv recording ,capable for 24x7 operation, hdd rpm capacity shoud be 7200 rpm or better, Buffer should be 512 MB as required of following size. |
| 1323 | SITC of following diagonal size professional Display, 4k Resolution, Brightness(Typ.) 440 nit and above , Contrast Ratio-2000:1 and above, Viewing Angle(H/V)-178/178, Response Time(G-to-G) 8ms, Input: RGB- Analog D-SUB, Video- HDMI 2.0 (2), HDCP- HDCP 2.2, Audio- Stereo mini Jack, USB- Only F/W upgrade, Outputs: RGB- DP1.2(Loop- out), Audio- Stereo mini Jack, External Control- RS232C(in/out), RJ45, External Sensor Detachable type(IR Ambient). Operation Hour 24/7. mounting bracket etc. as required. |
| 1324 | SITC of IP-PBX which is IP at its core and act as a Unified Communication System with IP switching technology and 100% non-blocking, configured for below mentioned. The system should be IPV6 ready, should have VoIP and Voice mail at its core i.e. these modules should be mountable on the CPU. The system should be Q Sig Ready, inbuilt Auto-attendant facility, Returned Call to Original Caller (RCOC), CLI based DISA (Mobile Extension)System, Should support SNMP manager for managing and monitor network elements, audit network usage and detect network faults, should support SIP over TLS and SRTP, minimum 2 Gigabit Ethernet ports for LAN and WAN, built-in multi-party conferencing facility with 21 party in a single conference, minimum one RS232 ports for SMDR/PMS/CAS Interface. The System have have capability to also act like Universal Media Gateway when required. The System should have facility of Conversation recording on Analog/Digital/IP ports as well as on Mobile SIP Smartphones, UC Client application for Android, iPhone and on Windows PC. Power supply should be inbuilt and SMPS type with input ranges from 100 – 240 V AC, 47-60 Hz OR 48VDC +/- 15%. The system must have Certification: TEC, CE, FCC, ROHS. |
| 1325 | 128 analogue extensions, 08 PSTN Trunk Port, 30 Channel SIP PRI, 08 Digital Port, 15 IP User License, 5 IP Softphone/mobile user license, 08 VoIP Channel License along with 8 port Voice Mail expandable upto minimum 224 TDM ports and minimum 500 SIP/IP users without any add-on CPU or chassis/hardware platform. |
| 1326 | SITC of Line Card for required Analog / Digital / CO Extensions. compatible to the IP PBX as required. CLI based Telephone Instrument, with Caller ID, 2 way /Hands free speaker, 16 Digit LCD Display, Adj. volume |
| 1327 | SITC of Type-I IP Phone with 128 x 64 or better –pixel Graphical LCD , Extended SIP Protocol, LED for Call and message wait Indication, 3 Feature Keys:Headset, Mute, Hands-free speaker phone, 4 Context Sensitive Keys, 2 Line keys with Function such as navigation, Call Appearance , feature status, Volume Control Keys, 2 X RJ45 10/100/1000 Mbps Ethernet Ports, Power Over Ethernet (IEEE 802.3af), minimum one RJ9 Handset port, one RJ9 Headset port & Power Supply - 5VDC 0.6A, Power consumption - 1Watt, 0°C to 45°C or better, Certifications: TEC, CE, FCC, RoHS. |
| 1328 | SITC of Machine Room / Machine room less passenger / Stretcher / Bed elevator confirming to IS:17900 - part I & II and having specifications as per A, B, C, D, E, F, G, H and I |
| 1329 | A. Doors : Centre/Telescopic opening Doors of 2100 mm height with frame made from Stainless steel grade AISI 304 2B solid (non-cladded) sheet of 1.5 mm thick in Hairline / Moonrock / honeycomb finish for car and all landing doors, The lift doors shall have 2 hour fire rating and 8 lacs cycle per year tested (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with key holes and full length infared curtains and unlocking facility from outside. |
| 1330 | B. Car : Lift car enclosure as per available lift well size and height 2300 mm made from Stainless steel grade AISI 304 2B solid (non-cladded) sheet of 1.5 mm, thick with Hairline / Moonrock / honeycomb finish with frame made from MS platform, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower for ventilation, vinyl flooring or 20 mm recess for granite, Grab bars, mirror, emergency light ,emergency stop device, emergncy alarm, mechanical door safety, facility of auto/attendent mode. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, audio-visual alarm, Door closing/opening button, The lift car interior design shall be done as per the directions of engineer in charge. |
| 1331 | C. Controller : Microprocessor/ PLC with VVVF and Regenerative Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories in IP-54 1.5 mm thick SS304 Enclosure |
| 1332 | D. Motor : Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, main hoisting flat coated steel belt / rope . OSG rope, travelling cable, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. |
| 1333 | E. LOP : LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings |
| 1334 | F. Mechanical parts : adequate size 'T' section guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. |
| 1335 | G. Other Features: Automatic rescue device with required SMF VRLA Batteries, Mechanical manual rescue device, Fireman controller having fireman switch at fire Landing, rechargeable battery operated LED emergency light in the car and along with alarm switch, Mechanical/Electronic over speed governor, Spring buffers/PU Buffers, voice annunciator, provision for CCTV, automatic car light and ventilation, false car call cancelling, Lanterns at landing, |
| 1336 | H. Minor Civil works: such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine, temporary barricades with caution boards at each landing to prevent accident during execution. |
| 1337 | I. AMC & statutory permission : Comprehensive AMC of lift for 5 years including obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Lift Inspector (if required) |
| 1338 | Lift with travelling speed 1.0 Mtr./ Second and 5 stops |
| 1339 | 20 passengers/1360 Kg , Stretcher/Hospital Elevator with Landing Door 1100/1200 mm wide |
| 1340 | Lift with travelling speed 1.0 Mtr./ Second and 6 stops |
| 1341 | 20 passengers/1360 Kg , Stretcher/Hospital Elevator with Landing Door 1100/1200 mm wide |
| 1342 | Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having 100% hermetically sealed inverter type Scroll Compressor(s) with and minimum two compressors along with two Condensing fan, above 14/18 HP modules, microprocessor based Controller, Side / top discharge type condensing unit(s), with R-410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The EER at 100% load with AHRI conditions shall not be less than 3.5 and Including OEM supplied Piping connection Kit etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1343 | Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down valve in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1344 | 2.4 TR |
| 1345 | 3.2 TR |
| 1346 | Add Extra for OEM make Wireless remote in place of Wired remote including receiver as required. |
| 1347 | Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down valve in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1348 | 1.2 TR |
| 1349 | 1.65 TR |
| 1350 | Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down valve in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1351 | High Static Ductable units ( 78 pascal or above external static pressure) |
| 1352 | 8.0 TR |
| 1353 | Supply, installation, testing & commissioning of Group controller for monitoring the status and working condition of all indoor and outdoor units, The controller shall act as an advanced air conditioning management system to given complete control of VRV/VRF air conditioning equipment with Starting/stopping of air-conditioning as a zone or group of individual units. Temperature setting for each Indoor units of zone, Switching between temperature control modes, switching of the fan speed and direction of airflow, enabling/disabling of individual remote controller operation, Alarm code display in case of any problem. It shall be able to control up to 64 (max. 512 if required) number of Indoor units. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1354 | Add Extra for extenders/adaptors compatible with central controller to enable the controller to work with 128 IDU's |
| 1355 | Supplying and installation of high-pressure grade required size OEM make copper connection Y or T Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1356 | Gas charging of VRF/VRV system with R410A refrigerant gas. Before gas charging system shall be flushed with high purity Nitrogen Gas to remove carbon content, dirt particles to make sure that there is no chance of mixing any impurity with Refrigerant Gas. Thereafter System shall be tested with Nitrogen Gas at 1.5 Times of working pressure of R410 Refrigerant Gas to ensure leakproof system. Whole system shall be Vacuumed up to 500-micron level which ensures the zero-moisture content level in piping to ensure better cooling efficiency and long life of the system. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1357 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1358 | Armoured |
| 1359 | 2 core x 2.5 Sq.mm |
| 1360 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1361 | 20 mm |
| 1362 | 25 mm |
| 1363 | 32 mm |
| 1364 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia |
| 1365 | 50 mm dia per running inch length |
| 1366 | 100 mm dia per running inch length |
| 1367 | Providing and making wall openings in existing stone / Brick masonary partition wall complete with all requited T & P , Scafolding and providing lintel of required size and strength, repairing ,plastering and cleaning the site debrises as required. |
| 1368 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1369 | SITC of circular type Inline fans for ventilation including motor, with forward curved Direc driven SISW fan, motor and drive suitable for 220 ± 10% volts, 1 phase, 50 Hz A.C supply, thermal overload protection, including making connections, ancilliary structure to suspend it from beam/slab, vibration isolator etc. as required of following sizes. (cost of canvass connection to be paid extra ) |
| 1370 | 200 cfm to 500 cfm at 15 mm static |
| 1371 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from aluminium sheet conforming to IS:737, Grade 31000 fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports , angle , expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1372 | 0.60 mm |
| 1373 | 0.80mm |
| 1374 | Supplying, installing, testing and balancing of extruded Aluminium Powder coated supply/return Grilles with fixed bars at front having 0 / 15 / 30 / 45 degrees deflection as required. with Flange size 20 mm with rounded edges including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1375 | P & F of Fire retardent flexible canvass connection made of fibreglass weave having silver grey silicon rubber coating, of height 200 mm with sufficient fold to avoid transmission of vibration with GI frame ,Gasket Nut Bolts for air cooling Plants/AHU/FCU etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1376 | Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1377 | 2.0 TR ISEER not less then 3.8 |
| 1378 | SITC of Grid interactive Solar Photovoltaic Power Plant of required capacity having specifications as per A, B, C, D, E, F and G |
| 1379 | A. Solar Photovoltaic module : MNRE approved and ALMM listed, SPV module of capacity 580 Wp or above, Anodized Aluminium Alloy Framed Topcon N- type Bifacial, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. , 2 mm Low Iron ARC semi-tempered glass, IP-68 PPL Junction box, 4.0 sq.mm cable with MC4 solar connector, conversion efficiency shall not be less than 21.0 % on STC, performance warranty for their output peak watt capacity > 90 % at the end of 10 years and > 80% at the end of 25 years. |
| 1380 | B. Inverter / PCU : MPPT integrated, IGBT/MOSFET based and microprocessor/ DSP controlled Power Conditioning Unit (PCU) of AC nominal power output rating equal or greater than the required KWp of the module in IP-65 Enclosure, of 250-1500 V DC Input voltage range and 400 V AC, TPN, 50Hz +/- 2.5 Hz, Efficiency > 97%, THD < 3%, Overloading capacity > / = 10%, remote monitoring facility and PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. |
| 1381 | C. Module mounting structure : MMS Steel shall be as per latest IS 2062:2011 and galvanization of the mounting structure shall be in compliance of latest IS 4759, All bolts, nuts, fasteners shall be hot dip galvanized, MMS shall be designed and installed to withstand the speed for the wind zone of the location with factor of safety >1.5, STAAD report of structure to be submitted |
| 1382 | D. Array Junction Box / DCDB : IP 65 AJB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. DC fuses with SPD type-II/MOV type surge arrester to be provided. |
| 1383 | E. ACDB : IP 65 ACDB / Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. MCB/MCCB with SPD type-II/MOV type surge arrester to be provided. |
| 1384 | F. Earthing and Lightning protection: The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors (LAs). as per NFC17-102:2011/IEC 62305 standard and three no. of Earthing with suitable size earth conductor |
| 1385 | G. Solar meter and Cable : Laying of array cables to PCU/ DCDB unit along with supplying & fixing of necessary GI raceways/MS conduit lugs and suitable size aluminium armoured cable from ACDB to Electrical panel (up to 50 Mtr.) Discom approved solar meter (Direct or CT operated) with suitable size IP65 enclosure or MIP Box with CT |
| 1386 | 5 KWp |
| 1387 | SITC of 11 kV Outdoor Package Sub-Station Factory Assembled and Factory fitted by RMU & LT Switchgear OEM of Following Transformer & ACB Rating and consisting of A, B, C, D & E (Cost of RCC Foundation / Steel Structure to be paid Extra). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1388 | A) HT Compartment: Ring Main Unit 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, non-extensible, Ring main unit consisting of 2 nos. manually operated Load Break Switch and 1 Nos. 630 Amp Vacuum Circuit Breaker (manually operated) with Copper busbar in SF6 insulated stainless steel enclosure of thickness 2.5mm Non ferrite nonmagnetic type 304 grade. Interconnection between HT switchgear and transformer by Suitable Sized Aluminium un-armoured HT XLPE Cable. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The Gas tank of the RMU should be internal arc tested for 20KA for 1Second. VI should be RMU Manufacturer’s own make.- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB feeder- 1 No. Manometer- 1 No. Fault Passage Indicator for each Load Break switch. |
| 1389 | B) Transformer: 11kV/433V, 3phase,50 HZ, Copper wound Dry Type outdoor type step down transformer having delta connection on primary side and star connection on secondary side complete with all modern fitting as given in the specification , off load tap changer (-10% +5% in the step of 2.5%) etc. as required as per compete with losses as latest ECBC Standards , Class H with 115 Deg temperature rise allowed .- One No. Winding Temperature Indicator with Alarm and trip Contc |
| 1390 | C) LV Compartment: Incoming cum Outgoing with One number Fixed type 4 pole 415V ACB with molded case construction having breaking capacity 50KA with Ics = Icu = Icw (1 sec) = 50KA with microprocessor release for over current, earth fault & short circuit protections. Interconnection between Transformer & LT switchgear using Aluminum Bus bars of ACB Current rating with heat shrinkable colored sleeves. |
| 1391 | D) The Outdoor enclosure shall be made of 1.5 mm mm thickness Galvanized Sheet Steel tropicalised to meet Indian weather conditions including all the partition Sheets & doors. The enclosure base shall be of 4.0 mm thickness Hot Dip Galvanized Sheet Steel. The entire Package Substation shall be Factory Assemble & Factory Fitted. The enclosure shall have IP54 degree of protection for HT & LT switchgear compartment IP-23 degree of protection for Transformer compartment. The Enclosure should be type tested for Internal Arc fault test to the tune of at least 21 KA for 1 second adhering to as per latest IEC 62271- 202. The offered enclosure should be type tested for K10 class temparature raise. TTR to be submitted. The enclosure exterior shall be powder coated. The compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Internal earthing connections by using 50x6mm GI Strips. Vacuum Interrupter, RMU, Transformer,LV switchgear, Outdoor enclosure should be of same make for better life cycle optimization. |
| 1392 | E) All the Type test certificates of RMU, Transformer & LT Switchgear will be provided by Manufacturer and factory Tests of Package Substation as per OEM's QAP in it's own Manufacturing facility shall be witnessed by department Engineer virtually / Physically |
| 1393 | Transformer Capacity 500 KVA, ACB Rating 1000 Amps. |
| 1394 | DDesign, Manufacturing, Supply and Erection of hot dip galvanised, polygonal High Mast pole (Design Conforming to PLG 7, IS- 875 (Part-3):1987, Galvanizing confirming to BSEN ISO 1461:1991 and material confirming to BS EN 10025, S355, IS:2062) with fixed head frame suitable for mounting suitable No of light fittings of 1500W -1800W to achieve the required Light level as per the tender requirement. sustain Wind Speed of 47Mtr/s complete with all accessories as required and including Construction of shallow foundation with M25 grade concrete for the high mast considering the safe soil bearing capacity at site as per site SBC report with all materials and labour. The required height of the high mast pole from base upto bottom of head frame shall be 45 Mtrs. The High Mast pole has to be designed for base wind speed 47m/s relating to wind load on structure and also confirm BSEN 40 -1:1992 relating to general construction, special steel foundation bolt as required along with nuts, washers,anchor plate and common template. Each pole must be provided with winch, thread and motor for man rider unit. Each high mast pole must be provided with GI lightning arrester mounted at the top of high mast pole fabricated by OEM only. Each high mast pole must be provided proper earthing system of itself and light system as required. Complete item shall be as per specifications as required and as per direction of department. Mast head frame should be in aesthetic look as per design approved by department .All Quality Test report from NABL should be submitted by contractor. Make Bajaj, Valmont, Transrail , Musco(USA) etc and make is to be approved by department. |
| 1395 | Design, Manufacturing ,Supply, installation, testing and commissioning of electric man-rider lift system suitable for safe maintenance and servicing of high mast lighting towers. The lift system shall be of external wire rope driven type designed to serve multiple high masts and shall include high strength galvanized steel wire ropes, electric motor with reduction gearbox, lifting cage, guide system and necessary mechanical components. The lift shall be equipped with essential safety features including overload protection, emergency braking system, mechanical safety locking arrangement, limit switches and manual emergency lowering facility. The system shall operate on 415 V, 3 phase, 50 Hz power supply and shall be provided with a suitable control panel for operation and protection. The entire system shall be designed to ensure safe and reliable access to the high mast platform for maintenance personnel.All Quality Test report should be submitted by contractor. Make Bajaj, Valmont, Signify ,Transrail, Musco(USA) etc and make is to be approved by department. |
| 1396 | Supply, Installation, Testing and Commissioning of Energy efficient LED Sports Arena Luminaires, each with system wattage1500-1800W with CCT 5700K +/-355K as per ANSI), Light quality as per International Broadcasting standards meeting minimum Color Rendering Index as well as Television Lighting Consistancy Index values 90 or better , The Luminaire housing should be single piece made of Aluminum with uniquely designed thermal management for rapid thermal healing through passive cooling method with no dependency on active cooling devices. (No active cooling devices/fans allowed) and powder coated with corrosion resistance matt finish powder coating . The LED Chip shall be of SMD type and Ceramic Base High Power LEDs (COB type LED chip is not acceptable. Multichip LED arrays is not acceptable) of reputed Makes of Nichia (Japan)/ CREE(USA) / Lumileds(Netherlands) Only. Individual LED wattage shall be >=1W and <=4 W. The light engine should use Metal Core PCB with high grade aluminum (AL5052) and should have a thermal conductivity of >2W/mK. Luminaire must have minimum Ingress protection of IP66 and Impact Resistance of IK08. The Luminaire should be equiped with UV stabilized Injection Molded Polycarbonate lens front Cover to have high efficient glare free optics with no yellowing with respect to time (Glass cover Not allowed). The Luminaire Housing or Optical Cover should be equipped with OEM logo engraved or embossed (Stickering/Screen printing not acceptable) . |
| 1397 | The Luminaire shall be available in different beam angles as per requirement of design and to meet required lighting parameters and a lux level warranty as per tender. The luminaire shall employ remote Driver tray at the bottom of the mast with Following features: single channel Ultra High Efficiency Potted constant current Isolated programmable and IP66/IP67 rated LED driver that operates from 176-305 Vac input with power factor > 0.95, 0-10V/PWM/3-Timer-Modes Dimmable type driver . Compact Metal Case with Excellent Thermal Performance, Full Power at Wide Output Current Range (Constant Power), Adjustable Output Current (AOC) with Programmability. Output Lumen Compensation feature, All-Around Protection: To ensure trouble-free operation, inbuilt protection against input surge, input under voltage, input over voltage, output over voltage, short circuit, and over temperature. Output Current Ripple at < 200 Hz (pk-pk) should be less than 2%, Input Surge Protection: DM 6kV, CM 10kV. Quantity of Luminaires as per the OEM design to meet the desired as per International Broadcasting standards lux levels as per the tender requirement.The fixture shall confirm to relevant BIS standards and bear trade mark certificate from the Manufacturer. Manufacturers Word Mark and it's Name should be Engraved/ Embossed or Screen printed on the housing. Product level should display the system lumens information along with the wattage. The OEM must ensure that their products are tested for compliance, through their in house laboratory equipped with \\"C\\" type photogonio meter and accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and test methods specified in BIS 10322 for Led luminaires.OEM shall provide LM-80 reports based on the methods developed by IES (Illumination Engineering Society). Heat Sink of aluminium housing should be such that LED junction temperature shall not rise above 90 degree C. Make Bajaj, signify, Lighting Technologies(LT), Musco(USA), Osram etc and make is to be approved by department . |
| 1398 | Supply, Installation, Testing & Commissioning of single dome LED Aviation Obstruction Light (2 Nos per mast) including all required mounting frame for retrofitting arrangement, etc complete in all respect as per direction of Engineer-in-Charge. |
| 1399 | SITC of outdoor type stadium high mast power panel integrated with remote driver rack for operation of LED sports lighting fixtures. The panel shall be designed for outdoor installation and shall be provided with a weatherproof CRCA sheet steel enclosure with epoxy powder coated finish and minimum IP55 protection. The panel shall have separate compartments for power components and driver units to ensure proper ventilation and heat dissipation. It shall include necessary protection devices such as MCCB or MCB, contactor based switching arrangement, timer and manual control system, surge protection devices, and internal wiring with suitable terminal blocks. The panel shall also accommodate the remotely located LED drivers and shall be provided with adequate space for cable termination and maintenance access.complete as per direction of Engineer-in-Charge. |
| 1400 | Supply Installation, testing and Commissioning of DMX Based control system which includes the below Items as per the specifications (a)Artnet / DMX console supports up to 4,096 parameters, allowing control of fixtures across up to 25 DMX universes through 10 motorized faders and 5 dual encoders. It features 6 physical DMX outputs, along with MIDI In/Out, Timecode In, and Ethernet for networked lighting control. Designed for professional use, it delivers real-time performance and powerful processing in a compact, road-ready form. (b)2 PORT Node supports up to 1,024 parameters, enabling control of fixtures across 2 DMX universes. features 2 configurable DMX ports (In/Out), robust Ethernet connectivity, and seamless integration through Artnet Protocol. Compact and rugged, it is ideal for expanding DMX output in professional lighting setups with reliable network-based control. (c)DMX SPLITTER - DMX splitter and repeater that amplifies and distributes DMX signals across multiple outputs with RDM support , prevents signal interference, and enables star topology connections beyond the 32-device limit. Electrical isolation up to >1000v , Din Rail Mounted Powered By DC power supply , Screw Terminals for DMX output and input and with Link Terminator enabling seamless Operation (d)DMX cable with 120 ohms impedance with FR+ UV PVC insulation, Suitable for outdoor application, Jacket Grey Color, Drain wire added with shield and 22awg pair color with 120-ohm Impedance across each core (e)Ofc Cable For Communication 6 Core ensures superior signal transmission with minimal loss, ideal for high-performance lighting and audio applications (f)DMX Converter suitable for each existing LED Luminaire driver plate for integrating with the DMX System (g)21’ MONITOR (h)OFC TO ETHERNET CONVERTOR(i)PVC TERMINATION BOX WITH PIG TAIL CONNECTORS( j)CAT6 PATCH CHORDS complete in all respect as per site requirement.(for all mast) |
| 1401 | SITC of Machine Room / Machine room less passenger / Stretcher / Bed elevator confirming to IS:17900 - part I & II and having specifications as per A, B, C, D, E, F, G, H and I |
| 1402 | A. Doors : Centre/Telescopic opening Doors of 2100 mm height with frame made from Stainless steel grade AISI 304 2B solid (non-cladded) sheet of 1.5 mm thick in Hairline / Moonrock / honeycomb finish for car and all landing doors, The lift doors shall have 2 hour fire rating and 8 lacs cycle per year tested (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with key holes and full length infared curtains and unlocking facility from outside. |
| 1403 | B. Car : Lift car enclosure as per available lift well size and height 2300 mm made from Stainless steel grade AISI 304 2B solid (non-cladded) sheet of 1.5 mm, thick with Hairline / Moonrock / honeycomb finish with frame made from MS platform, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower for ventilation, vinyl flooring or 20 mm recess for granite, Grab bars, mirror, emergency light ,emergency stop device, emergncy alarm, mechanical door safety, facility of auto/attendent mode. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, audio-visual alarm, Door closing/opening button, The lift car interior design shall be done as per the directions of engineer in charge. |
| 1404 | C. Controller : Microprocessor/ PLC with VVVF and Regenerative Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories in IP-54 1.5 mm thick SS304 Enclosure |
| 1405 | D. Motor : Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, main hoisting flat coated steel belt / rope . OSG rope, travelling cable, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. |
| 1406 | E. LOP : LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings |
| 1407 | F. Mechanical parts : adequate size 'T' section guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. |
| 1408 | G. Other Features: Automatic rescue device with required SMF VRLA Batteries, Mechanical manual rescue device, Fireman controller having fireman switch at fire Landing, rechargeable battery operated LED emergency light in the car and along with alarm switch, Mechanical/Electronic over speed governor, Spring buffers/PU Buffers, voice annunciator, provision for CCTV, automatic car light and ventilation, false car call cancelling, Lanterns at landing, |
| 1409 | H. Minor Civil works: such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine, temporary barricades with caution boards at each landing to prevent accident during execution. |
| 1410 | I. AMC & statutory permission : Comprehensive AMC of lift for 5 years including obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Lift Inspector (if required) |
| 1411 | Lift with travelling speed 1.0 Mtr./ Second and 2 stops |
| 1412 | 8 passengers/544 Kg , Landing Door 800 mm wide |
| 1413 | SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325 IP55 with class `H' insulation. Motor shall be of high temperature resistance \\"Class H Smoke Spill\\" 250° C for 2 hrs. Fan shall be EN 12101-3 Certified & CE/UL Listed for high temprature. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemisperical reverberant room conditions for Normal mode Fans and noise level should not be more than 90 db @ 3 m distance when measured in hemisperical reverberant room conditions for Emergency mode Fans. Fan shall have all provision for start on emergancy signal from fire alarm panel including ancilliary structure to suspend it from beam/slab, vibration isolator etc. as required of following sizes. (cost of canvass connection to be paid extra ) |
| 1414 | 5000 cfm to 15000 cfm with static 30 mm |
| 1415 | Supply , Installation, Testing and Comissioning of factory fabricated SMACNA standard ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade of 120GSM (both side inclusive) & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1416 | 0.60mm |
| 1417 | 0.80mm |
| 1418 | 1.00mm |
| 1419 | Supply , installation, testing & balancing of 20 Gauge G I Damper with brass bushes and 6\\" pitch multiblade box type galvanised sheet steel construction volume control damper for Ducting and air washers to be provided with suitable links and quadrants for control of volume of air as per specifications complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1420 | Supplying, installing, testing and balancing of double louvered of extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed aerofoil shaped horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1421 | Supply air grill with key operated volume control damper |
| 1422 | Return air grill without volume control damper |
| 1423 | Supplying, installing, testing and balancing of extruded Aluminium powder coated Air Diffuser and complete with Flush, 20mm flanges with PVC/neoprene gasket, anti – smudge frame and removable inner core to facilitate the adjustable of air control damper, square/round/ rectangular as required.including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1424 | Supply Air Diffuser with Volume Control damper |
| 1425 | Return Air Diffuser without Volume Control damper |
| 1426 | Supply and fixing of acoustic lining of ducts with chemically cross link Oxide accetate foam open cell structure Acoustic Insulation with density 30 Kg / Sqm, UV protected and Class O Fire propperty Water Vapour absorption 0.002 gm / Sqcm, including cost of adhesive etc. complete in all respect. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 1427 | 25 mm thick |
| 1428 | Supply and fixing aluminium foil faced 50 mm thick Rock wool insulation of density 36 kg/cu.m after applying two coats of cold setting adhesive (CPRX Compound) sealing all joints with self adhesive tape & finished with 26 G Aluminium cladding. complete in all respect. (For Outdoor applications-air conditioning ducts) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 days