Tender For Petty Repairs Of E/M Nature Of Work Switch Socket Submain & Distribution Boxes Including Attending Complaint Day By Day On Emergency Basis At Mil Stn Pithoragarh And Other Connected Area Under Ge Pithoragarh
Tender Overview
Project Description
Tender for Petty Repairs Of E/M Nature Of Work Switch Socket Submain & Distribution Boxes Including Attending Complaint Day By Day On Emergency Basis At Mil Stn Pithoragarh And Other Connected Area Under Ge Pithoragarh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-Jul-2026 | Amendment in Schedule of Credit | Terms and Conditions | 21-Jul-2026 |
| 2 | 07-Jul-2026 | Amendment in BOQ | BOQ | 21-Jul-2026 |
| 3 | 21-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Jul-2026 |
| 4 | 28-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Attending complaints of electrical nature rectification of the fault as per the complaint lodged by the user onward and including LT Distribution Panel, faults such as decarbonising connections in the DB;s checking for disconnections, loose connection any burning/heating due to overloading in Didtribution boards and restoring electric supply, checking and repair of switch sockets MCB's any type, checking and reconnecting/providing earth connection to distribution boards, checking and rectifying fault including repair/replacement of tubelight fitting any type by replacement of worn out ballast, bipin holder, starter, wom out wire, repair of faulty fan by disconnecting and replacement of unserviceable parts such as capacitor, fan regulator, connecting wires, repair/replacement of lamp holder and wornout holder wire, repair / replacement of electric bell/buzzer/bell push and other internal accessories i.e switch, sockets 5/15 Amps, repair/replacement of short circuited point wiring/sub main wiring, repairs/replacement of recessed light fittings, checking and rectifying earth fault/leakage current in water tap, other home appliances, checking and rectifying faults in building security lights/fittings complete repairs to the extent by removing connections from the system, removing faults in wires, battens, conduit, sunken boxes, juction boxes, main switches, MCBs/DBs utility light fitting, lamp holders ceiling/exhaust fans and other connected fixtures of the internal electrification rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled and nothing extra shall be paid to him, on this account complete all as directed at site to the entire satisfaction of Engr-in-charge/users |
| 3 | Note for srl Item No 01: |
| 4 | The Contractor shall provide necessary T&P such as ladder, earth tester, insulation tester, earth megger(500Volts), drill machine, wires of appropriate size and conductor matching to existing one upto the length of 1.5 mtr including insulation tape, screws, nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled and nothing extra shall be paid to him on this account. |
| 5 | Attending complaint including taking down/refixing of flouresent tube light fittings/fixture repair shall be mesured against srl item No 01. |
| 6 | Cost of material and labour for providing new items shall be mesured and paid separetly under relevent items of Sch A against supply only hereinafter. |
| 7 | Contractor representive/Engineer will report to JE E/M daily FN/AN to collect routine/urgernt work releated to internal electric supply till completion of contract. The Work shall be attended by the contractor immediately. The contractor will ensured availablity of manpower equiped with or sort of petty item such as insulation tape, GI Screws nut bolts washers etc reqd to accopmlish the job. The contractor will also ensure availablity of every type of requisite T & P items to his tradesman. all routine/urgent jobs recd on Slip or complaint register will be prepaired and get signature of users & Slip / Register will be produce to intemate JE E/M of completion of work within 24 hours . In Case of any delay attending the complaints more than 8 hrs after handing over the complaint and 2 hrs per urgent works, the contractor shall be able to pay the penalty as describe the penalty clause given here as under:- |
| 8 | the penalaty shall be applicable to the contractor if the delayed is noticed by Engineer in charge more than 12 Hrs after handing over the work of urgent nature to contractor shall attend the job immediately and shall report to JE E/M within executive it the nature of job is such that the work cannot be comletedd with in 12 hrs than the fact decided by the GE/Engineer in charge if delayed more than 12 hrs period and GE is not satisfied with the reason for the delay than penalty at rate of 50/job shall be deducted from dues of contractors. |
| 9 | Please note that this penalty is excusive other than condition 56 IAFW-2249 & Shall be treated as interim condition of the contractor & shall inforced as an delay in individual job is noticed and no claim whatever on his account shall be entertained by dept. the decision of accepting officer in this regard shall be final and binding. |
| 10 | Attending complaint by one visit to one qtr will be considered as one job. |
| 11 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and removing material for taking credit (credit for material should be made as per condition sepretly) and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified. |
| 12 | Taking Down Switches, Socket, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc any type. All as specified and direct. |
| 13 | Point wiring of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in PVC casing & caping of size width 25 mmX 16 mm hight or higher with all fittings (ISI Marked) controlled by one switch including PVC Box and fitting fixture for switch and socket,Complete all as specified by Engr in Charge. |
| 14 | Point wiring of one 3 pin socket outlet, 5 A Same Board with other switches, with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in PVC casing & caping of size width 25 mmX 16 mm hight or higher with all fittings (ISI Marked) controlled by one switch including PVC Box and fitting fixture for switch and socket.Complete all as specified by Engr in Charge. |
| 15 | Point wiring of one 3 pin socket outlet, 5 A/15A Independent, with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 2.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in PVC casing & caping of sizewidth 25 mmX 16 mm hight or higher with combination PVC box of 15 A switch socket and all fittings (ISI Marked) or controlled by one switch including PVC Box and fitting fixture for switch and socket.Complete all as specified by Engr in Charge. |
| 16 | Point wiring of one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in Existing Conduite controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases (if Requried) to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 17 | Point wiring of one 3 pin socket outlet, 5 A Same Board with other switches, with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in Existing Conduite controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases (if Requried) to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 18 | Point wiring of one 3 pin socket outlet, 5 A/15A Independent, with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 2.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in Existing Conduite controlled by one switch including CI/MS sunk box for Piano type wiring or metal flush box for modular wiring of required size & as directed & 3 mm thick plastic laminated sheet for piano type wiring or cover plate for with frame modular type, including cutting chases (if Requried) to wall making good the disturbed surfaces to match with the existing specification complete all as specified. |
| 19 | S&F in repairs for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 20mm dia or higher cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. |
| 20 | S&F in repairs for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead but in existing concealed conduit . |
| 21 | S&F in repairs for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 6 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. |
| 22 | S&F in repairs for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 6 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead but in existing concealed conduit . |
| 23 | S&F switch piano flush button single pole one way 5/6 amps 240 volts. |
| 24 | S&F switch piano type single pole two way 1 module 6 amps 240 volts. |
| 25 | S&F switch piano flush button single pole one way 15/16 amps 230 Volts. |
| 26 | S&F socket 5 amps 5 pin flush type, 230 volts. |
| 27 | S&F socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts. |
| 28 | S&F bell push AC SP 240 volts flush type 5/6 Amps, single pole one way complete as all specified and directed. |
| 29 | S&F ceiling rose surface bakelite 3 terminals. |
| 30 | S&F Lamp holder insulated body with back plate for dome batten fittings. |
| 31 | S&F Electronic fan regulator stepped type,two module with five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fan complete, all as directed by Engineer in charge. |
| 32 | S&F switch modular type single pole one way 1 module 6 amps 240 volts. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 33 | S&F of switch modular type single pole two way 1 module 6 amps 240 volts. |
| 34 | S&F switch modular type one way 1 module 16 amps 230 Volts. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 35 | S&F socket 6 amps modular type 2/3 pin combined 2 module , 230 volts.Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 36 | S&F socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 37 | S&F Modular type Electronic fan regulator stepped type,two module with five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fan complete, Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 38 | S&F in repairs of bell push AC SP 240 volts Modular type 5/6 Amps, single pole one way complete as all specified and directed. Sample approved by GE or as per exsisting at site, all as specified and directed by Engr-in- Charge. |
| 39 | S&F in repairs of bell electric multi music type / AC SP 240 Volts Complete all as specified and directed. |
| 40 | S&F in repairs of Tube light fitting integrated type suitable for LED 20 W(4 feet) efficacy min 100 lumens/watt, indoor decorative LED batten complete with Aluminium housing and all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 41 | S&F in repairs of Tube light fitting integrated type suitable for LED 10 W (2 feet) efficacy min 100 lumens/watt, indoor decorative LED batten complete with Aluminium housing with all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 42 | S&F in repairs of LED bulk head fitting with opal diffuser min 10/12 Watt, 6500 K, IP-65, with Aluminium housing of efficient heat dissipation and integrated electronic driver with all accessories pre wired and making connection with cord flexible copper cable of suitable size from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 43 | S&F in repairs of LED light fitting recess mounted min 32/36 Watt, 6500 K 2' x 2' with and all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly all as directed. |
| 44 | S&F in repairs of LED light fitting recess mounted min 5-10 Watt, COB Light / Focus Light of any colour R/G/B/Y/W or multi colour, Aluminum PDC Housing, IP-65 waterproof weather proof and with all accessories suitable for exsisting cut in amstrong/grid/POP ceiling/ Ground complete with integrated electronic driver and making electrical connection properly all as directed. |
| 45 | S&F in repairs of LED light fitting flexible Rope Light of any colour,R/G/B/Y/W or multi colour, IP-65, water proof and weather proof, Surge Protection and High voltage protection with all accessories & driver suitable for decoration of gate/ pilllers/pole complete with integrated electronic driver and making electrical connection properly all as directed. |
| 46 | S&F in repairs of LED light fitting recess mounted min 5-10 Watt, 6000 K Round/Square Panel with all accessories suitable for exsisting cut in amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly all as directed. |
| 47 | S&F in repairs of Decorative wall light fixture made of polycarbonate, with metallic fitting fixture, including 9 W LED Bulb (White/Warm) complete all as specified and directed and making electrical connection properly all as directed. |
| 48 | S&F in repairs of 5/15 A Switch Socket Combination of PVC Box with Plug top of 15 Amp as per directed by engineer in charge. |
| 49 | S&F in repairs of LED Bulb 9 W all as specified and directed. |
| 50 | S&F in repairs of LED Bulb 12 Inverter type W all as specified and directed. |
| 51 | S&F in repairs of Decorative Gate Light made up of high grade unbreakable ploycarbonate material Globe type of dia min 200 mm and including 9/10 w LED Lamp including fixing of GI pipe of suitable dia (if requried), any mm long light grade, partly embedded on column of gate or wall with fixing arrangement complete and making electrical connection complete all as spfd. |
| 52 | S&F in repairs of LED post top lantern 35 Watt warm white/white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection including fixing of GI pipe of suitable dia dia, 300 mm long light grade, partly embedded on column of gate with fixing arrangement complete and making electrical connection complete all as spfd. |
| 53 | S&F in repairs LED street light fitting 35/36 Watt 230 V AC, in multiple optics,Outdoor type with high pressure die cast aluminum housing, IP-65, with 4 KV inbuild surge protection driver and heat resistant complete with driver, fixing the same by GI pipe medium grade minimum 25 mm dia bore pipe with two nos FI clamps of 40X4 mm duly painted and suitable size of nut and bolts etc and making poper electric connection with three core flexible copper wire complete all as specified and directed. |
| 54 | S&F in repairs LED street light fitting 60 Watt 230 V AC, in multiple optics,Outdoor type with high pressure die cast aluminum housing, IP-65, with 4 KV inbuild surge protection driver and heat resistant complete with driver, fixing the same by GI pipe medium grade minimum 25 mm dia bore pipe with two nos FI clamps of 40X4 mm duly painted and suitable size of nut and bolts etc and making poper electric connection with three core flexible copper wire complete all as specified and directed. |
| 55 | S&F in repairs of modular type 3/4 module power unit with 16 Amp plugtop Box with sheet steel enclosure MCB Combo plug and socket complete with one SP MCB 20 Amps, 240 Volts. Protection to human shock due to direct or indirect contact as well as provides protection from overload and short circuit faults, all as specifed and direced. |
| 56 | S&F in repairs of TPN DB, 4 Way, as per IS-8523, IP-42 protection, universal mounting with 200A copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCB TPN as incomer and MCB TPN/MCB as outgoing, with and including provision for MCCB/MCBs & making necessary electrical connection for Incoming & outgoing cables, with copper lugs, crimped with crimping tool |
| 57 | S&F in repairs of voltage rating 415 V,10 KA C- curve MCB FP TPN of 63-100 Amp with connection testing and commisioning. |
| 58 | S&F in repairs of sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification . |
| 59 | All as per item No 49 above but for 8 way. |
| 60 | All as per item No 49 above but for 12 way. |
| 61 | S&F in repairs of Amp rating 240,10 KA C- curve MCB SP of 6 to 32 Amp with connection testing and commisioning. |
| 62 | S&F in repairs of Amp rating 240,10 KA C- curve MCB DP SPN of 32 Amp with connection testing and commisioning. |
| 63 | S&F in repairs of Amp rating 240,10 KA C- curve MCB DP SPN of 40-63 Amp with connection testing and commisioning. |
| 64 | Supply and fix in repairs Single core unsheathed 1100 volts PVC-FRLS insulated wire with copper conductor(multistrand) ISI marked of size 1.5 Sqmm, complete all as specified and directed. |
| 65 | Supply and fix in repairs of Single core unsheathed 1100 volts PVC-FRLS insulated wire with copper conductor(multistrand) ISI marked of size 2.5 Sqmm, complete all as specified and directed. |
| 66 | Supply and fix in repairs Single core unsheathed 1100 volts PVC-FRLS insulated wire with copper conductor(multistrand) ISI marked of size 4.00 Sqmm, complete all as specified and directed. |
| 67 | Supply and fix in repairs of Single core unsheathed 1100 volts PVC-FRLS insulated wire with copper conductor(multistrand) ISI marked of size 6.00 Sqmm, complete all as specified and directed. |
| 68 | Supply & fixing in repairs of 1100 volts grade heavy duty cable with PVC insulated aluminiuum conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one twin core flat/circular 10sq mm solid conductor. |
| 69 | S&F in repairs Exhaust fan made of sturdy Engineering Plastic , PVC Body of size 250mm sweep single phase 230 V 50 Hz AC 1400 RPM energy saving, heavy duty motor copper wounded with die cast aluminium rotor mounted on two ball bearing complete with louvrs shutter including making hole of suitable size and making good disturbed surface (including making hole and plasterng, nacessary brickwork and distemparing to match with existing) connecting with 3 core copper cable to ceiling rose. All as specified and directed . Note; Old Unsv Fan shall be deposited to MES store by the contractor. |
| 70 | S& F in repairs water heater storage type (Geyser) single phase 230 V, 50 Hz, 5 star energy saving high density PUF insulation tank made of heavy duty mangesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type 25 Ltr Cap 2000 Watt rated power, incoloy 800 glass coated heating element, inner tank coating of feroglas powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8 MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners-04 Nos hot and cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 02 Nos non return valve 01 No and including necessary plumbing work, complete with intergated shock safe plug PRCD Plug with all protection features as per OEM design and standard all as specified and directed. Note; Old Unsv Fan shall be deposited to MES store by the contractor. |
| 71 | M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents