Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #56214528

Tender For Special Repairs To Magazine ( Build No P-21 To -28) At Nad Sunabeda Under Ge (P) (N) Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
1.43 Crore
Estimated cost
Bid Submission
13 Jul 2026
7 days left
EMD
2.19 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Magazine ( Build No P-21 To -28) At Nad Sunabeda Under Ge (P) (N) Visakhapatnam

BOQ

Name of Work:- SPECIAL REPAIRS TO MAGAZINE ( BUILD NO P-21 TO -28) AT NAD SUNABEDA UNDER GE (P) (N) VISAKHAPATNAM
Sl. No. Item Description
1Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
2M&L for Walling of random rubble uncoursed, brought upto courses well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and directed.
3M&L for Walling of random rubble uncoursed (but except stone) brought upto courses well bonded, bedded and solidly hearted built in CM 1:6 including Removing mortar from and cleaning stones, obtained from masonry of any description (except ashlar facings and dressed stone work) and stone setts from pavings; stacking for measurement including all extra handling and removal and disposing off rubbishcomplete all as specified and directed.
4M&L for Hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 40 mm for granite or trap stone face stones and dressing of face beds and joints, all as specified and as directed.
5M&L for PCC 1:2:4 Type B-1 using 20mm graded aggregate as in copings etc including necessary formwork etc complete all as specified.
6Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete as all specified and directed
7M & L Cement concrete type B0 1:2:4 (12.50 mm graded aggregate) as in roof padding, roof kerbs or mud stops including demolition of existing roof padding and removal of debris to outside MD land all complete all as specified and directed.
8M&L for Roof Treatment including the following complete all as specified and as directed:-(i) Taking out of existing water proofing treatment roughening surfaces of concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing with neat cement slurry @ 3.00 kg of cement per Sqm and PCC padding (30 mm theack). (ii) 10 mm thick rendering in CM 1:4 on surface mixed with WPC @ 2% by weight of cement as per manufacturers instructions. (iii) Cleaning of plastered surface and applying one coat of hot blown bituminous primer conforming to IS -3384 (latest) @ 0.5 Ltr / Sqm.
9(iv) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by torch application complete all as specified. Polymeric membrane shall be taken to a height of 30 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (v) Applying one coat of bituminous aluminium primer over APP membrane @ 0.11 Lit / Sqm. Note:- (a) Primer, APP membrane & bituminous aluminium paint shall be of same manufacturer and executed through applicator authorised by the approved manufacturer only. (b) Membrane shall be laid with side overlap of 100 mm and end overlap of 150 mm as per manufacturers instruction. (c) PCC Padding & WPC will be measured and paid separately.
10S&F for Wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples, size of mess 12mm complete all as specified and directed.
11S & F 5.5 mm thick sheet Glass ordinary quality,in any size fixed with glass putty or fitted with beads in squares exc 0.50 sqm in each pane in window and frames complete all as specified and as directed.
12M&L Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of AC sheeting of any type in roof coverings complete all as specified and directed.
13S&F rolled mild steel Framed work of grade Fe-410, (Gde E- 250), as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering to Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging, also fastening and fixing including dismantling structural steel work of any description not otherwise provided for complete all as specified and directed.
14M&L for rubber door seal gasket n.exc 10 cm wide all round the shutter of steel door to seal airtight inside the room omplete all as specified and as directed.
15S&F Rolled Mild steel for roof trusses (framed), Fe-410, (Gde E- 250), framed trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) with distance pieces, cleats etc. including dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
16M & L Cement concrete type B-1 1:2:4 (20 mm graded stone aggregate) as in surface channels an drains complete all as specified and directed.
17Demolition of cement concrete of any description from any position including removing the demolition material complete all as specified and as directed.
18M&L for 75 mm thick, PCC 1:3:6 Type C-2 using 40mm graded stone aggregate as in Plinth protection etc surface finished even and smooth with using extra cement complete all as specified.
19M&L for 75 mm thick, PCC 1:2:4 Type B-1 using 20mm graded aggregate with spike rolling to surfaces or making impressions of expanded metal while the concrete is green, over and including 100 mm thick, PCC 1:3:6 Type C-2 using 40mm graded aggregate as in footpath, hard standings etc surface finished even and smooth with using extra cement complete all as specified.
20S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
21Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
22M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in two layers of 10 mm and 5 mm thickness in cement mortar (1:4) and finished even and fair without using extra cement including mixing of water proofing compound in 5 mm thick layer as required as per manufacturers instructions complete all as specified and directed. (Note: WPC will be measured & paid separately)
23M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cemment all as specified and directed.
24M&L for rendering 5mm thick in cement mortar (1:3) on Ceiling brick / concrete surfaces, finished even and smooth without using extra cement all as specified and directed.
25Supply only Integral waterproofing compound complete all as specified and as directed.
26M&L for preparation of old concrete / masonry surfaces by brooming down or steel wire brushes scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying a coat of cement wash complete all as specified and directed.
27M&L for preparation of new wall surfaces plastered or unplastered and providing and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and as directed.
28M&L for preparation of new plastered surfaces of walls and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over & including a coat of primer complete all as specified and directed.
29M&L for preparation of new plastered surfaces of ceillings and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over & including a coat of primer complete all as specified and directed.
30M&L for preparation of new plastered surfaces and applying Three coats of white wash on Ceiling complete all as specified and directed.
31M&L for preparation of old surfaces plastered or unplastered of walls and including complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over surfaces complete all as specified and as directed.
32M&L for preparation of old surfaces plastered or unplastered of walls and including complete removal of existing treatment and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over & including a coat of primer complete all as specified and directed.
33M&L for preparation of old surfaces plastered or unplastered of ceilings and including complete removal of existing treatment and applying Two or more coats of Premium acrylic distemper having VOC less than 50 gm/litre of required shade (Company Depot Tinted) over & including a coat of primer complete all as specified and directed.
34M&L for preparation of old surfaces plastered or unplastered and including complete removal of existing treatment and applying Two coats of white wash on ceilings complete all as specified and directed
35M&L for applying two coat of fire resistant / intumescent paint on new steel surface over & including a coat of primer including preparation of surface of any description over 10 cm width or girth complete all as specified and directed.
36M&L for applying two coat of fire resistant / intumescent paint on old steel surface over & including a coat of primer including preparation of surface of any description over 10 cm width or girth complete all as specified and directed.
37S&F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
38S&F in repairs Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground on porcelain insulators suitable for running strip all as specified and dircted.
39S&F in repairs galvanized iron strip 32x6 mm size with saddles and fixing screws etc. for roof conductors and down conductors above ground on porcelain insulators suitable for running strip all as specified and dircted.
40S&F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and connecting to earth strip complete all as specified and directed.
41M&L for Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 x 6 mm size GI strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 5 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. including dismantling and taking down old earthing. complete all as specified.
42M&L for Pre-cast cement concrete block masonry Type B1, 1:2:4 mix (using 20mm size graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar CM 1:6 complete all as specified. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56214528
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.43 Crore
LAST DATE 13-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Magazine ( Build No P-21 To -28) At Nad Sunabeda Under Ge (P) (N) Visakhapatnam
Basic Detail
Tender No 82770
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 29 Jun 2026
Submission Date 13 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 1.43 Crore
Tender Fee 1000
EMD 2.19 Lakhs
Exemption Available
Document List
4501ba53-cf0e-4121-b0e1-823d43a0ec99.html
BOQ_868129.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

4501ba53-cf0e-4121-b0e1-823d43a0ec99.html

xls

BOQ_868129.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders