Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56214522

Tender For Repairs/Maintenance Of Water Supply Distribution Lines, Water Supply Assets Fire Hydrant System, Fire Pumps, Ms Pipes And Connected Items Of Newly Taken Over Buildings From Cce R&D At Drdl/Asl Under Ge(I) R&D Kanchanbagh, Hyderabad.

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
48.80 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
15 days left
EMD
97600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs/Maintenance Of Water Supply Distribution Lines, Water Supply Assets Fire Hydrant System, Fire Pumps, Ms Pipes And Connected Items Of Newly Taken Over Buildings From Cce R&D At Drdl/Asl Under Ge(I) R&D Kanchanbagh, Hyderabad.

BOQ

Name of Work:- REPAIRS/MAINTENANCE OF WATER SUPPLY DISTRIBUTION LINES, WATER SUPPLY ASSETS FIRE HYDRANT SYSTEM, FIRE PUMPS, MS PIPES AND CONNECTED ITEMS OF NEWLY TAKEN OVER BUILDINGS FROM CCE R&D AT DRDL/ASL UNDER GE(I) R&D KANCHANBAGH, HYDERABAD.
Sl. No. Item Description
1Dismantling the Monoblock/centrifugal pump set of 3 to 5 HP capacity 3 ph, 415V, AC, 50Hz after disconnection of electric/ pipe connections and providing dummy plates to suction and delivery lines, Shifting to the reputed workshop for repairs and replacing of minor spare parts like gaskets, packings, nuts, bolts and washers etc, and greasing, reassembling and replacement of other major parts as required and factory testing the rated flow discharge of the pump shifting to the original location and reconnecting of pipes/ electric connections at site and testing to the entire satisfaction of the Engr-in-charge. Note : Parts like impellars, shafts, bearings, seal and lantern rings will measured and paid seperately under relevant items of Sch A.
2All as per item No. 1 but of capacity 7.5 -10 HP
3All as per item No. 1 but of capacity 12.5 HP
4All as per item No. 1 but of capacity 15 HP
5All as per item No. 1 but of capacity 50 HP
6Supply only following spare parts suitable for Monoblock pumpset of capacity 3 to 5 HP
7Cast Iron / Mild steel/ Carbon steel Impellar suitable for the rated discharge and capacity
8Heavy thrust Ball BearingsMake : NBC/SKF or its equivalent.
9Gland Pack
10Shaft sleeve
11External fan
12Lantern ring and assembly packing as per the existing model.
13Supply only following spare parts suitable for Monoblock pumpset of capacity 7.5-10HP
14Cast Iron / Mild steel/ Carbon steel Impellar suitable for the rated discharge and capacity
15Heavy thrust Ball Bearings Make : NBC/SKF or its equivalent.
16Gland Pack
17Mild steel/Carbon steel shaft as per the existing model and specificati
18Shaft sleeve
19External fan
20Delivery flange assembly
21Lantern ring and assembly packing as per the existing model.
22Supply only following spare parts suitable for Monoblock pumpset of cap.12.5HP
23Heavy thrust Ball BearingsMake : NBC/SKF or its equivalent.
24Mechanical seal
25Mild steel/Carbon steel shaft as per the existing model and specifications
26Shaft sleeve
27Lantern ring and assembly packing as per the existing model.
28External fan
29Supply only following spare parts suitable for Monoblock pumpset of capacity 15HP
30Ball BearingsMake : NBC/SKF or its equivalent.
31Mechanical seal
32Mild steel/Carbon steel shaft as per the existing model and specifications
33Shaft sleeve
34Lantern ring and assembly packing as per the existing model.
35External fan
36Mild steel/ Carbon steel Impellar suitable for the rated discharge and capacity
37Suction flange assembly
38Gland plate
39Supply only following spare parts suitable for Monoblock/Centrifugal pumpset of capacity 50 HP
40Ball BearingsMake : NBC/SKF or its equivalent.
41Mechanical seal
42Mild steel/Carbon steel shaft as per the existing model and specifications
43Shaft sleeve
44Lantern ring and assembly packing as per the existing model.
45External fan
46Mild steel/ Carbon steel Impellar suitable for the rated discharge and capacity
47Suction flange assembly
48Gland plate
49M&L for Rewinding of Centrifugal/ MonoBlock Pump Motor of 3Ph, 415V, AC, 50Hz with super enamelled 99% copper winding wire (ISI marked brand) of gauge and turns per coil suitable for attaining the specified winding resistance as per the OEM details, Class H insulation paper for slots insulating, applying insulating varnish on the new coils and drying in the heating chamber, Testing the coils complete and connecting the terminals to the cable connector box, replacing the bearings , bushes bearing holders and other connected spares which are inescapable to complete the job all as directed for the following capacities. Note:- The winding resistance and insulation resistance after rewidning should be as per the OEM specifications and the test reports should be submitted before assembling the pump and motor.
50Monoblock pump Motor of capacity 3HP
51Monoblock pump Motor of capacity 5HP
52Monoblock pump Motor of capacity 7.5HP
53Monoblock pump Motor of capacity 10HP
54Monoblock pump Motor of capacity 12.5HP
55Monoblock pump Motor of capacity 15HP
56Monoblock pump Motor of capacity 50 HP
57Repair & servicing of existing pump starters in the LT control panels of any rating/ type and any capacity, Replacing unserviceable components such as contactors, Relays, Single phase preventers, meters, cable lugs, MCBs, Push buttons and CT coils etc including necessary wiring for DOL and Star- Delta starters using FRLS copper conductor of size not less than 1.5 Sqmm and necessary feruls and casing capping required to secure the wiring complete all as directed testing and commisioning to the entire satisfaction of the Engr-in-charge ( Note:- (i) Components required for replacement shall be measured and paid seperately under relevant Sch A items below.
58Supply only following parts of pump panels and fixing in existing panels (to incorporate under item No 19 above)
593 pole power contactor AC-3 type, 415 Volt Conforms to IS / IEC 60947-4-1 with required NO + NC add on blocks & operation voltage 380 to 400, suitable for 3 to 5 HP pump motor as per the current rating of the OEM name plate. Make:- Schneider /Legrand/L&T or its equivalent
60All as per item No 20.01 but for 7.5HP motor.
61All as per item No 20.01 but for 10HP motor.
62All as per item No 20.01 but for 12.5HP motor.
63All as per item No 20.01 but for 15HP motor.
64All as per item No 20.01 but for 50 HP motor.
65Electronic motor protection relay confirming IEC 947-4-1 with Selectable trip class - 10A, 10, 20 and 30 with inbuilt over load, earth fault, phase sequnce , Reversal, Locked rotor, trip indication, current coil and test features of current rating 5-28 Amps
66Star- Delta Timer
67AC Volt meter/Ammeter digital display, flush mounted, 96mmx96mm size. 0 to 600 Volt / 0-50 Amp.Make : AE /L&T /HPL or its equivalent.
68VAF+PF digital type class 1.0 accuracy meters with input voltage range 50-520V of size 96x96mm flush mounting type
69Epoxy ring type Current transfromer confirming IS 2705/1992, operating voltage 250V, 50/60Hz, of ratio 100/5Amps
70MCB TPN 63 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve . Make: Legrand/Havells/L&T or its equivalent.
71Supply only high strength Calcium hypo cloride granular disinfection chemical with Heavy metal(Mercury and Lead) containments below the detectable limit(BDL) as per the AAS test data all as specified. Make: ALTOCH-GP/ or any approved make of state board.
72Supply only bleaching powder for all purpose of water treatment
73Supply and fix CI sluice valve 80 mm dia class PN 1.6 flanged type with grey cast iron body, bonnet dome, wedge, stuffing box, gland thrust plate cap, SS spindle stem, carbon steel bolts, nuts etc complete complying to IS 14846 with necessary fixing arrangement as required at site by providing rubber/ fibre gaskets inclduing taking out old unserviceable valve of any type complete all as directed. Make :- KIRLOSKAR//KARTAR/ Zoloto/Audco
74All as per item No.23 above but of size 100 mm dia complete all as directed
75All as per item No.23 above but of size 150 mm dia complete all as directed
76All as per item No.23 above but of size 200 mm dia complete all as directed
77Removing the existing un serviceable gate valve and supply and fix new gun metal gate valves with iron wheel head screwed on both ends for iron pipe with necessary GI fittings of the following sizes :-MAKE : Leader/Zoloto/Neta/Mittal or its equivalent.
7820 mm dia
7925 mm dia
8040 mm dia
8150 mm dia
82Taking out existing unserviceable non return valve of any type/size and supply and fix CI non return valve of 50 mm bore dia conforming to IS 5312 both end flanged and including necessary fixing arrangement as required at site by providing rubber/fibre gasket ,nuts, bolts & washers etc complete all as specified as and directed.
83All as per item No. 25 above, but of size 80 mm bore dia
84All as per item No.25 above, but of size 100 mm bore dia.Make:- KIRLOSKAR /AUDCO/ Kartar or its equivalent
85Taking out existing unserviceable Foot valve suitable for 80mm dia pipe complete with flanges, packing, nuts and washers as required at site and testing as specified and directed
86All as per item No. 26 above, but of size 100 mm bore dia
87All as per item No. 26 above, but of size 200 mm bore diaMake:- KIRLOSKAR /AUDCO/ Kartar or its equivalent
88Supply and laying in trenches/on ground GI tubing 'Medium grade' 15 mm bore, with all fittings complete all as specified and as directed.
89All as per item No 27 above but of size 20 mm
90All as per item No 27 above but of size 25 mm
91All as per item No 27 above but of size 40 mm
92All as per item No 27 above but of size 50 mm
93All as per item No 27 above but of size 80 mm
94All as per item No 27 above but of size 100 mm
95Supply and laying in trenches/on ground CI tubing confirming IS 1537-1976 100 mm bore with flanged ends, centrifu-gally cast, class B, in any length laid in tre-nches, with all fittings complete all as specified and as directed.
96Supply and laying in trenches/on ground CI tubing confirming IS 1537-1976 200 mm bore with flanged ends, centrifu-gally cast, class B, in any length laid in tre-nches, with all fittings complete all as specified and as directed.Make for item 28 & 29:- Zindal/Tata or its equivalent
97Repairs to leakage run lead joint in position of any 100 mm CI pipes by burning out existing joints,recovering lead, cleaning internal surfaces of socket and providing new joints with using recovered lead and additional new lead, making joint leak proof.(Excavation of Earth work and the weight of lead wool required shall be measured and paid seperately)
98Repairs to leakage run lead joint in position of any 200 mm CI pipes by burning out existing joints,recovering lead, cleaning internal surfaces of socket and providing new joints with using recovered lead and additional new lead, making joint leak proof.(Excavation of Earth work and the weight of lead wool required shall be measured and paid seperately)
99Supply only lead wool for caulking the joints of CI pipes.
100M & L for CI fittings of any dia as required at site in repairs such as bends (any type, radius and angle) tapers any type ( straight, bend, incresing, decreasing or double socket etc) tee pieces single branch 'Y\\" junction, double branch, cross, collars, caps and plugs etc and all as specified and directed
101Excavation in trenches in Hard/dense soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of pipes and making bottom surfaces of excavation leveled.
102Returning, filling in trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as directed by the Engineer-in-Charge.
103Removing surplus soil / spoil to a distance not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed by the Engineer-in-Charge.
104Taking out the water samples in containers at different locations as directed by the Engineer-in-charge and getting the water tested from Director of Preventive Medicines, Narayanaguda, Hyderabad for the chemical and Bactoriological test and submission of the test results complete all as directed
105Material and labour for earthing complete with galvanised iron strip electrode 60x60cmx6mm thick, burried directly in ground(earth pit not less than 2.25metres deep below ground level) with top edge of the plate not less than 1.5metres below normal ground level, connected to galvanised earth lead strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to switchgear equipments/motors protected by 40mm dia light grade GI pipe upto a length of 7.5mtr including necessary excavation earth work, charcoal and salt PCC 1:3:6 type C1 for chamber 40mm thick RCC cover slab 1:2:4 type B1 with 8 mm dia TMT bars @ 100mm c/c both ways, 20mm dia GI watering pipe medium grade with funnel complete and testing complete all as directed.
106Supplying, laying heavy duty class 'C' MS pipe of 100 mm bore confirming to IS 1239 incl fittings ie Tees, bends,elbow , unions, reducers, flanges etc as required paint with two coat of fire red enamel paint over a coat of anti corrosive paint incluidng welding complete all as directed.
107Supplying, laying heavy duty class 'C' MS pipe of 150 mm bore confirming to IS 1239 incl fittings ie Tees, bends,elbow , unions, reducers, flanges etc as required paint with two coat of fire red enamel paint over a coat of anti corrosive paint incluidng welding complete all as directed.
108Supplying, laying heavy duty class 'C' MS pipe of 200 mm bore confirming to IS 1239 incl fittings ie Tees, bends,elbow , unions, reducers, flanges etc as required paint with two coat of fire red enamel paint over a coat of anti corrosive paint incluidng welding complete all as directed.Make for item no 36-39:- Tata/Zindal or its equivalent.
109Supply and laying of DI pipes heavy grade of size 150 mm dia with all fittings complete all as specified and directed.
110Disconnecting the pipe lines and removing unserviceable / leakage storage tanks of any type from the buildings/plat form and supply and fix hoist and install of Rotational moulded water storage tanks (cylindrical vertical with closed lid) 6 layered anti bacterial made with 100% food grade plastic and UV stabilised white layer inside the tank and of any color outside other than the black and connecting all pipe lines of following capacities complete all as directed.
111500 litre capacity
1121000 litre capacity
1132000 litre capacity
1143000 Litre Capacity
1155000 Litre capacityMake for item no 43.01 to 43.05 :- SINTEX/ PLASTO/ CERA/ Polycon or its equivalent
116S & F in repair float valves ISI marked high pressure of PTMT with epoxy coated sluminium rod and high density plastic ball, screwed for 20mm bore iron pipe, including replacement of aduscent GI fittings complete, weight not less than 210 grm. Make : Prayag / Polytuff or its equivalent
117S & F in repair float valves ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 25mm bore iron pipe, including replacement of adjucent GI fittings complete, weight not less than 142 grm. Make : Prayag / Polytuff or its equivalent
118Material and labour for construction of valve chamber of size 900x900x600mm internal size including necessary earth work and excavation, PCC 1:4:8 type D2 for foundation, brick work in cement mortar 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40x40x6 mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chorme primer and locking arrangements complete all as directed.
119All as per item No.46 above but of size 600mm x 600mm x 600mm complete all as directed
120Supply only and testing Submersible cable 3Core, 4 Sqmm copper conductor multistranded, 1100 Volts grade, Flat type PVC insulated, PVC sheathed confirming IS-694 all as specified.Make:-Havells/Gloster/KEI or its equivalent.
121M&L for cutting existing road incl black top surfaces of required width and depth for laying of pipe line, refilling and making good after laying of pipe with removed soii and finally sealed with cement concrete of thickness not less than 100mm to match with the top surface of Road.(Cement concrete shall be measured and paid seperately under appropriate item)
122M & L for cement concrete 1 : 2 :4 type C2 using 40mm stone aggregate, as in repairs to RCC pipe line/ Valve pits / disturbed hard standing or any other repair as required at site at any situation all as specified as directed.
123Supply and laying of UPVC pipes of size 25 mm dia with all fittings complete and fixed on wall/floor/ceiling complete al as specified and directed.
124Supply and laying of UPVC pipes of size 20 mm dia with all fittings complete and fixed on wall/floor/ceiling complete al as specified and directed.
125Taking out unserviceable DOL Starter from panel board after disconnecting electric connection and Supply and Fix DOL Starter suitable for 3 to 7.5 HP, 3Phase, 415Volts, AC, 50Hz and reconnection to existing system and testing complete all as as directed
126Taking out unserviceable Star Delta Starter from panel board after disconnecting electric connection and Supply and Fix DOL Starter suitable for 10 to 15 HP, 3Phase, 415Volts, AC, 50Hz and reconnection to existing system and testing complete all as as directed
127Taking out unserviceable single phase preventor after disconnecting of electric supply and Supply and Fix Single phase preventor 415Volts, AC, 50Hz suitable for pumpset 3 HP to 10 HP and reconnecting of electric supply and testing complete all as directed Make:- MINILEC/L&T/SIEMENS or its equivalent.
128Supply and fixing HDPE pipe of 10 kg/sqmm grade, 65/63mm bore with all fittings complete and suitable for submersibble pump set.
129Lifting the falldown submersible pump set in side the bore along with the motor not exc to 12.5 HP capacity from any depth and column pipe of 50mm bore/100 mtr bore including lowering and re-fixing, testing & commissioning after carrying out minor repairs complete all as directed.
130Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 Core.
131Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 Core.
132Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4.0 Core.Make for item no 58 to 60: Havells/Polycab/Finolex/KEI/Gloster or its equivalent.Note: Excavation, refilling and removal shall be measured and paid separately.
133Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 450mm x180mmx40mm. Complete all as specified and directed.
134M & L Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed . NOTE:- Punned thickness shall only be measured and paid.
135Taking down old unserviceable hydrant valve and Supply, Installation, Testing and Commissioning of Single Headed Hydrant valve confirming to IS 5290 with ISI mark of size 63 mm dia oblique type with instantaneous hose coupling adaptor etc. with all neceesary fittng materials complete required.
136Taking down old unserviceable hydrant valve and Supply, Installation, Testing and Commissioning of Double Headed Hydrant valve confirming to IS 5290 with ISI mark of size 63 mm dia oblique type with instantaneous hose coupling adaptor etc. with all neceesary fittng materials complete required.
137Taking down old unserviceable hydrant hose pipe and Supply, Installation, Testing and Commissioning of Hydrant hose pipe, 63 mm dia and 1x15 mtrs long RRL type with Gunmetal 63 mm size male coupling at one end and female coupling at the other end. It should with stand a burtsting pressure of 450 psi, rot proofed, with ISI mark. Hose shall comply to IS 636
138Replacement of Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yardall as specfied and directed.
139Replacement of Fire hydrant stand post both ends flanged 1.5 Mtr long 80 mm dia with one end bent to 90 degrees suitable for long single fire hydrant valves including duck foot bend double end flanged and sluice valve all as specfied and directed.
140M&L for Scrapping of old existing paint of pipe lines any sizes and applying two coats of enemel paint to match with the existing shade complete all as directed.Note - Rate quoted shall be deemed to include cost of Paint & tools. Make - ASIAN/SHALIMAR/BERGER OR ITS EQUIVALENT
141Taking down old unserviceable stand post type water monitor hydrant valve and Supply, Installation, Testing and Commissioning of stand post type water monitor confirming to IS 5290 with ISI mark of size 63 mm dia oblique type with instantaneous hose coupling adaptor etc. with all neceesary fittng materials complete required.
142Bailing out water completely from the underground sumps of the following capacities and cleaning internal surface of RCC under ground sump by using pressure jet pumps,bleaching powder, scrapping, removing the scales, dirt and washing out with water completely and applying two coats of cement wash as directed and writing the relevant information like date of cleaning, capacity etc with the black paint on white back ground at visible place complete all as directed .
14350,000 ltrs capacity at NGARM pump house
14468,000 ltrs capacity at PJ-10 pump house
14590,000 Ltrs capacity at RTH pump house
1461,00,000 ltrs capacity at Sprite pump house
1471,50,000 ltrs capacity at DSC and New pump house
1481,80,000 ltrs capacity at Main pump house
1492,00,000 ltrs capacity at Filter pump house
1503,00,000 ltrs capacity at Gutta reservior
1514,00,000 ltrs capacity at Main pump house
152Bailing out water completely from the Over head tanks of 15 to 18 metre high staging of the following capacities and cleaning internal surface of RCC OH Tank by using pressure jet pump bleaching powder, scrapping, removing the scales, dirt and washing out with water completly and applying two coats of cement wash as directed and writing the relevant information like date of cleaning, capacity etc with the black paint on white back ground at visible place complete all as directed .
15320,000 ltrs capacity at Sprite and PJ-10 Pump house
1541,00,000 ltrs capacity at Wet canteen, LPD and ASTRA
15510,000 ltrs capacity at Baby Crech
156Disconnecting cable and pipe line of bore wells and lifting and taking out submersible pump set of any capacity along with submersible cable and galvanised steel tubings of any size from the bore well at any depth and lowering the same in to the bore well after repairs / replacement of spare parts under relevant items , and reconnect pipes and necessary electric connection complete all as directed.Note (i):- Equipments like tripod and chain pulley block etc., are required for this job and the same shall be arranged by the contractor and the rates quoted is deemed to included for the same. (ii). Spare parts will be measured and paid separately under relevent item of Schedule 'A\\" as supply only
157Flushing of bore well of any depth with the compressed air continuous to remove complete loose soil, silt/sludge till the clear water is obtained complete all as specified and directed.
158Dismantling the Submersible pump set of capacity 5 HP 3 ph, 415V, AC, 50Hz opening for assessing the repair and including replacing of minor spare parts like Shaft bushes, neckring, nuts bolts, washers etc, and greasing, reassembling and refixing of pump and Motor and replacement of other parts in place of worn out spare parts complete all as directed
159All as per Item No.74 above but of capacity 7.5 HP.
160All as per Item No.74 above but of capacity 10 HP. Note for item no's 74 to 76:-Spare parts will be measured and paid separately under relevent item of Schedule as supply only.
161Supply only following spare parts suitable for submersible pumpset of capacity 5 HP
162Stainless steel impellers as per the existing size and model auitable as per OEM
163Heavy walled class 30 cast iron Discharge Boul
164bush for suction
165High thrust 416 SS Pump shaft
166Bronze Discharge Bearing/Thrust bearing of make :NBC/SKF
167Thrust plate
168Strainer
169Supply only following spare parts suitable for submersible pumpset of capacity 7.5 HP
170Stainless steel impellers as per the existing size and model auitable as per OEM
171Heavy walled class 30 cast iron Discharge Boul
172bush for suction
173High thrust 416 SS Pump shaft
174Bronze Discharge Bearing/Thrust bearing of make :NBC/SKF
175Thrust plate
176Strainer
177Supply only following spare parts suitable for submersible pumpset of capacity 10 HP
178Stainless steel impellers as per the existing size and model auitable as per OEM
179Heavy walled class 30 cast iron Discharge Boul
180bush for suction
181High thrust 416 SS Pump shaft
182Bronze Discharge Bearing/Thrust bearing of make :NBC/SKF
183Thrust plate
184Strainer
185M&L for Rewinding of Submersible Pump Motor of 3Ph, 415V, AC, 50Hz with submersible PVC insulated 99% copper winding wire (ISI marked brand) of gauge and turns per coil suitable for attaining the specified winding resistance as per the OEM details, Class H insulation paper for slots insulating, applying insulating varnish on the new coils and drying in the heating chamber, Testing the coils complete and connecting the terminals to the cable connector box, replacing the bearings , bushes bearing holders and other connected spares which are inescapable to complete the job all as directed for the following capacities. Note:- The winding resistance and insulation resistance after rewidning should be as per the OEM specifications and the test reports should be submitted before assembling the pump and motor.
186Submersible pump Motor of capacity 5 HP
187Submersible pump Motor of capacity 7.5 HP
188Submersible pump Motor of capacity 10 HP
189Supply & fix 50mm GI pipe heavy duty with heavy sockets suitable for submersible pump set.Make : Jindal/Tata/Zenith or its equivalent Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56214522
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.80 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs/Maintenance Of Water Supply Distribution Lines, Water Supply Assets Fire Hydrant System, Fire Pumps, Ms Pipes And Connected Items Of Newly Taken Over Buildings From Cce R&D At Drdl/Asl Under Ge(I) R&D Kanchanbagh, Hyderabad.
Basic Detail
Tender No 8219
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 29 Jun 2026
Submission Date 21 Jul 2026
Open Date 23 Jul 2026
Finance
Tender Value 48.80 Lakhs
Tender Fee 500
EMD 97600
Exemption Available
Document List
Tendernotice_1.pdf
Tenderpages.pdf
4299588d-8d1d-4aa6-ad0f-94784f3f41d5.html
BOQ_868103.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

Tenderpages.pdf

html

4299588d-8d1d-4aa6-ad0f-94784f3f41d5.html

xls

BOQ_868103.xls

Disclaimer