Tender For Addition Alteration Of Warehouses At Cgasd Goa Under Ge (I) )Cg) Goa
Tender Value
19.90 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
19 days left
EMD
39800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition Alteration Of Warehouses At Cgasd Goa Under Ge (I) )Cg) Goa
BOQ
| Sl. No. | Item Description |
| 1 | B/R WorksDemolition of concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) in any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 2 | Material and labour for Portland cement concrete design mix with 12.5mm graded aggregate of grade M30 complete all as specified and as directed. |
| 3 | Material and Labour for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and including 20 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directedNote: Cement screed bed shall be measured and paid separately |
| 4 | Material and labour for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement rendering of 10mm in cement mortar (1:6) complete all as specified and as directed. |
| 5 | Material and labour for taking down cement plaster of any description on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster and dubbing out average 15mm thick in cement mortar 1:6 on irregular face of walls (when specifically ordered in writing) including removing debris/rubbish materials off the site all as specified and as directed. |
| 6 | Material and labour for rendering 15mm thick in cement mortar 1:6 on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and as directed |
| 7 | Material and labour for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the surfaces complete all as specified and as directed. |
| 8 | Supply and fix rolled mild steel Fe-410-w (grade E-250) quality A framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work complete all as specified and as directed. |
| 9 | Supply and fix in roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, etc. of FE-410W (Gde-E-250) quality B complete all as specified and as directed. |
| 10 | Supply and fix mild steel screw bolts diameter of neck 5 to 10 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long complete all as specified and as directed. |
| 11 | Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/ on Chajjas, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction complete all as specified and as directed. |
| 12 | Supply and fix Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/ on Chajjas, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction complete all as specified and as directed. |
| 13 | Material and labour for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 14 | Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed. |
| 15 | Taking down existing rolling shutter of any description exceeding 2 sqm each complete all as specified and as directed. |
| 16 | Supply and fix steel rolling shutters thickness of laths 1.00mm with ball bearing as specified including top cover, anchoring rod, hasp and staple and one coat of primer, erected in position as indicated, gear operated type with chain wheel and hand chain, Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed |
| 17 | Providing and fixing factory made UPVC white colour SKY LIGHT windows with glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2+-0.2mm thick galvanised steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, hardware (Touch Lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and as directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) Area exceeding 2.00 sqm each |
| 18 | Material and labour for precast cement concrete block masonry with solid blocks made out of PCC 1:3:6, type C-1 with using 20mm graded stone aggregate, exceeding 10cm in width and setting in cement mortar 1:6 etc. complete all as specified and as directed. |
| 19 | Material and labour for hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40mm x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and as directed. |
| 20 | Material and labour for aluminium anodised snap grid frame work for false ceiling all as specified size of grid 605mmx605mm complete all as specified and as directed |
| 21 | Supply and fix gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions in ceiling flat or sloping in joint less finish with jointing compound and jointing tape complete all as specified and as directed. |
| 22 | Material and labour for Vitrified dark shade Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm as in floors/vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match screed bed of 15 mm thick of cement mortar 1:6 complete all as specified and as directed. |
| 23 | Material and labour for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing and including 20mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed. |
| 24 | Material and labour for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete and including 10mm thick rendering in CM(1:4) complete all as specified and as directed |
| 25 | Supply and fix pillar cock of 15mm bore, cast copper alloy with capstan heads fancy type, chromium plated screwed down, high pressure, with long screwed shanks and flynuts, screwed for iron pipe and fixed complete all as specified and as directed |
| 26 | Supply and fix PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 27 | Supply and fix soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 28 | Supply and fix sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. |
| 29 | Supply and fix vitreous China wash basin white flat back, size 630mm x 450 mm excluding taps, waste, chain and plug and porcelain stopper including PTMT waste coupling 32mm dia (min weight 45 gm) 15mm bore PTMT pillar tap complete all as specified and as directed. |
| 30 | Supply and fix 15mm bore medium grade galvanized steel tubes with all fittings and fixed to wall or in floors etc. complete all as specified and as directed. |
| 31 | All as per item No 30 described here-in-before but 20 mm dia bore complete all as specified and as directed. |
| 32 | E/M WorksTaking down carefully old existing batten/PVC casing capping (or) conduit point aluminium/copper wiring i.e. light, fan, bell, socket including batten/ casing/ conduit, switch boards, laminated sheets, round blocks, MS Sunken boxes, light fittings/ holders of any type, other fittings & fixtures and making good the disturbed surfaces, walls, floors and stair cases complete all as specified and as directed. |
| 33 | Taking down old aluminium/ copper sub main wiring of any type and capacity including all accessories complete all as specified and as directed. Note : Old dismantled wiring and accessories will be contractors property and credit will be charged against schedule of credit. |
| 34 | Material and labour for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn through and including non metallic rigid PVC conduit (medium quality) not less than 25mm dia and conduit accessories concealed in wall/ floor/ ceiling, provision of factory made branded galvanised steel pressed terminal box (Modular metal flush box with cover plate) 3mm thick of suitable module with white cover plate of same module with frame for housing the modular switches, sockets, fan regulators etc. including 1.5 Sqmm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire connecting to common earth dolly etc. complete all as specified and directed. |
| 35 | One light /fan/exhaust point controlled by one way switch 5/6 Amp complete all as specified and as directed. |
| 36 | One socket point 6 Pin 5/6 Amp on same board complete all as specified and as directed. |
| 37 | One socket point 3 pin, 5/6 Amp on Independent board complete all as specified and as directed. |
| 38 | All as per item No 34 described here-in-before but with 2.5 Sqmm size cable multi stranded FRLS copper wire unsheathed for one 6 pin socket outlet 16 Amp on independent board including 2.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth dolly completed all as specified and directed. |
| 39 | Supply and fix modular switch 1 way 6A, 1 module complete all as specified and as directed. |
| 40 | Supply and fix modular socket 6A -2/3 pin combined 2 module complete all as specified and as directed. |
| 41 | Supply and fix modular switch 1 way 16A, 1 module complete all as specified and as directed. |
| 42 | Supply and fix modular socket 1 way 16A, 1 module complete all as specified and as directed. |
| 43 | Supply and fix modular electronic fan regulator 5 step, 100 W, 240V complete all as specified and as directed. |
| 44 | Supply and fix in repairs ceiling fans, 230V, 1200 mm sweep along with necessary accessories like down rod, blades, fixing rubber clamps, cups etc. with squirrel cage induction motor, marking of MES No and depositing old unserviceable ceiling fan in MES store yard complete all as specified and as directed. |
| 45 | Supply and fix Supreme Plus Air circulator wall Fan 450 mm sweep made out of MS metal Body of high Performance with smooth oscillation, 100% Copper Motor with speed control and 230 V single phase fixed with suitable size Gl bolts, nuts and washers duly grouted and connecting up with 0.75 Sq.mm size 3 core PVC insulated flexible cable with multistranded copper conductor from ceiling rose to connector of exhaust fan complete all as specified and as directed. |
| 46 | Supply and fix in repairs LED tube light fitting 1 x 20 W, 230V wall mounted integrated PVC batten, 4 feet LED module shall confirm to IS-16103 and shall bear BIS certification marking complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and as directed. |
| 47 | Supply and fix in repairs 1 x 35 watts LED building security light made up of pressure die cast housing with toughened glass and individual LEDs with secondary optics and IP66 protection for building security lights complete all as specified and as directed. |
| 48 | Supply and fix PVC FRP junction box with copper bus bar current carrying capacity 200 Amp along with 01 No MCB TPN of 32 Amp fixed on wall with clamp, nut & bolt connections complete all as specified and as directed. |
| 49 | Supply and fix Nature time switch using infrared sensor technology based automatic street light control panel enclosed in SMC boxes with one No MCB SP 10/16 Amps, connector 4 way 16 Amps including fixing clamps, nut bolts etc. complete all as specified and as directed. |
| 50 | Supply and fix in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, including 20 amp C series MCB protected complete all as specified and as directed. |
| 51 | Supply and fix in repairs TPN MCB distribution board, double door CRCA steel sheet enclosure powder coated, TPN 4 Way as in replacement with 200 Amp rated bus bar complete all as specified and as directed. |
| 52 | Supply and fix in repairs MCB distribution board, double door CRCA steel sheet enclosure powder coated, SPN 8 Way as in replacement with 200 Amp rated bus bar complete all as specified and as directed. |
| 53 | Supply and fix in repairs MCB TPN 63 A, 415 Volt as in replacement complete all as specified and as directed. |
| 54 | Supply and fix SPN 40 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity of in the MCB DB complete all as specified and as directed. |
| 55 | Supply and fix MCB SP 06 to 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity of in the MCB DB complete all as specified and as directed. |
| 56 | Material and labour for sub main wiring complete with and including two runs of 1.5 sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic PVC conduit of suitable size including accessories etc. as required and concealed in walls/ floors and 1.5 sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly etc. complete all as specified and as directed.Note :(i) Two runs of 1.5 sqmm PVC insulated cable and one run of 1.5 sqmm cable and one run of PVC conduit shall be measured as one unit length.(ii) The cost of cutting chases and the cost of making good the disturbed surfaces shall be measured and paid separately(iii) The wiring shall be done in proper colour coding using red for phase & black for neutral and green for earth leads. |
| 57 | Material and labour for sub main wiring complete with and including two runs of 4.0 sqmm, single core FRLS, PVC insulated and unsheathed, multistranded, copper conductor cable, single core, 1100 Volts grade drawn through and including non metallic PVC conduit of suitable size including accessories etc. as required and concealed in walls/ floors and 4.0 sqmm PVC multistranded copper conductor cable for earthing and connected to common earth dolly etc. complete all as specified and as directed.Note :(i) Two runs of 4 sqmm PVC insulated cable and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one unit length.(ii) The cost of cutting chases and the cost of making good the disturbed surfaces shall be measured and paid separately(iii) The wiring shall be done in proper colour coding using red for phase & black for neutral and green for earth leads. |
| 58 | Supply, lay, joint & testing XLPE Insulated, Screened, PVC bedded, Galvanized steel strip or wire, armoured, Electric Power Cables (heavy duty) with stranded aluminium conductor 1100 volt grade, of size 4 core x 16.0 sqmm core laid in trenches/ through GI Pipe/ fixed along with pole structure etc. complete all as specified and as directed.Note : Necessary earthwork, cable protection items shall be measured & paid separately. |
| 59 | Material and labour for Earthing complete with using GI earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using galvanised iron wire 4mm dia as earthing lead moulded and retrieved to earth plate at one end and connected to main switch / control board at another end with and including 40 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provision of PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate) duly reinforced with mild steel round bar 8 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessary excavation and earth work including laying the pipe concealed in floor / wall all as per plate No.3 of SSR Part-I complete all as specified and as directed including testing on completion Note: If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 days