Tender For Repair/Replacement, Maintenance And Improvement Of Street Light/Security Lights, Poles Painting And Another Misc Work At Unit Loc At Mil Stn Dhrangadhra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Jul 2026
18 days left
EMD
22000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Surendranagar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement, Maintenance And Improvement Of Street Light/Security Lights, Poles Painting And Another Misc Work At Unit Loc At Mil Stn Dhrangadhra
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard and dense soil and getting out complete all as specified and directed. |
| 2 | Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed. |
| 3 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. |
| 4 | M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid. |
| 5 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed. |
| 6 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed. |
| 7 | Taking out sub class burnt bricks from the trenches and stacking at site serviceable /unserviceable bricks for reuse complete all as specified and directed. |
| 8 | Laying only sub class brunt bricks as cable protection cover all as directed. |
| 9 | Supply and laying sub class old 'B' burnt bricks laid as cable protection cover complete all as specified and directed. |
| 10 | S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed. |
| 11 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 6 sqmm x 2 core with glands, cable protection pipes, cable route indicator etc., complete from the trenches/fixed on wall (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 12 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 10 sqmm x 2 core with glands, cable protection pipes, cable route indicator etc., complete from the trenches/fixed on wall (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 13 | Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 10 sqmm x 4 core with glands, cable protection pipes, cable route indicator etc., complete from the trenches/fixed on wall (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make |
| 14 | Supplying & laying, XLPE insulated PVC inner sheathed, 6 Sqmm, 2 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 15 | Supplying & laying, XLPE insulated PVC inner sheathed, 10 Sqmm, 2 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 16 | Supplying & laying, XLPE insulated PVC inner sheathed, 10 Sqmm, 4 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed. |
| 17 | M&L Painting to steel tubular poles LT of 8.5/9Mtr long incl fittings and fixtures complete, fixed with poles with one coat of alluminium paint incl scrapping of rusts and preparation of surfaces and writing Numberfrom white enamel paint of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel/RCC surfaces of electric poles.etc., complete all as specified and as directed by Engr-in-Charge. |
| 18 | Taking down existing LED light fitting 25/45/70/90 W from LT poles ,cleaning of prismatic polycarbonate cover, remove the corban and reconected to ACSR conductor by using new aluminium service wire 2.0 mm from conductor to LED street light all as specified and directed. |
| 19 | Taking down and refixing existing LED light fitting from LT poles, removed LED driver and ,Supply & fix new electronic driver assembly for LED street light fitting of 35 watt all as specified and directed |
| 20 | Taking down and refixing existing LED light fitting from LT poles, removed LED driver and ,Supply & fix new electronic driver assembly for LED street light fitting of 45 watt all as specified and directed |
| 21 | Taking down and refixing existing LED light fitting from LT poles, removed LED driver and ,Supply & fix new electronic driver assembly for LED street light fitting of 70 watt all as specified and directed |
| 22 | Taking down and refixing existing LED light fitting from LT poles, removed LED driver and ,Supply & fix new electronic driver assembly for LED street light fitting of 95 watt all as specified and directed |
| 23 | S&F, in repair, FRP insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth existing pipe, fixed on pole/wall from juntion box to street light fitting complete all as specified and directed. including taking down old |
| 24 | S&F, in repair, LED flood light luminaire of 210watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking down old Make - Bajaj or Chrompton/Havells/Philips all as specified and directed. |
| 25 | S&F, in repair, LED flood light luminaire of 170watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old Make - Bajaj or Chrompton/Havells/Philips all as specified and directed. |
| 26 | S&F, in repair, LED flood light luminaire of 120 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old per Make - Bajaj or Chrompton/Havells/Philips as all specified and directed |
| 27 | S&F, in repair, LED flood light luminaire of 100 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old per Make - Bajaj or Chrompton/Havells/Philips as all specified and directed |
| 28 | S&F, in repair, LED flood light luminaire of 50 watts with high pressure die cast housing with IP-66, power coated with gray colour finish, prismatic polycarbonae cover with LED lenses complete all as including taking dowo old per Make - Bajaj or Chrompton/Havells/Philips as all specified and directed |
| 29 | S&F, in repair, LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 66 protection |
| 30 | S&F, in repair LED street light fitting 45 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 66 protection |
| 31 | S&F, in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete |
| 32 | S&F, in repair LED street light fitting 90 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete |
| 33 | S&F, in repair, PVC junction box, factory made, size 180x290x110mm with one No SP MCB of 06 Amp rating, class-B and 3 Nos connector fixed on pole with necessary clamps and bolts etc and connecting with street light cable including taking dowo old complete all as specified and directed. |
| 34 | S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 35 mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo old complete all as specified and directed. |
| 35 | S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 40mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo old complete all as specified and directed. |
| 36 | S&F, in repair, Round circular of 40mm dia light grade GI pipe dia meter of circle not less then 1.5m suitable for fixing in top of 9 meter steel tubler pole with all nuts bolts , clamp,cross chanel and circular cap for fixing of pole suitable for fixing three nos flood light all as specified and directed |
| 37 | Supply, installation, commissoning and testing, in repair street light timer panel along with Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54 Extended wide band coil FRLS (Fire retardant low smoke) Internal wiring In-built Short-Circuit Protection with Digital 24 hour timer-01 no,Contactor Rating (A) 32 / TP40 / TPN-01no as per havells Cat part no IHXTS03060 or equivalent to L&T/ C&S/ ABB all as specified and directed |
| 38 | Supply, installation, commissoning and testing, in repair street light Time switch analog time switch,with Conforms to single phase, 230 volts with 24 hours time setting, current rating 16 Amps as per Havells, ABB/ Seimens/ C&S |
| 39 | Supply, installation, commissoning and testing, in repair street light AC relay type ML-3 and with MCB TPN, C curve 32 Amp, three phase,Make Havells/ L&T/ABB/ or equivalent to other make all as specified and directed |
| 40 | Supply and fixing post top lantern LED type 20watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp including taking down old one complete.make havells cat part CORALMINIPT25WLED 757PSYMTOPC or equvalent Bajaj/Chrompton /wipro / Philips |
| 41 | Taking down and refixing existing LED light fitting from bolard light , removed LED driver and ,Supply & fix new electronic driver assembly for LED bolard light fitting of 5 to 10 watt all as specified and directed |
| 42 | S& F 25 cm dia garden dome light with milky colour unbreakable PVC holder type B22 with out LED Bulb water proof fixed on existing GI pipe with same shape all as directed by Engr-in-Charge including taking down old |
| 43 | S&F LED Solar street light fitting battery suitable for 25 Watt with high efficiency ,lithium ferro phosphate battery with in built ,all as fixing as existing light complete all as specified and directed .make Havells/ bajaj/philips or equivalent |
| 44 | Supply and fixing path directional reflector with PC diffuser and aluminium power coated bollard provided uniform illumination for pathways LED type 9 watt 230 watt volts AC outdoor type with decorativepost for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lamp including taking down old one complete complete.make havells/ Bajaj/Chrompton /wipro / Philips Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 days