Tender For Repair, Replacement And Sewage Lines Septic Tank, Manholes And Soakwell Etc At Def Emp Coy, Hq 21 Corps And Officers Enclave Under Ge Dronachal
Tender Value
25 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
8 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair, Replacement And Sewage Lines Septic Tank, Manholes And Soakwell Etc At Def Emp Coy, Hq 21 Corps And Officers Enclave Under Ge Dronachal
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches n exc 1.5m wide and not exc 1.5m in depth and getting out in any type of soil by using of mechincal plant or chisel cutting for shafts, wells, man holes and for sewage lines and foundation etc n exc 10 SQM on plan including cleaning the Sludge Etc and Excavation in Areas where sludge is accumulated by making proper arrangements etc complete all as specified and directed. |
| 2 | Excavating in trenches n exc 1.5 Mtr wide and n exc 1.5 M deep and getting out in hard rock by using of mechincal plant or chisel cutting for shafts, wells, man holes and for sewage lines and foundation etc n exc 10 SQM on plan including cleaning the Sludge Etc and Excavation in Areas where sludge is accumulated by making proper arrangements complete all as specified and directed. |
| 3 | Demolition of brick and stone masnary work built in cement mortar incl all quions, arches, pillars etc. but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed. |
| 4 | Demolition and breaking up drain pipes, soil , waste and pipes etc (RCC/ SWG/CI etc) PCC bed concrete of any description in trenches or floors, including connections and fittings all as specified and as directed of following bore size . |
| 5 | (a) 150mm |
| 6 | (b ) 200mm |
| 7 | Demolition of cement concrete in any floors and pavings not exc. 15 Cm thickness (below/above ground level) including floor finishes complete all as specified and directed. |
| 8 | Material & labour for concrete bed of PCC 1:4:8 type C2 using 40 mm graded stone aggregate for including packing under and completely surrounding pipes with concrete after they are laid and tested; in complete all as specified and directed. Note:-Thickness of bed below the barrel of pipes: 10cm for pipes 100 mm and 150mm dia &15cm for pipes 200mm dia and over. |
| 9 | (a) 150mm |
| 10 | (b) 200mm |
| 11 | S& F 200 mm internal dia reinforced concrete pipes class NP-2 laid and jointed complete with collars complete all as specified and directed. |
| 12 | S& F 150 mm internal dia reinforced concrete pipes class NP-2 laid and jointed complete with collars complete all as specified and directed. |
| 13 | Material & labour PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in benching ,kersbs compelet all as specified and directed. |
| 14 | Material & labour for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in foundation filling & mass concrete complete all as specified and directed. |
| 15 | Material & labour brick work with sub class ‘B’ modular bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 16 | Material & labour for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping for manhole including slightly rounded or chamfered angles and including necessary foRM work finishing exposed surface complete all as specified and directed. |
| 17 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds,stopped ends complete all as specified and directed. |
| 18 | Taking down cement plaster on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 19 | Material & labour for plastering 15 mm thick on brick walls masonary as fair face of cement mortar 1:4 surface finished fair and even complete all as specified and directed. |
| 20 | Cutting into existing manholes for connecting new sewage line / diverting some line to new manhole for smooth flow ; 150mm bore (internal dia of pipe ) incl making good to disturbed benching and haunching, plaster etc and foRMing new branch channel ( ½ round of ¾ section) if required in cement concrete 1:2:4 type B1 and smooth finished , reforming benching as required and complete all as specified and directed. |
| 21 | Returning filling in of excavated any type soil including spreading leveling watering and well ramming in layers n exc 25 cm thick, complete all as specified and directed. |
| 22 | Removal of surplus spoil/excavated material to a distance upto 50m and deposited, spread and leveled where not exc 1.5 M above the starting point complete all as specified and directed. |
| 23 | Material and labour for demolition of reinforced cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) complete all as specified and directed. |
| 24 | Material and labour for providing precast cement concrete Type B1 1:2:4 (20mm graded stone aggregate)as in cover slabs (for manholes, drains etc. of any size and thickness as required , Set in cement mortar 1:4 complete all as specified and directed. Note :- Reinforcement will be measured and paid saperately |
| 25 | Supply & fixing 6 to 8mm dia TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 26 | Supply & fixing in repair PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches or in floors inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed of following bore of pipe :- |
| 27 | (a) 110mm |
| 28 | (b) 75mm |
| 29 | Supply & fixing in repair PVC (SWR) pipes single socketed in any length with rubber rings joints laid in fixed to walls including clamps complete all as specified and directed. of the following bore of pipe:- |
| 30 | (a) 110mm |
| 31 | (b) 75mm |
| 32 | Supply & fixing PVC (SWR) junction single (single `T') equal or unequal with accessable door inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and as directed of the following bore:- |
| 33 | (a) 75mm |
| 34 | (b) 110mm |
| 35 | Supply & fixing in repair PVC (SWR) pipe bend with accessable door inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and as directed of the following bore:- |
| 36 | (a) 75mm |
| 37 | (b) 110mm |
| 38 | Supply & fixing in repair PVC (SWR) floor trap plain with SS grating including jointing with solvent cement and surrounding area of hole in floor to be filled with cement concrete type B-1 (1:2:4) complete all as specified and as directed of following bore :- |
| 39 | (a) 75mm |
| 40 | (b) 100mm |
| 41 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and as directed. |
| 42 | Material & labour 25 mm thick PCC 1:2:4 type B-1, using 20 mm graded stone aggregate, including finishing surface of concrete topping even and rough as in screed bed complete all as specified and as directed. |
| 43 | Material & labour for non skid-ceramic tiles coloured of size area of EACH tile exc.0.06 SQM but not exc . 0.11 SQM (300 x 300 mm) X 7mm thick in floors etc, set & jointed in neat cement slurry and pointed in white or colours cement to match over and including 15 mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed |
| 44 | Material & labour for glazed ceramic tiles coloured of size 300 x 450x 7 to 8mm or as directed by Engineer-In-Charge but will be measured in same item thick in walls etc, set & jointed in neat cement slurry and pointed in white or colours cement to match the colour of tiles over and including 10mm thick rendring in CM (1:4) complete all as specified and directed. |
| 45 | Supply & fixing in repair Vitreous China squatting pan “Orissa pattern” size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with CI ‘P’ trap of long aRM of suitable size including connection to flush pipe, anti symphonic pipes and bed concrete etc complete all as specified and as directed. |
| 46 | Supply & fixing in repair Vitreous China wash down water closet pan (Pedestal Pattern) and trap (standard pattern) coloured as approved including connection to drain (or outgoing pipe) and to flushing pipe anti symphonize pipe etc. including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and jointingcomplete with fixing bolts complete all as specified and as directed. |
| 47 | Supply & fixing in repair Plastic water closet seat,any colour as available, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and jointing complete all as specified and as directed. |
| 48 | Supply & fixing in repair Vitreous china half stall urinal flat back, with grating and union for discharge pipe fixed in repairs (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed. |
| 49 | Supply & fixing in repair Urinal spreader of PTMT any colour for fixing with 15mm dia pipe complete all as specified and as directed. |
| 50 | Supply & fixing 40mm low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm used as waste pipe in urinal / Wash hand basin complete all as specified and as directed. |
| 51 | Material and labour for cleaning of blockage in main / branch lines & connected manholes by manually / mechanically or using super sucker sewage cleaning machine including disposal of liquid/solid content out of the Mil area complete all as specified and directed for following dia of pipe :- |
| 52 | (i) 150mm bore |
| 53 | (ii) 200mm bore Please Enable Macros to View BoQ information |
| 54 | (ii) 200mm bore Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender