Tender For special Repair Of Feeder Piller Boxes Sub Stn Phulbari At Age Charduar (Mil Stn Thakurbari) Under Ge(N) Tezpur
Tender Value
45 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
12 days left
EMD
91000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Feeder Piller Boxes Sub Stn Phulbari At Age Charduar (Mil Stn Thakurbari) Under Ge(N) Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : SPL REPAIR OF FEEDER PILLER BOXES SUB STN PHULBARI AT AGE CHARDUAR (MIL STN THAKURBARI) UNDER GE(N) TEZPUR Contract No : GE(N)/TEZ/ OF 2026-2027 (File No. 8257) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe /Cables etc complete all as specified. |
| 3 | Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified and directed. |
| 4 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified and directed. |
| 5 | M&L for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed. |
| 6 | M&L laying well burnt old size bricks, sub calss \\"B\\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed. |
| 7 | M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed. |
| 8 | M & L for Earthing in replacement with galvanised steel pipe electrode, 40 mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4 mm dia galvanised iron wire all as shown in Plate No. 2 ( SSR Part-1) to the earthing test point all as specified and indicated , necessary excavation any type of soil, CI chamber cover 10 mm with 6 mm rod , wire mess, funnel, test point, 40 mm dia GI protection pipe medium grade etc complete and testing on completion all as specified and directed by Engr-in-charge . (Note :-(i) Fresh agriculture soil / black dirt or soil with a high organic conten will be used for filling the dug as required when rocky /sandy soil found at site to achieve the desired resistance from out side without any extra cost.(ii) Painting of earthing pit cover with synthetic enamel paint incl writing the earth resistance value on the same.) |
| 9 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 2 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 10 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 11 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 4 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 12 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 50 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 13 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 70 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 14 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 120 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 15 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 240 sqmm 3.5 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking up old unserviceable existing UG cable complete all as specified and directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this BOQ. |
| 16 | S&F in repairs Galvanised mild steel tubing of 32mm bore, 'Light grade' complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately) |
| 17 | S&F in repairs Galvanised mild steel tubing of 80mm bore, 'Light grade' complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately) |
| 18 | S&F in repairs Galvanised mild steel tubing of 100mm bore, 'Light grade' complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately) |
| 19 | Supply and fixing in repair Copper strip 20 x 3 mm fixed in ducts / on wall / in trenches / floors etc for earthing complete fixed to equipment / test point / earth electrode complete all as specified and directed. |
| 20 | Supply and fix in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white ,with letters and conventional skull and bone in postal red color and fixed with flat iron clamps, nuts, bolts , and washers of size 200mmx 150 mm for LT Note : (Note:-the printing shall be hand written only stancils embossing shall not be allowed ,and size of letter shall be 50x10 mm (height x width .) |
| 21 | Material and labour for PCC 1:4:8 type-D2 (using 40 mm graded crushed stone aggregate) Concrete 15cm Depth in bottom of Pit for bed concrete including necessory form work and finishing the surface fair and even without using extra cement including demolition of old unserviceable existing PCC works complete all as specified and directed |
| 22 | Material and labour for PCC 1: 2: 4 (using 20 mm graded crushed stone aggregate) for coping of above Ground level of steel pole including necessory form work and finishing the surface fair and even without using extra cement including demolition of old unserviceable existing PCC works complete all as specified and directed |
| 23 | Material and labour for PCC 1:3:6 type C-2 (using 20 mm graded crushed stone aggregate) for Cement concrete in foundations,filling and mass concrete. including necessory form work and finishing the surface fair and even without using extra cement including demolition of old unserviceable existing PCC works complete all as specified and directed |
| 24 | Supply, design, installation, connection, testing and commission factory made cubical, totally enclosed dust and vermin proof, fully compartmentalized , floor mounted and CPRI manufacturer ,Outdoor type LT distribution panel made out of 3.15mm thick CRCA steel sheet of suitable size with aluminium busbar of and fixed on floor with rigid base frame of MS IMC 125 (minimum) with and including anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) and all as per SSR part -I clause no 19.100 with and including suitable size copper pre-wired connection and complete all as specified and following accessories and components. : -BUS-BAR & INTERNAL CONNECTIONS:The bus-bars shall be made up of 04 Nos tinned alluminium 500 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.(a) INCOMING:-(i) MCCB 200A 4 pole 415 Volts, 50 Hz, 32KA (with ground fault protection) - 1 No(b) OUTGOING:-(i) MCCB 160 Amp, 3 pole ,415 Volts, 50 Hz, 25 KA (with ground fault protection) -2 Nos (ii) Motor protection relay with in-built CT and protection from thermal overload, single phasing, current unbalance, phase sequence reversal, locked rotor, earth fault and under current combined with selectable trip class for over current and trip time delay working on auxilliary supply voltage 240 volt AC and test facility- 01 Nos (iii) Automatic Star Delta starter for 330 LPM at 30 m head centrifugal pump - 01 Nos (for pump house near 106 Inf bde) (iv) Digital Ammeter 0-200A -01Nos with CTs & selector switch - 01 (v) Digital volmeter 0-500V -01nos. |
| 25 | Supply, install, testing & commissioning of LT panel board CPRI approved manufactrurer, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness size not less than (1.5x1.0x0.6)m, angle iron of size 50X50X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS:The bus-bars shall be made up of 04 Nos tinned alluminium 500 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.INCOMING :MCCB 4 pole, 415 Volts, 315 to 400 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS :MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete.MCCB 4 pole, 415 Volts, 250 Amps, 25 kA for out going -02 NosMCCB 4 pole, 415 Volts, 200 Amps, 25 kA for out going -01 Nos MCCB 4 pole, 415 Volts,63 Amps, 16 kA for out going -01 Nos INSTRUMENTATION SYSTEM :(a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(b) 3 Ph Digital Ammeter CI 1.0 - 01 No (c) 3 Ph Digital Voltmeter CI 1.0 - 01 No (d) Phase selector (Vertical) with rotary switches (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventionalskul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos.NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 26 | Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness size not less than (1.2x0.6x1.2)m, angle iron of size 40X40X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Cu bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS:The bus-bars shall be made up of 04 Nos tinned alluminium 400 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.INCOMING :MCCB 4 pole, 415 Volts, 250 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS :MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete.MCCB 4 pole, 415 Volts, 125 Amps, 25 kA for out going -01 NoMCCB 4 pole, 415 Volts, 100 Amps, 25 kA for out going -01 Nos MCCB 4 pole, 415 Volts,63 Amps, 25 kA for out going -03 Nos INSTRUMENTATION SYSTEM:(a) Indicator lamp with integral circuit (230/240V)&cluster LED (Red, Orange, Blue)-01 (b) 3 Ph Digital Ammeter CI 1.0 - 01 No (c) 3 Ph Digital Voltmeter CI 1.0 - 01 No (d) Phase selector (Vertical) with rotary switches (e) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventionalskul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos.NOTE : 1) Design / Drawing / BOM of the panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. Location: (i) Bde Office(ii)B COY T-5/2 (iii)CDR House (iv) coy Office T-11/3 (v) Bde offrs resi |
| 27 | Supply, install, testing & commissioning of LT busbar chamber of size (0.60x0.60x1.0)m CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 50X50X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS with a MCCB of 100amp capacity ,4pP with ICS=ICU=100%-1Nos. The bus-bars shall be made up of 04 Nos Aluminium 300 A rated not less than 60mmx10 mm, duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables.INSTRUMENTATION SYSTEM :(a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(b) 3 Ph Digital Voltmeter CI 1.0 - 01 No (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos.NOTE : 1) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 28 | Excavating in trenches, n exc 1.5 m wide and exc beyond 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out. |
| 29 | M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9metres long) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender