Tender For special Repair To Bldg No T-73, T-51B And T-37 Of 30 Rajput, T-11 (Oj Shelter Offr Living) Of 18 Mahar, T-103 (Ch & Dh) Of 154 Fd Regt Under Ge Kargil
Tender Value
39.96 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
16 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kargil → Jammu And Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Bldg No T-73, T-51B And T-37 Of 30 Rajput, T-11 (Oj Shelter Offr Living) Of 18 Mahar, T-103 (Ch & Dh) Of 154 Fd Regt Under Ge Kargil
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed. |
| 2 | Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work, complete all as specified and directed by Engr-in-Charge. |
| 3 | S&F second clas soft wood fillets square or rectangular in section sectional area exceeding 13 sq cm and n exc 25 sq cm as in scantling secured with nails or brads complete all as specified and directed. |
| 4 | S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls complete all as specified and directed. |
| 5 | S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in ceiling or sloping portion complete all as specified and directed. |
| 6 | S&F second class softwood moulding as in cornices, picture rails and the like sectional area not exceeding 6 Sqcm fixed with nails complete all as specified and directed. |
| 7 | M&L for Plain fillets of second class soft wood, sectional area n. exceeding 3 Sqcm square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed. |
| 8 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed. |
| 9 | S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified |
| 10 | S&F for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 11 | S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with with self tapping screw or L-type or J-type or cranked hook bolts as in roof, wall etc complete all as specified and as directed |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 13 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde- E- 250) quality- A complete all as specified and directed. |
| 14 | Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed. |
| 15 | S&F 4.8mm thick sheet glass ordinary quality and glazing with oil putty in squares exc 0.5 Sqm in each pane complete all as specified and directed. |
| 16 | S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified. |
| 17 | S&F in repair curtain rails anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc. complete all as specified. |
| 18 | M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer including preparation of surface. |
| 19 | M&L for preparing old steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 20 | Demolition of concrete of any description and in any position and removal of rocks/debris to a distance not exc 50 mtrs and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 21 | M&L for 75mm thick plain cement concrete 1:3:6. type C-2 (using 40mm graded aggregate) as in plinth protection and subbase to floors complete all as specified and directed. |
| 22 | M&L for chequered cement concrete tiles 300x300x25mm thick with grey cement and pigment and set jointed and pointed in neat cement slurry as in floor over 20 mm thick sreed bed or bedding layer in CM 1:4 complete all as specified and directed |
| 23 | Dismantling of floor hearth and wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises., complete all as specified and directed by Engr-in-Charge. |
| 24 | M&L Joint free Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.18 and n.exc 0.38 Sqm in floors over 15mm thick screed bed in cement mortar 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed |
| 25 | Taking down shutters of any description exc 1 sqm and n exc 2 sq. m each complete all as specified and directed. |
| 26 | S&F 30mm second class soft wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F But hinges, extruded aluminium alloy, with galvanised mild steel hinge pin, anodised and fixed, type B-21, size 100mm complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F aluminium alloy, anodised sliding door bolt with hasp staple ( bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed 300mm long. |
| 29 | S&F Aluminum Anodised barrel tower bolts of extruded section, 150mm long. |
| 30 | S&F anodised aluminium handle, cast type anodised section 150mm size complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F 0.56mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed commplete all as specified and directed |
| 32 | Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each without taking off shutters from the frames complete all as specified and directed by Engr-in-Charge. |
| 33 | Taking down shutters of any description, area n.exc 1 Sqm each complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F MS angle iron framed work as in doors or gates of angle or other section conforming to Fe 290(Gde E-165) with gusset plates, rails, braces, etc complete including hanging also fastening and fixing complete as specified and directed. |
| 35 | S&F 35mm thick plain framed second class soft wood (KAIL) panelled factory made shutters (two panel) with lock rail and panel of 9mm thick BWP commercial ply with size of rail and stiles as per IS 1003 (part-1), kin seasoned and chemically pressure treated all as specified and directed. |
| 36 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified in drawing on sl page No 156 of SSR 2010 part –II complete all as specified and directed |
| 37 | S&F in repair Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 38 | S&F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe- 410- WA (Gde E-250) quality A all as specified and directed. |
| 39 | S & Fmild steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 165 (Fe-290) complete all as specified and directed. |
| 40 | Excavation in post holes (or similar holes) in hard/dense soil each not exc 0.50 Cum and getting out returning, filling in and ramming earth around, in layers n exc 25 cm, watering and removing surplus soil to a distance not exc 50 Mtr and making good surfaces complete all as directed. |
| 41 | M&L for cemnt concrete 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregate as in foundation filling and mass concret complete all as specified and directed |
| 42 | S&F 5.5mm thick sheet glass ordinary quality in aluminium doors & windows with rubber packing & aluminium beading all as specified and directed |
| 43 | S&F in repair aluminium alloy wire cloth, 0.45mm nominal dia of wire & average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed. |
| 44 | S&F butt hinges med weight cold rolled MS, size 125 mm all as specified and as directed. |
| 45 | S&F Aluminium barrel tower bolts of extruded sectiont 100 mm long complete all as specified and direted |
| 46 | S&F extruded aluminum alloy handles, fabricated type and powder coated, 100mm size all as directed. |
| 47 | M&L for 02 coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description over 10cm width or girth including preparation of surfaces all as specified and directed. |
| 48 | M&L for PCC type B-1,1:2:4 (20mm graded aggregate) 25mm thick as in floor complete all as specified and directed. |
| 49 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation filling & mass concrete complete all as specified and directed |
| 50 | S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest including one CI 'P' or 'S' trap and providing lime concrete bedding and connecting to flusing cistern, complete all as specified and directed. |
| 51 | S&F in repairs vitreous china wash down water closet (pedestal pattern) white, including fixing bolts and necessary connection with existing pipes etc including PVC seat cover, flush pipe complete all as specified and directed. |
| 52 | S&F in repairs brass Chromium Plated Health faucet with spring pipe and rquired nipple all as speified and directed. Make: Jaquar Cat No ALD-CHR-585 or equivalent in makes Marc/Kohler. |
| 53 | S&F in repairs toilet paper holder with flat recessed type stainless steel all as specified and directed.Make : Jaquar cat No ACN 1153 N or equivalent in makes Marc/Kohler |
| 54 | S&F in repairs towel rail 600mm long brass Chromium plated 20mm dia all as specified and directed. |
| 55 | S&F in repair 10 Ltr capacity PVC low level flushing cistern, top push type with inlet ball valve, PVC float, brackets including superior quality PVC flush pipe of 32 mm dia, complete all as specified and directed. |
| 56 | S&F in repair 32 mm bore PVC waste pipe with fittings of approved make suitable for WHB, Urinals etc all as specified and directed. |
| 57 | S&F in repairs 32mm size waste fitting (coupling) brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed all as specified and directed. |
| 58 | S&F in repair PVC connection 15mm size with nuts of length 450mm complete all as specified and directed. |
| 59 | S&F in repair vitreous china wash basin white flat back size 550x400mm , including cutting for and pinning in ends of CI brackets or erecting stands etc. |
| 60 | S&F in repairs mild steel chromium plated curtain rod rod 25mm dia with fixing brackets, stopss and rollers etc all as specified and directed |
| 61 | S&F in repairs bib taps, cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe 15mm bore complete all as specified and directed. |
| 62 | S&F in repairs stop valves/angle valve, cast copper alloy fancy type chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore all as specified and directed |
| 63 | S&F in repairs Pillar taps cast copper alloy, fancy type, chromium plated with capstan heads screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe of 15 mm bore of complete all as specified and directed. |
| 64 | Dismentling of PVC/RCC water storage tank of capacity exceeding 250 litre but not exceeding 500 litre, including removal of rubbish outside MoD land, complete all as specified. |
| 65 | S&F Rotational moulded PVC, double layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, complete all as specified. |
| 66 | Taking down eaves gutter pipes, rain water pipes (of any size or pattern) including fittings, head shoes, bends, swan neck etc |
| 67 | S&F 75mm PVC (SWR) pipes single socketd, in any length with rubber ring joints laid in trenches or in floors by Engineer-in-Charge |
| 68 | S&F 110mm PVC (SWR) pipes single socketd, in any length with rubber ring joints laid in trenches or in floors by Engineer-in-Charge |
| 69 | S&F in repair 110mm bore PVC (SWR) bends any radius with access door complte all as specified and directed. |
| 70 | S&F in repair 75mm bore PVC (SWR) bends any radius with access door complte all as specified and directed. |
| 71 | S&F in repair 110mm bore PVC (SWR) bends any radius complte all as specified and directed. |
| 72 | S&F in repair 75mm bore PVC (SWR) bends any radius complte all as specified and directed. |
| 73 | S&F in repair PVC (SWR) floor trap 75mm dia outlet plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed. |
| 74 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 25 mm dia pipes complete all as specified and directed. |
| 75 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20 mm dia pipes complete all as specified and directed. |
| 76 | S&F 20mm outer diameter 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UVstabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 77 | S&F 25mm outer diameter 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UVstabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 78 | Demolition of brick work/stone boulder masonry, built in CM incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 79 | M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified & directed. |
| 80 | M&L 15mm thick rendering in cement mortar 1:4 to stone masonry wall surfaces including patches or on other than fair faces of brick masonary finished even and smooth without using extra cement. |
| 81 | M&L for PCC Type B2 1:2:4 (40 mm graded aggregate) as in surface channels and drains finished even and smooth without using extra cement complete all as specified and directed. |
| 82 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for and removing rubbish from premises, complete all as specified and directed. |
| 83 | M&L providing precast cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in cover slabs (for manholes etc) and shifting to different places and set in cement mortar 1:4 all as directed by Engineer-in-Charge. |
| 84 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slabs, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to TMT bars complete all as specified and directed. |
| 85 | S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap bent to curve, with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed. |
| 86 | All as per item No. 86 above but except sheeting complete all as specified and directed. |
| 87 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed |
| 88 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete incl 15mm thick screed bed in CM 1:4 complete all as specified and directed |
| 89 | S&F 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars,window cills,cooking platforms and like in cement mortar(1:4) including pointing in white cement(1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM(1:4) complete all as specified and directed. |
| 90 | S&F in repair stainless steel wash hand basin white counter type 570x450mm fixed on granite slab incl waste pipe, CP waste coupling, cutting for erecting granite slab, complete all as specified. |
| 91 | Dismantling water storage tanks of capacity exc 500 & n.exc 1000 ltrs and removing to store complete all as specified and as directed |
| 92 | S&F rotational moulded polyehtylene water storage tank of 1000 ltrs capacity (Cylindrical vertical with closed top) in position all as specified in SSR Part-I |
| 93 | M&L PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified & directed. |
| 94 | M&L for coloured glazed ceremic tiles in vertical surfaces 450x350x7mm thick, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15mm thick rendering in CM (1:4) complete all as specfied and directed. |
| 95 | M&L for 25 mm thick plain cement concrete 1:2:4. type B-0 (using 12.5 mm graded aggregate) as subbase to flooring complete all as specified and directed. |
| 96 | M&L for 75 mm thick plain cement concrete 1:3:6. type C-2 (using 40mm graded aggregate) as in plinth protection and subbase to floors complete all as specified and directed. |
| 97 | M&L for hardcore with broken stone or boulders of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified & directed. |
| 98 | Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and directed |
| 99 | M&L for Precast cement concrete type C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge. |
| 100 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.5 sq. m each complete all as specified and directed. |
| 101 | S&F second class softwood (KAIL) 30 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. complete all as specified. |
| 102 | S&F 3mm thick sheet glass ordinary quality and glazing with beading in squares n.exc 0.5 Sqm in each pane complete all as specified and directed. |
| 103 | M&L for second class softwood (KAIL), plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by Engr-in-Charge. |
| 104 | S&F 75mm butt hinges medium weight cold rolled mild steel fixed with screws or welded complete all as specified and directed. |
| 105 | S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 106 | S&F Angle Iron (and FI ,staging for water tank and the like including caps bases splices etc built up from two or more beam or channel section angle with plate including all lattice bars stiffenes gusset plate etc(Fe-290quality A). |
| 107 | S&F solid PVC door frame of size 50 mm x 47 mm made out of 5mm thick PVC sheet reinforced with mild steel square tube complete all as directed. |
| 108 | M&L for coloured non-skid ceramic tiles 7 to 8mm thick ( square / rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc set and set and jointed in neat cement slurry and pointed in white or coloured cement to match the work including 15 thick screed bed in CM ( 1:6) complete all as specfied and directed. |
| 109 | S&F in repairs stainless steel squatting pan of pattern “long pan”, size 580 x 440 mm with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified. |
| 110 | S&F in repair 15 mm bore bib taps standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 111 | S&F in repair 15mm bore dia angle valves of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 112 | S&F in repair 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed. |
| 113 | M&L for preparation of new plastered surfaces on walls and applying two coats of cement based paint over a coat of primer. |
| 114 | M&L for two coats of Oil bound distemper on old plastered surfaces of walls including preparation of surfaces. |
| 115 | M&L for RCC (1:1.5:3) using 20mm graded stone aggregate in slabs supported on walls, beams, complete all as specified. |
| 116 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick |
| 117 | M&L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work complete all as specified. |
| 118 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 119 | M&L rendering 15mm thick cement plaster in cement mortar (1:4) finished even & fair without using extra cement on brick/concrete surfaces complete all as specified and directed. |
| 120 | S&F suitable size chicken wire mesh to be fixed and firmly anchored to the concrete surface including 100mm lapping of all end sides all complete as per direction of Engineer-In Charge. |
| 121 | M&L for prepration of old plastered or unplastered surfaces of walls and applying two coats of cement base paint , complete all as specified and directed. |
| 122 | M&L for Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth. |
| 123 | M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, complete all as specified and directed |
| 124 | M&L for Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 125 | M&L for Point wiring for light/fan with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point controlled by one switch. |
| 126 | All as per Srl item No. 125 here in before but for one 3 pin 5 Amps socket outlet on same board. |
| 127 | All as per Srl item No 125 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 128 | All as per Srl item No 125 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 129 | S&F Switch piano flush type 5 Amps, single pole one way. |
| 130 | S&F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type. |
| 131 | S&F Switch socket combination 2 in 1, 5 and 15 Amps flush type. |
| 132 | S&F Socket Outlet 2 in 1, 5 Amp flush type |
| 133 | M&L of ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed. |
| 134 | S&F LED lights fitting, surface mounting general purpose ultra slim economical LED batten of 1x 18W, lumen out put 100lm/wattt, CCT:6500K/3000K , PF>0.9, in extruded PC housing and round/square shaped diffuser including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 135 | S&F in replacement LED light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up two core flexible copper conductor cable of suitable size. |
| 136 | S&F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 137 | S&F in replacement Sheet metal enclosure for DB's Single door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 138 | Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing Complete all as specified and directed. |
| 139 | Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SP 6 to 32 Amp in the MCB DB complete with connection testing Complete all as specified and directed. |
| 140 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete including connecting to ceilling rose with suitable size of cable all as specified and directed. |
| 141 | M&L for submain wiring comprising single core, 2 Runs of 6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 2mm thick PVC Casing Caping ISI Marked(heavy duty) and its fittings on surface/recessed complete including 1X6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS including taking down old UNSV submain wiring and making good the disturbed surface complete all as specified and directed by Engr-In-charge.(Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 142 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm×6.0mm thick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing on completion.Notes : (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate,(ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same. |
| 143 | S&F in replacement1100 volts grade heavy duty 16 Sqmm 2 core flat cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed. |
| 144 | Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250 mm including making arrangement for fixing Complete all as specified and directed. |
| 145 | Supply and fix in replacement exhaust fan made of sturdy Engineering Steel body complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of 300 mm sweep heavy duty including making arrangement for fixing Complete all as specified and directed. |
| 146 | M&L for submain wiring comprising single core ,2 Runs of 10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 2mm thick PVC Casing Caping ISI Marked(heavy duty) and its fittings on surface/recessed complete including 1X10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS including taking down old UNSV submain wiring and making good the disturbed surface complete all as specified and directed by Engr-In-charge.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 147 | Supply and fixing in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 148 | S & F in replacement Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 4 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 149 | Supply and fixing in replacement 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 32 Amp in the MCB DB complete with connection testing Complete all as specified and directed. |
| 150 | S & F in replacement .1100 volts grade heavy duty 10 Sqmm 2 core flat cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed. |
| 151 | Supply and fixing LED luminarie 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete 6000K/3000K with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver two core flexible copper conductor cases of suitable size complete. |
| 152 | Supply & laying or fixing and testing cross linked polytehylene (XLPE) LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 16 Sqmm 4 core and conforming to IS-7098(Part-I-1988 & as per latest amendments), laid in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles complete all as specified & directed. |
| 153 | Supply and Fix GI tubing light grade 40 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc. all as specified and as directed. |
| 154 | Excavation in trenches, hard/ dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of hard soil & laying of cable complete all as specified and directed |
| 155 | Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 156 | Returning filling, including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified. |
| 157 | Supply & laying or fixing and testing of DWC (Double Wall Corrugated) duct pipe (HDPE) of size 63 x 50 mm laid in trench/ducts/under roads/under hard standing/along poles complete all as specified & directed. |
| 158 | Note : Deduction for amount of Rs. 71595.95 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysJul 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender