Tender For Repair/Maint To Roof Sheet At Hangar, Rolling Shutters, Chemical Based Flooring, Rain Water Pipe, Parking Area, Footpath In East Wing At Af Stn Gwalior
Tender Value
47.98 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
19 days left
EMD
95960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gwalior → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint To Roof Sheet At Hangar, Rolling Shutters, Chemical Based Flooring, Rain Water Pipe, Parking Area, Footpath In East Wing At Af Stn Gwalior
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws to hangar roof at 12 to 20mtr height including Dismantling of existing plain or corrugated steel complete all as specified and directed. |
| 2 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, Ridge, valley/ gutter fixed with self tapping screws to hangar roof at 12 to 20mtr height including Dismantling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed. |
| 3 | M&L for 0.63mm thick Plain, galvanised, mild steel sheeting, as in valley gutters, drip at crumples in required shape and size and straight flashings (length and girth as fixed) with grade of zinc coating 275 and making special shape to connect rain water pipe fixed with self tapping screws at any height exc. 10 mtr and n.exc 20 mtr including Dismantling of existing sheet complete all as specified and directed. |
| 4 | S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc including dismantling of existing sheet complete all as specified and directed. |
| 5 | S&F in repair for Hand rails, half round or other steel section or wind ties for roof including securing bolts; |
| 6 | M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including dismantling of old MS work complete confirming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 7 | S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; including fixed with angle cleats or other connecting plate etc confirming to Fe-290 Gde-E-165 complete including dismantling of old MS work all as specified and as directed. |
| 8 | Easing/ adjusting & repairing of sliding doors of Aircraft hangers of size exceeding 18 Sqm but n.exc. 45 Sqm of each shutter by providing welding, oiling, greasing, etc all necessary arrangements required for smooth sliding and locking of the sliding door complete all as specified and directed by EIC. Note : Supply of unserviceable parts shall be measured and paid separately |
| 9 | Repair and maintenance of existing pulley of any description and in any position at height not exc. 15m with or without taking down existing pulleys, ascertaining serviceability, ensuring smooth functioning of pulleys including greasing, oiling etc and replacement of minor parts like screws, nut & bolts, washers etc and fixing the same in existing position with necessary welding, riveting, etc complete all as specified and directed. Note : Scaffolding for repair of pulleys upto any height shall be deemed to inlcude in the unit rate quoted by the contractor. |
| 10 | Easing/ adjusting & repairing of roller gates of various sizes by providing welding, oiling, greasing, etc all necessary arrangements required for smooth sliding complete all as specified and directed by EIC. Note : Supply of unserviceable parts shall be measured and paid separately |
| 11 | Supply only MS wheels, pintels, axles of required size and parts required for pulleys / wheels for aircraft hanger doors and roller gates with bearing and all as specified and directed. Note : Labour rates are inlcuded in Item No 8, 9 & 10) |
| 12 | S&F in repairs steel rolling shutters (thickness of laths 1.25mm) with out ball bearing, as specified including top cover, anchoring rod, springs, guide channel & hasp and staple and erected in position as indicated push pull and manual type, complete all as specified and directed. |
| 13 | S&F in repairs steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, springs, guide channel & hasp and staple and erected in position as indicated gear operated type, complete all as specified and directed. |
| 14 | Repair, maintenance of existing rolling shutter of any description and in any position without taking down existing rolling shutter, removing hood covers, acertaining serviceablity of existing parts, removing unserviceable parts and replacement with new one, fixing the existing serviceable parts in their position for ensuring smooth functioning of the rolling shutters including greasing, oiling, etc and replacement of minor parts like screws, nuts, bolts, washers, etc and fixing the parts (new or old) in existing position with necessary welding, reveting, etc & refixing complete all as specified and directed by Engineer-in-charge. Note:- Supply only new parts shall be measured and paid separately under appropriate items of Sch 'A' |
| 15 | Supply only guide channels made of not less than 2mm thick mild steel sheeting depth 50 to 150mm ( as required at site) and width of guide channel 25mm including providing fixing cleats or supports with spacing not exc. 0.75m complete all as specified and directed. |
| 16 | Supply only fabricated 1.25mm thick MS sheet rolling strip of size 75 to 100mm wide and shape as required at site for rolling shutter incl cutting, punching to made required shape and size each alternative lath section shall be fitted with MS clips and complete all as specified and directed. |
| 17 | Supply only flat spring suitable for various sizes of heights and all as specified and directed. |
| 18 | Supply and fixing 40mm dia medium weight mild steel pipe as in supspnsion shafts complete all as specified and directed. |
| 19 | Supply & fixing hood covers made of 1.00 mm thick mild steel plaint cut to size holes, punched and spot welded to steel including bending or turning, mitred angles etc as required complete all as specified and directed |
| 20 | Supply only MS spring wheel alongwith spring of any size with MS bush fixed with shaft for rolling shutters complete all as specified and directed. |
| 21 | Supply only of pinion set (local name Garari) suitable for rolling shutters complete all as speciifed and directed by Engineer-in-charge. |
| 22 | S&F in repairs bevel gear box for gear operated type rolling shutter (Mechanical type) made of high grade cast iron or mild steel with handle complete all as specified and directed. |
| 23 | Supply only fabricated bracket plate of mild steel sheet 3.15mm thick size (as per IS for different heights) and shape not exc, 0.50 sqm for mechanically operated rolling shutter complete all as specified and directed. |
| 24 | S&F in repairs fabricated lock plate made of MS flat 35 x 6mm and 400mm long sliding plate with arrangement for locking with pad locks and providing pulling handles of mild steel fixed on both the interior and exterior side of lock plate complete all as specified and directed |
| 25 | M&L preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer over 10m width or girth complete all as specified and directed. |
| 26 | S&F in repairs stainless steel turbo ventilator including fixing base fibre glass reinforced translucent corrugated profile sheet fixed with self taping screws in hangar roof complete all as specified and directed. |
| 27 | Running welding to existing MS steel door, rail, channel, cleats etc at any position at any height n.exc 100 mm on prority as and when directed by Engr-in-Charge. |
| 28 | Taking down chowkats or frames with shutters exceeding 1.50 Sqm but not exceeding 4 Sqm each (Aluminum Doors/ windows) without taking off shutters from the frames including builders hardware & glass etc complete all as specified & directed. |
| 29 | Taking down chowkats or frames with shutters not exceeding 1.50 Sqm each (Aluminum Doors/windows) without taking off shutters from the frames including builders hardware & glass etc complete all as specified & directed. |
| 30 | S&F UPVC luxury casement sound proof side Hung (Openable) windows with frame, DGU (double glazed unit) (5T+12+5T) toughned glass (one glass transparent and one glass tinted) with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc, junction of wall and frame sealed with sealent complete all as specified and as directed by Engr-in-Charge. |
| 31 | S&F UPVC luxury casement sound proof fixed type windows/Ventilators and frame with DGU (double glazed unit) (5T+12+5T) toughned glass (one glass transparent and one glass tinted) including necessary builders hardware etc, junction of wall and frame sealed with sealent complete all as specified and as directed by Engr-in-Charge. |
| 32 | S&F UPVC sound proof door frame with shutter and DGU (double glazed unit) (5T+12+5T) toughned glass (one glass transparent and one glass tinted) with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc, junction of wall and frame sealed with sealent complete all as specified and as directed by Engr-in-Charge. |
| 33 | S&F Powder coated aluminium frame for door, window, ventilators and partitions with extruded built up standard tubular sections with necessary jointing aluminium cleats using C.P./ stainless steel screws, all as specified and directed by Engr-in-Charge. |
| 34 | S&F Powder coated aluminium door shutters with extruded built up standard tubular sections using aluminium sec not less than 2 mm thick, (shutter with styles 85mmX44.45mm, top rails 83.5mmX44.45mm , intermediate rail 83.5mmx44.45mm, bottom rail 114.3mmx44.5mm) with aluminium beading and rubber neoprene paking for fixing glass, including all fittings such as hinges, towerl bolts, handles and sliding bolt and necessary locking arrangements all as specified and directed by Engr-in-Charge. |
| 35 | S&F 5mm thick tinted glass, and glazing in squre/rectangular aluminium shutters /frames complete all as specified and directed. |
| 36 | S&F 4mm thick ACP (Aluminium composite pannel) coloured sheet with 0.25 mm thick of aluminium coil, sandwitch pannel as in alumiium doors/wall claddings with sealent and necessary hidden screws complete all as specified and directed. |
| 37 | Demolition of cement concrete ( unreinforced) ground floors and pavings n. exc 15 cm thick below or above ground level and removing the demolished material to a distance exc 500 m but not exceeding 1.5 km and depositing where directed, complete all as specified and directed. |
| 38 | Dismantling of floor, hearth or wall tilling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed. |
| 39 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and directed incl demolition of brick work or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed. |
| 40 | All as per above here-in-before but except bricks |
| 41 | M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 42 | M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth without using extra cement including taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 43 | M&L for Preparation of newly plaster surface of wall and applying two coat of distemper oil emulsion over a coat of calk whitening (preparatory to distempering) white or tinted as approved all as specified and directed. |
| 44 | M&L for Preparation of newly plastered surface and applying two coat of weather coat exterior emultion white or tinted over a coat of primer as approved complete all as specified and directed. |
| 45 | M & L for 25 mm thick cement concrete 1:2:4 type B-0 ( using 12.5mm graded stone aggregate) as in leveling course sub base complete all as specified and directed. |
| 46 | M & L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in cills, steps; seismic and other similar bands, plinth courses, water troughs, ducts and like incl necessary formwork etc and all as directed. |
| 47 | M&L for 8 to 10mm thick vitrified ceramic coloured tiles (square/ rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles over 15mm th screed bed in CM 1:6 complete all as specified and directed. |
| 48 | All as per above here-in-before but as in skirting/dado but 10mm thick cement plaster1:4 as backing coat complete including dismantling of old tiles all as specified and directed. |
| 49 | M&L for glazed ceramic coloured tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on brick work or concrete surface in cement moratar 1:4 complete including dismantling of old tiles all as specified and directed. |
| 50 | S&F in repair 3 mm thick PVC tiles /sheets, laminated plain coloured, marbled mosaic or mottled finish laid with approved rubber based adhesive in floors including all cutting and waste and work in all position complete all as specified and directed. Make: Wonder floor, Marvel Vinyl, Premier etc |
| 51 | S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square in each pane with suitable glazing pins in each pane at any height of Hangar widows/vents including Hacking out old broken glass (any thickness, size, quality or description) from steel frames, glazed with putty or fixed complete |
| 52 | S&F in repairs 0.70mm dia galvanised steel wire netting of mess size12mm fixed with tinned tacks of wire staples in patches to hangar bird proofing net at 10 to 15 mtr height complete all as specified and directed by Engr-in-Charge. |
| 53 | Taking down old 160mm dia PVC (SWR)/Rain water pipes and refixing the same in its position with proper clamping fixed to wall/cladding, laid inside hangar ceiling duct at any height, laid on roofs etc with 2 mm thick GI brackets fabricated type complete all as specified and directed by Engr-in charge. |
| 54 | S&F in repairs 160mm dia PVC (SWR)/Rain water pipes with rubber ring joints with solvent cement single socketed fixed to wall/cladding, laid inside hangar ceiling duct at any height, laid on roofs etc with 2 mm thick GI brackets fabricated type complete all as specified and directed by Engr-in charge. |
| 55 | S&F in repairs 160mm dia PVC (SWR) bend with rubber ring joints at any height. |
| 56 | S&F in repairs 160mm dia PVC (SWR) couplers with rubber ring joints at any height fixed to walls/ hanger cladding. |
| 57 | M&L for Preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 58 | M&L for Preparation of old decorated surface of wall include brooming down with steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, including filling the cracks and depressions and applying one coat of distemper oil emulsion with roller white or tinted as approved complete all as specified and directed. |
| 59 | M & L for complete removal of existing painting on epoxy flooring surface and applying two coats of polyurethane based paint over a coat of primer to lines, dashes, arrows, letters etc of colour as approved by users and GE complete as directed by EIC |
| 60 | M&L preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer over 10m width or girth (in camouflaged pattern color / tint as approved by GE) complete all as specified and directed. |
| 61 | M&L for 75 mm thick plain cement concrete (1:3:6) type C2, using 40 mm graded stone aggregate as in path/sub base etc complete all as specified and directed. |
| 62 | M&L for 60 mm thickness Machine pressed precast concrete interlocking paver block any shape and size of M-35 Grade confirming to IS 15658-2006 with grey cement and no pigment complete all as specified and as directed. |
| 63 | M&L for Sand filling under floors to receive interlocking paver blocks incl consolidation complete all as specified and as directed. |
| 64 | M&L for 100 mm thick plain cement concrete (1:2:4) type B2, using 40 mm graded stone aggregate as in pavings/hard standings and finishing cement concrete surface even & fair,laid in alternate panels complete all as specified and directed. |
| 65 | M&L for 75 mm thick plain cement concrete (1:3:6) type C2, using 20 mm graded stone aggregate as in Plinth protection and finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 66 | Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc all as directed. |
| 67 | M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following |
| 68 | One light/ Fan point controlled by one way switch. |
| 69 | One 5 Amps switch socket combination on independent board. |
| 70 | One 5 Amps socket on same board with other switches. |
| 71 | All as per item here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed. |
| 72 | S&F in repairs Modular switch 1 way 6A, 1 module single pole 230 V. |
| 73 | S&F in repairs Modular type switch socket out let 3 pin 6 Amps flush type 230 Volts multipurpose, |
| 74 | All as per item here-in-before above but 6 Amps and 16 Amps multipurpose( 3 Pin 16 Amps and one pin 6 Amps controlled by one switch) |
| 75 | S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge. |
| 76 | S&F ceiling rose surface backelet ISI marked , 2 to 3 terminal all as specified and directed. |
| 77 | S&F in repairs lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge. |
| 78 | M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface in PVC casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and casing caping shall be measured as one unit. |
| 79 | M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface in PVC casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and casing caping shall be measured as one unit. |
| 80 | M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor shall be measured as one unit. |
| 81 | M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating 1100 Volts drawn in drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor shall be measured as one unit. |
| 82 | Supply, fixing, connecting & testing of sheet metal enclosures single pole and neutral with a two pin earth plug and socket complete with one single pole 20 amp MCB complete all as specified and directed. |
| 83 | Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pin earth plug and socket complete with one TPN 32 Amp MCB complete all as specified and directed |
| 84 | Supply, fixing in repair connecting & testing of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed. |
| 85 | All as per item here-in-before but distribution board single pole and neutral, 12 way complete all as specified and directed. |
| 86 | All as per item here-in-before but distribution board single pole and neutral, 8 way complete all as specified and directed. |
| 87 | All as per item here-in-before but distribution board single pole and neutral, 4 way complete all as specified and directed. Please Enable Macros to View BoQ information |
| 88 | All as per item here-in-before but distribution board single pole and neutral, 4 way complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 days