Tender For annual repair maintenance E&M Services Of Home For Mentally Retarded And Old Age Person, Asha Kiran Complex, Avantika, Rohini, Delhi (Sh: Balance Work Of Split Ac And Window Ac Installation & miscellaneous Work)
Tender Value
12.99 Lakhs
Estimated cost
Bid Submission
04 Jul 2026
3 days left
EMD
25982
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for annual repair maintenance E&M Services Of Home For Mentally Retarded And Old Age Person, Asha Kiran Complex, Avantika, Rohini, Delhi (Sh: Balance Work Of Split Ac And Window Ac Installation & miscellaneous Work)
BOQ
| Sl. No. | Item Description |
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).a) 1.8 TR - 2.0 TR with 5 Star BEE Rating minimum cooling capacity 6300 Watt |
| 2 | Supplying &Fixing of 4 KVA capacity automatic voltage stabilizer with time delay relay and high/low\ voltage trip facility input voltage 150V to 290V and output voltage 220+10% with copper flexible cable connection etc. as required at site. (For 1.5 Ton Ac) |
| 3 | Supplying & Fixing of 5 KVA capacity automatic voltage stabilizer with time delay relay and high/low voltage trip facility having voltage range 150 V to 280 V +10% with copper flexible cable connection i/c mounting of stabilizer unit with cutting of existing board frame & mounting arrangement etc. as reqd at site. (For 2 TR AC) |
| 4 | Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 5/8\\"and 3/8\\" suitable for 1.5/2 TR STAC duly insulated by nitrile rubber, covered with MS pipe for safety of the pipe along with necessary support, clamps, brackets as required as per site requirement. |
| 5 | Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 1/2\\"and 1/4\\" suitable for 1.5/2 TR STAC duly insulated by nitrile rubber, covererd with MS pipe for safety of the pipe along with necessary support,clamps,brackets as required as per site requirement. |
| 6 | Supplying of following accessories for the existing 1.5 TR/ 2 TR. capacity WTAC / STAC unit, using existing man power for replacement on day to day maintenance work: a) 15 Amp 3 Pin plug Top (ISI Marked) |
| 7 | b) 3 core PVC insulated PVC sheathed copper wire 2.5 Sq.mm copper flexible |
| 8 | Pdg. & Fixing of following heavy duty PVC drain pipe for draining of condensate to a safer disposal point in recess/ surface i/c cutting the chase in the wall and making good the same with cement work etc. complete as required. (a) 25 mm dia |
| 9 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 11 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 12 | b) 25 mm |
| 13 | Supplying and fixing of following sizes of U-PVC feeder trunking with cover whereever necessary as per length of run on the existing wall i/c band, tee, Coupler, Elbow and others items etc. as required at site. a) 100 mm x 50 mm |
| 14 | Installation of ACs Unit following as per location opening, plywood, frame, cutting wall, window etc suitable for window unit with 1.5 TR/2.0 TR capacity i/c Wall making good plaster, white wash if any, connection, testing and commissioning etc. complete as reqd. |
| 15 | Credit for following old/dismantle material received from above work i/c dismantling & removal from site.a) Assorted Window/Split Type Air Conditioner Unit 1.5/2 TR |
| 16 | b) Copper Pipe/Cables Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 days