Science and Technology Statutory Bodies & Commissions/Committees Closing in 5 days TDR #56213754

Tender For Supply, Installation, Testing And Commissioning Of Vrf/Vrv Air Conditioning System In Green Building, At Csir-Neeri Nagpur.

Issued by Statutory Bodies & Commissions/Committees · Nagpur, Maharashtra
Tender Value
45.69 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
5 days left
EMD
91500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing And Commissioning Of Vrf/Vrv Air Conditioning System In Green Building, At Csir-Neeri Nagpur.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Jul-2026 Revision in Technical specification compliance sheet Technical Bid 21-Jul-2026

BOQ

Name of Work:- Supply, Installation, Testing and Commissioning of VRF/VRV air conditioning system in Green Building, at CSIR-NEERI Nagpur.
Sl. No. Item Description
1VRF/VRV OUTDOOR UNIT: Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building) For Cooling or Heating or Both
2For COOLING or HEATING or BOTH
3VRF/VRV INDOOR UNIT: Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19 °C WB temperature. (Make will be same as of Outdoor)
41.6 TR
52.0 TR
62.6 TR
73.6 TR
84.1 TR
9CENTRALIZED MONITORING UNIT FOR VRV/VRF AIR CONDITIONING SYSTEM: Supply and installation of centralized monitoring unit for all the connected Indoor & Outdoor units of VRF/VRV air conditioning system and complete testing of the same as per requirement and recommended model by Original Equipment manufacturer of VRF/VRV air conditioning system manufacturer
10COPPER REFRIGERANT PIPING: Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
119.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
1212.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
1315.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
1419.0 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
1522.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
1625.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
1728.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
1831.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
1934.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
2038.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
2141.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm
22ELECTRIC CABLE (Size: 16.0 Sq. MM, 4-Core): Supply and fixing of PVC ARMOURED Cables, Size: 16.0 Sq. MM, 4-Core, with COPPER Conductor, 650/1100 V Grade confirming to IS:7098 (Pt-1) 1988 for the electrical connections of VRF/VRV Air conditioner Outdoor Units as per site conditions and complete as required Make: ISI Marked manufacturer
23ELECTRIC CABLE (Size: 2.5 Sq. MM, 3-Core): Supply and fixing of PVC round sheathed multicore industrial cables (FRLS) for voltage grade upto 1100V as per IS694:IS2010 , Size: 2.5 Sq. mm, 3-Core, Copper Conductor (Multistrand), using UPVC conduit pipe (for heavy mechanical stress) Dia. Size: 19 mm, for the electrical connections of VRF/VRV Air conditioner Indoor Unit as per site conditiones and complete as required. Make: ISI Marked manufacturer
24ELECTRICAL CABLE (Size: 0.5 Sq. MM, 2-Core): Supply and fixing of PVC round sheathed multicore industrial cables (FRLS) for voltage grade upto 1100V as per IS694:IS2010 , Size: 0.5 Sq. mm, 2-Core, Copper Conductor (Multistrand), using UPVC conduit pipe (for heavy mechanical stress) Dia. Size: 19 mm, for the electrical connections of VRF/VRV Air conditioner Indoor Unit as per site conditiones and complete as required. Make: ISI Marked manufacturer
25COMMUNICATION CABLE (FOR INDOOR AND OUTDOOR CONNECTIONS): Supply and fixing of communication cable, Size: 0.75 Sq. mm, 2-Core, Copper Conductor (Multistrand), Shielded , using UPVC conduit pipe (for heavy mechanical stress) Dia. Size: 19 mm, for connecting VRF/VRV Outdoor and Indoor Unit as per site conditions and complete as required. Make: ISI Marked manufacturer
26ADDITIONAL REFRIGERANT CHARGING (TOP UP): Supply of a refrigerant and Gas charging work using Refrigerant (R410a/R407) in VRF/VRV Air Conditioning system as per required quantity/pressure and standard operating procedure recommended by the original equipment manufacturer, complete as required.
27FABRICATION OF M.S. STAND/STRUCTURE: Fabrication of M.S. Angle Stands/structure of suitable size and approved Design for the installation of Outdoor Units of VRF/VRV air conditioning system, duly painted with two coats of Red Oxide and One Coat Enamel Paint and complete as required
28DRAIN PIPE (RIGID UPVC): Supply and fixing of rigid UPVC drain pipe (as per Schedule 40) for drain water piping connections of VRV/VRF indoor unit, including required fittings, clamping, adhesive for fixing joints as per site requirement and instructions given by Engineer. Make: ISI marked manufacturer
29OUTSIDE DIAMETER 25.00 mm
30OUTSIDE DIAMETER 40.00 mm
31SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF ULTRASONIC RODENT REPELLENT SYSTEM AS PER FOLLOWING TECHNICAL SPECIFICATIONS
32CONTROLLER: SITC of Microprocessor based Master Controller with 128X64 Graphic LCD DISPLAY capable of operating in 5 ultrasonic frequency band spectrums. The LCD should display oscillation between these freqency bands in a graphical format. The controller should also support upto 20 transducers @ minimum 500 sq.ft each and networkable on RS 485 having facility to support Hardwired Third Party BMS integration via Modbus & potential free NO-NC contacts.
33TRANSDUCERS: SITC of transducer Sound Output: 50 db to 100 db (Variable), Area Coverage per Transducer: 500 Sq. Feet (Above False Ceiling), Operating Frequency: Above 20 Khz
34Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs
35For Indoor Units
36For Outoor Units
37Hot Dipped Galvanized Iron Cable Tray: Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. Make: ISI Marked manufacturer
38150 mm width X 50 mm depth X 1.6 mm thickness
39225 mm width X 50 mm depth X 1.6 mm thickness
40300 mm width X 62.5 mm depth X 2.0 mm thickness
41450 mm width X 62.5 mm depth X 2.0 mm thickness
42BUY-BACK VALUE OF OLD VRF/VRV AIR CONDITIONING SYSTEM: Bidder has to quote a Buy-back value of old VRF/VRV air conditioning system, Make: VOLTAS, presently installed in Green Building at CSIR-NEERI, Nagpur is having total Four (04) nos. of outdoor units (Top discharge air cooled type), Model No. VIV-V500W/ZR1-B, & Capacity of each Outdoor Unit: 18 HP and total Twenty-one (21) nos. of Indoor units (4 way - cassette type) cooling capacity: 1.5 TR to 3.6 TR including complete dismantling of all Indoor and Outdoor units, copper piping, electrical cables, water drain pipes, communication cable, centralized remote controller, MS Fabricated stands, Cable trays etc. as per standard operating procedure recommended by the Original Equipment Manufacturer and shifting of dismanted material complete as required Note: This VRF/VRV air conditioning system is installed in Green Building at CSIR-NEERI, Nagpur. Bidder may visit for the physical inspection of the system to analise its buy-back value. THe bidder shall be responsible for the safe dismantliing, packing and transporatation of the old buy back equipment from CSIR-NEERI Nagpur at his own cost.
43COMPREHENSIVE MAINTENANCE OF VRF/VRV AIR CONDITIONING SYSTEM FOR THE DURATION OF (05) YEARS: Comprehensive maintenance work of complete VRF/VRV air conditioning system for the duration of Five (05) years as per following scope of work SCOPE OF WORK: a. All the Indoor and Outdoor units will be serviced after every Three (03) months, as per standard procedure, recommended by the Original Equipment Manufacturer (OEM) b. All the breakdown calls related to VRF/VRV air conditioning system will be attended and resolved satisfactorily within a specified time limit. c. Comprehensive maintenance of Ultrasonic Rodent repellent system for the protection of complete VRF/VRV air conditioning system from rodents Note: The date of expiry of defect liability period of the work will be considered as a date of start of this item work. Payment for this item work will be done on Half-yearly basis i.e. for every Six (06) months period, after successful completion of maintenance work and submission of work reports for the billing period. Cost of all the spare parts/consumables, required manpower for the maintenace of VRF/VRV air conditioning system and Ultrasonic Rodent repellent system will be arranged by the contractor on its own cost. No extra charges will be paid by CSIR-NEERI for the same.
44COMPREHENSIVE MAINTENANCE WORK - For First Year (after completion of Defect Liability Period)
45COMPREHENSIVE MAINTENANCE WORK - For Second Year (after completion of Defect Liability Period)
46COMPREHENSIVE MAINTENANCE WORK - For Third Year (after completion of Defect Liability Period)
47COMPREHENSIVE MAINTENANCE WORK - For Fourth Year (after completion of Defect Liability Period)
48COMPREHENSIVE MAINTENANCE WORK - For Fifth Year (after completion of Defect Liability Period) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56213754
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45.69 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Supply, Installation, Testing And Commissioning Of Vrf/Vrv Air Conditioning System In Green Building, At Csir-Neeri Nagpur.
Basic Detail
Tender No 50(85)/2025-26/W
Bidding Type Tender
Location
City Nagpur
State Maharashtra
Key Dates
Publish Date 01 Jul 2026
Submission Date 21 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 45.69 Lakhs
Tender Fee Ref. Documents
EMD 91500
Exemption Not Available
Document List
450b256b-8e66-4583-86a9-fbe5105e0b10.html
BOQ_329412.xls
NIT-merged.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

450b256b-8e66-4583-86a9-fbe5105e0b10.html

xls

BOQ_329412.xls

pdf

NIT-merged.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders