Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 18 days TDR #56213749

Tender For Annual Rate Contract (Arc) For Maintenance Of Cathodic Protection (Cp) And Associate System For Sonipat, Meerut And Dewas For 2 Years

Issued by Boards / Undertakings / PSU · Ghaziabad, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Jul 2026
18 days left
EMD
3.82 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Rate Contract (Arc) For Maintenance Of Cathodic Protection (Cp) And Associate System For Sonipat, Meerut And Dewas For 2 Years

BOQ

Name of Work:- ANNUAL RATE CONTRACT (ARC) FOR MAINTENANCE OF CATHODIC PROTECTION (CP) AND ASSOCIATE SYSTEM FOR SONIPAT, MEERUT AND DEWAS FOR 2 YEARS
Sl. No. Item Description
1Supply & Installation of Manual Test Station complete with lower bend and with PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC.
2Supply & Installation of Manual Test Station with out lower bend & with out PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC.
3Shifting of Manual Test Station along with foundation and cable to suitable location as per instruction of EIC. (Excluding additional Cable if required).
4Repairing of Manual Test Stations foundation with supply and replacement of foundation bolts and nuts including labour,tools,tackles consumeables like cement,sand aggregates etc complete in all respect as per scope of work, specifications and direction of EIC.
5Repairing of Manual Test Stations including supply and replacement of damaged door, door locks,terminal plate ,diagram plate,neoprene gasket, brass links cable identification ferrules etc in Manual Test Station with proper cable termination, cable jointing,lugs with numbering of Test Station complete in all respect including labour,tools,tackles,consumeables like MS /brass bolts, nuts, washers,insulation tape etc.as per scope of work, specifications and the direction of EIC.
6Supply & replacement of damaged/missing locks in Manual Test Station including labor, consumables, tools & tackles as per drawings, specifications & instructions of EIC.
7Supply & replacement of damaged/missing doors in Manual Test Station including lock,neoprene gasket, diagram plate labor, consumables , tools & tackles as per drawings, specifications and instructions of EIC.
8Supply & installation of damaged/missing terminal plates (all types) with M10 brass studs, washers, links, lugs & nuts, tools & tackles and consumables including labor as per instruction of EIC.
9Supply and Fixing of diagram plate in the existing test station of all types complete in all respect including labour,tools,tackles ,consumeables etc. as per scope of work specifications and the direction of EIC.
10Supply, installation, testing and commissioning of Anode Lead Junction Box (ALJB) including required backelite plate brass nut bolts, port type resistor & shunt arrangement, civil works with materials as per EIC.
11Repairing of ALJB including supply of new locks and latch for the outer enclosure, shunt, variable resistance, brass links, ALJB doors including welding mechanical, fittings, hinges, labour, tools tackles, consumables like lugs, MS/Brass nuts, bolts, washers, insulation tape etc complete in all respect as per approved drawings,specification and as per direction of EIC.
12Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 4 sq mm Cable.
13Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 6 sq mm Cable.
14Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 10 sq mm Cable.
15Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 16 sq mm Cable.
16Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 25 sq mm Cable.
17Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 35 sq mm Cable.
18Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 4 SQ MM
19Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 6 SQ MM
20Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 10 SQ MM
21Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 16 SQ MM
22Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 25 SQ MM
23Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 35 SQ MM
24Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 4 sq mm
25Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 6 sq mm
26Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 10 sq mm
27Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 16 sq mm
28Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 25 sq mm
29Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 35 sq mm
30Making of Pipe to cable connection as per approved proedure, of all types of cable including excavation and backfilling, surface preparation, pipe to cable connection by means of pin brazing its encapsulation, holiday testing of the exposed section, labour, tools, tackles etc as per scope of work, specifications and direction of EIC .
31Painting of Manual Test station including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
32Painting of Anode Lead Junction Box (ALJB)including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
33Painting of TR/CPPSM Units including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
34Supply & replacement of copper-copper sulphate permanent refrenece cells (Make Mc Miller/ Tinker & Rasor / Caproco) necessary backfill material including excavation /backfilling cable laying,cable identification ferrules,labour, tools, tackles, consumables like sand, brick,lug,Brass washers,insulation tape etc,complete in all respects as per scope of work drawings, specification and direction of EIC.
35Supply of portable Cu-CuSO4 Half cell for measuring of PSP (Pipe to Soil Potential) of Pipeline.
36Supply & installation of explsoin proof spark gap arrestors make across insulating joints at SV/IP/RR/terminals including required cable, lugs, nuts & bolts, labor, tools & tackles, and sundry consumables.
37Supply, Installation and Commissioning of Polarization Cell / Solid State Decoupler (SSD) along with the enclosure suitable for housing of Polarization Cells in all respect as per specification & directions of Engineer In charge. (Supply of cable, cable laying upto the test station, Cable Joint to pipe & Zn anode for grounding shall be treated as seperate, if required). Sonipat
38Preventive Maintenence of Polarisation cells supply of KOH electrolyte / Solid State Decoupler (SSD), complete in all respect to make the cell in working condition and as per specifications and instructions of EIC.
39Supply and installation of pre-packed Magnesium anodes with cable having weight 17 pounds including excavation, backfilling, cable laying up to test station and cable temination in test station, cable identification ferrules, with consumables labour etc. as per approved drawing, specification and direction of EIC.
40Supply,replacement & installation of prepacked High Silicon Chromiunm/Iron Solid Anodes(22kg) of reputed make including excavation, backfilling, anode to tail cable connection, cable identification, coke breeze backfill complete with labor, tools & tackles as per drawings, specifications & instructions of EIC (item is applicable for Normal AGE not for Deep Well AGB)
41Supply and Installation of pre packed Zinc grounding cell 22Kg (H-Type) including all tools, tackles, consumables, labour chemical back fill, excavation, backfilling, cable to insert joint , laying of tail cable, cable temination at TS complete and in all respect as per drawing, specification and asp er direction of EIC.
42Supply and Installation of pre packed Zinc Grounding Anode (Weight: 17 lbs) including all tools, tackles, consumables, labour ,chemical back fill, excavation, backfilling, cable to insert joint , laying of tail cable, cable termination at TS complete and in all respect as per drawing, specification and as per direction of EIC.
43Supply, installation,Testing and Commissioning of Deep Well Anode Ground Bed (MMO Titanium anodes).
44Preventive maintenance of Anode Ground Bed -The scope of work includes necessary excavation for carrying out ground bed curing with 500 kg of common salt and water of 18 KL. The work includes necessary backfilling and restoration to the original condition as per the direction of EIC. The contractor shall measure the grounded resistance after the treatment of ground bed. The resistance of grounded after the maintenance shall be less than 01 ohm.
45Supply, installation, comissioning of earthpits as per scope of work & enclosed drawing and specififcations including supply and installation of of GI Pipe earth electrode, salt, charcoal, sand and brick masonary work,excavation and backfilling in all type of soils and MS cover at the top.
46Half-yearly Monitoring of Earthpits: Resistance measuring of earth-pit, pouring of water to bring down the resistance if required, painting, numbering and cleaning of connecting nuts and bolts, etc as per directions of EIC
47Recharging of existing earth pits. Job includes supply of new GI Pipes, material and consumables, transportation of material and manpower, painting of top cover plates and numbering, recharging of earth pit by pouring sufficient salt, charcoal and water in it for bringing down the circuit resistance including making, necessary excavation, backfilling etc complete in all respect and as per directions of EIC.
48Chamber Repair of Earth Pit. Job includes reconstruction of Earth pit chamber with raising the height of civil foundation, repair of cement plastering, painting of top cover plates and numbering the earthpit, charging the earth pit with common salt 50 Kg and water 100L for bringing down the circuit resistance including making necessary excavation, mixing & pouring of salt & water, replacement & cleaning of connecting nuts and bolts, etc complete in all respect and as per directions of EIC
49Earthpit chamber MS Cover 600 X 600 X 5 mm (Approx)
50Supply and installation of cable markers for underground cables and equipment as per the specifications.
51Carrying out on-off Close Interval Potential Logging (CIPL) Survey with Lateral Gradient at one meter interval using data loggers and standard Cu/CuSO4 Reference Electrode and as per the specifications.
52Carryingout Direct Current Voltage Gradient (DCVG)/ ACVG survey using standard DCVG/ACVG equipment to pin point the coating defect/holidays on pipeline as per the specifications.
53Stray current Interference survey at railway crossing or runnig parallel to GAIL Gas Pipelines, including 24 hours data logging,data collection from railways,study the effectiveness of existing diode bonding and recommend mitigation measures /modification required at existing doide JB, at all the railway crossings or running parallel as defined in scope of work with specification,design and detail engineering.
54Stary current Interference survey at foreign P/L crossing or runnig parallel with GAIL Gas Pipeline,including 24 hours data logging,data collection from foreign pipeline operator,and recommend mitigation measures at foreign pipeline crossing or runnig parallel to GAIL pipeline as defined in the scope of work,with design,specification and detail enggineering.
55Stray current Interference survey at HT crossings or runnig parallel to GAIL Gas Pipelines,including 24 hours data logging,collection of data from UHBVN, calculation of human touch and step voltages,measurent and calculation of AC corrossion current and recommendation for mitigation/effectiveness of existing grounding with modification if required, at HT Line crossings /parallel sections as defined in the scope of work with design,specification and detail enggineering.
56Excavation & Backfilling of pipeline in all type of soils and ordinary rocks for a width of D+500 mm on each side of pipe and exposing the pipeline from top upto 500mm below the bottom of Pipeline including the stacking of excavated earth ,lead upto 50m,stacked earth to be levelled and neatly dressed 'as per the scope of work and directions of EIC.
57Coating repair, Removing the old/ damaged coating/rust greese,moisture and all foreign material at defect material with scrapper,manual surface preparation using hand wire brush ,emery paper,scrappers or a combination of all processes,repairng of the coating with supply of raychem sleeves/cold applied tape/PERP/patch repair kit ,holiday testing after repair,as per the scope of work and to the entire satisfaction of EIC .Multiple patch repairing at one location within one meter span shall be trated as single quantity only.(Compensation if required to land owners shall be in the scope of contractor)
58Repair & Rectification of TR Unit and CPPSM: To carry out breakdown maintenance of cathodic protection equipments like TR units, CPPSM units. EIC will issue instructions for breakdown maintenance to be carried out. Immediately upon receiving such orders, the contractor shall make necessary arrangements and submit schedules thereof in line with the time frame given by the EIC.The scope of work includes tracing out the fault in the system, carrying out necessary repair and rectification, supply of component level spares for repairing the cards and making the unit operational in all respect. The contractor should attend the break down call with in 24 Hrs. Breakdown maintenance will be carried out by the contractor under the guidelines and instructions of the EIC and as per drawing and manual.
59Quarterly Monitoring and Collection of data related to CP System from Manual Test Stations along the pipeline route including compilation and preperation of the reports in the office by a technically qualified person.Quarterly monitoring includes On-Off Potential Survey using current Interrupters once in a year. Total length of pipeline is approximately 103 Km and rates to be quoted on quarterly basis. Monitoring of MTSs (120 Nos in Sonipat CGD) are for eight quarters.
60Monthly Monitoring and Collection of data from TR / CPPSM Units including compilation and preperation of the reports in the office by a technically qualified person. Total numbers of TR/CPPSM unit is 1 (one). Monitoring of CPPSM/TR units are for 24 (twenty four) months.
61Half-yearly Monitoring and Collection of data related to CP System from Anode Ground bed including compilation and preperation of the reports in the office by a technically qualified person.
62Annual Monitoring and Collection of data related to CP System from Reference electrodes including compilation and preperation of the reports in the office by a technically qualified person.
63Mandatory spares of Kriston System TR Unit : Control Card RRL-103A.
64Mandatory spares of Kriston System TR Unit : Spare Control Card RRL-104C1.
65Mandatory spares of Kriston System TR Unit : Control Card RRL-105D1.
66Mandatory spares of Kriston System TR Unit : Control Card RRL-106.
67Mandatory spares of Kriston System TR Unit : Control Card RRL-118C.
68Lightning Arrestors for Kriston System TR Unit /CPPSM Unit.
69Transeducers for Kriston MAKE TR/CPPSM Units (PSP, O/P Voltage,O/P Current,I/P Voltage,I/P Current)
70Panel Meters for Kriston MAKE TR/CPPSM Units.
71Supply and Installation of Kriston Make Solid State Polarisation Cell for AC De-coupling & AC Interference Suppression for Pipelines
72Design of Anode Ground Bed including Soil Resistivity Survey for specified locations
73CAT survey of Un-Piggable Pipelines at every 10M Interval with Field data analysis at every 500-meter interval by plotting Pipeline Map current v/s Distance on graph sheets / Field computer for immediate on-site review including recording of elevation profile of entire pipeline at 10M as well as depth survey recording at every 10M. Submission of draft report along with data to GAIL GAS for each pipeline section, Dig Verification & Completion of Validation surveys, Completion of all survey work, submission of final reports and printed reports for all sections.
74IJ SUPPLY JOINT,INSULATING, DESIGN PRESSURE- 49 Kg/cm2(g), DESIGN TEMP- 0°C to 65°C, BUTT-WELD AT BOTH ENDS, DESIGN CODE- ASME SECTION-VIII DIV-I, CORROSION ALLOWANCE-1.5 MM, HYDROSTATIC TEST PRESSURE- 76 Kg/cm2(g), CHARPY TEST(BODY, WELDING ENDS)- As per ASTM A 370, HARDNESS TEST REQUIRED AS PER SPEC.BIDDER HAS TO QUOTE & SUPPLY INSULATING JOINT, TEST CERTIFICATE OF THE PRODUCT TO BE PROVIDED WITH THE MATERIAL.GAIL GAS MAY WITNESS TEST & DO PRE DISPATCH INSPECTION OF MATERIAL.
754 IN, BODY-ASTM A-694, F-52, PUPS- API 5L GR. X-52, 6.4 mm THK.(MIN.)
762 IN, BODY-ASTM A-694, F-52, PUPS- API 5L GR. X-52, 6.4 mm THK.(MIN.)
7710 IN, BODY-ASTM A-694, F-52, PUPS- API 5L GR. X-52, 6.4 mm THK.(MIN.)
78Supply, Installation & Commissioning of Earth Pits as per scope of work & enclosed drawing (Drawings No.- MEC/SD/05/E9/02/02 ) and specifications including supply and installation of copper plate, GI Pipe, salt, charcoal, sand and brick masonry work, excavation and backfilling in all type of soils and MS cover at the top. (Earthing Cable/ strip extra).
79Supply & Laying/ Erection of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) including all associated civil work/ restoration and labour for Grid Fabrication of Existing Earth Pits as per IS 3043.
80Testing of Insulation Joints by using Radio Frequency IJ Tester1.Contractor shall carryout testing of Insulation Joints to find shorting of Insulation Joints to find out shorting of Insulation Joints by using Radio Frequency IJ Tester.2.RF IJ Tester for carrying out IJ testing is in the scope of the Contractor. 3.Contractor shall provide Test Certificate of RF IJ tester before carrying out testing job.
81Supply & Installation of Manual Test Station complete with lower bend and with PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC.
82Supply & Installation of Manual Test Station with out lower bend & with out PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC.
83Shifting of Manual Test Station along with foundation and cable to suitable location as per instruction of EIC. (Excluding additional Cable if required).
84Repairing of Manual Test Stations foundation with supply and replacement of foundation bolts and nuts including labour,tools,tackles consumeables like cement,sand aggregates etc complete in all respect as per scope of work, specifications and direction of EIC.
85Repairing of Manual Test Stations including supply and replacement of damaged door, door locks,terminal plate ,diagram plate,neoprene gasket, brass links cable identification ferrules etc in Manual Test Station with proper cable termination, cable jointing,lugs with numbering of Test Station complete in all respect including labour,tools,tackles,consumeables like MS /brass bolts, nuts, washers,insulation tape etc.as per scope of work, specifications and the direction of EIC.
86Supply & replacement of damaged/missing locks in Manual Test Station including labor, consumables, tools & tackles as per drawings, specifications & instructions of EIC.
87Supply & replacement of damaged/missing doors in Manual Test Station including lock,neoprene gasket, diagram plate labor, consumables , tools & tackles as per drawings, specifications and instructions of EIC.
88Supply & installation of damaged/missing terminal plates (all types) with M10 brass studs, washers, links, lugs & nuts, tools & tackles and consumables including labor as per instruction of EIC.
89Supply and Fixing of diagram plate in the existing test station of all types complete in all respect including labour,tools,tackles ,consumeables etc. as per scope of work specifications and the direction of EIC.
90Supply, installation, testing and commissioning of Anode Lead Junction Box (ALJB) including required backelite plate brass nut bolts, port type resistor & shunt arrangement, civil works with materials as per EIC.
91Repairing of ALJB including supply of new locks and latch for the outer enclosure, shunt, variable resistance, brass links, ALJB doors including welding mechanical, fittings, hinges, labour, tools tackles, consumables like lugs, MS/Brass nuts, bolts, washers, insulation tape etc complete in all respect as per approved drawings,specification and as per direction of EIC.
92Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 4 sq mm Cable.
93Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 6 sq mm Cable.
94Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 10 sq mm Cable.
95Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 16 sq mm Cable.
96Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 25 sq mm Cable.
97Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 35 sq mm Cable.
98Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 4 SQ MM
99Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 6 SQ MM
100Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 10 SQ MM
101Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 16 SQ MM
102Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 25 SQ MM
103Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 35 SQ MM
104Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 4 sq mm
105Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 6 sq mm
106Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 10 sq mm
107Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 16 sq mm
108Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 25 sq mm
109Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 35 sq mm
110Making of Pipe to cable connection as per approved proedure, of all types of cable including excavation and backfilling, surface preparation, pipe to cable connection by means of pin brazing its encapsulation, holiday testing of the exposed section, labour, tools, tackles etc as per scope of work, specifications and direction of EIC .
111Painting of Manual Test station including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
112Painting of Anode Lead Junction Box (ALJB)including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
113Painting of TR/CPPSM Units including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
114Supply & replacement of copper-copper sulphate permanent refrenece cells (Make Mc Miller/ Tinker & Rasor / Caproco) necessary backfill material including excavation /backfilling cable laying,cable identification ferrules,labour, tools, tackles, consumables like sand, brick,lug,Brass washers,insulation tape etc,complete in all respects as per scope of work drawings, specification and direction of EIC.
115Supply of portable Cu-CuSO4 Half cell for measuring of PSP (Pipe to Soil Potential) of Pipeline.
116Supply & installation of explsoin proof spark gap arrestors make across insulating joints at SV/IP/RR/terminals including required cable, lugs, nuts & bolts, labor, tools & tackles, and sundry consumables.
117Supply, Installation and Commissioning of Polarization Cell / Solid State Decoupler (SSD) along with the enclosure suitable for housing of Polarization Cells in all respect as per specification & directions of Engineer In charge. (Supply of cable, cable laying upto the test station, Cable Joint to pipe & Zn anode for grounding shall be treated as seperate, if required). Meerut
118Supply and installation of pre-packed Magnesium anodes with cable having weight 17 pounds including excavation, backfilling, cable laying up to test station and cable temination in test station, cable identification ferrules, with consumables labour etc. as per approved drawing, specification and direction of EIC.
119Supply and Installation of pre packed Zinc grounding cell 22Kg (H-Type) including all tools, tackles, consumables, labour chemical back fill, excavation, backfilling, cable to insert joint , laying of tail cable, cable temination at TS complete and in all respect as per drawing, specification and asp er direction of EIC.
120Supply and Installation of pre packed Zinc Grounding Anode (Weight: 17 lbs) including all tools, tackles, consumables, labour ,chemical back fill, excavation, backfilling, cable to insert joint , laying of tail cable, cable termination at TS complete and in all respect as per drawing, specification and as per direction of EIC.
121Supply, installation,Testing and Commissioning of Deep Well Anode Ground Bed (MMO Titanium anodes).
122Preventive maintenance of Anode Ground Bed -The scope of work includes necessary excavation for carrying out ground bed curing with 500 kg of common salt and water of 18 KL. The work includes necessary backfilling and restoration to the original condition as per the direction of EIC. The contractor shall measure the grounded resistance after the treatment of ground bed. The resistance of grounded after the maintenance shall be less than 01 ohm.
123Supply, installation, comissioning of earthpits as per scope of work & enclosed drawing and specififcations including supply and installation of of GI Pipe earth electrode, salt, charcoal, sand and brick masonary work,excavation and backfilling in all type of soils and MS cover at the top.
124Half-yearly Monitoring of Earthpits: Resistance measuring of earth-pit, pouring of water to bring down the resistance if required, painting, numbering and cleaning of connecting nuts and bolts, etc as per directions of EIC
125Recharging of existing earth pits. Job includes supply of new GI Pipes, material and consumables, transportation of material and manpower, painting of top cover plates and numbering, recharging of earth pit by pouring sufficient salt, charcoal and water in it for bringing down the circuit resistance including making, necessary excavation, backfilling etc complete in all respect and as per directions of EIC.
126Chamber Repair of Earth Pit. Job includes reconstruction of Earth pit chamber with raising the height of civil foundation, repair of cement plastering, painting of top cover plates and numbering the earthpit, charging the earth pit with common salt 50 Kg and water 100L for bringing down the circuit resistance including making necessary excavation, mixing & pouring of salt & water, replacement & cleaning of connecting nuts and bolts, etc complete in all respect and as per directions of EIC
127Earthpit chamber MS Cover 600 X 600 X 5 mm (Approx)
128Supply and installation of cable markers for underground cables and equipment as per the specifications.
129Carrying out on-off Close Interval Potential Logging (CIPL) Survey with Lateral Gradient at one meter interval using data loggers and standard Cu/CuSO4 Reference Electrode and as per the specifications.
130Carryingout Direct Current Voltage Gradient (DCVG)/ ACVG survey using standard DCVG/ACVG equipment to pin point the coating defect/holidays on pipeline as per the specifications.
131Stray current Interference survey at railway crossing or runnig parallel to GAIL Gas Pipelines, including 24 hours data logging,data collection from railways,study the effectiveness of existing diode bonding and recommend mitigation measures /modification required at existing doide JB, at all the railway crossings or running parallel as defined in scope of work with specification,design and detail engineering.
132Stary current Interference survey at foreign P/L crossing or runnig parallel with GAIL Gas Pipeline,including 24 hours data logging,data collection from foreign pipeline operator,and recommend mitigation measures at foreign pipeline crossing or runnig parallel to GAIL pipeline as defined in the scope of work,with design,specification and detail enggineering.
133Stray current Interference survey at HT crossings or runnig parallel to GAIL Gas Pipelines,including 24 hours data logging,collection of data from MSEB, calculation of human touch and step voltages,measurent and calculation of AC corrossion current and recommendation for mitigation/effectiveness of existing grounding with modification if required, at HT Line crossings /parallel sections as defined in the scope of work with design,specification and detail enggineering.
134Excavation & Backfilling of pipeline in all type of soils and ordinary rocks for a width of D+500 mm on each side of pipe and exposing the pipeline from top upto 500mm below the bottom of Pipeline including the stacking of excavated earth ,lead upto 50m,stacked earth to be levelled and neatly dressed 'as per the scope of work and directions of EIC.
135Coating repair, Removing the old/ damaged coating/rust greese,moisture and all foreign material at defect material with scrapper,manual surface preparation using hand wire brush ,emery paper,scrappers or a combination of all processes,repairng of the coating with supply of raychem sleeves/cold applied tape/PERP/patch repair kit ,holiday testing after repair,as per the scope of work and to the entire satisfaction of EIC .Multiple patch repairing at one location within one meter span shall be trated as single quantity only.(Compensation if required to land owners shall be in the scope of contractor)
136Repair & Rectification of TR Unit and CPPSM: To carry out breakdown maintenance of cathodic protection equipments like TR units, CPPSM units. EIC will issue instructions for breakdown maintenance to be carried out. Immediately upon receiving such orders, the contractor shall make necessary arrangements and submit schedules thereof in line with the time frame given by the EIC.The scope of work includes tracing out the fault in the system, carrying out necessary repair and rectification, supply of component level spares for repairing the cards and making the unit operational in all respect. The contractor should attend the break down call with in 24 Hrs. Breakdown maintenance will be carried out by the contractor under the guidelines and instructions of the EIC and as per drawing and manual.
137Quarterly Monitoring and Collection of data related to CP System from Manual Test Stations along the pipeline route including compilation and preperation of the reports in the office by a technically qualified person.Quarterly monitoring includes On-Off Potential Survey using current Interrupters once in a year. Total length of pipeline is approximately 89 Km and rates to be quoted on quarterly basis. Monitoring of MTSs (125 Nos in Meerut CGD) are for eight quarters.
138Monthly Monitoring and Collection of data from TR / CPPSM Units including compilation and preperation of the reports in the office by a technically qualified person. Total numbers of TR/CPPSM unit is 3 (Three). Monitoring of CPPSM/TR units are for 24 (twenty four) months.
139Half-yearly Monitoring and Collection of data related to CP System from Anode Ground bed including compilation and preperation of the reports in the office by a technically qualified person.
140Annual Monitoring and Collection of data related to CP System from Reference electrodes including compilation and preperation of the reports in the office by a technically qualified person.
141Mandatory spares of Raychem RPG TR Unit : Control Card RRL-103A.
142Mandatory spares of Raychem RPG TR Unit : Spare Control Card RRL-104C1.
143Mandatory spares of Raychem RPG TR Unit : Control Card RRL-105D1.
144Mandatory spares of Raychem RPG TR Unit : Control Card RRL-106.
145Mandatory spares of Raychem RPG TR Unit : Control Card RRL-118C.
146Lightning Arrestors for Raychem RPG TR/CPPSM Unit.
147Transeducers for Raychem MAKE TR/CPPSM Units (PSP, O/P Voltage,O/P Current,I/P Voltage,I/P Current)
148Panel Meters for Raychem MAKE TR/CPPSM Units.
149CAT survey of Un-Piggable Pipelines at every 10M Interval with Field data analysis at every 500-meter interval by plotting Pipeline Map current v/s Distance on graph sheets / Field computer for immediate on-site review including recording of elevation profile of entire pipeline at 10M as well as depth survey recording at every 10M. Submission of draft report along with data to GAIL GAS for each pipeline section, Dig Verification & Completion of Validation surveys, Completion of all survey work, submission of final reports and printed reports for all sections.
150IJ SUPPLY JOINT,INSULATING, DESIGN PRESSURE- 49 Kg/cm2(g), DESIGN TEMP- 0°C to 65°C, BUTT-WELD AT BOTH ENDS, DESIGN CODE- ASME SECTION-VIII DIV-I, CORROSION ALLOWANCE-1.5 MM, HYDROSTATIC TEST PRESSURE- 76 Kg/cm2(g), CHARPY TEST(BODY, WELDING ENDS)- As per ASTM A 370, HARDNESS TEST REQUIRED AS PER SPEC.BIDDER HAS TO QUOTE & SUPPLY INSULATING JOINT, TEST CERTIFICATE OF THE PRODUCT TO BE PROVIDED WITH THE MATERIAL.GAIL GAS MAY WITNESS TEST & DO PRE DISPATCH INSPECTION OF MATERIAL.
1514 IN, BODY-ASTM A-694, F-52, PUPS- API 5L GR. X-52, 6.4 mm THK.(MIN.)
1522 IN, BODY-ASTM A-694, F-52, PUPS- API 5L GR. X-52, 6.4 mm THK.(MIN.)
15310 IN, BODY-ASTM A-694, F-52, PUPS- API 5L GR. X-52, 6.4 mm THK.(MIN.)
154Supply, Installation & Commissioning of Earth Pits as per scope of work & enclosed drawing (Drawings No.- MEC/SD/05/E9/02/02 ) and specifications including supply and installation of copper plate, GI Pipe, salt, charcoal, sand and brick masonry work, excavation and backfilling in all type of soils and MS cover at the top. (Earthing Cable/ strip extra).
155Supply & Laying/ Erection of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) including all associated civil work/ restoration and labour for Grid Fabrication of Existing Earth Pits as per IS 3043.
156Testing of Insulation Joints by using Radio Frequency IJ Tester1.Contractor shall carryout testing of Insulation Joints to find shorting of Insulation Joints to find out shorting of Insulation Joints by using Radio Frequency IJ Tester.2.RF IJ Tester for carrying out IJ testing is in the scope of the Contractor. 3.Contractor shall provide Test Certificate of RF IJ tester before carrying out testing job.
157Supply & Installation of Manual Test Station complete with lower bend and with PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC.
158Supply & Installation of Manual Test Station with out lower bend & with out PCC foundation including terminal plate, diagram plate, cable identification ferrules and proper cable termination with lugs, numbering of Test Station etc. as per drawing & specification (with IP55) complete in all respect and per instruction of EIC.
159Shifting of Manual Test Station along with foundation and cable to suitable location as per instruction of EIC. (Excluding additional Cable if required).
160Repairing of Manual Test Stations foundation with supply and replacement of foundation bolts and nuts including labour,tools,tackles consumeables like cement,sand aggregates etc complete in all respect as per scope of work, specifications and direction of EIC.
161Repairing of Manual Test Stations including supply and replacement of damaged door, door locks,terminal plate ,diagram plate,neoprene gasket, brass links cable identification ferrules etc in Manual Test Station with proper cable termination, cable jointing,lugs with numbering of Test Station complete in all respect including labour,tools,tackles,consumeables like MS /brass bolts, nuts, washers,insulation tape etc.as per scope of work, specifications and the direction of EIC.
162Supply & replacement of damaged/missing locks in Manual Test Station including labor, consumables, tools & tackles as per drawings, specifications & instructions of EIC.
163Supply & replacement of damaged/missing doors in Manual Test Station including lock,neoprene gasket, diagram plate labor, consumables , tools & tackles as per drawings, specifications and instructions of EIC.
164Supply & installation of damaged/missing terminal plates (all types) with M10 brass studs, washers, links, lugs & nuts, tools & tackles and consumables including labor as per instruction of EIC.
165Supply and Fixing of diagram plate in the existing test station of all types complete in all respect including labour,tools,tackles ,consumeables etc. as per scope of work specifications and the direction of EIC.
166Supply, installation, testing and commissioning of Anode Lead Junction Box (ALJB) including required backelite plate brass nut bolts, port type resistor & shunt arrangement, civil works with materials as per EIC.
167Repairing of ALJB including supply of new locks and latch for the outer enclosure, shunt, variable resistance, brass links, ALJB doors including welding mechanical, fittings, hinges, labour, tools tackles, consumables like lugs, MS/Brass nuts, bolts, washers, insulation tape etc complete in all respect as per approved drawings,specification and as per direction of EIC.
168Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 4 sq mm Cable.
169Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 6 sq mm Cable.
170Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 10 sq mm Cable.
171Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 16 sq mm Cable.
172Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 25 sq mm Cable.
173Supply of 660/1100V grade single core ,stranded tinned copper conductor cables,XLPE insulated,PVC sheathed armoured cables of following sizes as per scope of work , specifications and direction of EIC. Size: 1C X 35 sq mm Cable.
174Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 4 SQ MM
175Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 6 SQ MM
176Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 10 SQ MM
177Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 16 SQ MM
178Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 25 SQ MM
179Cable laying of given Size ( XLPE armoured cable) inside the test station / over ground & under ground/inside the panel including excavation and backfilling, cable laying cable jointing above ground using copper sleeves, termination of cable in test station / panel, cable identification, supply & laying of bricks, sand etc including tools tackles, labour, consumables as per scope of work, specifications and the direction of EIC : Size : 1 C x 35 SQ MM
180Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 4 sq mm
181Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 6 sq mm
182Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 10 sq mm
183Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 16 sq mm
184Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 25 sq mm
185Cable jointing/ repairing of underground cable as per approved procedure including excavation and backfilling, cable jointing by cable jointing kit (raychem/equivalent), termination & identification of cables, supply of cable jointing kit & other consumable, labour, tools, tackles, copper sleeves, heat shrink sleeves, ferol etc. for given Cable Size XLPE armoured Cu cable as per scope of work , specifications and directions of EIC. Size: 1 C x 35 sq mm
186Making of Pipe to cable connection as per approved proedure, of all types of cable including excavation and backfilling, surface preparation, pipe to cable connection by means of pin brazing its encapsulation, holiday testing of the exposed section, labour, tools, tackles etc as per scope of work, specifications and direction of EIC .
187Painting of Manual Test station including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
188Painting of Anode Lead Junction Box (ALJB)including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
189Painting of TR/CPPSM Units including removing of old paint, rust etc, surface preparation to get the smooth level surface, supply and application of 01 coat of ready mix red oxide primer of approved make, 02 coats of ready mixed first quality paint of approved brand. (Final dry paint thickness not less than 100 micron), Numbering of Test Station as per scope of work, specification and as per direction of EIC.
190Supply & replacement of copper-copper sulphate permanent refrenece cells (Make Mc Miller/ Tinker & Rasor / Caproco) necessary backfill material including excavation /backfilling cable laying,cable identification ferrules,labour, tools, tackles, consumables like sand, brick,lug,Brass washers,insulation tape etc,complete in all respects as per scope of work drawings, specification and direction of EIC.
191Supply of portable Cu-CuSO4 Half cell for measuring of PSP (Pipe to Soil Potential) of Pipeline.
192Supply & installation of explsoin proof spark gap arrestors make across insulating joints at SV/IP/RR/terminals including required cable, lugs, nuts & bolts, labor, tools & tackles, and sundry consumables.
193Supply, Installation and Commissioning of Polarization Cell along with the enclosure suitable for housing of Polarization Cells in all respect as per specification & directions of Engineer In charge. (Supply of cable, cable laying upto the test station, Cable Joint to pipe & Zn anode for grounding shall be treated as seperate, if required). DEWAS
194Preventive Maintenence of Polarisation cells supply of KOH electrolyte, complete in all respect to make the cell in working condition and as per specifications and instructions of EIC.
195Supply and installation of pre-packed Magnesium anodes with cable having weight 17 pounds including excavation, backfilling, cable laying up to test station and cable temination in test station, cable identification ferrules, with consumables labour etc. as per approved drawing, specification and direction of EIC.
196Supply,replacement & installation of prepacked High Silicon Chromiunm/Iron Solid Anodes(22kg) of reputed make including excavation, backfilling, anode to tail cable connection, cable identification, coke breeze backfill complete with labor, tools & tackles as per drawings, specifications & instructions of EIC (item is applicable for Normal AGE not for Deep Well AGB)
197Supply and Installation of pre packed Zinc grounding cell 22Kg (H-Type) including all tools, tackles, consumables, labour chemical back fill, excavation, backfilling, cable to insert joint , laying of tail cable, cable temination at TS complete and in all respect as per drawing, specification and asp er direction of EIC.
198Supply and Installation of pre packed Zinc Grounding Anode (Weight: 17 lbs) including all tools, tackles, consumables, labour ,chemical back fill, excavation, backfilling, cable to insert joint , laying of tail cable, cable termination at TS complete and in all respect as per drawing, specification and as per direction of EIC.
199Supply, installation,Testing and Commissioning of Deep Well Anode Ground Bed (MMO Titanium anodes).
200Preventive maintenance of Anode Ground Bed -The scope of work includes necessary excavation for carrying out ground bed curing with 500 kg of common salt and water of 18 KL. The work includes necessary backfilling and restoration to the original condition as per the direction of EIC. The contractor shall measure the grounded resistance after the treatment of ground bed. The resistance of grounded after the maintenance shall be less than 01 ohm.
201Supply, installation, comissioning of earthpits as per scope of work & enclosed drawing and specififcations including supply and installation of of GI Pipe earth electrode, salt, charcoal, sand and brick masonary work,excavation and backfilling in all type of soils and MS cover at the top.
202Half-yearly Monitoring of Earthpits: Resistance measuring of earth-pit, pouring of water to bring down the resistance if required, painting, numbering and cleaning of connecting nuts and bolts, etc as per directions of EIC
203Recharging of existing earth pits. Job includes supply of new GI Pipes, material and consumables, transportation of material and manpower, painting of top cover plates and numbering, recharging of earth pit by pouring sufficient salt, charcoal and water in it for bringing down the circuit resistance including making, necessary excavation, backfilling etc complete in all respect and as per directions of EIC.
204Chamber Repair of Earth Pit. Job includes reconstruction of Earth pit chamber with raising the height of civil foundation, repair of cement plastering, painting of top cover plates and numbering the earthpit, charging the earth pit with common salt 50 Kg and water 100L for bringing down the circuit resistance including making necessary excavation, mixing & pouring of salt & water, replacement & cleaning of connecting nuts and bolts, etc complete in all respect and as per directions of EIC
205Earthpit chamber MS Cover 600 X 600 X 5 mm (Approx)
206Supply and installation of cable markers for underground cables and equipment as per the specifications.
207Carrying out on-off Close Interval Potential Logging (CIPL) Survey with Lateral Gradient at one meter interval using data loggers and standard Cu/CuSO4 Reference Electrode and as per the specifications.
208Carryingout Direct Current Voltage Gradient (DCVG)/ ACVG survey using standard DCVG/ACVG equipment to pin point the coating defect/holidays on pipeline as per the specifications.
209Stray current Interference survey at railway crossing or runnig parallel to GAIL Gas Pipelines, including 24 hours data logging,data collection from railways,study the effectiveness of existing diode bonding and recommend mitigation measures /modification required at existing doide JB, at all the railway crossings or running parallel as defined in scope of work with specification,design and detail engineering.
210Stary current Interference survey at foreign P/L crossing or runnig parallel with GAIL Gas Pipeline,including 24 hours data logging,data collection from foreign pipeline operator,and recommend mitigation measures at foreign pipeline crossing or runnig parallel to GAIL pipeline as defined in the scope of work,with design,specification and detail enggineering.
211Stray current Interference survey at HT crossings or runnig parallel to GAIL Gas Pipelines,including 24 hours data logging,collection of data from MSEB, calculation of human touch and step voltages,measurent and calculation of AC corrossion current and recommendation for mitigation/effectiveness of existing grounding with modification if required, at HT Line crossings /parallel sections as defined in the scope of work with design,specification and detail enggineering.
212Excavation & Backfilling of pipeline in all type of soils and ordinary rocks for a width of D+500 mm on each side of pipe and exposing the pipeline from top upto 500mm below the bottom of Pipeline including the stacking of excavated earth ,lead upto 50m,stacked earth to be levelled and neatly dressed 'as per the scope of work and directions of EIC.
213Coating repair, Removing the old/ damaged coating/rust greese,moisture and all foreign material at defect material with scrapper,manual surface preparation using hand wire brush ,emery paper,scrappers or a combination of all processes,repairng of the coating with supply of raychem sleeves/cold applied tape/PERP/patch repair kit ,holiday testing after repair,as per the scope of work and to the entire satisfaction of EIC .Multiple patch repairing at one location within one meter span shall be trated as single quantity only.(Compensation if required to land owners shall be in the scope of contractor)
214Repair & Rectification of TR Unit and CPPSM: To carry out breakdown maintenance of cathodic protection equipments like TR units, CPPSM units. EIC will issue instructions for breakdown maintenance to be carried out. Immediately upon receiving such orders, the contractor shall make necessary arrangements and submit schedules thereof in line with the time frame given by the EIC.The scope of work includes tracing out the fault in the system, carrying out necessary repair and rectification, supply of component level spares for repairing the cards and making the unit operational in all respect. The contractor should attend the break down call with in 24 Hrs. Breakdown maintenance will be carried out by the contractor under the guidelines and instructions of the EIC and as per drawing and manual.
215Quarterly Monitoring and Collection of data related to CP System from Manual Test Stations along the pipeline route including compilation and preperation of the reports in the office by a technically qualified person.Quarterly monitoring includes On-Off Potential Survey using current Interrupters twice in a year. Total length of pipeline is approximately 69 Km and rates to be quoted on quarterly basis. Monitoring of MTSs (95 Nos in Dewas CGD) are for eight quarters.
216Monthly Monitoring and Collection of data from TR / CPPSM Units including compilation and preperation of the reports in the office by a technically qualified person. Total numbers of TR/CPPSM unit is 2 (Two). Monitoring of CPPSM/TR units are for 24 (twenty four) months.
217Half-yearly Monitoring and Collection of data related to CP System from Anode Ground bed including compilation and preperation of the reports in the office by a technically qualified person.
218Annual Monitoring and Collection of data related to CP System from Reference electrodes including compilation and preperation of the reports in the office by a technically qualified person.
219Mandatory spares of Kriston System TR Unit : Control Card KS-103A.
220Mandatory spares of Kriston System TR Unit : Spare Control Card KS-104C1.
221Mandatory spares of Kriston System TR Unit : Control Card KS-105D1.
222Mandatory spares of Kriston System TR Unit : Control Card KS-106.
223Mandatory spares of Kriston System TR Unit : Control Card KS-118C.
224Lightning Arrestors for Kriston System TR/CPPSM Unit.
225Transeducers for KRISTON MAKE TR/CPPSM Units (PSP, O/P Voltage,O/P Current,I/P Voltage,I/P Current)
226Panel Meters for KRISTON MAKE TR/CPPSM Units.
227Supply and Installation of Kristron Make Solid State Polarisation Cell for AC De-coupling & AC Interference Suppression for Pipelines
228Design of Anode Ground Bed including Soil Resistivity Survey for specified locations
229CAT survey of Un-Piggable Pipelines at every 10M Interval with Field data analysis at every 500-meter interval by plotting Pipeline Map current v/s Distance on graph sheets / Field computer for immediate on-site review including recording of elevation profile of entire pipeline at 10M as well as depth survey recording at every 10M. Submission of draft report along with data to GAIL GAS for each pipeline section, Dig Verification & Completion of Validation surveys, Completion of all survey work, submission of final reports and printed reports for all sections.
230IJ SUPPLY JOINT,INSULATING, DESIGN PRESSURE- 49 Kg/cm2(g), DESIGN TEMP- 0°C to 65°C, BUTT-WELD AT BOTH ENDS, DESIGN CODE- ASME SECTION-VIII DIV-I, CORROSION ALLOWANCE-1.5 MM, HYDROSTATIC TEST PRESSURE- 76 Kg/cm2(g), CHARPY TEST(BODY, WELDING ENDS)- As per ASTM A 370, HARDNESS TEST REQUIRED AS PER SPEC.BIDDER HAS TO QUOTE & SUPPLY INSULATING JOINT, TEST CERTIFICATE OF THE PRODUCT TO BE PROVIDED WITH THE MATERIAL.GAIL GAS MAY WITNESS TEST & DO PRE DISPATCH INSPECTION OF MATERIAL.
2314 IN, BODY-ASTM A-694, F-52, PUPS- API 5L GR. X-52, 6.4 mm THK.(MIN.)
2328 IN, BODY-ASTM A-694, F-52, PUPS- API 5L GR. X-52, 6.4 mm THK.(MIN.)
233Supply, Installation & Commissioning of Earth Pits as per scope of work & enclosed drawing (Drawings No.- MEC/SD/05/E9/02/02 ) and specifications including supply and installation of copper plate, GI Pipe, salt, charcoal, sand and brick masonry work, excavation and backfilling in all type of soils and MS cover at the top. (Earthing Cable/ strip extra).
234Supply & Laying/ Erection of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) including all associated civil work/ restoration and labour for Grid Fabrication of Existing Earth Pits as per IS 3043.
235Testing of Insulation Joints by using Radio Frequency IJ Tester1.Contractor shall carryout testing of Insulation Joints to find shorting of Insulation Joints to find out shorting of Insulation Joints by using Radio Frequency IJ Tester.2.RF IJ Tester for carrying out IJ testing is in the scope of the Contractor. 3.Contractor shall provide Test Certificate of RF IJ tester before carrying out testing job. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56213749
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 20-07-2026
Authority
Authority Name Gas Authority Of India Limited
Work Description Tender for Annual Rate Contract (Arc) For Maintenance Of Cathodic Protection (Cp) And Associate System For Sonipat, Meerut And Dewas For 2 Years
Basic Detail
Tender No GAIL GAS/NOIDA/RU/8716/26-27/24
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 29 Jun 2026
Submission Date 20 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 3.82 Lakhs
Exemption Available
Document List
3a867fa6-0c9f-4159-817b-a14f6b79ae39.html
BOQ_329391.xls
Tendernotice_1.pdf
vol_I.pdf
vol_II.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

3a867fa6-0c9f-4159-817b-a14f6b79ae39.html

xls

BOQ_329391.xls

pdf

Tendernotice_1.pdf

pdf

vol_I.pdf

pdf

vol_II.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders