Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 21 days TDR #56213723

Tender For Composite Works Cng Stations At Raisen-Shajapur-Sehore, Ttz, Mirzapur-Chandauli-Sonbhadra & Meerut Gas - Electrical, Mechanical, Structural & Civil Works

Issued by Boards / Undertakings / PSU · Ghaziabad, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Jul 2026
21 days left
EMD
20 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Composite Works Cng Stations At Raisen-Shajapur-Sehore, Ttz, Mirzapur-Chandauli-Sonbhadra & Meerut Gas - Electrical, Mechanical, Structural & Civil Works

BOQ

Name of Work:- COMPOSITE WORKS CNG STATIONS AT RAISEN-SHAJAPUR-SEHORE, TTZ, MIRZAPUR-CHANDAULI-SONBHADRA & MEERUT GAs - ELECTRICAL, MECHANICAL, STRUCTURAL & CIVIL WORKS
Sl. No. Item Description
1Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Gail Gas Ltd. Noida Name of Work: COMPOSITE WORKS CNG STATIONS AT RAISEN-SHAJAPUR-SEHORE, TTZ, MIRZAPUR-CHANDAULI-SONBHADRA & MEERUT GAs - ELECTRICAL, MECHANICAL, STRUCTURAL & CIVIL WORKS Tender No: 2026_GAILG_281478_1 Do you want to quote for this Mirzapur-Chandauli-Sonbhadra -Group A? Yes Name of the Bidder/ Bidding Firm / Company : nQuoted PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description SOR Item no. Quantity UOM Unit Rates (Rs) inclusive of GST @ 18% Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder inRs GST In Percentage(%) GST Amount Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Total Amount Witout Taxes TOTAL AMOUNT (Rs.) inclusive of GST @ 18% TOTAL TAXES It will be convert only If you choose Full Conversion, Until it will be treated as INR TOTAL AMOUNT In Words inclusive of GST @ 18%
2MIRZAPUR-CHANDAULI-SONBHADRA
3PART - I : Electrical Works
4Electrical Works Supply
5Supply including packing and forwarding, transportation, delivery at storage to site 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
6Supply including packing and forwarding, transportation, delivery at storage to site 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
7Supply of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make.
8Supply of Switchboards
9Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :
10415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification.
11Single In-comer of 125 Amp (with Single phase preventer) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.
12Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.
13Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel.
14Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C, S/C & E/F RELASE) for UPS and Static Bypass.
15Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
16Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
17415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. & as per standard Specification.
18Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
19Outgoing with 3 nos. 63 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etc ii) Air Compressor iii) APFC Panel
20Outgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.
21Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
22Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
23415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification .
24Single In-comer 63A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
25Outgoing with 2 nos. 32 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)Spare
26Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
27Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
28Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification
29Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
30Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
31Supply including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
32Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent)
33Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent)
34Supply of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.
35Design, engineering, supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
36Earth Pits- GI PIPE Electrode (size 3.0 m long, 65NB Class-B) with 6 mm thick chequered plate cover
37Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
38GI Strip (50X6) mm
39GI Strip (25X3) mm
40Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.
41GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
42Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
43Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
443.5x 120 mm2 A2XFY
453.5x 95 mm2 A2XFY
463.5x 50 mm2 A2XFY
473.5x 35 mm2 A2XFY
484x 25 mm2 A2XFY
494x10 mm2 2XWY
504x 6 mm2 2XWY
514x 2.5 mm2 2XWY
52Supply of following sizes of HDPE Pipe as per approved drawings and directions of Engineer-In-Charge.
5350 mm NB
5480 mm NB
55100 mm NB
56150 mm NB
57Supply of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
58Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent).
59Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent).
60Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
61Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
6220 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
63Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
64Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
65SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
66Design, manufacture, testing at works, supply, storage, transportation to site of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
67Supply of following including necessary clamp, bolts, rawl plugs etc.
68Shock hazard charts
69First Aid Boxes
70Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate.
71Caution boards
72Single Line Diagram in teak wood wall cabinet with glass door
73Wooden key box with glass cover
74Supply of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652 and Indian Electricity Rules.
75Supply of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
76150mm wide
77300mm wide
78Supply of 2 Coats of Primer Painted & Fabricated support structure.
79UPS SYSTEM
80Design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage ,inspection, packing, forwarding, delivery including commissioning spares as required of UPS systems as per specification, block diagram and following rating:
813KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel.
82230 V, 36 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories.
83Erection Material
84Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
85For COCO/RO/OLS/MS/DBS/DCU
86Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
87For COCO/RO/OLS/MS/DBS/DCU
88Supply of required material for construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
89500X500(of inside clearance)X 600(Depth)
90750X750(of inside clearance)X800(Depth)
911000X1000(of inside clearance)X1000(Depth)
92ELECTRICAL WORKS - ERECTION
93Installation, Testing and Commissioning of 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
94Installation, Testing and Commissioning of 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
95Installation, Testing and Commissioning of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make.
96STATUTORY APPROVALS, PERMISSIONS : Coordination & Liasioning with statutory authorities for obtaining Licence/NOC/ Approval /Permission with statutory authorities for GAIL Gas as required for setting of CNG stations .However, all the statutory payment required for such Licence/NOC/ Approval /Permission shall be reimbursed by GGL at actuals against production of documentary evidence and this statutory payment at actuals shall be over and above the coordination and liasioning charges in the items below. The bidder shall note that the rates for the items are inclusive of all expenses (except for statutory payments which shall be reimbursed on actuals) for carrying out the liasioning and coordination work till obtaining the final Licence/NOC/ Approval /Permission.To submit application on behalf of Gail gas to SEB for the incoming power Installation, Testing and Commissioning along with all the required documents, obtaining NOC from SEB for final charging, obtaining drawing approval from CEIG before commencemnt of work and obtaining safety & comissionming approval of Transformer by CEIG and SEB.The price shall be inclusive of Application Fee,liaisioning, Local Transport, Incidental travelling etc, and all other expenses.
97Installation, Testing and Commissioning of Switchboards
98Design, engineering, manufacture, shop testing, Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :
99415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification.
100Single In-comer of 125 Amp(with Single phase preventer ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.
101Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.
102Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel.
103Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C, S/C & E/F RELASE) for UPS and Static Bypass.
104Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
105Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
106415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification .
107Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
108Outgoing with 3 nos. 63 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etc ii) Air Compressor iii) APFC Panel
109Outgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.
110Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
111Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
112415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/23VF/05/E9/E/1081D & as per standard Specification .
113Single In-comer 63A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
114Outgoing with 2 nos. 32 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)Spare
115Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
116Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
117Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification
118Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
119Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
120Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
121Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent)
122Installation, Testing and Commissioning of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent)
123Installation, Testing and Commissioning of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.
124Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
125Earth Pits- GI PIPE Electrode (size 3.0 m long, 65NB Class-B) with 6 mm thick chequered plate cover
126Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
127GI Strip (50X6) mm
128GI Strip (25X3) mm
129Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.
130Installation of GI lightning rod 25 mm dia. 1800 mm long including all labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
131Installation of Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
132Installation, Testing and Commissioning, Laying including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
1333.5x 120 mm2 A2XFY
1343.5x 95 mm2 A2XFY
1353.5x 35 mm2 A2XFY
1363.5x 50 mm2 A2XFY
1374x 25 mm2 A2XFY
1384x10 mm2 2XWY
1394x 6 mm2 2XWY
1404x 2.5 mm2 2XWY
141Installation, Testing and Commissioning of following sizes of HDPE Pipe
14250 mm NB
14380 mm NB
144100 mm NB
145150 mm NB
146Installation, Testing and Commissioning of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
147Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent).
148Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent).
149Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
150Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
15120 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
152Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
153Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
154SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
155Erection,testing and commissioning of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
156Installation, Testing and Commissioning of following including necessary clamp, bolts, rawl plugs etc.
157Shock hazard charts
158First Aid Boxes
159Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate.
160Caution boards
161Single Line Diagram in teak wood wall cabinet with glass door
162Wooden key box with glass cover
163Installation and laying of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652 and Indian Electricity Rules.
164Erection testing and commissioning of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
165150mm wide
166300mm wide
167Painting work of 2 Coats of Primer Painted & Fabricated support structure.
168UPS SYSTEM
169Installation, Testing and Commissioning, packing, forwarding, delivery by equipment supplier at site including commissioning spares as required of UPS systems as per specification, datasheet, block diagram of the following rating :
1703KVA, 50 Hz, Industrial Type,single UPS system suitable for input Power Installation, Testing and Commissioning voltage of 320V-460V- TPN (184-265V/Ph) , output 230 V +/- 1%, AC with Bypass Installation, Testing and Commissioning, Battery Bank , and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 14 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). Charger rating shall not be less than 6.5 kW. All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system).
171230V, 36 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories.
172Erection Material
173Installation,welding and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, Installation, Testing and Commissioning of necessary anchor bolts and grouting etc Installation, Testing and Commissioning of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including Installation, Testing and Commissioning of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
174For COCO/RO/OLS/MS/DBS/DCU
175Installation, Termination and Commissioning of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
176For COCO/RO/OLS/MS/DBS/DCU
177Civil Construction of required material for the construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
178500X500(of inside clearance)X 600(Depth)
179750X750(of inside clearance)X800(Depth)
1801000X1000(of inside clearance)X1000(Depth)
181MECHANICAL & TUBING WORKS
182SS TUBE LAYING & TESTING
183Laying of SS Tubes with PVC tube clamp, Hydro testing at 375 bar and commissioning of SS tubes along with fittings, hose, mass flow meter and valves as given below and as per Technical Specification and scope of work including handling, lifting, transportation from stores to location of CNG stations.
1841”OD X 0.120” min Wall thk. SS Tube
185¾”OD X 0.095” min Wall thk. SS Tube
186½”OD X 0.083” min Wall thk. SS Tube
187Supply of SS Tubes as per Technical Specification
1881”OD X 0.095” min Wall thk.,Material SS316 SS Tube (Refer TS)
189¾”OD X 0.095” min Wall thk.,Material SS316 SS Tube (Refer TS)
190½”OD X 0.083” min Wall thk.,Material SS316 SS Tube (Refer TS)
191Note: Quantities beyond mentioned quantities may be provided as free issue.
192Supply of SS Fittings
193Union
194Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
195Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
196Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
197Reducing Union
198Tube OD 3/4\\" x Tube OD 1/2\\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
199Tube OD 1\\" x Tube OD ¾\\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
200Equal Tee
201Size:1\\" OD x 1\\" OD x 1\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
202Size:3/4\\" OD x 3/4\\" OD x 3/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
203Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
204¾ \\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
205½\\" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
2061\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
207Front Ferrule
2083/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
209½\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
2101\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
211Back Ferrule
2123/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
213½\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
2141\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
215Size : ¾\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
216Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
217Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
218Size : ¾\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
219Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
220Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
221Cross
2223/4\\" OD X 3/4” OD X 3/4\\" OD X 3/4\\" OD Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
223Quick Connect Body & Stem
224End connection:½\\" Tube OD, for stem & ½”NPT (F) for body Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F
225Reducing Union Tee
226¾\\" OD x ½\\" OD x ¾\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
227Male Connector
2281/2\\" NPT male to 3/4\\" OD Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
229Supply of SS Ball Valves conforming to Technical Specification for SS Ball Valves of following sizes, specifications as indicated below :
2302-Way Floating Normal Bore Ball Valve ¾\\"
2313-Way Trunnion Mounted, Reducer Bore Ball Valve ½\\" OD end Connection and ¼” NPT (F) bottom end connection
2322-Way Floating Normal Bore Ball Valve 1/2\\"
233SUPPLY OF HIGH PRESSURE CNG HOSE ASSEMBLY (CONDUCTIVE CORE THERMOPLASTIC HOSE ASSEMBLY)
234Design, Manufacture, testing, Loading , Supply,Transportation & Unloading at GGL stores of 1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away coupling along with Quick connect body & stem (End connection:½\\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\\" NPT(M) and other end of the hose shall be 3/4\\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.
235ERECTION OF MECH. EQUIPMENT
236Handling (including lifting and transportation from Client's store within GA to CNG stations) and erecting in position, the following equipment either on the foundation or on roof at ~ 3 to 4 m above ground level. Contractor's scope includes supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc.. Scope also includes supply of all lifting tools / necessary accessories and hiring of cranes for same.
237Type-I; Cascade 4500/3000 L water capacity. Erection at + 3.0 to 4.0 M level
238Type-I; Cascade 4500/3000 L water capacity, Erection at + Ground level
239Type-IV; Cascade 8800 Water capapcity, Erection at 0.0 level
240Decompression unit-The item also includes supervision of OEM required for installation and commissioning of the equipment at station.
241DISMANTLING, SHIFTING, RE-INSTALLATION & COMMISSIONING OF CNG Decompression unit and Conversion of DBS to Online
242Dismantling,disconnecting cables,earthing, SS tube,pipe, removal of Decompression unit/Daughter Booster Compressor along with related accessories from one Station within GA and shifting/transportation including loading, unloading and then installation, erection, testing and commissioning of same equipment along with accessories, cables at other station within GANote: The above item also includes breaking/dismantling of foundation if required, supply of pipes/cables ,pipe fittings, foundation bolts, supervision of OEM required for installation and commissioning of the equipment at other station.
243Handling including lifting and transportation of dispenser frame from Client's store within city to CNG stations and Erection at + Ground Level
244The quantities given above against individual items are indicative and shall not be considered to be binding. The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge. The unit rate shall be operated to work out the final payment due to Contractor.
245ERECTION OF MECH. EQUIPMENT
246Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC
247Fire fighting Equipments
248Stored Pressure Type DCP -9 Kg confirming to IS 15683 and as per TS
249DCP -75 Kg confirming to IS 10658 and as per TS
250CO2 – 4.5 Kg confirming to IS 15683 and as per TS
251Sand Bucket Stand with 4 Nos. Bucket and as per TS
252Design, manufacture, assembly,testing & supply as well as installation, testing and commissioning of LCV Filling post consisting of the following.-4” Pressure Gauge for pressure monitoring of CNG,-1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away coupling along with Quick connect body & stem (End connection:½\\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\\" NPT(M) and other end of the hose shall be 3/4\\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.-3-Way Trunnion Mounted, Reducer Bore Ball Valve ½\\" OD end Connection and ¼” NPT (F) bottom end connection-2-Way Floating Normal Bore Ball Valve ¾\\"-Necessary SS tubing of sizes 3/4\\"OD and 1/2\\"OD, tube fittings-Vent tube -Required Structural frame and tube supports shall be payable through Structural SOR
253STEEL STRUCTURAL WORKS
254Structure Steel Works for Miscellaneous Structures like Grating , Handrails , Hoardings etc
255Supplying, Fabricating & Erecting in position steel structures fabricated out of MS Girders, channels, Tees, angle, flats, plate, square hollow sections pipes etc. conforming to IS:2062 and/or from pipes conforming to IS:1161 for structural purpose for cascade supporting structure, loading/unloading platform, Gratings for platform, catladder,handrails, hoardings for sinages,Lcv stand, etc. of any size/dia for required design including cutting, welding, bolting, hoisting, fixing in position, including application of one coat of primer at shop and second coat of primer at site after erection and two coats of finishing paint at site .The work is to be completed in all respect as per specification ,scope of work, detailed construction drawings and directions of the Engineer-in-charge.
256[ Rate to include cost of all labour, nut, bolts, tools, tackles, hire charges royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
257Providing and fixing Fencing Gates
258Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge.
2594m Wide x 2.1m High
2602m Wide x 2.1m High
261Providing and Fixing 6 O/P Chequered Plate Covers
262Providing and fixing chequered plate in approved panel or over steel structure including cutting, welding, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved steel primer etc complete as per scope detailed drawings , technical specifications and directions of the Engineer-In-Charge.
263[Rate to include cost of all labour, nut, bolts, stiffening sections, bars tools, tackles, hire charges, royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
264Providing and fixing Fencing Structure
265Supplying, fabricating & fixing steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including applying two coats of approved quality of synthetic enamel paint over a priming coat of in approved shade including supply of all raw materials, bolts, electrodes, transportation, including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per enclosed drawing, technical specifications,scope of works and directions of the Engineer-In-Charge.
266Fencing height 2.1m
267CIVIL WORKS
268Site clerance and earth Work
269Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the Engineer In Charge outside the premises to any place within GA designated by the local authority from site by mechanical transport.Item also include cutting and removing of bushes /tress upto 30cm girth (to be measured at 1.0m above ground) etc. (Approval of location of disposal from local authority is in scope of contractor.)
270All kinds of soil
271Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.)
272All kinds of soil
273Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.)
274Ordinary rock
275Felling of trees of the girth (measured at a height 1 m above ground level ) including cutting of trunks and branches , removing the roots and stacking of serviceable materials and disposal unserviceable material.
276a) beyond 30 cm Girth upto and including 60 cm girth
277b) Beyond 60 cm girth upto and including 120 cm girth
278c) Beyond 120 cm girth upto and including 240 cm girth
279d) Beyond 240 cm girth
280Earthwork in excavation and backfilling in layer of 200mm for foundations of buildings, basements, pipe supports, equipments as well as for manholes, plinth, tunnels, trenches for pipes & sewers & storm water drains, culverts etc., in ordinary and hard soils in both dry and wet conditions including pumping and bailing out surface and subsoil water (dewatering), shoring, strutting, slush removal at all heights and depths as per drawing and specifications wherever required , and backfilling in foundation pits and other places with excavated suitable surplus earth, including reclaiming from other soil heaps kept elsewhere and dressing and levelling,watering and mechanical compaction etc.,transporting surplus unserviceable soil to a place within GA and spreading in layers as per specifications or heaping up to any heights and as per the direction of Engineer Incharge. The Measurement for payment shall be for the theoretical volume only i.e., the volume of the block of the excavation having maximum bottom dimension of the foundation as per drawing.(Approval of location of disposal from local authority is in scope of contractor.)
281(The Contractor shall take into account in his rate the provision for excess excavation for necessary working space, slope etc., required for excavation and other allied works and refilling the side slopes and working space as mentioned in the specification).
282For depth upto & including 1.50 m
283For depth beyond 1.50 m and upto & including 3.00 m
284Extra FOR disposal of surplus earth beyond initial lead of 50m upto 10 KM
285Earth filling from available earth (excluding rock) under floors and other places with special compaction to achieve dry density of 95% standard proctor density including cost of excavation, reclaiming from soil heaps within work premises as per instruction of the EIC at all heights/depths, transporting, depositing, compacting and dressing, trimming complete as desired in layers not exceeding 15 cms including watering, consolidating by mechanical means as per specifications and instructions of the EIC.
286a) With available good quality earth
287Earth work in filling with good quality imported earth from approved source in the layers of 150 mm and compacted up to 95% to its MDD and any plan dimension including all testing, watering, rolling each layer with roller or wooden or steel rammers, and every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing / filling up ground depressions etc. complete in all respect as per scope of work, detailed construction drawings , as per technical specifications and directions of the Engineer-in-charge.
288CEMENT CONCRETE
289Supplying and laying plain cement concrete of the following proportions at all leads and lifts in all levelling courses under foundations, floors, pipelines, trenches, pits etc. using graded stone aggregate 20 mm max. size and down including mechanical mixing, transporting,shuttering (if required) consolidation, finishing, curing etc. complete,as per specifications, drawings and instructions of the Engineer Incharge.
290M-15 1:2:4
291M-10 1:3:6
292STEEL REINFORCEMENT
293Supplying, fabricating and fixing in position TMT steel reinforcements of grade Fe 500 at all levels and positions, all leads and lifts including the cost of transport, straightening, cutting, bending, cranking, binding, fixing, tying in position with annealed binding wire, welding provision of necessary chairs and spacers, including tying and bending dowel bars and their straightening upon deshuttering (wherever necessary) as per drawings and specifications and including cost of binding wire, labour, cover blocks in CM 1:2 etc., all complete for reinforced concrete as per specifications, drawings and instructions of the Engineer Incharge.
294a) Reinforcement conforming to Grade Fe-500 of IS : 1786-2008 ( TMT bars from SAIL /RINL/TATA STEEL/JSW )
2951. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as steel Reinforcement, binding wire and other minor construction materials, testing etc. all bye works and sundry works. 2. Chairs, Laps, Spacers, Wastage etc. shall be to contractor's account.
296Supplying and Laying of design mix,Reinforced Cement Concrete of following Grades at all depths and heights in all types of Foundations, Footings, equipment foundations,columns, pedestal,wall, lintels, ducts, beams, brackets, slabs of all shapes, sills, parapets,bands and any other works both in sub and Superstructures all complete with all bye works as per Drawings, Specification and instruction of Engineer. (The rates shall include the cost of necessary shuttering but excluding the cost of steel reinforcement)
297M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) UPTO PLINTH LEVEL
298M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) ABOVE PLINTH LEVEL
2991. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, other minor construction materials, shuttering , staging, removal of form work, testing of concrete, curing etc. except reinforcement steel with all bye works and sundry works complete. 2. Mix deisgn shall be prepared confirming to relevant IS Codes ( IS 10262, SP.23 & IS 456 Latest Codes) from NABL approved lab and the same shall be approved by EIC.
300Providing, constructing and finishing of compound wall in RCC frame structure with precast RCC wall panels of 100mm thickness mounted on in-situ RCC columns of 400mmx450mm size at an interval of 3.0 m or as specified in construction drawing and height 2m as specified as per scope of work , including plastering, coping, painting, whitewash,concertina coil, embossing of logo of the client, on all columns, finishes all complete as per technical specifications, tender drawing and direction of the Engineer-In-Charge.
3011. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, pre cast wall panels ,ISMC channel section,hard drawn steel wire fabric as per IS 1566 ,RCC M25, concertina coil, RBT , finishes, bitumen, Y angle, other minor construction materials, shuttering, staging, coping, expansion gap filling with \\"Capcell\\" armoured board of \\"Supreme\\" make or equivalent and white sealant material, plastering,painting and all other sundry works.
3022. Foundation/ sub-structure to be paid separately in respective SOR items.
3033.Reinforcement for columns and beam for superstructure shall be paid separately in respective SOR Item.
304Supplying & grouting for Foundations bolt holes/pockets for Equipments, Base plates, Anchoring etc, with cement based non shrink compound such as Shrinkomp of ACC or approved make of FOSROC/SIKA/ROFF including shuttering at all levels and as per drawings, specification and direction of Engineer in charge.
305Providing and laying roof screed with M-15 grade concrete (12 mm down graded coarse aggregate) at all leads and lifts with wooden trowel finish and required slope including mixing of water proofing compound as per manufacturer's specification, curing etc. , as per drawings and direction of Engineer Incharge.
306CC BLOCK work
307Providing and laying cement blocks (solid blocks) masonry mix ratio of 1 :1.5:3 with 200 mm thick blocks upto plinth level and super structure above plinth level up to top level of building in cement mortar 1:3 (1 cement : 3 coarse sand ).
308Upto Plinth level
309Above plinth level
310Brick work with bricks of class designation M 7.5 Grade with Mortar 1:6 (1 Cement: 6 Coarse sand) in all levels.
311Providing and fixing 100mm thick M-25 factory made RCC drain/trench cover including cost of shuttering and minimum reinforement@ 10mm dia TMT Fe-500 bars @100mm c/c bothway in two layers as per direction of Engineer In Charge.The RCC cover shall have edge protection with 100mm wide 1.6mm thick MS sheet all around alongwith 2 nos 12 mm dia bar for hook etc complete including painting of MS sheet.
312Providing and fixing 150mm thick M-25 Pre cast RCC drain/trench cover including cost of shuttering as per drawing and direction of Engineer In Charge. The RCC cover shall have edge protection with 150mm wide 1.6mm thick MS sheet all around alongwith 2 nos 16 mm dia bar for hook etc complete including painting of MS sheet. Reinforcement shall be paid in respective SOR Item.
313Providing and laying R.C.C.(M25 Grade concrete) vacuum dewatering concrete flooring with floor hardener of approved make to be sprinkeled at the rate of 5 kg/sqm before mechanical troweeling as per manufacturer's specifications including mixing, tamping mechanically, consolidating, leveling cement concrete of grade M25 in grade slab, 200/150 thick including suction drying, mechanical trowelling (power float) and finishing, curing, cutting expansion grooves and filling expansion grooves with polysulphide joint fillers complete as specified and directed including shuttering but excluding reinforcement, including doweled construction joints as per drawings.
314FINISHING
31512 mm cement internal plaster on walls of all heights at all levels in perfect line and level
31618 mm external cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:5 (1 cement : 5 fine sand) for all heights and levels in perfect line and level
317Painting with APEX/Wheathershield make exterior paint with one coat of primer and two or more coat of approved paint on new work wherever required to achieve even shade and colour for all heights and levels.
318Providing and laying paving of pre cast concrete interlocking pavers made of M30 grade concrete of 80 mm thickness of approved colour combination, pattern make, size, of compressive strength 300KG /sq cm. Paver blocks should be laid on sand cushion as required with a gap of 1.5mm between the blocks filled with sand including paving and curb gap to be filled with concrete of same grade of concrete pavers
319DISMANTLING/DEMOLISHING
320Demolishing of Cement Concrete (PCC) of all grades manually/mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead.
321Demolishing of RCC of all grades manually/ mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead. Total in Figures 56116030.44000002 56116030.44000002 Five Crore Sixty One Lakh Sixteen Thousand &Thirty and Paise Forty Four Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words Zero Only Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Gail Gas Ltd. Noida Name of Work: COMPOSITE WORKS CNG STATIONS AT RAISEN-SHAJAPUR-SEHORE, TTZ, MIRZAPUR-CHANDAULI-SONBHADRA & MEERUT GAs - ELECTRICAL, MECHANICAL, STRUCTURAL & CIVIL WORKS Tender No: 2026_GAILG_281478_1 Do you want to quote for this Raisen-Shajapur-Sehore -Group B? Yes Name of the Bidder/ Bidding Firm / Company : nQuoted PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description SOR Item no. Quantity UOM Unit Rates (Rs) inclusive of GST @ 18% Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder inRs GST In Percentage(%) GST Amount Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Total Amount Witout Taxes TOTAL AMOUNT (Rs.) inclusive of GST @ 18% TOTAL TAXES It will be convert only If you choose Full Conversion, Until it will be treated as INR TOTAL AMOUNT In Words inclusive of GST @ 18%
322Raisen-Shajapur-Sehore
323PART - I : Electrical Works
324Electrical Works Supply
325Supply including packing and forwarding, transportation, delivery at storage to site 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
326Supply including packing and forwarding, transportation, delivery at storage to site 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
327Supply of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make.
328Supply of Switchboards
329Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :
330415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification.
331Single In-comer of 125 Amp (with Single phase preventer) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.
332Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.
333Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel.
334Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C, S/C & E/F RELASE) for UPS and Static Bypass.
335Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
336Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
337415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. & as per standard Specification.
338Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
339Outgoing with 3 nos. 63 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etc ii) Air Compressor iii) APFC Panel
340Outgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.
341Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
342Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
343415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification .
344Single In-comer 63A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
345Outgoing with 2 nos. 32 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)Spare
346Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
347Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
348Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification
349Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
350Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
351Supply including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
352Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent)
353Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent)
354Supply of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.
355Design, engineering, supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
356Earth Pits- GI PIPE Electrode (size 3.0 m long, 65NB Class-B) with 6 mm thick chequered plate cover
357Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
358GI Strip (50X6) mm
359GI Strip (25X3) mm
360Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.
361GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
362Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
363Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
3643.5x 120 mm2 A2XFY
3653.5x 95 mm2 A2XFY
3663.5x 50 mm2 A2XFY
3673.5x 35 mm2 A2XFY
3684x 25 mm2 A2XFY
3694x10 mm2 2XWY
3704x 6 mm2 2XWY
3714x 2.5 mm2 2XWY
372Supply of following sizes of HDPE Pipe as per approved drawings and directions of Engineer-In-Charge.
37350 mm NB
37480 mm NB
375100 mm NB
376150 mm NB
377Supply of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
378Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent).
379Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent).
380Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
381Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
38220 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
383Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
384Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
385SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
386Design, manufacture, testing at works, supply, storage, transportation to site of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
387Supply of following including necessary clamp, bolts, rawl plugs etc.
388Shock hazard charts
389First Aid Boxes
390Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate.
391Caution boards
392Single Line Diagram in teak wood wall cabinet with glass door
393Wooden key box with glass cover
394Supply of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652 and Indian Electricity Rules.
395Supply of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
396150mm wide
397300mm wide
398Supply of 2 Coats of Primer Painted & Fabricated support structure.
399UPS SYSTEM
400Design, engineering, manufacture, shop testing, supply, packing and forwarding, transportation, delivery at storage ,inspection, packing, forwarding, delivery including commissioning spares as required of UPS systems as per specification, block diagram and following rating:
4013KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel.
402230 V, 36 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories.
403Erection Material
404Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
405For COCO/RO/OLS/MS/DBS/DCU
406Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
407For COCO/RO/OLS/MS/DBS/DCU
408Supply of required material for construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
409500X500(of inside clearance)X 600(Depth)
410750X750(of inside clearance)X800(Depth)
4111000X1000(of inside clearance)X1000(Depth)
412ELECTRICAL WORKS - ERECTION
413Installation, Testing and Commissioning of 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
414Installation, Testing and Commissioning of 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender speciifcation. Transformer shall be as per SEB approved make. (Star rating / Efficiency class of transformer shall be as per SEB standard during executiion).
415Installation, Testing and Commissioning of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make.
416STATUTORY APPROVALS, PERMISSIONS : Coordination & Liasioning with statutory authorities for obtaining Licence/NOC/ Approval /Permission with statutory authorities for GAIL Gas as required for setting of CNG stations .However, all the statutory payment required for such Licence/NOC/ Approval /Permission shall be reimbursed by GGL at actuals against production of documentary evidence and this statutory payment at actuals shall be over and above the coordination and liasioning charges in the items below. The bidder shall note that the rates for the items are inclusive of all expenses (except for statutory payments which shall be reimbursed on actuals) for carrying out the liasioning and coordination work till obtaining the final Licence/NOC/ Approval /Permission.To submit application on behalf of Gail gas to SEB for the incoming power Installation, Testing and Commissioning along with all the required documents, obtaining NOC from SEB for final charging, obtaining drawing approval from CEIG before commencemnt of work and obtaining safety & comissionming approval of Transformer by CEIG and SEB.The price shall be inclusive of Application Fee,liaisioning, Local Transport, Incidental travelling etc, and all other expenses.
417Installation, Testing and Commissioning of Switchboards
418Design, engineering, manufacture, shop testing, Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) :
419415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification.
420Single In-comer of 125 Amp(with Single phase preventer ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.
421Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.
422Outgoing with 01 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for APFC panel.
423Outgoing with 02 nos. 32 Amp TPN MCCB (with TM based O/C, S/C & E/F RELASE) for UPS and Static Bypass.
424Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
425Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
426415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD & as per standard Specification .
427Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
428Outgoing with 3 nos. 63 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etc ii) Air Compressor iii) APFC Panel
429Outgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.
430Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
431Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
432415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/23VF/05/E9/E/1081D & as per standard Specification .
433Single In-comer 63A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.
434Outgoing with 2 nos. 32 Amp 4 pole MCCB (with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)Spare
435Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB with Timer(24Hrs) Auto/Mannual
436Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCB without Timer
437Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification
438Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
439Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 4 Pole, AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals, with RYB indication.
440Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
441Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent)
442Installation, Testing and Commissioning of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent)
443Installation, Testing and Commissioning of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification.
444Installation, Testing and Commissioning including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
445Earth Pits- GI PIPE Electrode (size 3.0 m long, 65NB Class-B) with 6 mm thick chequered plate cover
446Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
447GI Strip (50X6) mm
448GI Strip (25X3) mm
449Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (including bolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc.
450Installation of GI lightning rod 25 mm dia. 1800 mm long including all labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
451Installation of Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
452Installation, Testing and Commissioning, Laying including packing and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
4533.5x 120 mm2 A2XFY
4543.5x 95 mm2 A2XFY
4553.5x 35 mm2 A2XFY
4563.5x 50 mm2 A2XFY
4574x 25 mm2 A2XFY
4584x10 mm2 2XWY
4594x 6 mm2 2XWY
4604x 2.5 mm2 2XWY
461Installation, Testing and Commissioning of following sizes of HDPE Pipe
46250 mm NB
46380 mm NB
464100 mm NB
465150 mm NB
466Installation, Testing and Commissioning of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
467Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent).
468Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent).
469Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
470Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
47120 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
472Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
473Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
474SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
475Erection,testing and commissioning of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
476Installation, Testing and Commissioning of following including necessary clamp, bolts, rawl plugs etc.
477Shock hazard charts
478First Aid Boxes
479Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate.
480Caution boards
481Single Line Diagram in teak wood wall cabinet with glass door
482Wooden key box with glass cover
483Installation and laying of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652 and Indian Electricity Rules.
484Erection testing and commissioning of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
485150mm wide
486300mm wide
487Painting work of 2 Coats of Primer Painted & Fabricated support structure.
488UPS SYSTEM
489Installation, Testing and Commissioning, packing, forwarding, delivery by equipment supplier at site including commissioning spares as required of UPS systems as per specification, datasheet, block diagram of the following rating :
4903KVA, 50 Hz, Industrial Type,single UPS system suitable for input Power Installation, Testing and Commissioning voltage of 320V-460V- TPN (184-265V/Ph) , output 230 V +/- 1%, AC with Bypass Installation, Testing and Commissioning, Battery Bank , and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 14 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). Charger rating shall not be less than 6.5 kW. All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system).
491230V, 36 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories.
492Erection Material
493Installation,welding and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, Installation, Testing and Commissioning of necessary anchor bolts and grouting etc Installation, Testing and Commissioning of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including Installation, Testing and Commissioning of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
494For COCO/RO/OLS/MS/DBS/DCU
495Installation, Termination and Commissioning of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
496For COCO/RO/OLS/MS/DBS/DCU
497Civil Construction of required material for the construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
498500X500(of inside clearance)X 600(Depth)
499750X750(of inside clearance)X800(Depth)
5001000X1000(of inside clearance)X1000(Depth)
501MECHANICAL & TUBING WORKS
502SS TUBE LAYING & TESTING
503Laying of SS Tubes with PVC tube clamp, Hydro testing at 375 bar and commissioning of SS tubes along with fittings, hose, mass flow meter and valves as given below and as per Technical Specification and scope of work including handling, lifting, transportation from stores to location of CNG stations.
5041”OD X 0.120” min Wall thk. SS Tube
505¾”OD X 0.095” min Wall thk. SS Tube
506½”OD X 0.083” min Wall thk. SS Tube
507Supply of SS Tubes as per Technical Specification
5081”OD X 0.095” min Wall thk.,Material SS316 SS Tube (Refer TS)
509¾”OD X 0.095” min Wall thk.,Material SS316 SS Tube (Refer TS)
510½”OD X 0.083” min Wall thk.,Material SS316 SS Tube (Refer TS)
511Note: Quantities beyond mentioned quantities may be provided as free issue.
512Supply of SS Fittings
513Union
514Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
515Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
516Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
517Reducing Union
518Tube OD 3/4\\" x Tube OD 1/2\\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
519Tube OD 1\\" x Tube OD ¾\\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
520Equal Tee
521Size:1\\" OD x 1\\" OD x 1\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
522Size:3/4\\" OD x 3/4\\" OD x 3/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
523Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
524¾ \\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
525½\\" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
5261\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
527Front Ferrule
5283/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
529½\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
5301\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
531Back Ferrule
5323/4\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
533½\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
5341\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
535Size : ¾\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
536Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
537Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
538Size : ¾\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
539Size : 1\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
540Size : ½\\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
541Cross
5423/4\\" OD X 3/4” OD X 3/4\\" OD X 3/4\\" OD Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
543Quick Connect Body & Stem
544End connection:½\\" Tube OD, for stem & ½”NPT (F) for body Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F
545Reducing Union Tee
546¾\\" OD x ½\\" OD x ¾\\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
547Tube End Connection
548½” Tube End & ¾” OD with Ferrule Fitting, SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
549Male Connector
550Size ¼” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
551Size 1/2” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
5521/2\\" NPT male to 3/4\\" OD Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
553Supply of SS Ball Valves conforming to Technical Specification for SS Ball Valves of following sizes, specifications as indicated below :
5542-Way Floating Normal Bore Ball Valve ¾\\"
5553-Way Trunnion Mounted, Reducer Bore Ball Valve ½\\" OD end Connection and ¼” NPT (F) bottom end connection
5562-Way Floating Normal Bore Ball Valve 1/2\\"
557SUPPLY OF HIGH PRESSURE CNG HOSE ASSEMBLY (CONDUCTIVE CORE THERMOPLASTIC HOSE ASSEMBLY)
558Design, Manufacture, testing, Loading , Supply,Transportation & Unloading at GGL stores of 1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away coupling along with Quick connect body & stem (End connection:½\\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\\" NPT(M) and other end of the hose shall be 3/4\\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.
559ERECTION OF MECH. EQUIPMENT
560Handling (including lifting and transportation from Client's store within GA to CNG stations) and erecting in position, the following equipment either on the foundation or on roof at ~ 3 to 4 m above ground level. Contractor's scope includes supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc.. Scope also includes supply of all lifting tools / necessary accessories and hiring of cranes for same.
561Type-I; Cascade 4500/3000 L water capacity. Erection at + 3.0 to 4.0 M level
562Type-I; Cascade 4500/3000 L water capacity, Erection at + Ground level
563Type-IV; Cascade 8800 Water capapcity, Erection at 0.0 level
564Decompression unit-The item also includes supervision of OEM required for installation and commissioning of the equipment at station.
565DISMANTLING, SHIFTING, RE-INSTALLATION & COMMISSIONING OF CNG Decompression unit and Conversion of DBS to Online
566Dismantling,disconnecting cables,earthing, SS tube,pipe, removal of Decompression unit/Daughter Booster Compressor along with related accessories from one Station within GA and shifting/transportation including loading, unloading and then installation, erection, testing and commissioning of same equipment along with accessories, cables at other station within GANote: The above item also includes breaking/dismantling of foundation if required, supply of pipes/cables ,pipe fittings, foundation bolts, supervision of OEM required for installation and commissioning of the equipment at other station.
567Handling including lifting and transportation of dispenser frame from Client's store within city to CNG stations and Erection at + Ground Level
568The quantities given above against individual items are indicative and shall not be considered to be binding. The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge. The unit rate shall be operated to work out the final payment due to Contractor.
569ERECTION OF MECH. EQUIPMENT
570Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC
571Fire fighting Equipments
572Stored Pressure Type DCP -9 Kg confirming to IS 15683 and as per TS
573DCP -75 Kg confirming to IS 10658 and as per TS
574CO2 – 4.5 Kg confirming to IS 15683 and as per TS
575Sand Bucket Stand with 4 Nos. Bucket and as per TS
576Design, manufacture, assembly, testing & supply as well as installation, testing and commissioning of LCV Filling post consisting of the following.-4” Pressure Gauge for pressure monitoring of CNG,-1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away coupling along with Quick connect body & stem (End connection:½\\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\\" NPT(M) and other end of the hose shall be 3/4\\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.-3-Way Trunnion Mounted, Reducer Bore Ball Valve ½\\" OD end Connection and ¼” NPT (F) bottom end connection-2-Way Floating Normal Bore Ball Valve ¾\\"-Necessary SS tubing of sizes 3/4\\"OD and 1/2\\"OD, tube fittings-Vent tube-Required Structural frame and tube supports shall be payable through Structural SOR
577STEEL STRUCTURAL WORKS
578Structure Steel Works for Miscellaneous Structures like Grating , Handrails , Hoardings etc
579Supplying, Fabricating & Erecting in position steel structures fabricated out of MS Girders, channels, Tees, angle, flats, plate, square hollow sections pipes etc. conforming to IS:2062 and/or from pipes conforming to IS:1161 for structural purpose for cascade supporting structure, loading/unloading platform, Gratings for platform, catladder,handrails, hoardings for sinages,Lcv stand, etc. of any size/dia for required design including cutting, welding, bolting, hoisting, fixing in position, including application of one coat of primer at shop and second coat of primer at site after erection and two coats of finishing paint at site .The work is to be completed in all respect as per specification ,scope of work, detailed construction drawings and directions of the Engineer-in-charge.
580[ Rate to include cost of all labour, nut, bolts, tools, tackles, hire charges royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
581Providing and fixing Fencing Gates
582Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge.
5834m Wide x 2.1m High
5842m Wide x 2.1m High
585Providing and Fixing 6 O/P Chequered Plate Covers
586Providing and fixing chequered plate in approved panel or over steel structure including cutting, welding, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved steel primer etc complete as per scope detailed drawings , technical specifications and directions of the Engineer-In-Charge.
587[Rate to include cost of all labour, nut, bolts, stiffening sections, bars tools, tackles, hire charges, royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.]
588Providing and fixing Fencing Structure
589Supplying, fabricating & fixing steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including applying two coats of approved quality of synthetic enamel paint over a priming coat of in approved shade including supply of all raw materials, bolts, electrodes, transportation, including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per enclosed drawing, technical specifications,scope of works and directions of the Engineer-In-Charge.
590Fencing height 2.1m
591CIVIL WORKS
592Site clerance and earth Work
593Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the Engineer In Charge outside the premises to any place within GA designated by the local authority from site by mechanical transport.Item also include cutting and removing of bushes /tress upto 30cm girth (to be measured at 1.0m above ground) etc. (Approval of location of disposal from local authority is in scope of contractor.)
594All kinds of soil
595Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.)
596All kinds of soil
597Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.)
598Ordinary rock
599Felling of trees of the girth (measured at a height 1 m above ground level ) including cutting of trunks and branches , removing the roots and stacking of serviceable materials and disposal unserviceable material.
600a) beyond 30 cm Girth upto and including 60 cm girth
601b) Beyond 60 cm girth upto and including 120 cm girth
602c) Beyond 120 cm girth upto and including 240 cm girth
603d) Beyond 240 cm girth
604Earthwork in excavation and backfilling in layer of 200mm for foundations of buildings, basements, pipe supports, equipments as well as for manholes, plinth, tunnels, trenches for pipes & sewers & storm water drains, culverts etc., in ordinary and hard soils in both dry and wet conditions including pumping and bailing out surface and subsoil water (dewatering), shoring, strutting, slush removal at all heights and depths as per drawing and specifications wherever required , and backfilling in foundation pits and other places with excavated suitable surplus earth, including reclaiming from other soil heaps kept elsewhere and dressing and levelling,watering and mechanical compaction etc.,transporting surplus unserviceable soil to a place within GA and spreading in layers as per specifications or heaping up to any heights and as per the direction of Engineer Incharge. The Measurement for payment shall be for the theoretical volume only i.e., the volume of the block of the excavation having maximum bottom dimension of the foundation as per drawing.(Approval of location of disposal from local authority is in scope of contractor.)
605(The Contractor shall take into account in his rate the provision for excess excavation for necessary working space, slope etc., required for excavation and other allied works and refilling the side slopes and working space as mentioned in the specification).
606For depth upto & including 1.50 m
607For depth beyond 1.50 m and upto & including 3.00 m
608Extra FOR disposal of surplus earth beyond initial lead of 50m upto 10 KM
609Earth filling from available earth (excluding rock) under floors and other places with special compaction to achieve dry density of 95% standard proctor density including cost of excavation, reclaiming from soil heaps within work premises as per instruction of the EIC at all heights/depths, transporting, depositing, compacting and dressing, trimming complete as desired in layers not exceeding 15 cms including watering, consolidating by mechanical means as per specifications and instructions of the EIC.
610a) With available good quality earth
611Earth work in filling with good quality imported earth from approved source in the layers of 150 mm and compacted up to 95% to its MDD and any plan dimension including all testing, watering, rolling each layer with roller or wooden or steel rammers, and every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing / filling up ground depressions etc. complete in all respect as per scope of work, detailed construction drawings , as per technical specifications and directions of the Engineer-in-charge.
612CEMENT CONCRETE
613Supplying and laying plain cement concrete of the following proportions at all leads and lifts in all levelling courses under foundations, floors, pipelines, trenches, pits etc. using graded stone aggregate 20 mm max. size and down including mechanical mixing, transporting,shuttering (if required) consolidation, finishing, curing etc. complete,as per specifications, drawings and instructions of the Engineer Incharge.
614M-15 1:2:4
615M-10 1:3:6
616STEEL REINFORCEMENT
617Supplying, fabricating and fixing in position TMT steel reinforcements of grade Fe 500 at all levels and positions, all leads and lifts including the cost of transport, straightening, cutting, bending, cranking, binding, fixing, tying in position with annealed binding wire, welding provision of necessary chairs and spacers, including tying and bending dowel bars and their straightening upon deshuttering (wherever necessary) as per drawings and specifications and including cost of binding wire, labour, cover blocks in CM 1:2 etc., all complete for reinforced concrete as per specifications, drawings and instructions of the Engineer Incharge.
618a) Reinforcement conforming to Grade Fe-500 of IS : 1786-2008 ( TMT bars from SAIL /RINL/TATA STEEL/JSW )
6191. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as steel Reinforcement, binding wire and other minor construction materials, testing etc. all bye works and sundry works. 2. Chairs, Laps, Spacers, Wastage etc. shall be to contractor's account.
620Supplying and Laying of design mix,Reinforced Cement Concrete of following Grades at all depths and heights in all types of Foundations, Footings, equipment foundations,columns, pedestal,wall, lintels, ducts, beams, brackets, slabs of all shapes, sills, parapets,bands and any other works both in sub and Superstructures all complete with all bye works as per Drawings, Specification and instruction of Engineer. (The rates shall include the cost of necessary shuttering but excluding the cost of steel reinforcement)
621M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) UPTO PLINTH LEVEL
622M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) ABOVE PLINTH LEVEL
6231. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, other minor construction materials, shuttering , staging, removal of form work, testing of concrete, curing etc. except reinforcement steel with all bye works and sundry works complete. 2. Mix deisgn shall be prepared confirming to relevant IS Codes ( IS 10262, SP.23 & IS 456 Latest Codes) from NABL approved lab and the same shall be approved by EIC.
624Providing, constructing and finishing of compound wall in RCC frame structure with precast RCC wall panels of 100mm thickness mounted on in-situ RCC columns of 400mmx450mm size at an interval of 3.0 m or as specified in construction drawing and height 2m as specified as per scope of work , including plastering, coping, painting, whitewash,concertina coil, embossing of logo of the client, on all columns, finishes all complete as per technical specifications, tender drawing and direction of the Engineer-In-Charge.
6251. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, pre cast wall panels ,ISMC channel section,hard drawn steel wire fabric as per IS 1566 ,RCC M25, concertina coil, RBT , finishes, bitumen, Y angle, other minor construction materials, shuttering, staging, coping, expansion gap filling with \\"Capcell\\" armoured board of \\"Supreme\\" make or equivalent and white sealant material, plastering,painting and all other sundry works.
6262. Foundation/ sub-structure to be paid separately in respective SOR items.
6273.Reinforcement for columns and beam for superstructure shall be paid separately in respective SOR Item.
628Supplying & grouting for Foundations bolt holes/pockets for Equipments, Base plates, Anchoring etc, with cement based non shrink compound such as Shrinkomp of ACC or approved make of FOSROC/SIKA/ROFF including shuttering at all levels and as per drawings, specification and direction of Engineer in charge.
629Providing and laying roof screed with M-15 grade concrete (12 mm down graded coarse aggregate) at all leads and lifts with wooden trowel finish and required slope including mixing of water proofing compound as per manufacturer's specification, curing etc. , as per drawings and direction of Engineer Incharge.
630CC BLOCK work
631Providing and laying cement blocks (solid blocks) masonry mix ratio of 1 :1.5:3 with 200 mm thick blocks upto plinth level and super structure above plinth level up to top level of building in cement mortar 1:3 (1 cement : 3 coarse sand ).
632Upto Plinth level
633Above plinth level
634Brick work with bricks of class designation M 7.5 Grade with Mortar 1:6 (1 Cement: 6 Coarse sand) in all levels.
635Providing and fixing 100mm thick M-25 factory made RCC drain/trench cover including cost of shuttering and minimum reinforement@ 10mm dia TMT Fe-500 bars @100mm c/c bothway in two layers as per direction of Engineer In Charge.The RCC cover shall have edge protection with 100mm wide 1.6mm thick MS sheet all around alongwith 2 nos 12 mm dia bar for hook etc complete including painting of MS sheet.
636Providing and fixing 150mm thick M-25 Pre cast RCC drain/trench cover including cost of shuttering as per drawing and direction of Engineer In Charge. The RCC cover shall have edge protection with 150mm wide 1.6mm thick MS sheet all around alongwith 2 nos 16 mm dia bar for hook etc complete including painting of MS sheet. Reinforcement shall be paid in respective SOR Item.
637Providing and laying R.C.C.(M25 Grade concrete) vacuum dewatering concrete flooring with floor hardener of approved make to be sprinkeled at the rate of 5 kg/sqm before mechanical troweeling as per manufacturer's specifications including mixing, tamping mechanically, consolidating, leveling cement concrete of grade M25 in grade slab, 200/150 thick including suction drying, mechanical trowelling (power float) and finishing, curing, cutting expansion grooves and filling expansion grooves with polysulphide joint fillers complete as specified and directed including shuttering but excluding reinforcement, including doweled construction joints as per drawings.
638FINISHING
63912 mm cement internal plaster on walls of all heights at all levels in perfect line and level
64018 mm external cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:5 (1 cement : 5 fine sand) for all heights and levels in perfect line and level
641Painting with APEX/Wheathershield make exterior paint with one coat of primer and two or more coat of approved paint on new work wherever required to achieve even shade and colour for all heights and levels.
642Providing and laying paving of pre cast concrete interlocking pavers made of M30 grade concrete of 80 mm thickness of approved colour combination, pattern make, size, of compressive strength 300KG /sq cm. Paver blocks should be laid on sand cushion as required with a gap of 1.5mm between the blocks filled with sand including paving and curb gap to be filled with concrete of same grade of concrete pavers
643DISMANTLING/DEMOLISHING
644Demolishing of Cement Concrete (PCC) of all grades manually/mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead.
645Demolishing of RCC of all grades manually/ mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor's responsibility irrespective of any Lead. Total in Figures 78228951.96 78228951.96 Seven Crore Eighty Two Lakh Twenty Eight Thousand Nine Hundred & Fifty One and Paise Ninety Six Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56213723
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 22-07-2026
Authority
Authority Name Gas Authority Of India Limited
Work Description Tender for Composite Works Cng Stations At Raisen-Shajapur-Sehore, Ttz, Mirzapur-Chandauli-Sonbhadra & Meerut Gas - Electrical, Mechanical, Structural & Civil Works
Basic Detail
Tender No GAIL GAS/NOIDA/AK/0261/26-27/46
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 29 Jun 2026
Submission Date 22 Jul 2026
Open Date 23 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 20 Lakhs
Exemption Available
Document List
1880c53a-d24d-4933-8013-ef7010bca523.html
BOQ_329418.xls
Tendernotice_1.pdf
Tender_I_II_Compositework.pdf
TSPART_I.pdf
TSPART_II.pdf
TSPart_III.pdf
TSPart_IV.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Jul 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

1880c53a-d24d-4933-8013-ef7010bca523.html

xls

BOQ_329418.xls

pdf

Tendernotice_1.pdf

pdf

Tender_I_II_Compositework.pdf

pdf

TSPART_I.pdf

pdf

TSPART_II.pdf

pdf

TSPart_III.pdf

pdf

TSPart_IV.pdf

TenderDetail
Loading tenders