Tender For Supply Installation Testing and Commissioning of 02 Nos. 1020Kg Bed Cum 15 Passenger Lift And 01 Nos. 08 Passenger Lift At Hybrid Ccu In Birpara Sgh, Alipurduar. -----Internal electrical installation Works For 3Nos. Lift.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Jul 2026
6 days left
EMD
7096
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of 02 Nos. 1020Kg Bed Cum 15 Passenger Lift And 01 Nos. 08 Passenger Lift At Hybrid Ccu In Birpara Sgh, Alipurduar. -----Internal electrical installation Works For 3Nos. Lift.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing 415V, 63 A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make : L&T/ Havells/Standard] [PWD/GS Page: D-3, Item: 4(a)] |
| 2 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [From TPN SFU/Panel to VTPN DB ] (NS) [Make: Gloster/ Polycab/ KEI/ RR/ Havells] 4 core 25 sqmm |
| 3 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. [PWD/GS Page: F-1 Item: 2/b ] |
| 4 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below (a)4 Core x 25 sq.mm . [PWD/GS Page: F-4 Item: 7/c ] |
| 5 | Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. (a) 4 Core x 25 sq.mm [PWD/GS Page: F-5 Item: 8/b ] |
| 6 | Supply and fixing 415V. 4 way, Double Door MCCB incomer VTPN DB with IP 42/43 protection, having 63 A Four pole MCB Isolator as incomer, 2 nos 63 A/40 A TP MCB (10 KA) & 6 nos 6A-32A SP MCB (10 KA) as outgoings, concealed/surface in wall after cutting the wall and mending good the damages to original finish including interconnection and terminations with suitable size of copper wire, duly socketed by solderless Copper Socket and neutral link and provision for earthing attachment, as per direction of E.I.C.(Make -Legrand/ABB/L&T /Seimens) [PWD/GS Page: D-11 Item: 15, Page: D-5 Item: 6, Page: D-6 Item: 7] |
| 7 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 8 mtr [PWD/GS Page: E - 24 Item: 1 ] (For Lift Passage) |
| 8 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt) [Make: Crompton/ Philips / Havells/ Wipro] Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification |
| 9 | Fixing only above single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [[PWD/GS Page: C-2 Item: 17 ] |
| 10 | Supplying and fixing 2 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for four pole MCB, incl. 10 A DP MCB Isolator, concealed/surface in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. [PWD/GS Page: D-9 Item: 11, D-9 Item: 13 ] |
| 11 | Supplying and fixing 4 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for four pole MCB, incl. 32 A FP MCB Isolator, concealed/surface in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. [PWD/GS Page: D-9 Item: 11, D-9 Item: 13 ] |
| 12 | Supply & Fixing 240 V, 10W-12 W, 100 lm/W LED bulk head light fitting and complete with all accessories incl. mending the damages as directed by EIC [Make-Havells/ Wipro/Crompton/Bajaj] [Supply of light - Non-Schedule Item, Fixing of Light - PWD/GS Page: C-2 Item: 13 ] [For Lift] |
| 13 | Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [PWD/GS Page: E-5 Item: 14/a] (For Bulk Head Point at Lift well) |
| 14 | S/F 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required, as per GS. [PWD/GS Page: E-6 Item: 21] |
| 15 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25mm or suitable size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required [PWD/GS Page: E-14 Item: E/1/a] 2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC (For energisation to Bul Head) & ( From VTPN (Located at Ground Floor)To DP Enclosure ((Located at Top Floor) |
| 16 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC (For Power Plug) |
| 17 | 4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC [From VTPN (Located at Ground Floor)To FP Enclosure ((Located at Top Floor) |
| 18 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes [PWD/GS Page: F-5 Item: 9] 2x22/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 19 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 20 | 4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC |
| 21 | Supply & delivery of 230 V, 50 Hz, single phase, 48 watts, 12\\" (300 mm) Sweep, speed 900 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 1145 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Make: EPC/ Orient/ Crompton / Havells] |
| 22 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter.: 30 cm (12\\") [PWD/GS Page: C-4 Item: 28/b ] |
| 23 | Supply & Fixing 300mm cowl with net only on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [PWD/GS Page: D-14 Item: 33 ] [For MRL Lift shaft ] |
| 24 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [PWD/GS Page: D-14 Item: 29 ] |
| 25 | Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 26 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [PWD/GS Page: C-3 Item: 21/a ] |
| 27 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [PWD/GS Page: E-18 Item: 10] |
| 28 | Earthing Installation – with Pipe Electrode :Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [PWD/GS Page: G-1 Item: 1] |
| 29 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm diax 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below :By TATA-Medium GI pipe [PWD/GS Page: G-1 Item: 2/a] |
| 30 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe. [PWD/GS Page: G-2 Item: 3/a] |
| 31 | Earth BusbarSupplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [PWD/GS Page: G-2 Item: 4/c] |
| 32 | Earth Continuity StripConnecting the equipments to earth busbar including S & F 20 mm x 3 mm Galvanised (Hot Dip) MS Flat on wall / floor with GI saddles as required and connection to equipments with incl. drilling holes, bolts, nuts, washers etc. [PWD/GS Page: G-3 Item: 5/c] |
| 33 | Note:- Labour welfare Cess @ 1% and GST @ 18% on Bill amount will be deduct. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 days