Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56213265

Tender For Renovation Of Electrical Works With Replacing Damaged Old Electrical Wiring Line Along With Supply Of Air Conditions (Ac) For Upgradation Of Lab For Nabl Accreditation Purpose At State Seed Testing Laboratory Malda - electrical installatio

Issued by Government Departments · Maldah, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Jul 2026
6 days left
EMD
19900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Maldah → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Electrical Works With Replacing Damaged Old Electrical Wiring Line Along With Supply Of Air Conditions (Ac) For Upgradation Of Lab For Nabl Accreditation Purpose At State Seed Testing Laboratory Malda - electrical installation Work & Installation Of Ac Machines. (Job No. 02 / M / Ow Of 2026 - 27.

BOQ

Name of Work:- Renovation of Electrical works with Replacing Damaged Old Electrical Wiring Line Along with Supply of Air Conditions (Ac) for upgradation of lab for NABL accreditation purpose at State Seed Testing Laboratory Malda - E.I. work & Installation of AC machines. (Job No. 02 / M / OW of 2026 - 27.
Sl. No. Item Description
1PART - A : Renovation, modification of electrical installations incl. wiring within the premises of the seed testing office building at Malda. - E.I. work.
2Sub Head - 1 : Distribution Wiring
3Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish.
48 Mtr.
5Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish
6On Board
7Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
82 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
92 x 22/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC for Power P & S
102 x 22/0.3 (6 sqmm) + 1 x 22/0.3 (4 sqmm) ECC for AC
113 way Ceiling Rose/Batten Holder
12Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required
13Sub Head - 2 : Plugs & Socket
14Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
15Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
16Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type mswitch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
17Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board as per GS.
18Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall as per GS.
19Sub Head - 3 : BDB, PDB, VTPN
20Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS( Make - Legrand )
216 Way ( Up to 160A )
22Supplying and fixing 415 V Four Pole MCCB ofBreaking capacity 25kA/35kA with fixed thermaland fixed magnetic / adjustable thermal and fixedmagnetic setting in existing DBs / enclosure andnecessary connection-- 125 A (Make- Legrand)
23Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 6 Way
24Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
252+10 Way[ Legrand ]
26Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ]
276-32 A SPMCB
2840/63A TPMCB
2940A DPMCB
3063A FPMCB
31Sub Head - 4 : Polythene pipe & wires
32Cutting Channel of size (31 mm x 31 mm)/(40 mm x 40 mm)/(43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13/19/25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG as per GS.
3319 mm dia 3 mm thick
34Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.
352x(10 sqmm)+1x (6 sqmm) (from PDB to SPN)
364x(10 sqmm)+2x (6 sqmm) (from VTPN to HTPN DB)
374x(16 sqmm)+2x (10 sqmm) (from BB to VTPN DB)
38Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works as per GS.
39100 mm x 100 mm x 65 mm
40175 mm x 100 mm x 65 mm
41Sub Head - 5 : Supply & laying of cables
42Supply of 2 / 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / Havells / Fort Gloster]
432 core 6 sqmm
44Laying of cable after cutting floor/pavement/wall as per G.S. for the following sizes.
452 core 6 sqmm
46Laying of one No. cable in underground trench 460mm wide x 760mm average depth as per G.S.
472 core 6 sqmm
48Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
492 core 6 sqmm
50Sub Head - 6 : Supply of Light fittings
51Supply of 4ft LED T-8 box type single batten with end cap complete with all accessories
52Phillips make Cat no. - TMC 502 P 1x T-LED 18W T8 l -2100lm [NS]
53Phillips make Cat no. - TMC 502 P 2x T-LED 18W T8 l -2100lm [NS]
54S/F 9W LED lamp to the lamp point. [PHILIPS make][NS]
55Sub Head - 7 : Fixing of Light fittings
56Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, as per GS.
57Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required
58Sub Head - 8 : Supply of Fans
59Supply of ceiling fans complete with all accessories having the following Model / Cat No. (High speed, Make -Crompton Greaves/ USHA/Orient )
601200 mm(48\\") Sweep ( High Speed).
61Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC )
629\\" ( 230mm ) Speed 1370 RPM.
63Sub Head - 9 : Fixing of Fans
64Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per G.S.
65Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
66Fixing only exhaust fan(9'\\") after making hole in wall as per G.S.
67Supply & Fixing GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
6823 cm Exhaust fan (9\\")
69Sub Head - 10 : Compound Light
70Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
71Wiring with 3X 1.5 Sqmm PVC copper wire in 13mm dia polythene pipe from loop box to HPSV fitting. (average run 4mt) [N/S]
72Supply and fixing of 240V, 120 Watt LED street light luminaire with pressure die cast aluminium housing having efficacy ≥ 110 Lm/W with IP 66 protection ( Make- Make- Crompton Greaves, Cat Ref. CRP-411-120-57-HL2-GL-NSG or equivalent Model of Philips/MAGIK,Surya) complete with all accessories.
73Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
74Supply and fixing Single phase starter 20 Amp (L&T make, MF-1, Cat no.-SS97227OOBO ) on iron leg on wall.
75Sub Head - 11 : Earthing
76Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
77Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size 4 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
78Earthing with 50 mm dia GI pipe( ISI-M) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
79PART - B : Renovation, modification of electrical installations incl. wiring within the premises of the seed testing office building at Malda - SITC of AC Machine.
80Supply & Delivery of Split type A.C Machine nominal cooling capacity of 2/2.2 Ton suitable for operation of 1 Ph, 230V, 50 Hz A.C power supply with energy efficient compressor (Minimum 3 Star rating) incl. loading & unloading charges with carrying at work site. [ Make: O-General, Make- ASGA24BMAA-B (R32) / Mitsubishi electric]
81Installation of 2 Ton capacity split type Air Conditioning machine after making hole in wall as required and condensing unit to be installed after making grounding Nuts, Bolts with iron flat foundation and cementing work as required as per direction of EIC and mending good the damages to original finish and making necy connection as required.
82Supply, Fabrication and Installation of necy. copper refrigeration pipe line (5/8 inch & 1/4 inch) with airtight insulation, aero tape etc. (Approved Make) indoor unit to outdoor unit.
83Supply & Laying of 4 core 2.5 sqmm 1.1 KV insulation grade sheathed Cu cable (Make:- Havells / Polycab / RR Kabel / KEI) with refrigeration pipe line as per direction of EIC for making interconnection / communication between Indoor to Outdoor unit of Split type A.C Machine.
84Supply & laying PVC Drain Pipe 25mm dia(Make:Suprime/Oriplast)
85TERMS & CONDITIONS
86(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST.(ii) The Agency must procure the materials for the Manufacturer / OEM or from their authorized sales channel, so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.iii) Documents that authenticate such procurement from the manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill.iv) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56213265
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 13-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Renovation Of Electrical Works With Replacing Damaged Old Electrical Wiring Line Along With Supply Of Air Conditions (Ac) For Upgradation Of Lab For Nabl Accreditation Purpose At State Seed Testing Laboratory Malda - electrical installation Work & Installation Of Ac Machines. (Job No. 02 / M / Ow Of 2026 - 27.
Basic Detail
Tender No WBPWD/EE/MED/e-NIQ-35/2026-27
Bidding Type Tender
Location
City Maldah
State West Bengal
Key Dates
Publish Date 29 Jun 2026
Submission Date 13 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 19900
Exemption Not Available
Document List
10bb1ea7-8ab8-4443-9334-e2eb6f723808.html
BOQ_5085322.xls
Tendernotice_1 (13).pdf
Tendernotice_2 (2).pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

10bb1ea7-8ab8-4443-9334-e2eb6f723808.html

xls

BOQ_5085322.xls

pdf

Tendernotice_1 (13).pdf

pdf

Tendernotice_2 (2).pdf

pdf

Tendernotice_3.pdf

Disclaimer