Tender For Development Of Science Exhibition Park/ Gap Funding For Science Centre, Srinagar Within The C Us Of Science Centre At Lal Mandi Srinagar.
Tender Value
3.66 Crore
Estimated cost
Bid Submission
14 Jul 2026
0 days left
EMD
7.33 Lakhs
Bank guarantee accepted
Document Fee
5500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Development Of Science Exhibition Park/ Gap Funding For Science Centre, Srinagar Within The C Us Of Science Centre At Lal Mandi Srinagar.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Part |
| 2 | Construction of Amphtheatre |
| 3 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil : |
| 4 | P/L stone soling (Hand packed) in trenches incl. ramming, dressing watering etc. incl. all leads, lifts and carriage upto site of work complete. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | PProviding and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases of columns etc. for mass concrete. |
| 9 | P/L, watering & compacting with (8-10 tonne capacity power road roller) GSB with agg. size not exceeding 90mm to specified lines, grades, cross-sections & density, finished work to be measured incl. carriage of materials by mech.Transport from source of supply upto site of work also includes all leads, lifts, loading, unloading & stacking charges complete. |
| 10 | Brick work with common burnt clay (non modular) bricks claas designation 75 in in superstructure above plinth level upto floor five level including curing in 1:6 cement mortar. |
| 11 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) including cost and carraige of material involved complete job. |
| 12 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 13 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 14 | Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete |
| 15 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50 mm thick with 20mm nominal size stone aggregate. |
| 16 | Carriage of material by mechanical Transport including loading, unloading etc. complete. |
| 17 | Stone aggregate for an average lead of 15 Kms from approved source. |
| 18 | Sand for an average lead of 15 Kms from approved source. |
| 19 | Bricks for an average lead of 15km from approved source |
| 20 | Construction of Toilet Block,Sanitary/Plumbing & Guard hut (Part-B) |
| 21 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 22 | Providing and Fixing of PVC Pipe (Type \\"B\\") of approved quality (Prince/ Finolex, Jinadal/Astral Make or equivalent as approved by incharge engineer) in proper gradient in excavated trenches including jointing and refilling the excavated material and refurbishing complete including charges of excavation. |
| 23 | 110 mm Dia (risers) |
| 24 | 150 mm Dia (under ground) |
| 25 | 90 mm Dia |
| 26 | Providing and Fixing PVC fittings (Type ''B'') of approved quality |
| 27 | Collar 110 mm dia |
| 28 | Collar 150 mm dia |
| 29 | Collar 90 mm dia |
| 30 | Plain Bend 110 mm dia |
| 31 | Plain Bend 90 mm dia |
| 32 | Plain Bend 150 mm dia |
| 33 | Door Tee 110 mm dia |
| 34 | Door Bend 110 mm dia |
| 35 | Reducer 110 mm to 90 mm |
| 36 | Floor Trap 110 mm dia |
| 37 | S/P-Trap110 mm dia |
| 38 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 39 | PN-16 pipe , 20mm OD(SDR-7.4) |
| 40 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 41 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 42 | P/F in position PVC water storage tanks triple layer of sandard make sintex/star and manufacture incl cost of all allied fittings like tank nipple etc & placing in position complete (Sintex/ Supreme/ Venus).(750x2 Lit.barrier type tanks). |
| 43 | P/F of acessories of ISI mark brand approved quality. |
| 44 | 20mm dia Union |
| 45 | 25mm dia Union |
| 46 | 32mm dia Union |
| 47 | Reducer 32mm to 25mm |
| 48 | Reducer 25mm to 20mm |
| 49 | Tanky Nippels 25mm dia |
| 50 | Tanky Nippels 20mm dia |
| 51 | 20mm dia Brass Ball Value |
| 52 | 25mm dia Brass Ball Value |
| 53 | 20mm dia gate Valve |
| 54 | 25mm dia gate Valve |
| 55 | 32mm dia gate Valve |
| 56 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 57 | Providing and fixing od CP connections 450mm long for geysers, low level cistern, wash basins etc. of standard quality |
| 58 | P/F of CP nominal bore fixtures/fittings of standard quality. |
| 59 | Pillar cock |
| 60 | Angel Valve |
| 61 | CP concealed stop cock |
| 62 | CP nipples 100mm long |
| 63 | CP nipples 200mm long |
| 64 | CP nipples 300mm long |
| 65 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 literwhite P.V.C automatic flushing cistern. |
| 66 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap |
| 67 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres: |
| 68 | P/L stone soling (Hand packed) in trenches incl. ramming, dressing watering etc. incl. all leads, lifts and carriage upto site of work complete. |
| 69 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) using crushed aggregate |
| 70 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 71 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 72 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 73 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 74 | Foundations, footings, bases of columns etc. for mass concrete. |
| 75 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 76 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 77 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 78 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in :in superstructure including curing in upto floor V level in Cement mortar 1:4 (1 cement :4 coarse sand) including cost and carriage of all materials involved upto site of work complete. |
| 79 | Brick work with common burnt clay (non modular) bricks claas designation 75 in in superstructure above plinth level upto floor five level including curing in 1:6 cement mortar. |
| 80 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) including cost and carraige of material involved complete job. |
| 81 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) including carriage of all materials upto site of work complete. |
| 82 | 52mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 liter per 50kg of cement or as per manufacturer’s specifications, including cost of cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. |
| 83 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 84 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown |
| 85 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately). Imported wood |
| 86 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 3.5 mm to 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.35 mm (First class imported wood). |
| 87 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge (35 mm thk).First class imported wood. |
| 88 | Providing and fixing 35 mm thick ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 89 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 90 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 91 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 92 | 100x10 mm |
| 93 | 300x10 mm |
| 94 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete. |
| 95 | Proving and fixing glass 4mm thickness as per specification with first deodar beading up to size 40x20mm in wooden frames and painting as per specifications. |
| 96 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 97 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 98 | Providing and fixing 250x30mm imported wood eaves boarding planed on one side. including cost of adhesive , nails etc.complete job. |
| 99 | Providing and fixing in position 12 mm thick imported wooden panelling in ceiling / soffits tounged and grooved of approved brand and manufacture including supporting budloo wood frame work including cost of necessary beading where ever required as per the directions of Engineer in-charge at site complete. |
| 100 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 101 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work.(hard and soft wood) |
| 102 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 103 | Providing /fixing 25 mm dia pvc conduit pipes for electric fittings of standard quality . |
| 104 | Wiring for light point/ fan point/ exhaust fan pointpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, angle holder ,blub suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 105 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 106 | Carriage of material by mechanical Transport including loading, unloading etc. complete. |
| 107 | Stone aggregate for an average lead of 15 Kms from approved source. |
| 108 | Sand for an average lead of 15 Kms from approved source. |
| 109 | Bricks for an average lead of 15km from approved source |
| 110 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres: |
| 111 | P/L stone soling (Hand packed) in trenches incl. ramming, dressing watering etc. incl. all leads, lifts and carriage upto site of work complete. |
| 112 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) using crushed aggregate |
| 113 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 114 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 115 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 116 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 117 | Foundations, footings, bases of columns etc. for mass concrete. |
| 118 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 119 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 120 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 121 | Brick work with common burnt clay (non modular) bricks claas designation 75 in in superstructure above plinth level upto floor five level including curing in 1:6 cement mortar. |
| 122 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) including cost and carraige of material involved complete job. |
| 123 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) including carriage of all materials upto site of work complete. |
| 124 | 52mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 liter per 50kg of cement or as per manufacturer’s specifications, including cost of cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. |
| 125 | Providing and laying vitrified floor tiles (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (600x600mm) |
| 126 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately). Imported wood |
| 127 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 3.5 mm to 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.35 mm (First class imported wood). |
| 128 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge (35 mm thk).First class imported wood. |
| 129 | Providing and fixing 35 mm thick ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.21.1 With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 130 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 131 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 132 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 133 | 100x10 mm |
| 134 | 300x10 mm |
| 135 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete. |
| 136 | Proving and fixing glass 4mm thickness as per specification with first deodar beading up to size 40x20mm in wooden frames and painting as per specifications. |
| 137 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 138 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 139 | Providing and fixing 250x30mm imported wood eaves boarding planed on one side. including cost of adhesive , nails etc.complete job. |
| 140 | Providing and fixing in position 12 mm thick imported wooden panelling in ceiling / soffits tounged and grooved of approved brand and manufacture including supporting budloo wood frame work including cost of necessary beading where ever required as per the directions of Engineer in-charge at site complete. |
| 141 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 142 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work.(hard and soft wood) |
| 143 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 144 | Providing /fixing 25 mm dia pvc conduit pipes for electric fittings of standard quality. |
| 145 | Wiring for light point/ fan point/ exhaust fan pointpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, angle holder ,blub suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 146 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 147 | Carriage of material by mechanical Transport including loading, unloading etc. complete. |
| 148 | Stone aggregate for an average lead of 15 Kms from approved source. |
| 149 | Sand for an average lead of 15 Kms from approved source. |
| 150 | Bricks for an average lead of 15km from approved source |
| 151 | Development of Pathways (Part C) |
| 152 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil : |
| 153 | P/L stone soling (Hand packed) in trenches incl. ramming, dressing watering etc. incl. all leads, lifts and carriage upto site of work complete. |
| 154 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) using crushed aggregate |
| 155 | Providing and laying cement concrete in kerbs, steps and the like at or near ground levelincluding curing, excluding the cost of centring, shuttering, and finishing. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) |
| 156 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases of columns etc. for mass concrete. |
| 157 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 158 | Providing and fixing rough walk colour coated cement concrete chequerred tile size 300x300 mm and 30 mm thickness and m 30 grade made by block making machine and design shape used in foot path, courtyard jointe with neat cement slurry mixed with colour pigment to match the required shade of tiles including rubbing, cleaning and curing on 20 mm thick bed of cement mortar mix 1:4 |
| 159 | Carriage of material by mechanical Transport including loading, unloading etc. complete. |
| 160 | Stone aggregate for an average lead of 15 Kms from approved source. |
| 161 | Sand for an average lead of 15 Kms from approved source. |
| 162 | Under Ground water storage Sump (Part-D) |
| 163 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil : |
| 164 | P/L stone soling (Hand packed) in trenches incl. ramming, dressing watering etc. incl. all leads, lifts and carriage upto site of work complete. |
| 165 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) using crushed aggregate |
| 166 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 167 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V level |
| 168 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 169 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 170 | Suspended floors, roofs, landings, balconies and access platforms. |
| 171 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 172 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 173 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) including cost and carraige of material involved complete job. |
| 174 | Carriage of material by mechanical Transport including loading, unloading etc. complete. |
| 175 | Stone aggregate for an average lead of 15 Kms from approved source. |
| 176 | Sand for an average lead of 15 Kms from approved source. |
| 177 | Development of Internal Road (Part-D) |
| 178 | INTERNAL ROAD |
| 179 | Banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in All kinds of soil: |
| 180 | Consolidation of subgrade with power road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the subgrade. |
| 181 | Supply and stacking of graded stone agg. at site of size range 63-45mm Grade IInd with stone screening /chipping 13.20mm size nominal size type A stone dust moorum at site including all carriage and laying water bound macdam with specified stone agg. stone screenings and binding material incl.Screening sorting, spreading to template and consolidation with PRR with 8-10 tonne capacity etc complete. |
| 182 | Providing, laying, spreading of 75mm thick compacted wet mix macadam on prepared sub grade/sub-base with crushed quarry stone agg. of specified grading as per IRC/ MOST/MORTH specifications incl. mixed crushed material with predetermined quantity of water in accordance with specifications to form dense mass laying in uniform layers with paver in sub-base/base coarse on well prepared surface rolled with vibratory roller of 8/10 tonne capacity, speed of which should not exceed 5km/hour for each layer, rolling should continue till 98% density is achieved to approved grade & cross section the mixing is to be prepared in approved mechanical mixing plant of suitable capacity & carriage of mixed material by tipper upto site of work complete incl. cost & carriage of all material upto site of work. |
| 183 | Providing and applying tack coat using hot straight run bitumen of VG-10 grade incl. heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning & preparing the existing road surface to remove all dirt, dust, mud etc. & finally brooming the surface as per required specification incl. cost & carriage of bitumen. On WBM surface @ 0.75 Kg/Sqm |
| 184 | Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specifications and directions of Engineer-in-Charge. 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. |
| 185 | 2.5 cm premix carpet surfacing with 3 cum of stone chippings 10 mm nominal size per 100 sqm and bitumen emulsion (medium setting min. 65% bitumen contents) complying with IS: 8887, using 96 kg per cum of chippings of road surface including consolidation with road roller etc. complete. |
| 186 | Providing and laying 6mm thick compacted seal coat of premixed fine aggregate (passing 2.36mm & retained on 180 micron sieve, with 128kgs of bitumen of VG-10 grade per cum of fine agg. (0.768 kgs of bitumen/sqm) & 0.60 cum of fine agg. per 100 sqm of road surface incl. rolling and finishing complete as per MOST/MORTH specification incl. cost & carriage of all materials involved from source upto site of work complete incl. cost & carriage of bitumen. |
| 187 | MECHANICAL |
| 188 | Fire Fighting System |
| 189 | PIPES & ACCESSORIES |
| 190 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling, undeground (excavation work as well) along with damping insulation with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 191 | 25 mm dia |
| 192 | 50 mm dia |
| 193 | 80 mm dia |
| 194 | 100 mm dia |
| 195 | 150 mm dia |
| 196 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 197 | Single headed stainless steel |
| 198 | Supplying and fixing orifice plate made out of 6 mm thick Stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 199 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 200 | Stainless Steel (Grade 304) |
| 201 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 202 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : |
| 203 | 2way - 100 mm dia M.S. Pipe |
| 204 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 205 | TERRACE TANKFabrication installation,testing and commissioning of water priming tank (Fire Tank) to be fabricated out of M.S sheet of thickness 6mm and of capacity 10000 Ltrs which shall be installed above fire pumps and connected with the suction header of the fire pump. The tank shall be placed over suitable structural steel stand to be fabricated out of ISA 65x65x6mm and ISMC 100 as required. The job further includes finishing with epoxy paint,internal epoxy paint(primer + 2 coats), synthetic enamel paint on steel (external ,primer +2 coats) . The job also includes necessary installation of sockets, isolation valves and suitable locking arrangement and making necessary holes along with nozzels for inlet, outlet , overflow , manhole with cover (welded) and drain pipes with drain valve with fittings and connection with suction line of pump.Dimensions of tank as per site requirements. The job also includes labour, hydro-test, fittings etc necessary for completion of job) |
| 206 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : |
| 207 | Stainless Steel (Grade 304) |
| 208 | Providing and fixing Weather proof hose cabinets for hydrants fabricated from 16 g MS sheet and MS angle with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 nos.15m long hose, 1 No short branch pipe,1 no first aid hose reel,extinguisher,pressure guage and one fireman's axe. The cabinet shall be painted with one coat of primer and finished stove enamelled \\"Fire Red\\", \\"Fire Hose\\" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 mx 0.25 m or as per arch). |
| 209 | Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete. |
| 210 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) |
| 211 | (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure,horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325.(c) M.S.fabricated common base plate, coupling, couplingguard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plasteredand with anti vibration pads. |
| 212 | 900 lpm at 35 m Head (01 working & 01 stand-by) |
| 213 | Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.Refer SLDThe complete panel shall be made out of 2.00mm CRCA sheet including frame/partitions/ doors etc. Gland plates should be 3.0mm thick |
| 214 | INCOMER |
| 215 | 1No.MCCB 63 A TP+NL with fault breaking capacity 35KA with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100% upto 415V. MCCB shall conform to IS-1397-2 1993 as ammended. |
| 216 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 217 | METERING, INDICATOR AND RELAYS: 1. Provide 3Nos resin filled nylon 66 casing CTs, class - 1.0 and MFM True RMS type digital with min. features of measurments, A, V, Hz and RS-485 port for BMS with Class-1.0 accuracy for all outgoing feeder. 2. E-series R,Y,B phase indication lamps with 4no.s SP HRC fuses as per req. for each incomer. 3. Provide 3nos indicating lamps for status indication \\"On\\"\\"Off\\" tripped due to earth fault on each incomer |
| 218 | Bus Bars: 100amps TP+N 50KA, 500V grade busbar chamber of suitable length with Al busbars mount on SMCsupports. All interconnections shall be FRLS PVC insulated copper coded wires, current density of bus bars shall not be less than 1amps/sq. mm for Al and 2amps/sq. mm for Cu cross sectional area of bus bar |
| 219 | OUTGOINGS |
| 220 | Note: all starters shall be High performance star delta / DOL Motor Starters as specified (Type 2 Co-ordenation selection shall be in consideration of that the all pump motor should be minimum IE3 efficiency |
| 221 | 2 set of 40A TP MPCB of 50KA WITH THERMAL over load relay each for 7.5HP DOL Motor starter type ii co-ordination along with TP power contactors (AC3duty) with inbuilt 1NO +1NC contact additional potential free auxilary contactor. CT operated digital ammeter with selection switch, red, green & yellow indicating lamps each with control SP HRC Fuses Start/Stop Push buttons, Auto/Manual/off selector switch, timer, 230Vac, 0-30Second and spp complete as required, FOR 2 NOs terrace Pumps (1w+1s). 1Nos 40A TP MCB Spare |
| 222 | Cable Connection: The job includes providing and installation of necessary cabling with insulation from main panel to pump panel to pumps All pumps shall be able to work automatically or manually. Panel starter shall be based on pumps motor rating. following provisions to be provided in fire panel: audio visual alarm and indications having disconnect / reset facility with a range of 1/2 km. annuciator to be provided in the fire panel with hooter and acknowledge , test and reset PBs. the indication shall come on when electrical driven pump set fails to start on pressure drop or when there is power failure during pressure drop. Facility for mode selection i.e. auto or manual test and local/remote. protection failure and control cabling. remote indication of ON/OFF/Trip shall be provided through potential free contact. |
| 223 | FIRE FIGTING PANEL AS DESCRIBED ABOVE |
| 224 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 225 | 150 mm dia |
| 226 | 100 mm dia |
| 227 | 50 mm dia |
| 228 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 229 | 150 mm dia |
| 230 | 100 mm dia |
| 231 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 232 | 150mm dia |
| 233 | Supply, Installation, testing and commissioning of pressure switches for Fire Pumps, diaphragm type, adjustable range from 0-5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications. |
| 234 | Supply, Installation, Testing and Commissioning of 150 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 . |
| 235 | Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 . |
| 236 | Providing and fixing proprietary polyshield outer mechanical protection on nitrile rubber insulation comprising of Wrapping with polyglass tape helically wound and subsequently applying 2 coats of polyshield material (resin and hardener) as per manufacturers specifications and approved by site incharge. |
| 237 | Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683) .Complete with all accessories |
| 238 | Supplying,Installation,Testing and Commissioning of MAP 90 ABC Type Fire Extinguisher 6 Kg. Capacity fully charged,ISI Mark(IS:15683)suitable for Class A/B/C Type Fires .complete with all accessories |
| 239 | Supplying,Installation,Testing and Commissioning of water Type Fire Extinguisher 9 ltr. Capacity,fully charged , ISI Mark(IS:15683) stored pressure .Complete with all accessories |
| 240 | Central Heating System |
| 241 | VRF Outdoor Unit (HEAT PUMP TYPE) |
| 242 | Supply Installation, Testing & Commissioning of modular imported type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. |
| 243 | VRF unit and compressor shall be of same OEM make. Latest BEE guideline for AC system/ECBC/GRIHA/AHRI whichever guidelines is more stringent shall be followed based on GRIHA star rating requirement of building. The VRF units shall be able to deliver 100% capacities at AHRI conditions till ambient temperature of 39 deg C. For improvement in efficiency other than ISEER value, the VRF units will with minimum COP of 3.5 at 100% load at AHRI conditions. The VRF outdoor unit shall have operating range from 0 deg C to 50 deg C in cooling mode &(-5 Deg C to 15 Deg C) in heating mode and the OEM shall submit catalogue for VRF unit, mentioning the same. The unit shall be complete individual controller and fittings with necessary wiring, connection & termination, painted MS frame for outdoor unit, cowl for ODU etc. |
| 244 | Indoor VRV Units (Nominal Capacity) - Ceiling Mounted Cassette Round Flow/4Way type unit. |
| 245 | Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unitequipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, high lift drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The units must be compatible to the above mentioned outdoor unit with wireless remote control for each indoor unit. The job also includes wireless remotes for each indoor unit. The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 246 | 1.6 TR |
| 247 | 2.0 TR |
| 248 | 2.8 TR |
| 249 | 3.2 TR |
| 250 | 3.6 TR |
| 251 | 4.0 TR |
| 252 | 4.6 TR |
| 253 | Ceiling Mounted High Static Ductable TFA Unit |
| 254 | Supply, installation, testing and commissioning of following minimum capacity ceiling mounted TFA ductable unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, high lift drain pump, bird screen, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 255 | 4.0 TR/ 1600 CFM OR ABOVE TR-Standard VRF Ductable TFA unit with all controls & accessories |
| 256 | 6.4 TR/ 2500 CFM OR ABOVE TR-Standard VRF Ductable TFA unit with all controls & accessories |
| 257 | Refrigerant Pipe Supply, Installation, testing and commissioning including vaccumization and Nitrogen testing of nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness for Suction and Liquid lines, all accessories as per specifications etc. as required. Pressure testing to be done at 1.5 times the working pressure. Thickness of the pipeline must be as per the standards of soft drawn pipes.Piping vaccumiazation, nitrogen flushing during brazing and Nitrogen testing to be done by contractor and price for the same to be included. The job also includes p/f of resting fixtures for indoor unit, piercing of walls for laying of liquid, vapor & condensate pipes and repairing of same to bring it in original decor. |
| 258 | 34.9/41.3 mm dia (OD) (Hard drawn) with 19mm thick insulation |
| 259 | 28.5/31.8 mm dia (OD) (Hard drawn) with 19mm thick insulation |
| 260 | 22.2/25.4mm dia (OD) (Hard drawn) with 19mm thick insulation |
| 261 | 19.1 mm dia (OD) (Hard drawn) with 19mm thick insulation |
| 262 | 15.86 mm dia (OD) (Soft drawn) with 13mm thick insulation |
| 263 | 12.7 mm dia (OD) (Soft drawn) with 13mm thick insulation |
| 264 | 9.5 mm dia (OD) (Soft drawn) with 13mm thick insulation |
| 265 | 6.4mm dia (OD) (Soft drawn) with 13mm thick insulation |
| 266 | Supply, Lifting, shifting, positioning, installation, testing & Commissioning of fittings Y-joints/refnets and headers for all Indoor & Outdoor units. |
| 267 | Supplying, fixing, testing and commissioning of Main centralized controller with advanced technology Push Button Type suitable for groups of indoor units to be installed for control (BMS Compatible). All required accessories (hardware and software) to be provided for BMS connection. Controller shall have software for automation (ON/OFF, scheduling, lock/unlock, temperature setting, error detection) of entire system, all indoor units add monitoring of corresponding outdoor units from one central location. Controller should be BMS compatible. It must show the status of all indoor units along with outdoor unit. All required accessories (hardware and software) to be provided for BMS connection. Controller should capable to provide all detail like Fail safe logic. ON/OFF sequencing.Central controller complete with necessary hardware, accessories etc. shall be provided for controlling all the IDUs& ODUs with 15% spare. |
| 268 | Propeller Fans |
| 269 | Supplying, installation, testing & commissioning of low noise Plastic body circular/rectangular Propeller exhaust fans suitable for following capacities complete with electric motor suitable for operation on 220 V+ 10%, 50 Hz, 1 phase AC supply, 6 Amp plug and wiring between the fan and the socket, fitted with mounting frames, as per specifications of the following capacities. The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 270 | 300mm dia |
| 271 | Supply, Installation and Testing of Site fabricated GSS rectangular ducting complete including fully threaded GI rods ,Hangers & Supports complete with end fixing as approved clients/consultants in accordance with the approved shop drawings and specifications. Quoted price shall be inclusive of necessary lifting & shifting charges towards installation of supply air ducts outside or within building wherever required.The job also includes piercing of holes , cutting of walls and repairing of same to bring it in original decor. |
| 272 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Duct shall be Al foiled mat finished closed cell Elastomeric Nitrile Rubber of Thermal conductivity of the insulation material shall not exceed 0.037 W/m°K at an average temperature of 20 degree C. Density of the nitrile rubber shall be 40-60 Kg/m3. The product shall have temperature range of -40 degree C to 105 degree C. The insulation material shall be fire rated for Class 0 as per BS 476 Part 6: 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapor permeability shall be not less than 0.024 per inch i.e. μ>7000: Water vapor diffusion resistance). |
| 273 | 19 MM thick |
| 274 | DUCT ACOUSTIC: - Supplying and fixing of 15mm thick of Acoustic Insulation Inside the Duct with Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 & shall be fibre free. The material shall have a thermal conductivity not exceeding 0.047 W/m.K @ 20 Deg. C & shall conform to Class 1 rating for surface spread of Flame in accordance to BS 476 Part 7. The insulation shall pass Air Erosion Resistance Test in accordance to ASTM Standard C 1071-05 (section 12.7), from an independent testing agency & should have built-in Ultra-Fresh Anti-Microbial Protection, and should pass Fungi Resistance as per ASTM G21 & Bacterial resistance as per ASTM 2180. To be applied using Adhesive. |
| 275 | Supply and Installation of 2Hr. Fire Resistant Fabric Flexible Connection to be installed between all the IDU and the ducting to provide flexibility of movement in case of a seismic event and to prevent transmission of vibration from the unit to the duct. |
| 276 | Supply, Installation, Testing and commissioning of plenum box made from galvanized sheet steel (min. 22G) and is supplied self-finish. Plenums are manufactured with a 15mm internally formed flange at each end, Plenum box comprises a casing with horizontal circular spigot for duct connection, with spigot mounted perforated trimming damper adjustable through front face complete as required . The job also includes piercing of holes, cutting of walls and repairing of same to bring it in original decor. |
| 277 | Supply, installation, testing of extruded aluminum powder coated linear grill complete.The job also includes necessary civil works such as cutting of ceiling / walls for installation and repairing of same to original décor.100 MM |
| 278 | Supply and installation of volume control /duct dampers for indoor units and for AHUS. |
| 279 | Supply, fixing and commissioning of Fresh/ exhaust air louvers with section comprising of powder coated Aluminum louvers & bird screen as required. The job also includes necessary civil works such as cutting of ceiling/walls , hole making etc for installation and repairing of same to original décor. |
| 280 | Supplying, fixing testing commissioning of supply/return air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring & removable core. The job also includes necessary civil works such as cutting of ceiling/walls , hole making etc for installation and repairing of same to original décor. |
| 281 | Transmission and Control Cable Providing & fixing control cum transmission wiring in medium duty PVC Conduit between indoor and outdoor units. 2C x 1.5 Sqmm Cu Cable |
| 282 | Cable Tray: -Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required |
| 283 | 100 mm. Width x 50mm. Depth x 1.6mm. Thickness. |
| 284 | 150 mm. Width x 50mm. Depth x 1.6mm. Thickness. |
| 285 | 300 mm. Width x 50mm. Depth x 1.6mm. Thickness. |
| 286 | Design, Supplying, installation, testing & commissioning of cubical type floor mounted power distribution panels suitable for 415V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable capacity extensible type FP Aluminum Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 3 MV A for I Sec. with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq.mm. Incomer 1No. 500 Amps,36 kA Four Pole, MCCB with thermal & magnetic releases. With 3 Nos. R, Y, B Indication Lamps with 2A back up SP MCB with ON indication. Busbar: Aluminum bus bars of minimum of 625A capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. Outgoings: Supplying and fixing following outgoing MCCB/MCB including connection, inter connection etc. with suitable size of wires complete as required. 63 Amp 4P MCCB with RCCB (along with SPP) for each ODU and 200 Amp 4P MCCB for each floor of the building to be connected to sub panel in each floor. It also includes fitting of 63 Amp 4P MCCB With RCCB (along with SPP) .The panel is to be provides with OLR, Earth fault relay, phase reversal and phase loss protection. It also includes Providing and fitting of Sub-Panel Boxes (floor wise) with 63 A 4P MCCB 1 No as incomer , suitable rating DP MCB for each indoor unit, TFA unit including digital voltmeter as per the no. of indoor units with indication lamps duly fitted on wall in each floor for indoor units. |
| 287 | CABLE |
| 288 | Supply, laying testing and commissioning of following sizes of XLPE insulated PVC sheathed armoured Copper conductor cable of 1.1 KV grade along with earthing wire including the cost of providing required gap between adjacent cables (minimum one cable dia.) and including the cost of providing identification tags, cable trays, stays, hangers etc. complete as per specification, as required,making end termination with brass compression glands and Al. lugs clamps, ties etc. as required. |
| 289 | 4 Core 25 Sqmm |
| 290 | 4 Core 16 Sqmm |
| 291 | 4 Core 10 Sqmm |
| 292 | 4 Core 6 Sqmm |
| 293 | 3Core 36 Sqmm |
| 294 | 3 Core 1.5 Sqmm |
| 295 | 3 Core 2.5 Sqmm |
| 296 | 3 Core 4 Sqmm |
| 297 | Supplying ,Laying and Testing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe/Cable Tray as required.It also includes making end termination with brass compression glands and Al. lugs. |
| 298 | 3.5C x 240 mm² LT XLPE (A2XFY) aluminum |
| 299 | Earthing P/F of Maintenance free Chemical Earthing using GI Electrode of size 60 mm dia, 03 meter long connected with 4OX5 mm GI internal strip complete with excavation, civil works, cast iron cover with back fill compound along with 50 kg bag of Back fill compound/SOR Compound (highly conductive, non-corrosive moisture retaining chemical) complete. |
| 300 | Supplying and laying 25 mm X 5 mm GI strip as strip to earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required and provision of conduits if necessary. |
| 301 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 302 | Drain Pipe(CPVC) Supply & fixing of heavy duty CPVC/PPR Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness of closed cell nitrile rubber/ EPDM insulation as required & as per specifications. The job also includes piercing of walls and p/f of supports for laying of drain pipes and repairing of same to bring it in original decor. |
| 303 | 25mm dia |
| 304 | 32mm dia |
| 305 | Note: Shop drawings for VRF machine locations and Duct layout, refrigerant and drain Piping layout, Electrical panel design and location, location, cable tray and cabling routes to be provided by contractor/firm. The Drawings need to be approved by third-party to be nominated by the Division. |
| 306 | Electric Part |
| 307 | Supply and errection of 9.0 mt long(410SP-33) steel tubular poles, sawaged type conforming to IS-2713, (Part-II) ,planting depth 1.5 mt .Pole shall have 2 no bolts welded at a distance of 3 mt. from bottom of pole and suitable holes shall be drilled in pole for service connection and lum. earth wires. |
| 308 | Digging of suitable pole pit to errect pole in it having planting depth of 1.5 mts. & Providing of cement concrete block up to G.L. and Concrete jacketing above G.L. in 1:2:4 cement concrete. |
| 309 | Supply installation testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 310 | Supply installation testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 311 | Supply installation testing and commissioning of GI Channel/Angle/Flat of sizes including clamps |
| 312 | Supply installation testing and commissioning of Galvinized Nuts and Bolts. |
| 313 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 314 | Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip |
| 315 | Supply , fixing testing and commissioning of 11 KV 400 A Gang operated Switch ( link set) CPRI approved on the channel iron X- arms, and copper link, complete with manually operated equipment and accessories required for their satisfactory operation for their use on distribution sub-station and tapping points of 11KV lines and shall comply with the indian standard specification IS:2544,IS:5340 ( Part-iii) and IS :9921 ( part I -V)with all allied accessories. ( Complete job) |
| 316 | Supply , fixing testing and commissioning of 11 KV 400 A D.O.fuse set on the channel iron X- arms. |
| 317 | Supply , fixing testing and commissioning of 11 KV L.A. Set station type on the channel iron X- arms broad base type standard make |
| 318 | S/I , testing and commissioning of an out door type 250 KVA, Copper wound ,3-phase, oil cooled, 50 Hz,11/0.44 KV distribution transformer ( level-2) provided with tap changer, silcagel breather, conservator tank, oil gauge, Type test approved. North suns/Alba/NGG/Zain make.the job also includes mechanical/ manual carriage upto the site. The transformer should be of standard make dully isi marked and manufacture unit should have CPRI Registration and BIS Certificate upto required capacity levelThe complete testing of transformer will be carried out at manufacturing site by departmental representatives before assembling of same and contracting firm has to facilate in all aspects the deptt representatives upto manufacturing site for the said job. The job further includes comphrensive maintenance contract (with p/f of spares if needed) of Transformer for a period of three years reckoned from date of sucessful comissioning |
| 319 | Supply installation testing and comm.of 35 mm Sq. ABC Cable 11KV grade standard make including cable Hook. |
| 320 | Supply fixing testing and commissioning of 11 KV cable kit standard make. |
| 321 | S/L , testing and commissioning of PVC alluminium armoured cable 11000 volt grade Al. armoured cable Havel/Eq. standard make. |
| 322 | a)120 sq. mm single core |
| 323 | Supply installation testing and comm. Of 4'x3'x1' control pannel outdoor type sheet steel 16SWG powder coated phosphatised having angle iron stand fitted with following accessories to be grouted in the cement concrete, complete job |
| 324 | a) 600 amp 4 strip bus 1 No. |
| 325 | b) A/V meters set/indicators |
| 326 | d) 400 Amp TPN MCCB 50 K including spreader links, ( Adjustable thermal and magnetic release) Legrand/ Shinider/L&T/ Eq. standard make. |
| 327 | Supply, installation, mechanical erection, testing and commissioning of three phase 125 KVA diesel generator set KIRLOSKAR/Cummins/ Mahindra/ EICHER make/ equivalent standard make as desired by engineer incharge. ( sample to be approved before installation),coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f. mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer with required arrangements for exhaust to the exterior as directed.,4) AMF Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories and 7)Testing equipments as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer.8) first fuel fill, turbo charged developing required BHP 1500 RPM under NTP with 10 % overloading factor, six cylinder engine , with microprocessor based digital display genset engine controller for monitoring, metering, protection, control system etc. conforming to latest Govt. Emission norms CPCB-IV, Test certificate to be provided by the manufacturer.Refer Annexure-A for technical Specification.The job further includes comphrensive maintenance contract (with p/f of spares if needed) of DG set for a period of three years reckoned from date of sucessful comissioning. |
| 328 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 329 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 330 | S/I testing and comm. Of three phase 150 KVA 50HZ oil cooled(Transformer oil is to be provided with stabilizer conforming to IS 335,IEC296)) unbalanced type servo voltage stabilizer(Electricfield / COSCO/ Chinar make) having an input voltage ranging from 156V to 415 V ( phase to phase) and balanced output voltage of 415V, +/- 1%. ( Test certificate to be provided by the manufacturer) The unit incorporate |
| 331 | a) 0-500V moving iron type voltmeter with selector switch. |
| 332 | b) A three phase change over switch to read voltage on incoming and output side |
| 333 | c) indicating lights 6 No two numbers for each of the motorised units, one for lower limit and other for higher limit. |
| 334 | d) six push button control for movement operation of three motorised dimmer units two for each unit i.e one for raise operation and one for lower operation under the conditions of adjustment of auto/mannual selector switch (DPDT) |
| 335 | e) Single phase Preventer ( contactor Switch of required rating) Legrand make. |
| 336 | f) six potential meter resistance with lock meter two for each phase control, one for sensitivity and other for level control. |
| 337 | g) two sets of indication lamps three numbers each to indicate output and input indication |
| 338 | h) 20 % over load bearing capacity for one hour. |
| 339 | Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement). |
| 340 | Carrying out Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete, with Mild steel and medium tensile steel bars |
| 341 | Design,Supplying,Installation,Testing and Commissioning of Cubical Type double door, outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) General Floor Distribution Panel.The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved. Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick. ( As per approved design,size may vary as per site requirement) |
| 342 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 343 | Normal INCOMING: |
| 344 | a)400 Amp TPN MCCB 50 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/Semiens make. |
| 345 | b) 600 amp 4 strip bus 1 No. |
| 346 | c) Digital A/V meters set/indicators/ selector switches |
| 347 | d) onload Change over switch 300 Amp for generator.Front operated. |
| 348 | e) 4 No. of Aluminium Bus Bar of 600 Amp. |
| 349 | c) Digital A/V meters set/indicators/ selector switches |
| 350 | OUTGOING: |
| 351 | a)250 Amp TPN MCCB 50 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make. |
| 352 | a)200 Amp TPN MCCB 50 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make. |
| 353 | a)100 Amp TPN MCCB 36 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens make. |
| 354 | c) space for 18 way MCB's |
| 355 | S/L , testing and commissioning of PVC XLPE insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 356 | c)185 sq.mm 3.5 core |
| 357 | d)150 sq.mm 3.5 core |
| 358 | Design,Supplying,Installation,Testing and Commissioning of Cubical Type double door, outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) General Floor Distribution Panel.The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.(Wall Mounted) Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick. ( As per approved design,size may vary as per site requirement) |
| 359 | Normal INCOMING: |
| 360 | b)250 amp TPN MCCB 36 K including spreader links,( Adjustable thermal and magnetic release) Legrand/ Shinider/L&T/ sample to be approved before installation.. |
| 361 | b) 4 No. of Aluminium Bus Bar of 400 Amp. |
| 362 | c)Digital meters and phase indicators -1 set. |
| 363 | b)200 amp TPN MCCB 36 K including spreader links,( Adjustable thermal and magnetic release) Legrand/ Shinider/L&T/ sample to be approved before installation.. |
| 364 | b) 4 No. of Aluminium Bus Bar of 400 Amp. |
| 365 | c)Digital meters and phase indicators -1 set. |
| 366 | b)100 amp DP MCCB 16 K including spreader links,( Adjustable thermal and magnetic release) Legrand/ Shinider/L&T/ sample to be approved before installation.. |
| 367 | b) 2 No. of Aluminium Bus Bar of 200 Amp. |
| 368 | c)Digital meters and phase indicators -1 set. |
| 369 | OUTGOING: |
| 370 | c) 40-63amp TPN MCB 10 KA Legrand/ Shinider/ABB/L&T sample to be approved before installation.. |
| 371 | c) 40 amp DP MCB 10 KA Legrand/ Shinider/ABB/L&T sample to be approved before installation.. |
| 372 | c) space for 18 way MCB's |
| 373 | SITC of on-line UPS 1 X 60 KVA three phase in three phase out with isolation Transformer with 60 minutes battery back up each complete with SMF VRLA type battery bank with minimum VAH of 48000 (each bank should have 48000VAH of batteries ) including MS battery racks, Link sets, Battery breakers, UPS to battery bank cable.The ups & batteries shall have comprehensive warranty of 4 years from the date of successful commissioning.The specifications are mentioned below.Rating 6OKVA / Input Phase 3PH+N+PE,/ Input voltage 3 phase-380/400/415V (selectable) /Input Frequency 45-55 Hz-55 H2 @ 50Hz, Auto sensing for 50/60 Hz, /Input power factor> 0.99/Generator Input support/ THDI <2% linear load/Rated output active power 72KW/Output voltage 3 phase-380/400/415 V (selectable)/Output power factor 0.9 leading/Outout wave form pure sine wave/Voltage variation +/- 1%/Load Crest Ratio>31/ Overload capacity 105%~110%-60 min~110%~125%-10 min~125%~150%-1'min/ Efficiency upto 94% double conversion mode/Operating temperature 0-45 deg C/Relative Humidity 0- 95%/ Noise level <55 Bm/Display LCD+ LED/Safety comply to CE/Backuptime 60 minutes (Minimum VAH-48000 for each UPS ), Make of UPS :- APC / VERTIV/BORRI /Eaton Make :- Make of batteries VRLA SMF AMARON Quanta / Exide/ Equivalent . The Job includes CMC Contract for for a period of three years reckoned from date of sucessful handing over of site to intending departnment (The CMC Includes replacement of damaged accessories /devices by fresh one during CMC Period) of Eaton /APC /Schneider / Vertiv make |
| 374 | (UPS Panel)Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) |
| 375 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 376 | Normal INCOMING: |
| 377 | a)200A 4P MCCB 36 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make. |
| 378 | b) 4 No. of Aluminium Bus Bar of 500 Amp. |
| 379 | c)Digital meters and phase indicators -1 set. |
| 380 | OUTGOING: |
| 381 | a)200A 4P MCCB 36 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make. |
| 382 | b) 4 No. of Aluminium Bus Bar of 400 Amp. |
| 383 | c) 63amp TPN MCB 10 KA Legrand/ Shinider/ABB/L&T sample to be approved before installation.. |
| 384 | c) space for 12 way MCB's Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayJul 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer