Housing Urban and Rular Development Government Departments Closing in 1 days TDR #56212366

Tender For Construction Of Bio Lab, Physics Lab, Chemistry Lab, Computer Room, Library Room & Additional Classrooms Dounle Story Building At Girls Higher Secondary School Sogam District Kupwara Advertised Cost 128.43 Lacs

Issued by Government Departments · Kupwara, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Jul 2026
1 days left
EMD
2.57 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kupwara → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Bio Lab, Physics Lab, Chemistry Lab, Computer Room, Library Room & Additional Classrooms Dounle Story Building At Girls Higher Secondary School Sogam District Kupwara Advertised Cost 128.43 Lacs

BOQ

Name of Work:- Construction of Bio Lab, Physics Lab, Chemistry Lab, Computer room, Library Room & additional Classrooms dounle story building at Girls Higher Secondary School Sogam District Kupwara Advertised Cost 128.43 lacs
Sl. No. Item Description
1PART (A) CIVIL PART:Earth work in excavation by mechanical means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in with) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting ouf excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil:
2Providing and laying of dry stone soling by way of nallah boulders size on leveL (hand packed) watering, ramming, complete below foundation and rooms incl. carriage of all materials
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering incl. all carriages of material to site of work 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Crusher.
4Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, . All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) Crusher. Incl. all carriage upto site of work.
5Providing and laying in position specified grade of cement concrete including curing but excluding the cost of centering, shuttering, All works upto plinth with1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) Crusher. Incl. all carriage upto site of work.
6Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases above plinth level upto floor five level, including curing but excluding the cost ofcentring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) including all carriages of material.
7Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Crusher incl. all carriages of material upto site of work.
8Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. As per directions of Engineer-in-Charge.
10Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns for mass concrete
11Centering & Shuttering incl. strutting, propping etc. & removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers.
12Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms.
13Centering and shuttering including strutting, propping etc. and removal of form for Stairs (excluding landings) except spiral staircases.
14Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide.
15Brick work with F.P.S bricks of class designation 7.5 in superstructur above Plinth in cement mortar in 1:6 (1 cement: 6 coarse sand) complete including extra upto floor V-level. incl. all carriages of material upto site of work.
1615mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand mortar)
17Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50mm thick with 20 mm nominal size stone aggregate.
18Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mmnominal size well rammed and consolidated and grouted with fine sand including necessaryexcavation, leveling and dressing and finishing the top smooth and curing complete.
19Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick.
20Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
21Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with whitecement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown
22Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, inskirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete.
23Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Imported wood
24Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panesIncluding ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Kiln seasoned and chemically treated hallock wood 35 mm
25Providing and fixing wire gauze shutters using galvanized M.S. wire gauze ofaverage width for aperture 1.4 mm in both directions with wire of dia. 0.63 mmfor doors, windows and clerestory windows with ISI marked M.S. pressed butthinges bright finished of required size with necessary screws as per direction ofEngineer-in-charge :Kiln seasoned and chemically treated hallock wood 35 mm
26Providing and fixing 35 mm thick factory made laminated veneer lumber doorshutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butthinges of required size with necessary screws, all complete as per directions ofEngineer- in-charge and panelling with panels of :(Note:- Butt hinges and necessary screws shall be paid separately)12 mm thick pre-laminated particle board (decorative lamination onboth sides) grade-I, medium density flat pressed three layer particle board FPTIor graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP typesynthetic resin adhesive as per IS: 848 and pre-laminated conforming to IS:12823, Grade-I, Type-II marked
2712mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand )
28Providing and fixing of Float Glass Panes 4 mm thick glass pane (weighing not less than 10 kg/sqm) all complete as per directions of EIC.
29Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded etc as per directions of Engineer-in-Charge.
30Providing corrugated coloured G. S. sheet roofing fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter withbitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto a pitch of 60 degrees)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm all complete job.
31Providing and fixing of coloured plane sheet for Ridges/valleys including cost of nails and washers
32Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
33Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer all complete job.
34painting steel work with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture all complete.
35Painting wood work with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade on new work (two ormore coats) over an under coat of suitable shade with ordinary paint of approved brand and manufacture all complete.
36Providing and Fixing aluminium hardware fittings Aldrop with lock
37Providing and Fixing aluminium hardware fittings Tower bolt 150 mm x 10 mm
38Providing and Fixing aluminium hardware fittings Tower bolt 100 mm x 10 mm
39Providing and Fixing aluminium hardware fittings Handle 125mm
40Providing and Fixing aluminium hardware fittings Handle 100mm
41Providing and Fixing aluminium hardware fittings Hooks
42Providing and fixing stainless steel (Grade 304) railing made of Hollowtubes channels, plates etc. including welding ,grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete ,including fixing the railingwith necessary accessories and stainless steel dash fasteners, stainless steelbolts etc. of required size, on the top of the floor or the side of waist slabwith suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.).
43Supply and installation of satin finish 304 stainless steel posts having 100mm dia tube, erected with chemical grout to be fixed on the top of slab/skirting (spigot Fixed) at corners complete, as manufactured by Dline or approved equivalent & shall be fixed above the finished level complete as per architectural drawings.
44Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) : natural colour insulating board 12mm
45Providing wood work in celling frames as a base for fixing of celling PLY/ of, fixed in position imported KD wood including nails screws all hardware items complete job as directed by engineer in charge.
46Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08 and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigmentsSize of tile 600x600 mm
47Sanitary and PlumbingProviding and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusionwelded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. Thisincludes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etcspacing PN-16 pipe , 25mm OD(SDR-7.4)
48Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusionwelded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. Thisincludes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etcspacing PN-16 pipe , 32mm OD(SDR-7.4)
49Supply Installation testing and commissioning of gunmetal, male or female threaded isolation control valve of approved quality confirming to IS 778, PN-10, with necessary specials, unions, nipples etc.25mm Dia
50Supply Installation testing and commissioning of gunmetal, male or female threaded isolation control valve of approved quality confirming to IS 778, PN-10, with necessary specials, unions, nipples etc.32mm Dia
51Providing and fixing PPR UnionsPPR Union 32mm
52Providing and fixing G.I. pipes medium complete with G.I. fittings includingtrenching and refilling etc. (external work) complete job25 mm dia
53Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings.Flat back wash basin of size 630x450 mm.
54Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
55Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms.
56Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
57Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
58Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm
59Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
60Providing and fixing C.P single hole mixer for wash basin
61Providing and fixing C.P wall mixer(jaquare) of approved make including cutting and making good the walls werever required all complete
62Providing & fixing of C.P tubes of approved make 450 mm to 600 mm long
63Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not lessthan 690 gms
64Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
65Drainage and Disposal:Providing and fixing P.V.C pipe and pipe fittings of the following nominal dia to P.V.C. soil/waste/ventilating pipes, excluding cost of holder bats.Pipe 100 mm
66Floor trap 100mm
67door T 100 mm
68Collars 100 mm
69Reducer 100 x 50 mm
70Pipe 75 mm
71Floor trap 75mm
72Door T 75 mm
73Collars 75 mm
74Pipe 50mm
75Cone covel 50 mm
76PVC waste pipe
77Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight ofcover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 all complete
78Providing and fixing of master trap of approved quality and make. All complete
79Providing and fixing of 3-layer water storage tanks of approved quality and make all complete
80Providing and fixing of white vetrios china lab. Sink incl making of all connection All complete
81Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machinecut for kitchen platforms, vanity counters, window sills, facias and similar locations, ofrequired size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed withmatching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing toedges to give high gloss finish etc. complete at all levels Granite of any colour or shade all complete job
82PART B Electrical :Wiring for Light point/Fan point/Exhaust fan/Bell point with(P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Anchor/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch, Modular Plate, Cover in front & suitable GI box etc ISO/EC Certified/Schneider/ Havells/ Legrand/Anchor roma plus ABB Eq.Make & items shall be approved before execution of work by SDO. (Group A)
83Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required, ISO/IECCertified of Havells/ Legrand/Anchor/Schneider /ABB/Eq Make & shall be approved before execution of work by SDO.
84Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVCInsulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq Make)
85Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISEC Certified/Legran/Anchor roma plus/Schneider/ABB/Eq Make & shall be approved before execution of work by SDO
86Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mmFRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq. Make)
87Supplying and fixing suitable si. : GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non. residential buildings), ISO/IEC Certified Havells/Legrand/ Anchor roma plus Schneider/ABB/Eq.Make & shall be approved before execution of work
88Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Anchor/ Eq Make) & shall be approved before execution of work (Including Cost of Conduit/Channel)
892 X 10 sq. mm + 1 X 6 sq. mm earth wire
902 X 6 sq. mm + 1 X 6 sq. mm earth wire
912 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
92Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,C Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB. DB Complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq.Make)
93Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections.(L&T/Siemens /Legrand/Havells/ABB/Eq Make)
9463 Amp
9540 Amp
96Supplying and Fixing of MCB way 6-way (4 + 18), horizontal typed, sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make)
97Supply/Installation/Testing and Commissioning of 18W + LEDConceal/Surface (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 Im/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70..The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix/Eq Make.
98Providing & Fixing of 1K0X IP-66 protected high power LED 50 Watt flood light yotem with single prece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 walt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >-125 Im/wt. LED driver Input Voltage AC: 120 to 270 V AC with High voltage Cutoff (@=300 V AC and Auto resetting Safety Power Factor >0.95, THD() <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector.Surge Protection Min >-4K V internal and 10K V external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allowtraceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures.(IM79/M80) Certificate/ report with liable warranty of product/accessories fromOEM shall be submitted. All as per pre approved by Engincer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/t of suitable size of Gyser bolt. The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning handing over of site to intending department.
99Supply, Installation, Testing and Commissioning of decorative 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete. USHA Striker/Havells Oyster matalic/CromptonAura/equivalent make as directed by engineer incharge.
100Supply/Installation/Testing and Commissioning of 225-250mmShutter Typed,320 Cum/HrAC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection ete USHA/Havells/Crompton/Eq. Make.(Min 1- star)
101Supply/Laying/Connecting and Commissioning of 50 sq.mm 3.5-CoreXLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-l and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth oi 50 CM including excavation and Refilling the Trench (Material to be approved before execution)
102Supply/Installation/Testing and Commissioning of CPRI Approved (IS/I:C:61439) Main Controlling Panel, fabricated out of heavy gauge sheet steel dully Painted with powder coated paint dust protected ,carth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT|Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified. The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 125 Amp-4-Pole ,36kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved-01 No.b) 200 Amps TPN Al. Bus Bar Set - 01 Set, Digital Voltmeter Ammcter,C.T Coils with Selector Switch & Phase indicator Set.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter etc load(a) 63-Amp DP MCB - 02 No. for Heating Sub-main.(b) 40-Amp DP MCB- 02 No. for Lighting/Machine Sub-main
103ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPERRod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of20MM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56212366
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 08-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Bio Lab, Physics Lab, Chemistry Lab, Computer Room, Library Room & Additional Classrooms Dounle Story Building At Girls Higher Secondary School Sogam District Kupwara Advertised Cost 128.43 Lacs
Basic Detail
Tender No NIT 13
Bidding Type Tender
Location
City Kupwara
State Jammu and Kashmir
Key Dates
Publish Date 29 Jun 2026
Submission Date 08 Jul 2026
Open Date 09 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 2600
EMD 2.57 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_1016229.xls
ea02498e-a66d-40b1-bb88-37a9a5c4ed74.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_1016229.xls

html

ea02498e-a66d-40b1-bb88-37a9a5c4ed74.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders