Power Boards / Undertakings / PSU Closing in 22 days TDR #56211661

Bids Are invited for Custom Bid For Services - Misc. Electrical Maintenance/Oh Of Power Plant Lt Systems/Battery And Battery Chargers/Dcdb/Lighting Maintenance Street Lighting/ Electrical Shift Maintenance Jobs/Eot Crane Hoist, Vfd, Fire Fighting, Hy

Issued by Boards / Undertakings / PSU · Sonbhadra, Uttar Pradesh
Tender Value
74.15 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
22 days left
EMD
1.25 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonbhadra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are invited for Custom Bid For Services - Misc. Electrical Maintenance/Oh Of Power Plant Lt Systems/Battery And Battery Chargers/Dcdb/Lighting Maintenance Street Lighting/ Electrical Shift Maintenance Jobs/Eot Crane Hoist, Vfd, Fire Fighting, Hydrogen Plant, Dm .. - Routine Maintenance Of Elctrical System Of E.O.T. Cranes/Hoist Of Different Capacity Installed At Different Locations In 3X210 Mw Atps Anpara. (17 Nos. Eot Cranes/Hoist) , Maintenance Of Eot Crane (2 Nos.) As Per Scope Of Work. , Repair Of Electromagnetic Brake. , Repair Of Electro Hydraulic Thruster. , Repair Of Pendent Control Push Button For Motion Control. , Repair Of Gravity / Rotary / Lateral Limit Switches. , Repair Of Resistance Box. , Repair Of Control Transformer 415/110V 1-Phase 50 Hz, 500Va. , Eot Crane Of T-G Hall 115 T , Eot Crane Of Cw Pump House 50 T , Eot Crane Of Ash Slurry Pump House 7.5 T , Eot Crane Of Intake 12.5 T , Electrical Hoist At Ash Water Pump House 2.5 T , Electrical Hoist At Boiler Area Of Capacity 10.0 T. , Electrical Hoist Of Aux Water Pump House 7.5 T. , Break Down Maintenance Of 24 Vdc/220 Vdc Trickle Charger / Quick Charger / Battery Terminal Panels Including Replacement Of Defective Parts And Re Commissioning. , Repair & Maintenance Of Complete Variac Of + 24 Vdc G1/G2 Battery Trickle / Quick Charger / Replacement Of Defective Parts, Testing & Commissioning. , Break Down Maintenance Of Dc Control Panel Of E.O.P. Motor Including Checking Of Control Circuit & Replacement Of Defective Parts Like Contractors, Switches Etc. , Repair & Maintenance Of Complete Variac Of 220 Vdc Trickle / Quick Charger / Replacement Of Defective Parts, Testing & Commissioning. , Break Down Maintenance Of Control Panels Of D.G. Set Including Fault Finding And Replacement Of Defective Parts. , Repair And Maintenance Of 24 Vdc Charger Of D.G. Set Battery. , Repair & Reconditioning Of Battery Of D.G. Set Of 12 V X 2 Of 135 Ah. , Dismantling, Repair & Reconditioning, Reinstallation, Painting With Acid Proof Paint And Re-Commissioning Of 2.1 V Cell Unit. , Break Down Maintenance Of 220 Vdc Trickle / Quick Charger Extension Panel At 11.00 Meter Vddc Room. , Break Down Works At 24 Vdc / 220 Vdc D.B. Modules At 11.00 M Vddc Room Including Attending Of Flash Over Area / Replacement Of Fuse Carriers / Switches Etc. , Break Down Maintenance Due To Fire Or Flashover On Any Portion Of The Bus Bar Of 0.4 Kv Systems Including Reassembling Of The Section And Re-Commissioning After Achieving I.R. Values. , Break Down Maintenance Of L&T/Ee/Ge Make Breakers Of 0.4 Kv System Including Replacement Of Damaged / Defective Parts. , Break Down Maintenance Of 0.4 Kv Motor Feeder Modules Including Fault Finding Of Control Circuit & Replacement Of Damaged / Defective Parts Like Contractors/ Emrs/ Switches /Fuse Carriers Etc. And Tightness Of Cable Termination At Mcc And Motor Both The End. , Break Down Maintenance Of 0.4 Kv Modules Other Than Motor Feeders Including Replacement Of Damaged/Defective Parts Like Switches/Fuse Carriers Etc. , Replacement Of Protection Relays / Bus Ct/ Bus Pt Etc. Including Rectification Of The Fault Of Associated Circuit. , Checking & Replacement Of Damaged Heaters, Its Control Circuit Parts & Re-Commissioning Of Compressors. , Break Down Maintenance Of Control Circuit Panel Of Condenser And Chiller Pumps Motors Including Fault Finding Of Control Circuit, Replacement Of Defective Parts & Set Right The Local As Well As Remote Operation. , Repair / Replacement Of Defective Switches Such As Local / Remote, Trip / Close Auto / Manual Etc. Of Bus Bar Cubicle Or Panels. , Break Down Maintenance Of Star Delta Starter & Tpn Switches Of 40 Kw To Below110 Kw Motors In Air Conditioning Plant . , Checking &Replacement Of Defective Parts Of Disconnecting Switches (Knife Switches) Such As Ferrules / Connectors / Insulators / Lugs Etc. , Daily Upkeeping Of Electrical Parts Of Central Ac Plant Comprises Of Ucb,Mcb, Service House Building, Esp Control Rooms , Round The Clock Operation & Maintenance Of Permanent Station Lighting System Of Ucb-1,2 &3, T.G. Hall Area, Boiler House Area Including I.D./F.D./P.A. Fan Area, Esp Area Including Their Control Rooms, Dg Set Room, Compressor House, Transformer Yard, Ash Water Pump House, Service House Building, M.Cc. Rooms, Switch Gear Rooms, Battery Rooms, (-4) M & (+) 5.5 M Level Cable Gallery, D.M. Plant, C.W. Pump House, Aux. Pump House, Filtration Plant, P.T. Plant, Magazine Post, Fire Pump House, Mechanical Workshop, Vehicle Base, Store Yard & Its Sheds, ‘A T.P.S. Canteen, Junior Engineers & Operators Cabins And Site Offices, Street Light, Tower Light (Excluding Those Installed In Switch Yard & In C.H.P. Areas), C.M.R. System, Loading / Unloading Site, Street Light In M.G.R. Workshop Area, Internal Telephone Exchange Pertaining To ‘A T.P.S., Anpara. , Bush Cutting/Cleaning Around The Lighting Installations Of Permanent Station Lighting System Such As L.D.B.S, J.B.S, Street Light Poles, Over Head L.T. Lines Installed At Different Locations, As Mentioned Above, Of ‘A T.P.S., Anpara. , Cutting / Trimming Of Tree Branches Around The Lighting Installations Of Permanent Station Lighting System Such As L.D.B.S, J.B.S, Street Light Poles, Over Head L.T. Lines Installed At Different Locations Of ‘A T.P.S., Anpara. , Removal Of Old Burnt / Damaged Cables & Wires Of Conduit Wiring From Conduit And Re Wiring Of Different Size Cables/ Wires In Conduit Including Re Fixing Of Conduit, Wherever It Is Hanging, At -4.0 M, 0.0 M, 3.5M And 5.5 M Elevation Of T.G Hall Area. , Removal Of Old Burnt/ Damaged Cable & Wires Of Conduit Wiring From Conduit At Different Elevation Of Boiler House/Tg Hall And Rewiring Of Different Size Cable/ Wires In Conduit As Per Site Requirement Including Re-Fixing Of Conduits Wherever It Is Hanging. , Repairing Of Ladder Associated In Lighting System , Installation Of New Light Fittings. Of Different Wattage , Installation Of New / Replacement Of Damaged Welding Branch Board/ Main Switch Carrier/Replacement Of Ldb , Installation Of New Electrical Points , Bush Cleaning In 02 M Wide Area Along The Cable Route. , Work Of Supply, Installation And Commissioning Of 8X10x4 Size Distribution Box On Street Light Poles. , Work Of Casting Of Street Light Pole Rcc Plinth. , Work Of Repairing Of Damaged Round Poles Of Streetlight. , Work Of Dismantling And Removal Of Street Light Pole. , Work Of Complete Installation Of Light Pole With Fixing Of One Number Of Hpsv/Hpmv/Led L Fitting, Distribution Box Fuse Unit And Gi Pipe Of 35 Mm. Size. , Complete Repairing/Rewinding Related Maintenance Works Of Panel Mounted Air Cooled, Dry Type,50 Kva&75Kva Isolation Lighting Transformer Installed At Various Locations In Permanent Station Lighting System. , Complete Rewinding Of Damaged / Burnt Panel Mounted Air Cooled, Dry Type, 3 Phase, 75 Kva Isolation Transformer Having Voltage Ratio 415 V / 433 V, Insulation Class ‘B, Primary Side Tapping +/- 2.5 %, Secondary Side Tapping +/- 5.0 %, Off Circuit Copper Link Type Connection. , Replacement Of Bakelite Sheet In 60 Cm X 25 Cm X 01Cm Size Having 26 Nos. Of Holes On It. , Replacement And Fixing Of Nuts & Bolts In 05Mmx05mm. Size , Servicing & Double Coat Spray Varnishing Of Panel Mounted, Air Cooled, Dry Type, 3 Phase, 75 Kva Isolation Transformer Having Voltage Ratio 415V/433 V, Insulation Class ‘B, Primary Side Tapping +/- 2.5 %, Secondary Side Tapping +/- 5.0 %, Off Circuit Copper Link Type Connection Including Minor Repairing Work Such As Brazing Of Connections, Tightening Of Nuts & Bolts Etc. And Its Re Commissioning.

BOQ

Sl. No. Item TitleItem Description
1Routine Maintenance of elctrical system of E.O.T. Cranes/hoist of different capacity installed at different locations in 3X210 MW ATPS Anpara. (17 Nos. EOT Cranes/Hoist)Routine Maintenance of elctrical system of E.O.T. Cranes/hoist of different capacity installed at different locations in 3X210 MW ATPS Anpara. (17 Nos. EOT Cranes/Hoist)
2Maintenance of EOT Crane (2 nos.) as per scope of work.Maintenance of EOT Crane (2 nos.) as per scope of work.
3Repair of electromagnetic brake.Repair of electromagnetic brake.
4Repair of electro hydraulic thruster.Repair of electro hydraulic thruster.
5Repair of pendent control push button for motion control.Repair of pendent control push button for motion control.
6Repair of gravity / Rotary / Lateral limit switches.Repair of gravity / Rotary / Lateral limit switches.
7Repair of Resistance box.Repair of Resistance box.
8Repair of control transformer 415/110V 1-PHASE 50 Hz, 500VA.Repair of control transformer 415/110V 1-PHASE 50 Hz, 500VA.
9EOT Crane of T-G Hall 115 TEOT Crane of T-G Hall 115 T
10EOT Crane of CW Pump House 50 TEOT Crane of CW Pump House 50 T
11EOT Crane of Ash Slurry Pump House 7.5 TEOT Crane of Ash Slurry Pump House 7.5 T
12EOT Crane of Intake 12.5 TEOT Crane of Intake 12.5 T
13Electrical Hoist at Ash Water Pump House 2.5 TElectrical Hoist at Ash Water Pump House 2.5 T
14Electrical Hoist at Boiler area of capacity 10.0 T.Electrical Hoist at Boiler area of capacity 10.0 T.
15Electrical Hoist of Aux water Pump House 7.5 T.Electrical Hoist of Aux water Pump House 7.5 T.
16Break down maintenance of 24 VDC/220 VDC Trickle charger / quick charger / battery terminal panels including replacement of defective parts and re commissioning.Break down maintenance of 24 VDC/220 VDC Trickle charger / quick charger / battery terminal panels including replacement of defective parts and re commissioning.
17Repair & maintenance of complete variac of + 24 VDC G1/G2 battery trickle / quick charger / replacement of defective parts, testing & commissioning.Repair & maintenance of complete variac of + 24 VDC G1/G2 battery trickle / quick charger / replacement of defective parts, testing & commissioning.
18Break down maintenance of DC control panel of E.O.P. motor including checking of control circuit & replacement of defective parts like contractors, switches etc.Break down maintenance of DC control panel of E.O.P. motor including checking of control circuit & replacement of defective parts like contractors, switches etc.
19Repair & maintenance of complete variac of 220 VDC trickle / quick charger / replacement of defective parts, testing & commissioning.Repair & maintenance of complete variac of 220 VDC trickle / quick charger / replacement of defective parts, testing & commissioning.
20Break down maintenance of control panels of D.G. set including fault finding and replacement of defective parts.Break down maintenance of control panels of D.G. set including fault finding and replacement of defective parts.
21Repair and maintenance of 24 VDC charger of D.G. set battery.Repair and maintenance of 24 VDC charger of D.G. set battery.
22Repair & reconditioning of battery of D.G. set of 12 V x 2 of 135 AH.Repair & reconditioning of battery of D.G. set of 12 V x 2 of 135 AH.
23Dismantling, repair & reconditioning, reinstallation, painting with acid proof paint and re-commissioning of 2.1 V cell unit.Dismantling, repair & reconditioning, reinstallation, painting with acid proof paint and re-commissioning of 2.1 V cell unit.
24Break down maintenance of 220 VDC Trickle / quick charger extension panel at 11.00 meter VDDC room.Break down maintenance of 220 VDC Trickle / quick charger extension panel at 11.00 meter VDDC room.
25Break down works at 24 VDC / 220 VDC D.B. Modules at 11.00 M VDDC room including attending of flash over area / replacement of fuse carriers / switches etc.Break down works at 24 VDC / 220 VDC D.B. Modules at 11.00 M VDDC room including attending of flash over area / replacement of fuse carriers / switches etc.
26Break down maintenance due to fire or flashover on any portion of the bus bar of 0.4 KV systems including reassembling of the section and re-commissioning after achieving I.R. values.Break down maintenance due to fire or flashover on any portion of the bus bar of 0.4 KV systems including reassembling of the section and re-commissioning after achieving I.R. values.
27Break down maintenance of L&T/EE/GE make breakers of 0.4 KV system including replacement of damaged / defective parts.Break down maintenance of L&T/EE/GE make breakers of 0.4 KV system including replacement of damaged / defective parts.
28Break down maintenance of 0.4 KV motor feeder modules including fault finding of control circuit & replacement of damaged / defective parts like contractors/ EMRs/ Switches /Fuse carriers etc. and tightness of cable termination at MCC and motor both the end.Break down maintenance of 0.4 KV motor feeder modules including fault finding of control circuit & replacement of damaged / defective parts like contractors/ EMRs/ Switches /Fuse carriers etc. and tightness of cable termination at MCC and motor both the end.
29Break down maintenance of 0.4 KV modules other than motor feeders including replacement of damaged/defective parts like switches/fuse carriers etc.Break down maintenance of 0.4 KV modules other than motor feeders including replacement of damaged/defective parts like switches/fuse carriers etc.
30Replacement of protection relays / bus CT/ Bus PT etc. including rectification of the fault of associated circuit.Replacement of protection relays / bus CT/ Bus PT etc. including rectification of the fault of associated circuit.
31Checking & replacement of damaged heaters, its control circuit parts & re-commissioning of compressors.Checking & replacement of damaged heaters, its control circuit parts & re-commissioning of compressors.
32Break down maintenance of control circuit panel of Condenser and chiller pump’s motors including fault finding of control circuit, replacement of defective parts & set right the local as well as remote operation.Break down maintenance of control circuit panel of Condenser and chiller pump’s motors including fault finding of control circuit, replacement of defective parts & set right the local as well as remote operation.
33Repair / replacement of defective switches such as local / remote, trip / close auto / manual etc. of Bus Bar cubicle or panels.Repair / replacement of defective switches such as local / remote, trip / close auto / manual etc. of Bus Bar cubicle or panels.
34Break down maintenance of star delta starter & TPN switches of 40 KW to below110 KW motors in Air Conditioning plant .Break down maintenance of star delta starter & TPN switches of 40 KW to below110 KW motors in Air Conditioning plant .
35Checking &replacement of defective parts of disconnecting switches (knife switches) such as ferrules / connectors / insulators / Lugs etc.Checking &replacement of defective parts of disconnecting switches (knife switches) such as ferrules / connectors / insulators / Lugs etc.
36Daily Upkeeping of electrical parts of central ac plant comprises of UCB,MCB, Service house Building, ESP control RoomsDaily Upkeeping of electrical parts of central ac plant comprises of UCB,MCB, Service house Building, ESP control Rooms
37Round the clock operation & maintenance of Permanent Station lighting System of UCB-1,2 &3, T.G. Hall Area, Boiler House Area including I.D./F.D./P.A. Fan Area, ESP Area including their control rooms, DG Set Room, Compressor House, Transformer Yard, Ash Water Pump House, Service House Building, M.CC. Rooms, Switch Gear Rooms, Battery Rooms, (-4) M & (+) 5.5 M Level Cable Gallery, D.M. Plant, C.W. Pump House, Aux. Pump House, Filtration Plant, P.T. Plant, Magazine Post, Fire Pump House, Mechanical Workshop, Vehicle Base, Store Yard & its Sheds, ‘A’ T.P.S. Canteen, Junior Engineer’s & Operator’s Cabins and Site Offices, Street Light, Tower Light (Excluding Those Installed in Switch Yard & in C.H.P. areas), C.M.R. System, Loading / Unloading Site, Street Light in M.G.R. Workshop area, internal telephone exchange pertaining to ‘A’ T.P.S., Anpara.Round the clock operation & maintenance of Permanent Station lighting System of UCB-1,2 &3, T.G. Hall Area, Boiler House Area including I.D./F.D./P.A. Fan Area, ESP Area including their control rooms, DG Set Room, Compressor House, Transformer Yard, Ash Water Pump House, Service House Building, M.CC. Rooms, Switch Gear Rooms, Battery Rooms, (-4) M & (+) 5.5 M Level Cable Gallery, D.M. Plant, C.W. Pump House, Aux. Pump House, Filtration Plant, P.T. Plant, Magazine Post, Fire Pump House, Mechanical Workshop, Vehicle Base, Store Yard & its Sheds, ‘A’ T.P.S. Canteen, Junior Engineer’s & Operator’s Cabins and Site Offices, Street Light, Tower Light (Excluding Those Installed in Switch Yard & in C.H.P. areas), C.M.R. System, Loading / Unloading Site, Street Light in M.G.R. Workshop area, internal telephone exchange pertaining to ‘A’ T.P.S., Anpara.
38Bush cutting/cleaning around the lighting installations of permanent station lighting system such as L.D.B.s, J.B.s, Street light poles, over head L.T. lines installed at different locations, as mentioned above, of ‘A’ T.P.S., Anpara.Bush cutting/cleaning around the lighting installations of permanent station lighting system such as L.D.B.s, J.B.s, Street light poles, over head L.T. lines installed at different locations, as mentioned above, of ‘A’ T.P.S., Anpara.
39Cutting / trimming of tree branches around the lighting installations of permanent station lighting system such as L.D.B.s, J.B.s, Street light poles, over head L.T. lines installed at different locations of ‘A’ T.P.S., Anpara.Cutting / trimming of tree branches around the lighting installations of permanent station lighting system such as L.D.B.s, J.B.s, Street light poles, over head L.T. lines installed at different locations of ‘A’ T.P.S., Anpara.
40Removal of old burnt / damaged cables & wires of conduit wiring from conduit and re wiring of different size cables/ wires in conduit including re fixing of conduit, wherever it is hanging, at -4.0 M, 0.0 M, 3.5M and 5.5 M elevation of T.G hall area.Removal of old burnt / damaged cables & wires of conduit wiring from conduit and re wiring of different size cables/ wires in conduit including re fixing of conduit, wherever it is hanging, at -4.0 M, 0.0 M, 3.5M and 5.5 M elevation of T.G hall area.
41Removal of old burnt/ damaged cable & wires of conduit wiring from conduit at different elevation of boiler house/TG hall and rewiring of different size cable/ wires in conduit as per site requirement including re-fixing of conduits wherever it is hanging.Removal of old burnt/ damaged cable & wires of conduit wiring from conduit at different elevation of boiler house/TG hall and rewiring of different size cable/ wires in conduit as per site requirement including re-fixing of conduits wherever it is hanging.
42Repairing of ladder associated in lighting systemRepairing of ladder associated in lighting system
43Installation of new light fittings. of different wattageInstallation of new light fittings. of different wattage
44Installation of new / replacement of damaged welding branch board/ main switch carrier/replacement of LDBInstallation of new / replacement of damaged welding branch board/ main switch carrier/replacement of LDB
45Installation of new electrical pointsInstallation of new electrical points
46Bush cleaning in 02 m wide area along the cable route.Bush cleaning in 02 m wide area along the cable route.
47Work of supply, installation and commissioning of 8”X10”X4” size distribution box on street light poles.Work of supply, installation and commissioning of 8”X10”X4” size distribution box on street light poles.
48Work of Casting of street light pole RCC plinth.Work of Casting of street light pole RCC plinth.
49Work of repairing of damaged round poles of streetlight.Work of repairing of damaged round poles of streetlight.
50Work of dismantling and removal of street light pole.Work of dismantling and removal of street light pole.
51Work of complete installation of light pole with fixing of one number of HPSV/HPMV/LED lamp fitting, distribution box fuse unit and GI Pipe of 35 mm. size.Work of complete installation of light pole with fixing of one number of HPSV/HPMV/LED lamp fitting, distribution box fuse unit and GI Pipe of 35 mm. size.
52Complete Repairing/Rewinding related maintenance works of panel mounted air cooled, dry type,50 KVA&75KVA Isolation Lighting Transformer installed at various locations in Permanent Station lighting System.Complete Repairing/Rewinding related maintenance works of panel mounted air cooled, dry type,50 KVA&75KVA Isolation Lighting Transformer installed at various locations in Permanent Station lighting System.
53Complete rewinding of damaged / burnt panel mounted air cooled, dry type, 3 phase, 75 KVA Isolation Transformer having Voltage Ratio 415 V / 433 V, insulation class ‘B’, Primary side tapping +/- 2.5 %, Secondary side tapping +/- 5.0 %, Off Circuit copper link type connection.Complete rewinding of damaged / burnt panel mounted air cooled, dry type, 3 phase, 75 KVA Isolation Transformer having Voltage Ratio 415 V / 433 V, insulation class ‘B’, Primary side tapping +/- 2.5 %, Secondary side tapping +/- 5.0 %, Off Circuit copper link type connection.
54Replacement of Bakelite sheet in 60 cm x 25 cm x 01cm size having 26 Nos. of holes on it.Replacement of Bakelite sheet in 60 cm x 25 cm x 01cm size having 26 Nos. of holes on it.
55Replacement and fixing of nuts & bolts in 05mmx05mm. sizeReplacement and fixing of nuts & bolts in 05mmx05mm. size
56Servicing & double coat spray varnishing of panel mounted, air cooled, dry type, 3 phase, 75 KVA Isolation Transformer having Voltage Ratio 415V/433 V, insulation class ‘B’, primary side tapping +/- 2.5 %, secondary side tapping +/- 5.0 %, off circuit copper link type connection including minor repairing work such as brazing of connections, tightening of nuts & bolts etc. and its re commissioning.Servicing & double coat spray varnishing of panel mounted, air cooled, dry type, 3 phase, 75 KVA Isolation Transformer having Voltage Ratio 415V/433 V, insulation class ‘B’, primary side tapping +/- 2.5 %, secondary side tapping +/- 5.0 %, off circuit copper link type connection including minor repairing work such as brazing of connections, tightening of nuts & bolts etc. and its re commissioning.

AI Tender Summary

OUR REF NO 56211661
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 74.15 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited
Work Description Bids Are invited for Custom Bid For Services - Misc. Electrical Maintenance/Oh Of Power Plant Lt Systems/Battery And Battery Chargers/Dcdb/Lighting Maintenance Street Lighting/ Electrical Shift Maintenance Jobs/Eot Crane Hoist, Vfd, Fire Fighting, Hydrogen Plant, Dm .. - Routine Maintenance Of Elctrical System Of E.O.T. Cranes/Hoist Of Different Capacity Installed At Different Locations In 3X210 Mw Atps Anpara. (17 Nos. Eot Cranes/Hoist) , Maintenance Of Eot Crane (2 Nos.) As Per Scope Of Work. , Repair Of Electromagnetic Brake. , Repair Of Electro Hydraulic Thruster. , Repair Of Pendent Control Push Button For Motion Control. , Repair Of Gravity / Rotary / Lateral Limit Switches. , Repair Of Resistance Box. , Repair Of Control Transformer 415/110V 1-Phase 50 Hz, 500Va. , Eot Crane Of T-G Hall 115 T , Eot Crane Of Cw Pump House 50 T , Eot Crane Of Ash Slurry Pump House 7.5 T , Eot Crane Of Intake 12.5 T , Electrical Hoist At Ash Water Pump House 2.5 T , Electrical Hoist At Boiler Area Of Capacity 10.0 T. , Electrical Hoist Of Aux Water Pump House 7.5 T. , Break Down Maintenance Of 24 Vdc/220 Vdc Trickle Charger / Quick Charger / Battery Terminal Panels Including Replacement Of Defective Parts And Re Commissioning. , Repair & Maintenance Of Complete Variac Of + 24 Vdc G1/G2 Battery Trickle / Quick Charger / Replacement Of Defective Parts, Testing & Commissioning. , Break Down Maintenance Of Dc Control Panel Of E.O.P. Motor Including Checking Of Control Circuit & Replacement Of Defective Parts Like Contractors, Switches Etc. , Repair & Maintenance Of Complete Variac Of 220 Vdc Trickle / Quick Charger / Replacement Of Defective Parts, Testing & Commissioning. , Break Down Maintenance Of Control Panels Of D.G. Set Including Fault Finding And Replacement Of Defective Parts. , Repair And Maintenance Of 24 Vdc Charger Of D.G. Set Battery. , Repair & Reconditioning Of Battery Of D.G. Set Of 12 V X 2 Of 135 Ah. , Dismantling, Repair & Reconditioning, Reinstallation, Painting With Acid Proof Paint And Re-Commissioning Of 2.1 V Cell Unit. , Break Down Maintenance Of 220 Vdc Trickle / Quick Charger Extension Panel At 11.00 Meter Vddc Room. , Break Down Works At 24 Vdc / 220 Vdc D.B. Modules At 11.00 M Vddc Room Including Attending Of Flash Over Area / Replacement Of Fuse Carriers / Switches Etc. , Break Down Maintenance Due To Fire Or Flashover On Any Portion Of The Bus Bar Of 0.4 Kv Systems Including Reassembling Of The Section And Re-Commissioning After Achieving I.R. Values. , Break Down Maintenance Of L&T/Ee/Ge Make Breakers Of 0.4 Kv System Including Replacement Of Damaged / Defective Parts. , Break Down Maintenance Of 0.4 Kv Motor Feeder Modules Including Fault Finding Of Control Circuit & Replacement Of Damaged / Defective Parts Like Contractors/ Emrs/ Switches /Fuse Carriers Etc. And Tightness Of Cable Termination At Mcc And Motor Both The End. , Break Down Maintenance Of 0.4 Kv Modules Other Than Motor Feeders Including Replacement Of Damaged/Defective Parts Like Switches/Fuse Carriers Etc. , Replacement Of Protection Relays / Bus Ct/ Bus Pt Etc. Including Rectification Of The Fault Of Associated Circuit. , Checking & Replacement Of Damaged Heaters, Its Control Circuit Parts & Re-Commissioning Of Compressors. , Break Down Maintenance Of Control Circuit Panel Of Condenser And Chiller Pumps Motors Including Fault Finding Of Control Circuit, Replacement Of Defective Parts & Set Right The Local As Well As Remote Operation. , Repair / Replacement Of Defective Switches Such As Local / Remote, Trip / Close Auto / Manual Etc. Of Bus Bar Cubicle Or Panels. , Break Down Maintenance Of Star Delta Starter & Tpn Switches Of 40 Kw To Below110 Kw Motors In Air Conditioning Plant . , Checking &Replacement Of Defective Parts Of Disconnecting Switches (Knife Switches) Such As Ferrules / Connectors / Insulators / Lugs Etc. , Daily Upkeeping Of Electrical Parts Of Central Ac Plant Comprises Of Ucb,Mcb, Service House Building, Esp Control Rooms , Round The Clock Operation & Maintenance Of Permanent Station Lighting System Of Ucb-1,2 &3, T.G. Hall Area, Boiler House Area Including I.D./F.D./P.A. Fan Area, Esp Area Including Their Control Rooms, Dg Set Room, Compressor House, Transformer Yard, Ash Water Pump House, Service House Building, M.Cc. Rooms, Switch Gear Rooms, Battery Rooms, (-4) M & (+) 5.5 M Level Cable Gallery, D.M. Plant, C.W. Pump House, Aux. Pump House, Filtration Plant, P.T. Plant, Magazine Post, Fire Pump House, Mechanical Workshop, Vehicle Base, Store Yard & Its Sheds, ‘A T.P.S. Canteen, Junior Engineers & Operators Cabins And Site Offices, Street Light, Tower Light (Excluding Those Installed In Switch Yard & In C.H.P. Areas), C.M.R. System, Loading / Unloading Site, Street Light In M.G.R. Workshop Area, Internal Telephone Exchange Pertaining To ‘A T.P.S., Anpara. , Bush Cutting/Cleaning Around The Lighting Installations Of Permanent Station Lighting System Such As L.D.B.S, J.B.S, Street Light Poles, Over Head L.T. Lines Installed At Different Locations, As Mentioned Above, Of ‘A T.P.S., Anpara. , Cutting / Trimming Of Tree Branches Around The Lighting Installations Of Permanent Station Lighting System Such As L.D.B.S, J.B.S, Street Light Poles, Over Head L.T. Lines Installed At Different Locations Of ‘A T.P.S., Anpara. , Removal Of Old Burnt / Damaged Cables & Wires Of Conduit Wiring From Conduit And Re Wiring Of Different Size Cables/ Wires In Conduit Including Re Fixing Of Conduit, Wherever It Is Hanging, At -4.0 M, 0.0 M, 3.5M And 5.5 M Elevation Of T.G Hall Area. , Removal Of Old Burnt/ Damaged Cable & Wires Of Conduit Wiring From Conduit At Different Elevation Of Boiler House/Tg Hall And Rewiring Of Different Size Cable/ Wires In Conduit As Per Site Requirement Including Re-Fixing Of Conduits Wherever It Is Hanging. , Repairing Of Ladder Associated In Lighting System , Installation Of New Light Fittings. Of Different Wattage , Installation Of New / Replacement Of Damaged Welding Branch Board/ Main Switch Carrier/Replacement Of Ldb , Installation Of New Electrical Points , Bush Cleaning In 02 M Wide Area Along The Cable Route. , Work Of Supply, Installation And Commissioning Of 8X10x4 Size Distribution Box On Street Light Poles. , Work Of Casting Of Street Light Pole Rcc Plinth. , Work Of Repairing Of Damaged Round Poles Of Streetlight. , Work Of Dismantling And Removal Of Street Light Pole. , Work Of Complete Installation Of Light Pole With Fixing Of One Number Of Hpsv/Hpmv/Led L Fitting, Distribution Box Fuse Unit And Gi Pipe Of 35 Mm. Size. , Complete Repairing/Rewinding Related Maintenance Works Of Panel Mounted Air Cooled, Dry Type,50 Kva&75Kva Isolation Lighting Transformer Installed At Various Locations In Permanent Station Lighting System. , Complete Rewinding Of Damaged / Burnt Panel Mounted Air Cooled, Dry Type, 3 Phase, 75 Kva Isolation Transformer Having Voltage Ratio 415 V / 433 V, Insulation Class ‘B, Primary Side Tapping +/- 2.5 %, Secondary Side Tapping +/- 5.0 %, Off Circuit Copper Link Type Connection. , Replacement Of Bakelite Sheet In 60 Cm X 25 Cm X 01Cm Size Having 26 Nos. Of Holes On It. , Replacement And Fixing Of Nuts & Bolts In 05Mmx05mm. Size , Servicing & Double Coat Spray Varnishing Of Panel Mounted, Air Cooled, Dry Type, 3 Phase, 75 Kva Isolation Transformer Having Voltage Ratio 415V/433 V, Insulation Class ‘B, Primary Side Tapping +/- 2.5 %, Secondary Side Tapping +/- 5.0 %, Off Circuit Copper Link Type Connection Including Minor Repairing Work Such As Brazing Of Connections, Tightening Of Nuts & Bolts Etc. And Its Re Commissioning.
Basic Detail
Tender No GEM/2026/B/7714789
Bidding Type Tender
Location
City Sonbhadra
State Uttar Pradesh
Key Dates
Publish Date 29 Jun 2026
Submission Date 27 Jul 2026
Open Date 27 Jul 2026
Finance
Tender Value 74.15 Lakhs
Tender Fee Ref. Documents
EMD 1.25 Lakhs
Exemption Not Available
Document List
e2d6d032-381f-4f33-86e3-abcc6d606192.pdf
1782460627.xlsx
1782461061.pdf
1782461090.pdf
1782461100.pdf
1782461106.pdf
1782461111.pdf
1782461116.pdf
1782461136.pdf
1782461148.pdf
1782461155.pdf
1782461163.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Jul 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
pdf

e2d6d032-381f-4f33-86e3-abcc6d606192.pdf

xlsx

1782460627.xlsx

pdf

1782461061.pdf

pdf

1782461090.pdf

pdf

1782461100.pdf

pdf

1782461106.pdf

pdf

1782461111.pdf

pdf

1782461116.pdf

pdf

1782461136.pdf

pdf

1782461148.pdf

pdf

1782461155.pdf

pdf

1782461163.pdf

Disclaimer