| 1 | Supply & Fixing 240 V, 20 A Piano Key type Plug Socket (Anchor) on sheet metal switch board incl. S & F 100 mm x 100 mm x 65 mm MS (16 SWG) switch board and bakelite/perspex top cover of 3 mm thick by brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (For AC machine) [11(a)/E-4 ,12(a)/E-4,& 15(b) / 73] |
| 2 | Supply & Fixing 240 V, 25 A Modular type starter (Make - ABB IVIE / Legrand Myrius / Schneider Livia) with 25 A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/E-19]. (For AC Machine) |
| 3 | Supplying and fixing of 415 V,8Way double door, VTPN MCB DB (Make - Legrand / Schneider / ABB Elegance) up to 250 A MCCB incomer and 63 A TP MCB outgoing with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ---- [15 / D- 11 ] |
| 4 | Supplying and fixing 415 V, 32 A per way double door 4 Way HTPN MCB DB (Make - Legrand / Schneider / ABB Elegance) with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [14 / D- 10] |
| 5 | Supplying and fixing 415 V, 250 A Four Pole MCCB of breaking capacity 25/36 kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in VTPN DB and necessary connection. (Make - Legrand / ABB / Schneider). 10 / D-8. |
| 6 | Supplying and fixing 415 V, 63 A TP MCB of Breaking capacity 10kA & C characteristics (Make - Legrand / ABB / Schneide) on din rail of VTPN DBs and necessary connection. 7 / D-6. |
| 7 | Supplying and fixing 415 V, 63 A FP MCB type Isolator (Make - Legrand / ABB / Schneider) on din rail of HTPN DB and necessary connection. [6/D-5 ] |
| 8 | Supplying and fixing 240 V, 6/10/16/20/25/32 A SP MCB of Breaking capacity 10 kA & C characteristics (Make - Legrand / ABB / Schneider) on din rail of HTPN and SPN DBs and necessary connection. Page D-6, Item No. 7. |
| 9 | Distribution wiring in 1.1 KV Gr. single core stranded 'FR' PVC insulated & unsheathed copper wire (Make - Finolex / RR Kabel / Polycab / Havells) of following sizes in 20/25 mm size MMS PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required - . 2 x 4 sq. mm + 1 x 2.5 sq. mm (for AC). [1(a -iii) / E-14] |
| 10 | 4 x 16 sq. mm + 2 x 10 sq. mm with 2 nos. PVC rigid conduit(for TPN DB) [1 (g1) / E- 9 & 7 (a) / E -16 ] |
| 11 | 4 x 25 sq. mm + 2 x 16 sq. mm with 2 nos. PVC rigid conduit(for TPN DB) [ NS ] |
| 12 | Finishing of the following PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. Page F-5, Item No. 9.2 x 4 sq. mm + 1 x 2.5 sq. mm |
| 13 | 4 x 16 sq. mm + 2 x 10 sq. mm |
| 14 | 4 x 25 sq. mm + 2 x 16 sq. mm (NS) |
| 15 | Supplying and fixing 415 V, 315 A TPN SFU with sheet steel enclosure (Make - L &T / Havells / Standard) on angle ron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [4(a)/D-3] |
| 16 | Supplying and fixing sheet steel (16SWG) cable end box on 125 A TPN SFU enclosure with nuts bolts etc incl. powder coated painting. [ 5 / D -5 ] |
| 17 | Supplying & fixing sheet metal (16 SWG) ( Dimension of sheet Metal 500 x 150 mm ) Iron Clad copper Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991 ) 415 V 200 A 85 mm long working facility for accommodation 4 x 50 X 8 x 45 mm electroliting copper bar placed in vertically with sufficient no. of drilled holes ( 8 Nos minimum) in equal distances with required sizes Gl nut bolts & double washers [ 19 ( b )/D-13 ] |
| 18 | Connecting the equipments body to earth bus bar including S&F 25 mm x 6 mm galvanised Hot Dip MS flat on wall / floor with GI Saddles / floor cutting / existing `L` hook as required and connecting to the equipments including drilled holes with bolts , nuts , washers etc. complete including mending good damages to finish as per GS [ G 3 / 5 d ] |
| 19 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground evel and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe [2a (G-1)] |
| 20 | Supply and fixing of 25 A capacity 5 pin Top with earthing attachment as per direction of EIC. |
| 21 | S&F earth bus bar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the bus bar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd. as to GS ( 4 a / G - 2) |
| 22 | S&F 40 mm x 6 mmelectroliting graded copper flat bar from 160 A TPN SFU to Busbar vwith suitable bend including drilled holes ,S& Fnuts bolts etc (NS) |
| 23 | Supply of 1.9/2 Tr. Split type Air - Conditioner Machine having following features - Cooling Capacity - 7100 Watts, Compressor - Rotary, Star Rating - 3, Power Requirements 220/240 V 50 Hz, Remote Control - Yes, Main Unit Condenser Coil - Copper, Outdoor Unit Condenser Coil - Copper, Refrigerent - R32 / R410A, Air Flow Direction - 2 Way, Modes - Cool Mode - Yes, Sleep Mode - Yes, Timer - Yes, On-Timer: Yes, Off-Timer: Yes. (Make: O-General, / Mistubishi Heavy Endustries / Mistubishi Electric/Hitachi) |
| 24 | Supply of 1.5 Tr. Split type Air - Conditioner Machine having following features - Cooling Capacity - 5300 Watts, Compressor - Rotary, EER -3.57 W/W, Star Rating - 3, Power Requirements 220/240 V 50 Hz, Remote Control - Yes, Main Unit Condenser Coil - Copper, Outdoor Unit Condenser Coil - Copper, Refrigerent - R410A / R32, Modes - Cool Mode - Yes, Sleep Mode - Yes, Timer - Yes, On-Timer: Yes, Off-Timer: Yes. (Make: O-General, / Mistubishi Heavy Endustries / Mistubishi Electric/Hitachi) |
| 25 | Supply of 1 Tr. Split type Air - Conditioner Machine having following features - Cooling Capacity - 5300 Watts, Compressor - Rotary, EER -3.57 W/W, Star Rating - 3, Power Requirements 220/240 V 50 Hz, Remote Control - Yes, Main Unit Condenser Coil - Copper, Outdoor Unit Condenser Coil - Copper, Refrigerent - R410A / R32, Modes - Cool Mode - Yes, Sleep Mode - Yes, Timer - Yes, On-Timer: Yes, Off-Timer: Yes. (Make: O-General, / Mistubishi Heavy Endustries / Mistubishi Electric/Hitachi) |
| 26 | Installation, testing and commissioning of 1.5/1.8/2.0 Tr. split AC Machine with IDU & ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut- bolt etc. & mending good the damages. |
| 27 | Supply & laying of following sizes Refrigerant Copper Pipe (Minimum thickness 0.9 mm and Make - Royku / Totaline / Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold non adhesive tape6.35 mm (1/4\\") dia incl15.88 mm (5/8\\") dia inclSupply & drawing 3 core 2.5 sq. mm. P.V.C. insulated Copper wire for connecting the Power hub to ODU. (Make - Havells / Finolex / RR Kabel) |
| 28 | Supply & laying 3/4\\" heavy type P.V.C. pipe for Water Drainage as per direction. |
| 29 | Supply and fixing of 25 A capacity 5 pin Top with earthing attachment as per direction of EIC. Please Enable Macros to View BoQ information |