| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) Kanpur Name of Work : REPAIR TO BOUNDARY WALL, DRAIN, HARDSTANDING AND OTHER REPAIR WORK IN ZONE-I AND ZONE-II OF AGE B/R-II OF GE (I) KANPUR CANTT Contract No : GE(I)/KAN/T-43 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Items/Works Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Demolition of brick work or stone/boulders masanory built in cement mortar including all quoins, arches, pillars etc, but excluding ashler facing, dressed stone work and precast concrete articals complete all as specified and directed. |
| 3 | Demolition of reinforcement cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | Demolition of cement concrete of any description and in any position complete all as specified and directed. |
| 5 | Dismantling post or strut embeded in concrete( wood/steel/RCC) any section embeded in concrete including taking out embeded portion and making good complete all as specified and directed. |
| 6 | Dismantling fencing wire mesh of any type complete all as specified and directed. |
| 7 | Dismantling structural steel work including doors, gate but excluding framed truss etc complete all as specified and directed. |
| 8 | Demolition of stone slab or tile flooring of any description or thicknes laid bedded and pointed in any mortar complete all as specified and directed. |
| 9 | Taking down cement plaster in drain, on brick or stone wall etc including racking out joint hacking for key scrubing down with water etc complete all as specified and directed. |
| 10 | M&L providing reinforced cement concrete type B1 1:2:4 (using 20 mm graded stone aggregate) in pre-cast poles, fencing post , strut for fencing avaragre sectional area exc 100 & n. exc. 250 Sqcm complete all as specified and directed. |
| 11 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6.00 mean radius built in CM 1:6 complete all as specified and directed. |
| 12 | All as per item No 10 above but except bricks complete all as specified and directed. |
| 13 | S& F 10 mm dia Ms round bars Fe-410-W (Gde E-250) quality-A or Fe 290 (Gde -E-165) as a dowel bars for insertion in cahin link fencing including cuting & fixing in position complete all as specified and directed. |
| 14 | M&L brick work with sub class 'B' bricks straight or curved on plan to any radius built in CM 1:4 in half brick thisk wall complete all as specified and directed. |
| 15 | M&L for Providing pre-cast cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cover slab & set in cement mortar 1:6 complete all as specified and directed. |
| 16 | M&L PCC 1:4:8 type D2 as in foundation concrete (using 40 mm graded stone aggregate) etc complete all as specified and directed. |
| 17 | M&L PCC 1:3:6 type C1 (Using 20 mm grded stone aggregate) as in surface channel & drain etc complete all as specified and directed. |
| 18 | M&L RCC 1:2:4 type B1 as in coping (using 20 mm graded stone aggregate) including necessary form work etc complete all as specified and directed. |
| 19 | M&L for rendering 15 mm thick on brick or concrete surfaces in CM 1:6 , finished fair & even complete all as specified and directed. |
| 20 | M&L for rendering 15 mm thick on brick or concrete surfaces in CM 1:4, finished fair & even complete all as specified and directed. |
| 21 | MS bars 10 mm dia & over (TMT Bars) cut to length bent to shape reqd including cranking binding spirally for hooping cols, hooking ends and binding with and including mild steel wire annealled not less than 0.90 mm dia or securing with clips complete all as specified and directed. |
| 22 | All as per item No 19 above but 6 to 8 mm dia complete all as specified and directed. |
| 23 | All as per item No 19 above but 5 mm dia and upto and including 10 mm dia in stirrups, spacer and binders complete all as specified and directed. |
| 24 | S&F MS work as in angle iron post & strut in fencing including cutting, notching for wire, flat iron fillets(for securing wire mesh etc including all necessary drilling, bolting or reveting etc complete all as specified and directed. |
| 25 | S&F mild steel screrw bolt 10 mm dia (Machine made) with exagonal or square heads at one end and screwed oyher, or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut n. exc 5 cm long complete all as specified and directed. |
| 26 | S&F in repairs galvanised, 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia bars at 75 mm spacing and straining and fixing to ant type of standered rail straining bolt including securing or tying at crossing with & provision of galvanised steel wire stpple or steel pins (each line to be measured) complete all as specified and directed. |
| 27 | All as per item No 25 above but restraining and securing including making good staple complete all as specified and directed. |
| 28 | S&F framed work as in steel /wicket gates with angle or other section with gusset plate Fe-410-W(Gde-E-250) quality-B including welding & errection in position complete all as specified and directed. |
| 29 | M&L for granite (of any type) 18 to 20 mm thick machine cut,beded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting & polishing incl moulding complete all as specified and directed. |
| 30 | M&L for RCC 1:11/2:3 type B1 (Using 20 mm graded stone aggregate) as in pillars, column pier post & footing complete all as specified and directed. |
| 31 | Use & waste of form work to RCC column, footing etc for flat rough finished surfaces complete all as specified and directed. |
| 32 | M&L for rendering 10 mm thick in CM 1:4 for receiving tiling in vertical surfaces as in dado/skirting complete all as specified and directed. |
| 33 | Excavation in post holes (or similar holes ) each n. exc. 0.50 cum getting out , returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance n. exc 50 mtr and making good surfaces complete all as specified and directed. |
| 34 | Excavation in trenches n. exc 1.50 m seep & 1.50 mtr wide & getting out in soft/loose soil complete all as specified and directed. |
| 35 | Returning filling in including spreading levelling, watering & well ramming in layers not exc 25 CM complete all as specified and directed. |
| 36 | Removing excavated material n. exc. 50 mtr & depositing where directed at a level n. exc. 1.50 mtr above the starting point complete all as specified and directed. |
| 37 | M&L for preparation of new steel or iron surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat zinc chrome red oxide primer complete all as specified and directed. |
| 38 | Preparation of newly plastered surfaces of wall and applying two coats cement base paint incl Priming plastered and other surfaces complete all as specified and directed. |
| 39 | S&F MS galvanised chain link fencing 3.40 mm dia & 100x100 mesh including line wires wt n. exc 4.00 Kg/Sqm complete all as specified and directed. |
| 40 | M&L for PCC 1 : 2 : 4 type B1 (20mm stone agg graded) finished even and smooth with out using extra cement including spike rolling to surfaces of making impressions of expanded metal whilest the concrete in green including filling of panel joint with bitumen and sand mixed (1:3) and necessary formworks complete, thickness of PCC 100 mm complete all as specified and directed. |
| 41 | M&L for Chequered tiles of size 300x300x20 mm thick over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 42 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment complete all as specified and directed. |
| 43 | M&L for sand filling under floor or in foundation including watering and in consolidation complete all as specified. |
| 44 | S&F Punched tape concentrina coil of dia of coil 450mm conforming to IS specifications, each coil to be stretched to 6.00 metre length(50 rounds) , secured and fixed in position having minimum tensile strength of 1620 N/ Sqmm of specing steel core wire of size 2.60mm, complete all as specified and directed. Make of Concertina coil shall be as approved by GE. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |