| Sl. No. | Item Title | Item Description |
| 1 | Replace the worn-out runners of the cane carrier, bagasse carrier, and bagasse elevator. | Replace the worn-out runners of the cane carrier, bagasse carrier, and bagasse elevator. |
| 2 | Remove the angles fitted on both sides of the cane carrier and install new angles | Remove the angles fitted on both sides of the cane carrier and install new angles |
| 3 | Remove, straighten, and refit the bent girders of the cane carrier pit and conduct a successful trial. | Remove, straighten, and refit the bent girders of the cane carrier pit and conduct a successful trial. |
| 4 | Cut out and remove the damaged side plate of the cane carrier and replace it with a new/reconditioned plate. | Cut out and remove the damaged side plate of the cane carrier and replace it with a new/reconditioned plate. |
| 5 | Repair the mill house gutter. | Repair the mill house gutter. |
| 6 | Repair the damaged bottom and side plates of the juice/water weighing tank and conduct a trial. | Repair the damaged bottom and side plates of the juice/water weighing tank and conduct a trial. |
| 7 | Cut out and replace the damaged trough plates of the bagasse elevator/bagasse carrier. | Cut out and replace the damaged trough plates of the bagasse elevator/bagasse carrier. |
| 8 | Replace the damaged side plates and trough plates of the bagasse elevator/bagasse carrier and conduct a trial. | Replace the damaged side plates and trough plates of the bagasse elevator/bagasse carrier and conduct a trial. |
| 9 | Remove the catcher of the quad, repair/replace the damaged fins, fit and strengthen them, and conduct a satisfactory trial. | Remove the catcher of the quad, repair/replace the damaged fins, fit and strengthen them, and conduct a satisfactory trial. |
| 10 | Install new tubes in the quad and juice heater and carry out hydraulic testing. | Install new tubes in the quad and juice heater and carry out hydraulic testing. |
| 11 | Conduct hydraulic testing of the tubes of the quad, juice heater, and pans and give a satisfactory trial | Conduct hydraulic testing of the tubes of the quad, juice heater, and pans and give a satisfactory trial |
| 12 | Remove the quad seal box and related vapor pipe cover, fabricate a new seal box from 10/12 mm plate, refit all parts, and conduct a successful trial | Remove the quad seal box and related vapor pipe cover, fabricate a new seal box from 10/12 mm plate, refit all parts, and conduct a successful trial |
| 13 | Fabricate and install a new catcher for the quad and conduct a trial. | Fabricate and install a new catcher for the quad and conduct a trial. |
| 14 | Remove the rods of the quad blind tubes and ream the holes. | Remove the rods of the quad blind tubes and ream the holes. |
| 15 | Replace the damaged compartment plate of the juice heater and conduct a trial. | Replace the damaged compartment plate of the juice heater and conduct a trial. |
| 16 | Open, face, and refit the juice heater cover. | Open, face, and refit the juice heater cover. |
| 17 | Replace the damaged partition plate of the juice heater with a new 8/10 mm plate, prepare packing grooves, fit packing, and conduct a trial. | Replace the damaged partition plate of the juice heater with a new 8/10 mm plate, prepare packing grooves, fit packing, and conduct a trial. |
| 18 | Open the damaged junction box of the juice heater, replace the double-beat valves with new ones, and conduct a satisfactory trial. | Open the damaged junction box of the juice heater, replace the double-beat valves with new ones, and conduct a satisfactory trial. |
| 19 | Patch repair the damaged partition plate of the juice heater. | Patch repair the damaged partition plate of the juice heater. |
| 20 | Remove the old juice heater and install another/new juice heater at the specified location with all connections and conduct a satisfactory trial. | Remove the old juice heater and install another/new juice heater at the specified location with all connections and conduct a satisfactory trial. |
| 21 | Cut out about one meter of the recovery tower flange side of the syrup sulphiter and replace it with a new section, fit it, and conduct a trial. | Cut out about one meter of the recovery tower flange side of the syrup sulphiter and replace it with a new section, fit it, and conduct a trial. |
| 22 | Replace the damaged pipe flange of the MS/SS coil of the juice sulphiter | Replace the damaged pipe flange of the MS/SS coil of the juice sulphiter |
| 23 | Remove and replace the jacket of the sulphur furnace using a new/reconditioned plate | Remove and replace the jacket of the sulphur furnace using a new/reconditioned plate |
| 24 | Remove and replace the damaged top cover of the sulphur furnace and conduct a trial. | Remove and replace the damaged top cover of the sulphur furnace and conduct a trial. |
| 25 | Remove and replace the damaged bottom tray of the sulphur furnace and conduct a trial | Remove and replace the damaged bottom tray of the sulphur furnace and conduct a trial |
| 26 | Remove and replace the damaged tray of the vacuum filter. | Remove and replace the damaged tray of the vacuum filter. |
| 27 | Remove the damaged plate near the juice box from the upper cell door and replace it with a new 8/10 mm plate; conduct a satisfactory trial. | Remove the damaged plate near the juice box from the upper cell door and replace it with a new 8/10 mm plate; conduct a satisfactory trial. |
| 28 | Repair the damaged disc/tray fitted on the center shaft in the mud compartment of the door. | Repair the damaged disc/tray fitted on the center shaft in the mud compartment of the door. |
| 29 | Repair the trays of the compartment wherever leakage/cuts have occurred. | Repair the trays of the compartment wherever leakage/cuts have occurred. |
| 30 | Check the plate compartments, replace damaged plates, provide angle support, label them, and conduct a leak-proof trial. | Check the plate compartments, replace damaged plates, provide angle support, label them, and conduct a leak-proof trial. |
| 31 | Replace the door gutter. | Replace the door gutter. |
| 32 | Cut out and replace the damaged shell of the pan using 8/10 mm plates and conduct a satisfactory trial. | Cut out and replace the damaged shell of the pan using 8/10 mm plates and conduct a satisfactory trial. |
| 33 | Remove the damaged feed header of the pans, fabricate and install a new header with flange, complete all related work, and conduct a trial. | Remove the damaged feed header of the pans, fabricate and install a new header with flange, complete all related work, and conduct a trial. |
| 34 | Replace the damaged bottom/side plates of the hot-cold water overhead tank and conduct a leak-proof trial. | Replace the damaged bottom/side plates of the hot-cold water overhead tank and conduct a leak-proof trial. |
| 35 | Remove the pan top cover seal and replace the taper cone beneath it using 10 mm plate. | Remove the pan top cover seal and replace the taper cone beneath it using 10 mm plate. |
| 36 | Remove and replace the pan top cover and conduct a trial. | Remove and replace the pan top cover and conduct a trial. |
| 37 | Fabricate and install the syrup tank gutter of the pan and conduct a satisfactory trial. | Fabricate and install the syrup tank gutter of the pan and conduct a satisfactory trial. |
| 38 | Remove and replace the pan dome with a new plate and conduct a satisfactory trial. | Remove and replace the pan dome with a new plate and conduct a satisfactory trial. |
| 39 | Remove the broken shaft of the crystallizer and install a new shaft. | Remove the broken shaft of the crystallizer and install a new shaft. |
| 40 | Replace the worn ribs fitted on the arms of the crystallizer and strengthen them | Replace the worn ribs fitted on the arms of the crystallizer and strengthen them |
| 41 | Remove damaged crystallizer arms and fabricate/install new ones. | Remove damaged crystallizer arms and fabricate/install new ones. |
| 42 | Fabricate and install the molasses chamber of the centrifugal machine and conduct a successful trial. | Fabricate and install the molasses chamber of the centrifugal machine and conduct a successful trial. |
| 43 | Fabricate and install the chute of the continuous centrifugal machine and conduct a successful trial. | Fabricate and install the chute of the continuous centrifugal machine and conduct a successful trial. |
| 44 | Remove the old magma shaft, fabricate a new one, install it, and conduct a trial. | Remove the old magma shaft, fabricate a new one, install it, and conduct a trial. |
| 45 | Dismantle the transit heater fitted on centrifugal machine No. 1, replace all damaged partition plates, nipples, and other parts, reassemble, and conduct a trial. | Dismantle the transit heater fitted on centrifugal machine No. 1, replace all damaged partition plates, nipples, and other parts, reassemble, and conduct a trial. |
| 46 | Open, repair, and refit the old strainer mesh of the pump suction pipe. | Open, repair, and refit the old strainer mesh of the pump suction pipe. |
| 47 | Remove, fabricate, inspect, and reinstall the jet boxes fitted in the condensers. | Remove, fabricate, inspect, and reinstall the jet boxes fitted in the condensers. |
| 48 | Open the junction box in the spray pond, clean the nozzles and pipelines, clean branch line debris, and refit all parts. | Open the junction box in the spray pond, clean the nozzles and pipelines, clean branch line debris, and refit all parts. |
| 49 | Fabricate and fit the cluster using MS pipe in the spray pond. | Fabricate and fit the cluster using MS pipe in the spray pond. |
| 50 | Carry out patch repairs on damaged and weak plates at various stations. | Carry out patch repairs on damaged and weak plates at various stations. |
| 51 | Fabricate and install circular/square tanks at any location in the mill as directed, provide connections, and conduct a trial. | Fabricate and install circular/square tanks at any location in the mill as directed, provide connections, and conduct a trial. |
| 52 | Remove old beds of pumps and motors of various sizes at different stations and fabricate/install new beds. | Remove old beds of pumps and motors of various sizes at different stations and fabricate/install new beds. |
| 53 | Repair the bagasse flow cyclone fitted on the vacuum filter, fabricate and install a new chimney, and conduct a satisfactory trial. | Repair the bagasse flow cyclone fitted on the vacuum filter, fabricate and install a new chimney, and conduct a satisfactory trial. |
| 54 | Remove the cone fitted on top of the juice sulphiter and fabricate/install a new one from 8/10 mm plate as per sample. | Remove the cone fitted on top of the juice sulphiter and fabricate/install a new one from 8/10 mm plate as per sample. |
| 55 | Replace the shell of the clarifier compartment and conduct a trial. | Replace the shell of the clarifier compartment and conduct a trial. |
| 56 | Remove and replace the vapor pipe and intermediate vapor pipe of Quad Body No. 04 using 8/10 mm plate and conduct a trial. | Remove and replace the vapor pipe and intermediate vapor pipe of Quad Body No. 04 using 8/10 mm plate and conduct a trial. |
| 57 | Remove the vapor bleeding pipe from Quad Body No. 01 to the juice heater header and fabricate/install a new one using 8/10 mm plate; conduct a trial. | Remove the vapor bleeding pipe from Quad Body No. 01 to the juice heater header and fabricate/install a new one using 8/10 mm plate; conduct a trial. |
| 58 | Dismantling, fabrication, and erection of heavy structures. | Dismantling, fabrication, and erection of heavy structures. |
| 59 | Strengthening of heavy structures. | Strengthening of heavy structures. |
| 60 | Carrying out patching work at various stations. | Carrying out patching work at various stations. |
| 61 | Remove SS/brass tubes of pans, juice heaters, or quads and carry out retubing with new tubes followed by satisfactory hydraulic testing. | Remove SS/brass tubes of pans, juice heaters, or quads and carry out retubing with new tubes followed by satisfactory hydraulic testing. |
| 62 | Fabricate motor beds for motors ranging from 10 HP to 20 HP. | Fabricate motor beds for motors ranging from 10 HP to 20 HP. |
| 63 | Fabricate and connect the magma pump motor bed. | Fabricate and connect the magma pump motor bed. |
| 64 | Fabricate economizer tubes as per the sample tube provided and conduct hydraulic testing and trial. | Fabricate economizer tubes as per the sample tube provided and conduct hydraulic testing and trial. |
| 65 | Remove the ducting of the air heater/economizer and fabricate new ducting using new plates. | Remove the ducting of the air heater/economizer and fabricate new ducting using new plates. |
| 66 | Dismantle equipment from the existing centrifugal installation to create space for a centrifugal machine received from Majhola Sugar Mill; fabricate columns, beams, base, and platform; install the complete machine, motor, panel, staging, and accessories; and conduct a satisfactory trial. | Dismantle equipment from the existing centrifugal installation to create space for a centrifugal machine received from Majhola Sugar Mill; fabricate columns, beams, base, and platform; install the complete machine, motor, panel, staging, and accessories; and conduct a satisfactory trial. |
| 67 | Fabricate and install the hopper base channel, level it, assemble the drive, fabricate the motor bed, and carry out alignment. | Fabricate and install the hopper base channel, level it, assemble the drive, fabricate the motor bed, and carry out alignment. |
| 68 | Fabricate the hopper trough, fit distance pieces and connecting rods, and conduct a satisfactory trial. | Fabricate the hopper trough, fit distance pieces and connecting rods, and conduct a satisfactory trial. |
| 69 | Fabricate the pug mill column structure and platform, install the pug mill, prepare motor and reduction gear beds, align them, and conduct a satisfactory trial. | Fabricate the pug mill column structure and platform, install the pug mill, prepare motor and reduction gear beds, align them, and conduct a satisfactory trial. |
| 70 | Remove the tubes of the air heater, fabricate/install replacements using old tubes where applicable, and conduct a satisfactory trial. | Remove the tubes of the air heater, fabricate/install replacements using old tubes where applicable, and conduct a satisfactory trial. |
| 71 | Cutting serration grooves in the teeth of the mill rollers as per the specifications/instructions. | Cutting serration grooves in the teeth of the mill rollers as per the specifications/instructions. |
| 72 | Dismantling of pipe lines from 300 mm to 1100 mm dia. (Pan, Vapor Pipe, Injection and Spray Header). | Dismantling of pipe lines from 300 mm to 1100 mm dia. (Pan, Vapor Pipe, Injection and Spray Header). |
| 73 | Fabrication of pipe lines from 300 mm to 1100 mm dia. (Pan, Vapor Pipe, Injection and Spray Header). | Fabrication of pipe lines from 300 mm to 1100 mm dia. (Pan, Vapor Pipe, Injection and Spray Header). |
| 74 | Erection/installation of pipe lines from 300 mm to 1100 mm dia. (Pan, Vapor Pipe, Injection and Spray Header). | Erection/installation of pipe lines from 300 mm to 1100 mm dia. (Pan, Vapor Pipe, Injection and Spray Header). |
| 75 | Dismantling of damaged 2-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Dismantling of damaged 2-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 76 | Dismantling of damaged 3-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Dismantling of damaged 3-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 77 | Dismantling of damaged 4-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Dismantling of damaged 4-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 78 | Dismantling of damaged 5-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Dismantling of damaged 5-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 79 | Dismantling of damaged 6-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Dismantling of damaged 6-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 80 | Dismantling of damaged 8-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Dismantling of damaged 8-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 81 | Dismantling of damaged 10-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Dismantling of damaged 10-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 82 | Dismantling of damaged 12-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Dismantling of damaged 12-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 83 | Erection/installation and trial of new/old 2-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Erection/installation and trial of new/old 2-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 84 | Erection/installation and trial of new/old 3-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Erection/installation and trial of new/old 3-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 85 | Erection/installation and trial of new/old 4-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Erection/installation and trial of new/old 4-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 86 | Erection/installation and trial of new/old 5-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Erection/installation and trial of new/old 5-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 87 | Erection/installation and trial of new/old 6-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Erection/installation and trial of new/old 6-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 88 | Erection/installation and trial of new/old 8-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Erection/installation and trial of new/old 8-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 89 | Erection/installation and trial of new/old 10-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Erection/installation and trial of new/old 10-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 90 | Erection/installation and trial of new/old 12-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). | Erection/installation and trial of new/old 12-inch pipeline (pipe sizes ranging from ½ inch to 12 inch). |
| 91 | Dismantling and re-installation of damaged 2-inch Bend at various stations (including tees, crosses, bends, reducers, nipples, flanges and valves ranging from 25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 2-inch Bend at various stations (including tees, crosses, bends, reducers, nipples, flanges and valves ranging from 25 mm to 300 mm dia.). |
| 92 | Dismantling and re-installation of damaged 3-inch Bend at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 3-inch Bend at various stations (25 mm to 300 mm dia.). |
| 93 | Dismantling and re-installation of damaged 4-inch Bend at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 4-inch Bend at various stations (25 mm to 300 mm dia.). |
| 94 | Dismantling and re-installation of damaged 5-inch Bend at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 5-inch Bend at various stations (25 mm to 300 mm dia.). |
| 95 | Dismantling and re-installation of damaged 6-inch Bend at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 6-inch Bend at various stations (25 mm to 300 mm dia.). |
| 96 | Dismantling and re-installation of damaged 8-inch Bend at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 8-inch Bend at various stations (25 mm to 300 mm dia.). |
| 97 | Dismantling and re-installation of damaged 10-inch Bend at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 10-inch Bend at various stations (25 mm to 300 mm dia.). |
| 98 | Dismantling and re-installation of damaged 2-inch Flange at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 2-inch Flange at various stations (25 mm to 300 mm dia.). |
| 99 | Dismantling and re-installation of damaged 3-inch Flange at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 3-inch Flange at various stations (25 mm to 300 mm dia.). |
| 100 | Dismantling and re-installation of damaged 4-inch Flange at various stations (25 mm to 300 mm dia.). | Dismantling and re-installation of damaged 4-inch Flange at various stations (25 mm to 300 mm dia.). |
| 101 | Dismantling and re-installation of damaged/corroded flanges (5-inch size) at various stations, including tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm diameter. | Dismantling and re-installation of damaged/corroded flanges (5-inch size) at various stations, including tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm diameter. |
| 102 | At various stations, dismantling and installing corroded/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch flange. | At various stations, dismantling and installing corroded/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch flange. |
| 103 | At various stations, dismantling and installing corroded/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch flange | At various stations, dismantling and installing corroded/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch flange |
| 104 | At various stations, dismantling and installing corroded/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 1-inch flange | At various stations, dismantling and installing corroded/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 1-inch flange |
| 105 | At various stations, dismantling and installing corroded/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch flange | At various stations, dismantling and installing corroded/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch flange |
| 106 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch reducer. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch reducer. |
| 107 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch reducer. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch reducer. |
| 108 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch reducer. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch reducer. |
| 109 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch reducer. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch reducer. |
| 110 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch reducer. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch reducer. |
| 111 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch reducer. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch reducer. |
| 112 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch reducer. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch reducer. |
| 113 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 2-inch valve. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 2-inch valve. |
| 114 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch valve. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch valve. |
| 115 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch valve. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch valve. |
| 116 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch valve. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch valve. |
| 117 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch valve. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch valve. |
| 118 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch valve. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch valve. |
| 119 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch valve. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch valve. |
| 120 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch valve. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch valve. |
| 121 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 2-inch nipple. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 2-inch nipple. |
| 122 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch nipple. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch nipple. |
| 123 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch nipple. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch nipple. |
| 124 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch nipple. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch nipple. |
| 125 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch nipple. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch nipple. |
| 126 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch nipple. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch nipple. |
| 127 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch nipple. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch nipple. |
| 128 | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 2-inch nipple. | At various stations, dismantling and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 2-inch nipple. |
| 129 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 2-inch bend | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 2-inch bend |
| 130 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch bend | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch bend |
| 131 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch bend | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch bend |
| 132 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch bend | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch bend |
| 133 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch bend | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch bend |
| 134 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch bend | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch bend |
| 135 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch bend | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch bend |
| 136 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch flange. | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch flange. |
| 137 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch flange. | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 3-inch flange. |
| 138 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch flange. | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 4-inch flange. |
| 139 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch flange. | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 5-inch flange. |
| 140 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch flange. | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 6-inch flange. |
| 141 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch flange. | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 8-inch flange. |
| 142 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch flange. | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 10-inch flange. |
| 143 | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch flange. | At various stations, fabricating and installing worn-out/damaged tees, crosses, bends, reducers, nipples, flanges, and valves ranging from 25 mm to 300 mm size, including 12-inch flange. |
| 144 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 3-inch reducer. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 3-inch reducer. |
| 145 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 4-inch reducer. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 4-inch reducer. |
| 146 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 5-inch reducer. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 5-inch reducer. |
| 147 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 6-inch reducer. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 6-inch reducer. |
| 148 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 8-inch reducer. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 8-inch reducer. |
| 149 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 10-inch reducer. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 10-inch reducer. |
| 150 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 12-inch reducer. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 12-inch reducer. |
| 151 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 2-inch valve. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 2-inch valve. |
| 152 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 3-inch valve. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 3-inch valve. |
| 153 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 4-inch valve. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 4-inch valve. |
| 154 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 5-inch valve. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 5-inch valve. |
| 155 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 6-inch valve. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 6-inch valve. |
| 156 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 8-inch valve. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 8-inch valve. |
| 157 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 10-inch valve. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 10-inch valve. |
| 158 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 12-inch valve. | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 12-inch valve. |
| 159 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 2-inch nipple | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 2-inch nipple |
| 160 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 3-inch nipple | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 3-inch nipple |
| 161 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 4-inch nipple | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 4-inch nipple |
| 162 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 5-inch nipple | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 5-inch nipple |
| 163 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 6-inch nipple | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 6-inch nipple |
| 164 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 8-inch nipple | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 8-inch nipple |
| 165 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 10-inch nipple | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 10-inch nipple |
| 166 | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 12-inch nipple | Fabrication and installation of damaged/worn-out Tee, Cross, Bend, Reducer, Nipple, Flange, and Valve of sizes ranging from 25 mm to 300 mm at various stations, including a 12-inch nipple |
| 167 | Fabrication and installation of flanges of sizes above 300 mm and up to 1100 mm, including a 14-inch flange | Fabrication and installation of flanges of sizes above 300 mm and up to 1100 mm, including a 14-inch flange |
| 168 | Fabrication and installation of flanges of sizes above 300 mm and up to 1100 mm, including a 16-inch flange | Fabrication and installation of flanges of sizes above 300 mm and up to 1100 mm, including a 16-inch flange |
| 169 | Fabrication and installation of flanges of sizes above 300 mm and up to 1100 mm, including a 20-inch flange | Fabrication and installation of flanges of sizes above 300 mm and up to 1100 mm, including a 20-inch flange |
| 170 | Fabrication and installation of flanges of sizes above 300 mm and up to 1100 mm, including a 44-inch flange | Fabrication and installation of flanges of sizes above 300 mm and up to 1100 mm, including a 44-inch flange |
| 171 | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 14-inch reducer. | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 14-inch reducer. |
| 172 | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 16-inch reducer. | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 16-inch reducer. |
| 173 | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 18-inch reducer. | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 18-inch reducer. |
| 174 | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 20-inch reducer. | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 20-inch reducer. |
| 175 | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 36-inch reducer. | Fabrication and erection (installation) of reducers of sizes above 300 mm and up to 1100 mm, including a 36-inch reducer. |
| 176 | Fabrication and erection (installation) of bends and tees of sizes above 300 mm and up to 1100 mm, including 14-inch bends – 2 Nos. | Fabrication and erection (installation) of bends and tees of sizes above 300 mm and up to 1100 mm, including 14-inch bends – 2 Nos. |
| 177 | Fabrication and erection (installation) of bends and tees of sizes above 300 mm and up to 1100 mm, including 20-inch bends – 5 Nos. | Fabrication and erection (installation) of bends and tees of sizes above 300 mm and up to 1100 mm, including 20-inch bends – 5 Nos. |
| 178 | Fabrication and erection (installation) of bends and tees of sizes above 300 mm and up to 1100 mm, including 36-inch bends – 8 Nos. | Fabrication and erection (installation) of bends and tees of sizes above 300 mm and up to 1100 mm, including 36-inch bends – 8 Nos. |
| 179 | Fabrication and erection (installation) of bends and tees of sizes above 300 mm and up to 1100 mm, including 14-inch Nipil – 2 Nos. | Fabrication and erection (installation) of bends and tees of sizes above 300 mm and up to 1100 mm, including 14-inch Nipil – 2 Nos. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail