| 1 | S & F of modular switch one way 10 amp,1 module, make -Cona/Legrand/ C&S/Havells/ Anchor or equivalent. |
| 2 | S & F of modular switch one way 16 amp,1 module, make -Cona/Legrand/C&S/Havells/ Anchor or equivalent. |
| 3 | S & F of modular socket , 2/3 or combine 2 & 3 pin, 6 amp . make -Cona/Legrand/C&S/ Havells/ Anchor or equivalent.. (As per directed by EIC) |
| 4 | S & F Switch piano flush button single pole one way 5 Amp, Anchor /CONA/Havells/ Legrand or equivalent make. |
| 5 | S & F Switch socket combination 2 in 1 ,3 Pin, 5 and 15 Amp flush type universal, Anchor /Cona/Havells/ Legrand or equivalent make |
| 6 | S & F of Fixing back with due repair PVC /Poly carbonate type Angle / pendent type Lamp holder . Anchor /CONA/Havells/ Legrand or equivalent make. |
| 7 | S & F celing rose,2/3 point/PVC/ Polycarbonate ,isolated body.Anchor /CONA /Havells/ Legrand Make or equivalent make |
| 8 | Fixing of repaired ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan. |
| 9 | Fixing of Exhaust Fan and connecting up including provision of cable from ceiling rose or connector to fan |
| 10 | S & F in repairs to Air termination ,single point aluminium rod 12 mm Dia,300 mm Long |
| 11 | S & F in repairs to Aluminium strip 25 X 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground for Lightning conductors. |
| 12 | S & F only Earth continuity conductor,25 X4 mm G.I strip on wall /recess/chases/buried in ground/drawn in conduit or pipe etc as directed by EIC. |
| 13 | Taking down carefully copper/aluminium point wiring (light,fan, socket or power) complete, ( fittings such as switches,ceiling roses,pendants,regulators, sockets etc to be measured separaetly ) removing materials to store for keeping in safe custody for re-use at site and making good disturbed surfaces of walls ,floors etc. |
| 14 | Taking down carefully by unscrewing from boards/out-let boxes ,fittings and fixtures such as switches,sockets,ceiling roses,lamp holders,brakets,ceiling fittings,bulk head fittings, tube light fittings and regulators etc. for re-use at site or carrying to the store ( to be measured only when found serciable in all respects complete for re-use) |
| 15 | M&L point wiring for one light point or one fan point controlled by one switch with 2.5 sq mm copper conductor,660 V, FR PVC insulated cable Polycab/Finolex/HPL/V-Gaurd or equivalent make in PVC conduit with 1.5 sq.mm copper FR PVC insulated earth conductor & accessories. |
| 16 | M&L point wiring for one light point or one fan point controlled by one switch with 1.5 sq mm copper conductor,660 V, FR PVC insulated cable, Polycab/Finolex/HPL/V-Gaurd or equivalent make in PVC conduit with 1.0 sq.mm copper FR PVC insulated earth conductor & accessories. |
| 17 | M & L for wiring for circuit/submain wiring alongwith earthwire with the 2 X 1.5 sq.mm+1X1.0 sq.mm earth wire of FR PVC insulated copper conductor,Polycab /Finolex/ HPL/V-Gaurd or equivalent make, single core cable in surface/recessed and in steel conduit. |
| 18 | M & L for wiring for circuit/submain wiring alongwith earthwire with the 2 * 2.5 sq.mm+1*1.5 sq.mm earth wire of FR PVC insulated copper conductor, Polycab/ Finolex/ HPL/V-Gaurd or equivalent make,single core cable in surface/recessed and in steel conduit. |
| 19 | M & L for earthing complete with using earth plate electrode 60x60 cm x6 mm thick ,buried directly in ground ( earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised strip 32x6 mm as earthing lead by means of bolts,nuts,ckeck nuts and washers of galvanised iron or steel including upto 7.5 mtr length/test point as per IS:3043/1987 and SSR-2020 Plate no.3 & indicated including testing on completion and as directed by EIC |
| 20 | Excavation in hard dense soil 1.5 mtr wide & 2.5 mtr deep for earth pits |
| 21 | Supply & fixing of G,I Pipe medium grade 25 mm Dia with GI nuts & bolts ,2 nos of clamp ,funnel etc as watering pipe in earth pits. |
| 22 | Material and labour for PCC of 1:2 : 4 of type B -2 Using 40mm graded aggregate for making foundation of LP finilal/steel tubelar swaged pole . |
| 23 | demolition /dismantelling cement concrete in ground floors and pavings n exc 15 cm thickness |
| 24 | Painting of steel & Iron surfaces ( Electrical apparatus like Street Light DBs, HT/ LT Panels,Feeder Pillars ,Transformers etc. ), one coat of synthetic enamel light grey /smoke grey /siemens grey colour . ( Whenever required painting shall be done through applying Suitable Painting Brush /Spray painting or as directed by EIC.) |
| 25 | Rough excavation intrenches not exceeding 1.5 wide and not exceeding 1.5 m in depth in hard dense soil and getting out for laying of cable |
| 26 | back filling of excavation soil spreading, leveling & well raming in layers. |
| 27 | M & L for sand filling in cable trench. |
| 28 | Supplying and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 x 150x 40mm. |
| 29 | supply and fixing of GI pipe medium grade 80 mm dia under road / culvert etc. |
| 30 | M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel section inclding barass or stainless steel nut,bolt,washer,welding,bending cold or hot,drilling holes with drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, oneunder coat and one finishing coat ofpaint(as directed by EIC/SIC). |
| 31 | Supply & Fixing 12 mtr long steel tubelar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-64 with painting and as per directed by EIC. |
| 32 | M& L for stay assembly comlete with accessories as shown in electrical plate no.1 (loop type insulator,stay clamps, excavation and concreate measured separately ), diameter of stay rod is 20mm. |
| 33 | M&L for loop type insulator, vitreous porcelain, white, brown or green large size, with overall dimensions 90mm x 140 mm, clearance of hole 25.5mm |
| 34 | M& L for stay wire, galvanised stay strand ( grade 2) size 7/4mm |
| 35 | Supply & Fixing 9 mtr long steel tubelar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 with painting and as per directed by EIC. |
| 36 | supplying and fixing 1100 volt grade heavy duty cable PVCinsulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire one twin core cable flat or circular of 4 sqmm solid alluminum conductor |
| 37 | S & F of modular socket , multipurpose ,6/16A amp ,2/3 pin combined 2 modul, make -Cona/ Legrand/ C&S/ Havells/ Anchor or equivalent. |
| 38 | M&L for plate, plane or chequrred ,Fe 410-W (Gde-E- 250 ) quality-A, not less than 10mm channels square cut or notch ordinary and counter sunk forming holes 18mm and with proper continuos seam welding(as directed by EIC/SIC). |
| 39 | Fixing back in due repairs to Switch unit/ Switch fuse unit (DP/TPN fused and neutral link), any voltage, any Amp. |
| 40 | Fixing back with due repairs Replacement of Bulb/CFL/T-5/LED lamp, LED Tube light only ( Materials will be provided by Factory) |
| 41 | Repairing & fixing back of Flamepoof & weatherproof rotary type switch/switch socket combination,16A, 250V , double pole of any make or as directed by EIC. ( Material will be provided by OFBa) |
| 42 | Fixing only Flameproof junction boxes up to 100/120 mm dia, 2/4 way ( Material will be provided by OFBA) |
| 43 | Repairing /replacement of LED/CFL lamps of FLP/WP well glass/bulk head fittings or as directed by EIC ( Material Will be provided by OFBa) |
| 44 | Repairing of FLP/WP tube light fitting by replacing LED tube provided by O.F.Bhandara at various locations as directed by EIC. |
| 45 | Removing & Fixing back with due repairs HPSV/HPMV/MH/FTL/LED Street light fitting/SEARCH LIGHT of any rating including replacement of LED panel , Driver etc of any wattage rating .( Materials will be provided by O.F.Bhandara) |
| 46 | Taking down tube light fitting, FLP (1 x 40 W) for repairing. |
| 47 | Fixing back FTL tube light fitting, FLP (1x 40 W) by replacing tube, electronic choke rotor holder, etc. |
| 48 | Fixing only well glass LED light fitting 1x35W ,FLP-WP as per directed by EIC /site incharge. |
| 49 | M & L for sheet metal enclosure DB for MCBs SPN 2 way, single phase and neutral. HPL/Havells / L& T or its equivalent |
| 50 | M & L for sheet metal enclosure DB for MCBs 4 way,415V, 200A bus bar,Tripple pole and neutral, Double door.HPL/Havells / L & T or its equivalent. |
| 51 | supply & Fixing outdoor type distribution box made out of CRCA sheet metal 2mm thick on pole 415 V consisting of 1 nos. of 63 A connector and one no. of 6 A MCB SPN with bottom cable plate drilled, danger sticker 415 V and fixed with rubber gourments. the DB cover will have lockable arrangements. The DB should and connection of street light distribution box,CRCA sheet metal 2mm thick, on pole;size-300x300x150 mm, 2 Nos. of GI clamp of 25 X 5mm dully painted to be provided to fixed the DB on pole. |
| 52 | Fixing only straight through heat shrinkable cable jointing kit suitable for 95 sq.mm to 400 sq.mm XLPE LT cable 3.5 core. Make REPL/Raychem RPG/3-Mor equivalent. |
| 53 | Shifting & Laying in cable trench / fixing by means G.I Saddle of LT Cables Sizes from 1.5 Sq.mm to 25 Sq.mm ( Cable will be provided by O.F.Bhandara). |
| 54 | Shifting & Laying in cable trench / fixing by means G.I Saddle of LT Cables Sizes from 35 Sq.mm to 400 Sq.mm ( Cable will be provided by O.F.Bhandara). |
| 55 | Maintenance and testing of LT Air Circuit Breakers in sub-stations (Range 630A to 4000 A). |
| 56 | S & F of open type PVC Modular plate with PVC surface frame 12 module make - Cona/ Legrad/C&S/Havells/ Anchor or equivailent ( as per directed by EIC) |
| 57 | S & F of open type PVC Modular plate with PVC surface frame 8 module make - Cona/ Legrad/C&S/Havells/ Anchor or equivailent ( as per directed by EIC) |
| 58 | S & F of G.I pipe medium grade 25 mm dia with GI nuts & bolts, 2 nos clamp and 1.5 mtr, bent to shape as per required for bracket of street light /perimeter light ( as per directed by EIC) |
| 59 | S & F of FRP / DMC conical insulator M12*60 HT, rated volt 440 V, test volt 2 KV for 1 min, size base diameter 60 mm, height not less than 60 mm from base, top face diameter not less than 40 mm effective threaded length not less than 16 to 19 mm with brass /stainless steel nut, bolt & washer.( fixing of insulator as directed by EIC) |
| 60 | repairing /replacement of existing Air termination ,single point aluminium rod 12 mm Dia,1.5 m Long ( materials will be provided by factory)) |
| 61 | Supply & Fixing of separator / Insulator for LP strip , Power earthing strip as per directed by EIC |
| 62 | Supply & fixing of 3 core 1.5 sq. mm flexible multistrand cable ( as per directed by EIC) |
| 63 | M& L for GI flexible conduit size 19 mm as per directed by EIC. |
| 64 | M& L for GI flexible conduit size 25 mm as per directed by EIC. |
| 65 | M&L for brass cable gland nickel plated of size 25 mm inner dia. |
| 66 | supply & fixing of flameproof gland, size 19mm, double compresson type duly certified by CIMFR Dhanbad |
| 67 | supply & fixing of flameproof gland, size 25 mm, double compresson type duly certified by CIMFR Dhanbad |
| 68 | Supply & fixing of 2.5 sq mm copper conductor,1100 V, FR PVC insulated multistrand wire , Polycab/ Finolex/ HPL/V-Gaurd or equivalent make FR PVC insulated earth conductor green colour. |
| 69 | supply & fixing of 6 sq mm copper conductor,1100 V, FR PVC insulated multistrand wire , Polycab/ Finolex/ HPL/V-Gaurd or equivalent make FR PVC insulated earth conductor green colour. |
| 70 | Supply & fixing of crocodile clip heavy duty for earthing as per directed by EIC |
| 71 | Supply & fixing of star delta Starter 30KW/ 40 HP 415V, 3 phase, 50 Hz make - siemens, L&T or equivalent. As per directed by EIC |
| 72 | Supply & fixing of Direct On Line Starter 5.5KW/ 7.5 HP 415V, 3 phase, 50 Hz make - siemens, L&T or equivalent. As per directed by EIC |
| 73 | M& L for self locking nylon cable tie 250mm length* 50 mm width. As per directed by EIC Please Enable Macros to View BoQ information |