| 1 | Supply of 16 Mtrs High Mast, Material of Construction: BS EN 10025 / IS 2062 Thickness of Material, Top Section : 3 MM , Bottom Section: 4 M M, Cross Section of Mast: 20 Sided Polygon, Length of Individual Section, Top Section : 8.350 M trs, Bottom Section:8.350 Mtrs, Base & Top Diameter i) Base Dia : 360 MM (Approx),Top Dia :150 M M (Approx),Type of Joints: Stress Slip Fit Joint, Length of Overlap: 1.5 times the dia. if Insertion, M etal Protection Treatment : Hot Dip Galvanised as per IS 4759/ IS 2629,Thickness of |
| 2 | Supply of feeder pillar shall be of outdoor type, stand mounting,dust and vermin proof panel sha l be made out of FRP. Cable entry sha l be at the bottomand through a detachable gland plate. Labels shall be aluminum anodized. Stand for mounting shall be made out of 40 X 40 X 5 M.S Angle.Feeder pi lar sha l have pad-locking arrangement, The dimensions of the panel sha l be at least 400 (L) X 250 (B) x600 (H), The incomer MCB should be 63 Amps, TPN suitable for 415V , 50 HzSupply. suitable for termination of 4C X 16sq.mm aluminium cables. The flexible cables shall be terminated neatly with insulated lugs of appropriate size, MCB 63A TPN — 1No, 16A SP — 12 Nos,10A SP — 1 No,240V AC Contactor with 63A contacts, 240V AC, Time switch (MAKE: ABB /L& T /lEGRAND only |
| 3 | Supply and fixing of lighting Fixtures of 200 Watt. LED Flood Light with batwing spread in grey corrosion free powder coated aluminium pressure die-cast housing (ADC 12) and Driver Topology – Isolated, Driver Construction (Potted / Open Frame) - Potted, Input Power (W) 200±5%, Input Voltage (V) 230+5%, Input Current (M a) 850 +5%, Power Factor >0.95 , Thd % <10%, Driver Efficiency (%)≥85, Operating Voltage (V)110~290 Vac, Operating Frequency (Hz)50, Output Open Circuit Protection – Yes, Output Short Circuit Protection – Yes, Low Voltage Circuit Protection - Yes, 100 ±15vac , Over Voltage Circuit Protection - Yes, 300 ±15vac, Overload/ Thermal Protection – Yes, Driver Inbuilt Surge Protection ≥4.0kv, External Surge Protection ≥10.0kva, Electric Strength A s Per Is 16102 - 1.5 K v, Led (Nichia, Cree, Osram), 5050, 5w, Luminous Flux(Lumen)±5% 26000, Luminous Efficacy (Lm/W)±5% 130, Colour Temperature (K ) 5500k~6500k, Led Efficacy (Lm/W)±5% >135, Cri ≥70, Product Beam A ngle (Degree) 90° , Working Temperature Range(° C) 10 To +55, Working Humidity Range 0 - 95%, IP Grade IP 66, Product Dimensions 390mmx302mmx140mm, Housing Aluminium Die Casting Corrosion Free Powder Coated , Tilt/ Adjustable Cradle M s, Powder Coated Angle Adjustable Diffuser / Cover Heat Resistance Toughened Glass etc. complete as per direction of the Engineer-in-Charge. (Make : Bajaj / Crompton / Philips / Havells or equivalent make with LED fixture that has been approved by ISO & BIS in corporate the LM 79 & LM 80) |
| 4 | Supply of IP 65 LED Twin Drum Aviation light having epoxy flame orange painted die-cast aluminum a loy housing, with polycarbonate glass, and photoce l for automatic operation for dusk to dawn. Frequency 50 HZ , Luminaire life Expectance : 50000 Hrs. operating input voltage range 100 – 270V AC |
| 5 | Construction of a shalow foundation for a 16-meter high mast using Drawing Grade concrete of specified design mix (minimum M25), including excavation, reinforcement, shuttering, concrete placement, anchor bolt fixing as per high mast manufacturer’ s drawing, and backfi ling, a l based on a safe soil bearing capacity of 10 T/m². The scope includes the supply of all required materials such as cement, aggregates, reinforcement steel (Fe500D), anchor bolts, and non-shrink grout as per the directionof the Engineer-in-Charge. (Erection Part) |
| 6 | Erection, Testing, Commissioning of 16 Meter High Mast with suitable equipment & tools as per the direction of the Engineer-in-Charge.(Erection Part) |
| 7 | Erection, Testing, Commissioning of High Mast feeder Piller with suitable equipment & tools, including supply of Gland, Lux etc. including Concreting as per the direction of the Engineer-in-Charge.(Erection Part) |
| 8 | Supply of 58 MM X 2000 MM Long G.I Earthing , along with Suitable MM G. I Flat , G.I nut bolt etc for connection of earthing to Mast & mast to Feeder (Erection Part) |
| 9 | Supply and laying of size 04 core x 16 sq.mm XLPE insulated armoured underground aluminum cable for power supply from LT Pole to Panel Board including cost of materials, labour, T& P and transportation etc. complete as per direction of the Engineer-in-Charge. (Make - Havels / Nicco / Finolex / KEI (Erection Part) |
| 10 | Supply and stringing of 1½\\" OD HDPE Pipe for stringing of cable for protection armoured cable including cost of materials, labour, T& P and transportation as per direction of the Engineer-in-Charge.(Erection Part) |
| 11 | Supply, fitting and fixing of 0'-1½\\" (40mm) G.I. Pipe medium Gauge for laying of cable inside the road cutting portion etc. complete with transportation, T& P and labour charges as per the direction of the Engineer-in-Charge.(Erection Part) |
| 12 | Earth work in excavation of trenches in a l kinds of soil including B. T. Road, ordinary soil, hard soil or gravelly soil, stoney earth & gravel mixed with slushy soil (in water up to 0.6mdepth requiring the aid of pans & vessels) including dressing, leveling the bed up to required depth & within initial lead of 50mtrs & 1.5mtrs initial lift etc. complete for laying of cable including cost of a l labour charges, T& P required for the work & as per direction ofEngineer in charge.1 x 40 Mtrs. x 0.30 Mtrs.x 0.30 Mtrs. = 3.6 cum. |
| 13 | Providing and laying un-reinforced plain cement concrete pavement with 43 grade cement with M-20 grade mix with 20mm and downgraded screened washed hard black crusher broken granite chipsincluding hoisting, lowering, laying, watering, curring etc. complete as per direction of the Engineer-in-Charge. 1 x 40 Mtrs. x 0.30 Mtrs.x 0.30 Mtrs. = 3.6 cum. Please Enable Macros to View BoQ information |