Name of Work:- Construction of Lecture Hall at SVSU, Palwal
Sl. No. Item Description
1Providing and fixing of Wooden fire rated doors as per BS:476 Part- 20 and 22 and IS 3614 part-1 and part-2 for stability, integrity and thermal insulation. 03 Criteria Wooden door confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI for maximum rating of 2hrs tested either with or without vision panel. Individual Test certificates should be available for glass used in vision lites confirming the required fire ratings.Any deviation in specification other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer Navair International Ltd or subject to architect’s approval. And should be ISO Certified company.Door leaf shall be minimum 50mm thick fully flush door with or without vision lite. 50mm thick shutter, comprising of 75mm x 44mm hardwood internal timber frame work, with infill of 48 kg/m3, ceramic fiber blankets, coated with VIPER FR intumuscent coating on both sides for insulation. The coated insulation shall be sandwiched between maximum 12mm thick HILUX Make Calcium Silicate Boards on both sides (edge to edge on internal Hardwood frame) having a maximum density of 900 Kgs/ Cum, cladded with 3mm ply commercial ply on both faces. (The same can be pasted with 1mm thick laminate (as per approved shade) or replaced with 4mm thick teak ply as per clients requirement at an extra cost) on both sides of the shutter, with 50mm x 10mm hard wood lipping all round the shutter. r. The rebate shall be of 20mm x 54mm in the Door Frame to accommodate the shutter . Both frame and shutter shall be fitted with intumescent Fire seal strips , The shutter fitted with 20x4mm Fire seal and Frame with 2 no. Fire seal of size 10x4mm on all the three sides of the except bottom. The pasting of the ply/veneer/laminate should be done using automatic machine and should be free from any nails or perforations. (FOR STAIRCASE and LIFT LOBBY) . Tata Parvez, Navair, Kutty Make with the prior approval of engineer-in-charge. (N.S.ITEM)
2Supply and fixing the door frame will be made out of Hardwood of maximum section 120 x 70mm and coated with VIPER Fire reatrdent Primer. (FOR STAIRCASE and LIFT LOBBY) . Tata Parvez, Navair, Kutty Make with the prior approval of engineer-in-charge. (N.S.ITEM)FD2
3Supply and fixing SS Ball Bearing Hinges of size 100 x 75 x 3mm complet with SS Screws of BB1953 e ( 4 Nos per panel ) (For Fire Doors).Becker F.S - MS. Navair, Kutty Make with the prior approval of engineer-in-charge. (N.S.ITEM)..
4Supply and fixing Panic Bar Double leaf panic bar. Becker F.S. Navair, Kutty Make with the prior approval of engineer-in-charge(N.S.ITEM)..
5Supply and fixing PEL905 Becker F.S. Make Panic Trim For Operation From The Other Side Of The Panic Bar. (FOR STAIRCASE and LIFT LOBBY FOR FIRE DOORS). Tata Parvez, Navair, Kutty Make with the prior approval of engineer-in-charge (N.S.ITEM)..
6Supply and fixing Mortise Dead Lock with 80mm cylinder body both side key DL7260 Becker F.S. Dead Lock Becker F.S. Dead Lock. (FOR FIRE DOORS). Tata Parvez, Navair, Kutty Make with the prior approval of engineer-in-charge (N.S.ITEM)..
7Supply and fixing SS D Type Pull Handle of size 300mm mm Long of PHD2230. (FOR FIRE DOORS) Tata Parvez, Navair, Kutty Make with the prior approval of engineer-in-charge. (N.S.ITEM)..
8Supply and fixing Door closers of BLC-604 (Required For All Fire Doors Except Shaft Door). Tata Parvez, Navair, Kutty Make with the prior approval of engineer-in-charge. (N.S.ITEM)....
9Supply and fixing Stainless Steel 304 grade 300mm Long Tower Bolt of with necessary screws as required. (For Doors) Tata Parvez, Navair, Kutty Make with the prior approval of engineer-in-charge. (N.S.ITEM)....
10Supply and fixing Anchor fastners of of maximum 120mm length. Make - (For Fire Doors) HILTI, FISHER, Ebco make with the prior approval of engineer-in-charge. (N.S.ITEM)...
11Supply and fixing IS-1212 S88 UL 1784-01 Smoke tested adhesive seal Make Smoke seal batwing type on all side of frame. (For fire doors) Make - LORIENT, Becker FS, PEMKO make with the prior approval of engineer-in-charge. (N.S.ITEM)...
12Supply and fixing 5 MM thick clear Non wire 2 Hr Fire Vision glass 300x300mm. (For fire doors) Saint gobain, Asahi India glass ltd., Borosil make with the prior approval of engineer-in-charge. (N.S.ITEM)...
13Providing and Fixing SS ball bearing hinge (4 x 3 x 3mm). (For Doors) Isuzul, Godrej, Hettich make with prior approval of Engineer-in-Charge. (N.S.ITEM)...
14Providing and Fixing Tower bolt 12` Aluminium. (For Doors) Godrej, Ebco, Hafele make prior approval of Engineer-in-Charge. (N.S.ITEM)...
15Providing and Fixing SS finish door stopper. (For Doors) Godrej/ Ebco/ Hafele make with prior approval of Engineer-in-Charge. (N.S.ITEM)....
16Providing and Fixing SS back stopper. (For Doors) Godrej/ Ebco/ Hafele make with prior approval of Engineer-in-Charge. (N.S.ITEM)...
17Providing and Fixing Pull handle 240 mm. (For Doors) Godrej/ Ebco/ Hafele make with prior approval of Engineer-in-Charge. (N.S.ITEM)...
18Providing and Fixing Ebco SS 304 friction stay-FRS-16. (For Doors) Model of Godrej, Ebco, Hafele make with prior approval of Engineer-in-Charge. (N.S.ITEM)....
19Providing and Fixing Door Closer 60 kg Tto 90 kg (FOR DOORS) of Ebco, Godrez, Hettich make as per prior approval of Engineer-in-Charge.....
20Providing and Fixing Mortise lock and latch with both side handle and keyed cylinder. (FOR DOORS) 5991 NEH-16, 200mm of Ebco, Godrez, Hettich make as per prior approval of Engineer-in-Charge......
21Providing and Fixing ALDROP 16*200mm stainless steal complete in all respect. (For Doors) Ebco, Godrej, Dorset make with prior approval of Engineer-in-Charge. (N.S.ITEM)...
22Providing and Fixing Sliding roller with necessary screws etc. complete as per direction of engineer in-charge (used in Aluminium windows) (FOR ALL WINDOWS) Make:(EBCO,Dorma, hafele) Complete in all respect with the prior approval of engineer in charge. (N.S.ITEM)....
23Providing and Fixing Sliding lock 1925(Manul) model no. -P-SWL-IM of Ebco make with necessary screws etc.(FOR ALL WINDOWS). Make: (EBCO,Dorma, hafele) Complete in all respect with the prior approval of engineer-Incharge. (N.S.ITEM).....
24Providing and Fixing Ebco Euro window handle (brown) for Outward Opening Window. (FOR ALL WINDOWS) - Model E-WH1 with HB of Godrej/ Ebco/ Hafele or make as per prior approval of Engineer-in-Charge. (N.S.ITEM).....
25Providing and Fixing Ebco Euro window handle wid hook (brown) for Inward Opening Window. (FOR ALL WINDOWS) - Model E-WH1 with HB of Godrej/ Ebco/ Hafele or make as as per prior approval of Engineer-in-Charge.. (N.S.ITEM)......
26Providing and laying smooth stone texture paint in colors shade and texture as per approval applied by a coat applied by a spray gun in the desired shade of approved make including sand papering the existing surface of putty, to give it a base for applying primer coat. It also includes scaffolding charges complete in all respect (FOR EXTERIOR WALL PAINITNG) of Heritage Paint, Spectrum, Ultratech make with prior approval of Engineer-in-Charge. (N.S ITEM).
27Extra for Proving V Groove and L groove in granite cladding including cutting of stone, Polishing to give high gloss finish complete in all respect with the engineer in charge.
28Providing and fixing in position Bib cock with wall flange (model CQT-23047) Jaquar, Hindware, Parryware make with prior approval of Engineer in charge. (N.S.ITEM)
29Providing and fixing Hand shower (Health faucet) with 1.0m long easy flex tube in chrome finish and wall hook (model no. ALD-565) Jaquar, Hindware, Parryware make with prior approval of Engineer in charge. (N.S.ITEM)
30Providing and fixing in position two way Bib cock for and hand shower (model CON-041KN) Jaquar, Hindware, Parryware make with prior approval of Engineer in charge. (N.S.ITEM)
31Providing and fixing in position Angle Valve (model No.CON-059KN) of Jaquar, Hindware, Parryware make with prior approval of Engineer in charge. (N.S.ITEM)
32Providing and fixing under counter Basin (model No. CNS-WHT-705) of Jaquar, Hindware, Parryware make with prior approval of Engineer in charge. (N.S.ITEM)
33Providing and fixing in position Bottle trap (model no.ALD-769L300x190) with internal partition 32mm size with 300mm and 190mm Long wall connections pipes and wall flange and waste coupling. (Model no.ALD-705L130) 32mm size full thread with 130mm Height of Jaquar, Hindware, Parryware make with prior approval of Engineer in charge. (N.S.ITEM)
34Providing and fixing Pillar Cock long neck with 450mm long braided Hose (model No. CQT -23021) of Jaquar, Hindware, Parryware make with prior approval of Engineer in charge. (N.S.ITEM)
35PH Providing and Fixing dwc Fittings for double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 including fixing jointing and testing etc. for 150mm Pipe. Supreme make or equivalent as per prior approval of Engineer-in-Charge. (N.S.ITEM)ROTO DWC BEND 90D
36Providing and fixing 100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg ) range, 3 / 8 ` BSP bottom entry on Pump Delivery Line complete with Ball valve. (N.S.ITEM)
37Supply, installation, testing and commissioning of electrical control panel fabricated out of 2 mm thick CRCA sheet duly powder coated, dust, damp and vermin proof suitable for automatic operation of electric driven fire pumps of capacity upto 12.5 HP including suitable rating 4 pole MCCB as incomer, contactors, relays, single phase preventer, digital ammeter and volt meter with selector switches, auto/manual selector switch, RYB indicating lights, remote operation box for operation of pumps from ground floor control room, control wiring with suitable rating cable from remote box to control panel complete as required asper direction of Engineer-in-Charge. (CPRI Approved) (N.S.ITEM)
38Supplying and fixing hose cabinet of size 900mmx600mmx500mm made of 2 mm thick MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15mtr. Long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duty painted with post office red externally and white internall with synthetic enamel paint complete in all respects for external hydrant, as directed by enginner-in-charge. (N.S.ITEM)
39Providing, installation, testing and commissioning of gun metal ball valves of following sizes as required. (N.S.ITEM)25 mm dia. (N.S.ITEM)
40Providing, installation, testing and commissioning of gun metal ball valves of following sizes as required. (N.S.ITEM)50 mm dia. (N.S.ITEM)
41Supplying, fixing, testing and commissioning of 25mm Air release valve in as per IS:14845 ISI Marked. (N.S.ITEM)
42Supply and Fixing of Fire Man`s Axe with heavy Insulated rubber tested up to 20 KV and confirming to IS :926 as required. (N.S.ITEM)
43Providing and fixing of carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (N.S.ITEM)capacity 4.5 kg ns item
44Providing and fixing of carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (N.S.ITEM)22.5kg CO2 fire extingusher trolly base. (N.S.ITEM)
45Providing and fixing of ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (N.S.ITEM)Capacity 4.0 Kg. (N.S.ITEM)
46NS ELC, Supply, unloading, installation, testing and commissioning of the following cubical type panels made of 2.0 CRCA structure, base channe lSMC, doors and sheet metal partitions complete with, Moulded Case Circuit Breakers, meters, indicating lamps, current transformer, control MCB etc. Complete in all respects, insulated bus bars with heat shrinkable PVC sleeve, supported on FRP / SMC supports in suitable bus chambers, interconnection, small wiring, name plate, danger plate, earth bus etc. and comprising of compartments with hinged door for each feeder and its accessories, cable alley with hinged doors, bus chamber with bolted door etc. The panel being of dust and vermin proof construction with rubber gasket, attractively powder coated with Approved Paint shade. The panel shall be free standing type/ wall mounted type as per relavant drawing and comprising with foundation and Masonary works including ducting. (N.S ITEMS) `Note:- MCCB`s upto 250A shall be with Adjustable thermal-magnetic release with O/C and S/C protection of 25kA and above 250A Microprocessor based adjustable release with O/C , S/C and E/F protection of 36kA. All MCCB`s shall be provided with front door operating handle, Phase Spreaders and Phase Barriers. TPN MCCB Shall mean 3 Pole MCCB with Adequate size of heavy duty separate neutral link.Metering CTs burden shall be 15VA and accuracy class 1.0.CTs shall be ``Cast Resin`` type .All indication lights shall be LED type.All meters shall be ``DIGITAL`` type.Degree of Protection for Indoor panels shall be IP-54. (N.S. ITEMS)` `Degree of Protection for Outdoor panels shall be IP-55 with canopy and double door. Outdoor panel cable entry shall be from bottom only.Panel space heaters with control MCB and Thermostat, covered CFL lamp controlled by door switch for each panel bay.Gland plates shall be 2mm thick for LT. Panels upto 400A Incomer and 3 mm thick for LT. Panel with 630A and above incomer.Panel Manufacturer should have Type Test Certificates for Short Time withstand current test of 50KA for 1.0 Sec from CPRI Bhopal / Bangalore.``ON`` and ``OFF`` Indicating lamp with control mcb shall be provided for all MCCB out going feeders unless otherwise specified.Control SP MCB`s of 2 /4A Rating shall be provided for each metering circuit. ` MDB PANEL `Incoming1 No. 800 Amp FP Moulded case circuit breaker with microprocessor based release with O/C, S/C and E/F protection.Bus bars1 Set of 1000-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Aluminium bus-bars with colour coded PVC heat shrinkable sleeves.Metering and IndicationOne set of R/Y/B phase indication Lamp and MCB.1 No. Multi Function Meters (A/V/kW/kWh)ON/OFF/TRIP indication lamp for incomer (N.S. ITEM)` `Outgoing7 No.100 Amps FP MCB, ``C`` of 16kA9 No. 63 Amps FP MCB, ``C`` of 10kA8 No. 40 Amps FP MCB, ``C`` of 10kAPanel as mentioned above should be complete in all respect with internal wiring, al. bus bar etc. .(N.S. ITEM)Placed at electrical shaft`
47UPS O/P PANEL `Incoming2 No. 63 Amp FP MCB,10 kA D CurveBus bars1 Set of 150-Amps, 3-Phase, 4-wire, 415 volts, 50 Hz Copper bus-bars with colour coded PVC heat shrinkable sleeves.IndicationON/OFF indication lamp for incomer (N.S. ITEM)` `Outgoing9 No. 40 Amps DP MCB, ``D`` of 10kAPanel as mentioned above should be complete in all respect with internal wiring, Cu. bus bar etc. .(N.S. ITEM)Placed in electrical room`
48`Supply,Installation, Testing and commissioning of of 10W 2FT LED batten luminaires with housing made of Aluminum Extrusion for thermal management with an anodized finish. Luminaire should be suitable for Wall/Ceiling mounting with SS clamps. Luminaire shall deliver excellent illumination and visual comfort with CRI of )80, High transmittance Opal Polycarbonate diffuser for glare-free symmetric light distribution. Luminaires should be with min 100 lm/W System Efficacy and designed for Avg. LED Life (L70 B50) 50,000 Burning Hours and with high efficient Photobiologically safe LEDs. Luminaire should be Powered by an integral electronic constant current driver offering THDi(10% , compliance, Output Short-circuit protection, Surge Voltage protection, and other reliability tests as per IS:15885 Part 2/Sec 13. Luminaires should be provided with 2.5kV surge protection. Luminaires manufacturer to have an in-house NABL-accredited Laboratory for testing Photometric parameters. (N.S. ITEMS)Used in Toilet at each floor`
49`Supply, Installation, Testing and Commissioning of 10W Bulk Head Fixture made with system efficacy not less than 80 lm/w. (N.S. ITEMS)Used in lifts at each floor and terrace floor`
50SITC of Microprocessor based Networkable Multi loopdelet analogue addressable expandable upto 2 Loops fire alarm control panel. The control panel is designed with ARM Cortex-M4 32-bit microcontroller with high resolution (480 X 272 pixels) 4.3 inch graphics TFT LCD display or better / Qwerty Key Pad with symbolic representation for power status, The system status and control keys with symbolic representation for easy access. The panel status shall be visualized on LCD/LED in unambiquese color. This panel can operate as a standalone or connect up to Minimum 16 panels in a network for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the panel configuration using the Configuration tool, One dedicated Fault Relay, 10000 events log with RTC, Numaric keypad for menu access. The panel should be equipped with sufficient numbers of loop with 20% spare capacity with each loop shall have a capacity of 250 analog addressable devices in one loop. The panel shall have a built in power supply and operate 110 / 230VAC plus 10% – 15%, 60 / 50 Hz, 450W,The panel shall have its own battery backup of a minium 24 hours in normal run and 5 minitues in the alarm condition.. Optional: for BMS integration thru BACnet/MODBUS converter, Graphical Software,TCP/IP Module, provision for GSM based Auto dialler,Approval UL 864 -10th Edition. 2 Loop Panel (with Network Cards) (N.S. ITEMS)
51`SITC of Intelligent Addressable Multi-Sensor (Optical Smoke ) detector with base. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. (UL and ULC Listed and FM Approved). (N.S.ITEMS)Used in corridoors, common areas and rooms at each floor`
52`SITC of analog Addressable Manual Pull Station -Double Action with inbuilt fault isolator and back box and Break Glass Rod, shall be resettable by Align key to avoid unauthenticated restorations, monitoring the field NO/NC devices. Shall have Binary Coding Setting Dip Switch, The MCP shall have operating temperature range from 0°C to 49°C and humidity tolerance range up to 93% RH, Non-Condensing. Complete with termination and testing as per requirement and as per specification. - `UL Listed (N.S.ITEMS)Used in corridoors at each floor`
53Supply, installing, testing and commissioning of Fault Isolator Module capable of monitoring short on SLC loop circuit also isolate wire-to-wire short circuits on an loop of type Class - A and automatically restore communications when shorted conditions are corrected. The fault isolator module and its mounting shall be as per technical specification(N.S.ITEMS)
54`SITC of addressable wall mount 4 wires addressable sounder- Strobe fixing box having minimum sound pressure level of 95dBA @1mtr,operting on 24vDC external power, Candela Low and High can be selected using DIP switch,flasher frequency 1HZ per second, shall have 7 Different tone selection by using DIP 6-way DIP switch ,Adjustable volume control,Sounder and strobe OFF facility.It shall be RED in colour. Complete with termination and testing as per requirement and as per specification, Cable wiring for the termination should be at base of sounder-strobe and head shall be installed seperately.(N.S.ITEMS)Used in corridoor areas at each floor.`
55`SITC of analog Addressable Monitor Module for monitoring the field NO/NC devices for input from 3rd party devices, Fire pumps, Flow switch etc. It shall be configurable for supervisory or alarm and should be as supervised for Class B wiring.Shall have Binary Coding Setting Dip Switch,Shall have an Tri color LED indiaction for normal and Active Modes- - Approval: UL Listed (N.S.ITEMS)Used in fire shaft at each floor`
56`SITC of Relay/Control ouput module for Extract Fan/toilet fresh air/ pressurization fans / solenoid valves/Tenant,Tri color LED indiaction for normal and Active Modes status,The module shall be as per technical specification-.Approval: UL Listed, 10th edition (N.S.ITEMS)`
57Supplying and Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. (N.S.ITEMS)
58Supplying, laying, testing and commissioning of 1.1KV grade copper conductor armored FIRE SURVIVAL cable with LSZH insulation as per BS 7846:2009 and IEC-60502:2004 Part-1 (Armored), Retain circuit integrity as per BS 6387 C.W.Z (armored), BS-8491:2008, BS 8434-2: 2009 (armored), (Resistance to fire at 950º C for 3 hours), as per specifications in cable trays, clamped including anchor fasteners to wall with suitable clamps, saddles fixing bolts, complete in all respect and as per specifications. (N.S. ITEMS) 2x1.5 sq.mm (N.S. ITEMS)
59Supplying, laying, testing and commissioning of 1.1KV grade copper conductor armored FIRE SURVIVAL cable with LSZH insulation as per BS 7846:2009 and IEC-60502:2004 Part-1 (Armored), Retain circuit integrity as per BS 6387 C.W.Z (armored), BS-8491:2008, BS 8434-2: 2009 (armored), (Resistance to fire at 950º C for 3 hours), as per specifications in cable trays, clamped including anchor fasteners to wall with suitable clamps, saddles fixing bolts, complete in all respect and as per specifications. (N.S. ITEMS) 2x2.5 sq.mm (N.S. ITEMS)
60FIRE FIGHTER`S HANDSET, TELPHONE JACK and CONSOLE (N.S. ITEMS) `Supply, installing, testing and commissioning of 2 way communication Fire Fighter`s Handset (N.S. ITEMS)Placed at ground floor`
61`Supply, installing, testing and commissioning of 2 way communication Fire Fighter`s Telephone Jack (N.S. ITEMS)Used in staircase each floor`
62Supplying, installation, testing and commissioning of fire fighter phone Console complete as required and as per specifications.(N.S. ITEMS)
63`SITC of emergency fire exit sign boards, with both side display provision with suitable hanging arrangment complete in all respect as required. (N.S. ITEMS)Used for fire exit at each floor`
64`Supply, installation, testing and commissioning of 240 Watt Amplifier complete with interconnecting Cables, Rack mount Version.(Wattage Considered at 6W Tapping) with BMS Connectivity suitable Modules.. (N.S. ITEMS)`
65Supply, installation,testing and commissioning of Dual Tone Ceiling mounted speaker with all recquisite mouting accessories to mount the speaker on False Ceiling / True Ceiling. Back box and cable termination for the same included in this item.
66`Supply, Installation, Testing and Commissioning of IP Network TDN Low-Light IR 2 Megapixel fixed Dome Camera, lens - 2.8mm/3.6mm/6.0mm , 1/3” CMOS image sensor, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, 3D NR, Privacy Mask, 3 IR LEDs Smart IR with upto 30m IR distance, ONVIF Profile S and Profile G compliant,IP66, IK10, PoE, CSA 60950-22, CE (EN 50130-4 and EN 55022) , FCC Part 15 and RoHS compliant complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. (N.S.ITEMS)Used in corridoors aech floor.`
67Supply, installation, testing and commissioning with proper connection and termination of following size equipment rack made out of CRCA sheet to house all the control equipment complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. (N.S. ITEMS) `9U Wall Mounted rack (N.S. ITEMS)Used at LV shaft at each floor.`
68Supply, installation, testing and commissioning of Layer-2 PoE plus Managed Distribution Switch 8 Gigabit Ports, Rack Mountable, Switch competible Fibre module Uplink- 2port 10G SFP plus , 2 port 1g SFP for LAN base feature set with support to integration with CCTV, with all related hardware complete as required and as per specifications (N.S.ITEMS)
69Supply, installation, testing and commissioning of full HD 32` LED display with all accessories complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. (N.S.ITEMS)
70`Supply, laying of following sizes GI Raceway of 1.3 mm Thickness complete with all accessories including junction box with 3 mm thick cover plate, neoprene gasket in joints, cutting the floor and jamming the raceway with all necessary hardware (including civil works) as required. (N.S. ITEMS)` `150 x 38 mm (N.S. ITEMS)Used in ground floor corridoor and LV shaft`
71Supply installation and testing and commissioning of follwing size of Telephone distribution board in a M.S. box with hinged cover/ door complete with krone type tag block with double jumpering facility mounted on a bakelite sheet etc. including terminations of cable as required. (N.S. ITEMS) `20 PairUsed in ground floor and Third Floor` .,1
72Supply, erection and laying of 6 core Fiber Optics cables with accessories including terminations etc complete in all respect (N.S. ITEMS)
73Supply, erection and laying of arm/ unarm cable on trays with Cable tie, clamp, dressing etc complete in all respect (N.S. ITEMS) 4 core 10 sq.mm CU. XLPE ARM CABLE (N.S. ITEMS)
74Supply, erection and laying of arm/ unarm cable on trays with Cable tie, clamp, dressing etc complete in all respect (N.S. ITEMS) 4 core 16 sq.mm CU. XLPE ARM CABLE (N.S. ITEMS)
75Supply, erection and laying of arm/ unarm cable on trays with Cable tie, clamp, dressing etc complete in all respect (N.S. ITEMS) 3 core 10 sq.mm CU. XLPE ARM CABLE (N.S. ITEMS)
76Supply and installation of UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 25 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 and UL 467. (N.S. ITEMS)
77Supply and laying of 8SWG GI Wire laid in trench / tray / ground. (N.S. ITEMS)
78Supply and laying of 50X 6mm GI Strip laid in trench / tray / ground. (N.S. ITEMS)
79Supply and installation earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 -25 kg (N.S. ITEMS)
80Supply and fixing of Earth Chamber Inspection Pit made up of poly propylene material. (N.S. ITEMS)
81Supply and Installation of First aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS : 2217-1963. (N.S. ITEMS)
82Supplying Supply, Installation, Testing and Commissioning of following size Modular socket outlet (outdoor type), IP-66, complete in all respects as required. (N.S. ITEMS) `25 Amp, 1-phase modular Socket with switch (N.S. ITEMS)Used for A.C. at each floor`
83Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- (NS ITEM)) 80 amp. MCB`s Four Pole (NS ITEM)
84`Supply, installation, testing and commissioning of 63A FP (Four Pole) isolator (without MCB) housed in indoor enclosure , suitable for incoming and outgoing terminations, copper conductors, glands, lugs, ferrules, labeling, mounting accessories, and all incidental works required for safe and reliable operation.MCB of this item is considered in item no 14.4 in Scheduled items(NS ITEM)`
85Supply installation testing and commissioning of 20kVA Online Double Conversion UPS system with advanced IGBT based multi-level PWM Rectifier and Inverter with Feedforward control system. (For UPS POWER SOCKETS and EM. LIGHTING) AC-AC efficiency )96%, Input Power factor )0.99, Input THDI (3%, at rated load: Product design life 15 plus years(NS ITEM) `Battery housing and connecting accessories includes. • Open type ventilated MS Battery racks • Interconnecting Nyvin cable connectors • Nyvin DC cables up to 10 Meters running length between UPS and Batteries.• Battery disconnector with accessories – 1 No` `12V, VRLA batteries as per the RFPMake, Model: Quanta / Exide/Enr-Rocket64 AH Capacity Battery-32 Nos Backup Selection as per RFP: 90mins`
86`Providing and fixing solid laminated flush door shutters having uniform thickness of 37mm with smooth finish and moisture content 10 to 12% with water absorption of 2%, climate stable, warp and bend free as certified by IS-2202 with 1mm HPL conforming to IS - 2046 including , screws chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position).(FOR ROOMS and TOILETS) (Greenlam, century make, duro)(N.S ITEM).`D1
87NS Item -Providing and fixing in position European Type Wall Mounted Water Closet (white) Suit of size(mm), (Model No. CNS-WHT363SPPZ) of Jaguar, Hindware, Cera make with prior approval of Engineer-in-Charge. complete in all respects. (N.S ITEM)
88NS Item -Providing and fixing floor drain (B)with jali as per I.S:14735:1999 marked of supreme pipes, Finolex, Prince make with prior approval of Engineerin charge. (N.S ITEM)
89NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) FLOOR TRAP WITH TOP TILE and STAINER(100mm)
90NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) FLOOR TRAP WITH TOP TILE and STAINER(125mm))
91NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) door tee
92NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) door band (ts)
93NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) band 87.5 degree
94NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) Door Cross Tee
95NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) COUPLER
96NS Item -ph Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) DOOR CAP
97NS Item -PH Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) VENT COWL WITH PREMIUM WIREMESH
98NS Item - PH Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) MULTI FLOOR TRAP
99NS Item -PH Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 110mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) CLEANOUT
100NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 160mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) DOOR TEE
101NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 160mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) COUPLER (RIB TYPE)
102NS Item -Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 160mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) VENT COWL
103NS Item - ph Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 160mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) DOOR ELBOW
104NS Item -ph Providing and Fixing SWR Fittings ( supreme pipes, Finolex, Prince make) for type B pipes 160mm dia including fixing jointing and testing etc. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) CLEANOUT
105NS Item -PH Providing and Fixing dwc Fittings for double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 including fixing jointing and testing etc. for 150mm Pipe. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) ROTO DWC BEND 45D
106NS Item -PH Providing and Fixing dwc Fittings for double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 including fixing jointing and testing etc. for 150mm Pipe. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) ROTO EQUAL TEE
107NS Item -PH Providing and Fixing dwc Fittings for double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 including fixing jointing and testing etc. for 150mm Pipe. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) ROTO CROSS TEE
108NS Item - PH Providing and Fixing dwc Fittings for double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 including fixing jointing and testing etc. for 180mm Pipe. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) ROTO DWC BEND 90D
109NS Item - PH Providing and Fixing dwc Fittings for double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 including fixing jointing and testing etc. for 180mm Pipe. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) ROTO DWC BEND 45D
110NS Item -PH Providing and Fixing dwc Fittings for double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 including fixing jointing and testing etc. for 180mm Pipe. supreme pipes, Finolex, Prince make as per prior approval of Engineer-in-Charge. (N.S.ITEM) ROTO EQUAL TEE
111`Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : (DSR-20.1)`500 mm dia piles. (DSR-20.1.3)
112`Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification and the direction ofEngineer in-charge. (DSR-20.6)`Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile above 50 tonne and upto 100 tonne Safe capacity. (DSR-20.6.2)Initial test (Test Load 2.5 times the Safe capacity). (DSR-20.6.2.1)
113`Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification and the direction ofEngineer in-charge. (DSR-20.6)`Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Routine test (Test Load 1.5 times the Safe capacity). (DSR-20.6.2.2)
114Lateral load testing of single pile in accordance with IS : Code of practice IS: 2911 (Part IV) for determining safe allowable lateral load on pile :(DSR-20.8)Above 50 tonne and upto 100 tonne capacity pile. (DSR-20.8.2)
115Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS :14893 including surface preparation of pile top by removing soil, mud, dust and chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test and submission of results, all complete as per direction of Engineer-in-charge. (DSR-20.9)
116Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS :14893 including surface preparation of pile top by removing soil, mud, dust and chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test and submission of results, all complete as per direction of Engineer-in-charge. (DSR-20.9)
117[10.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. [Through Rate]
118[10.107]Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 0 0 0 [Through Rate]
119[10.4]Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. [Through Rate]
120[10.45]Extra for pre finished nosing to treads of steps of marble stone. [Through Rate]
121[10.49.1]Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 1. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
122[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
123[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate]
124[10.59]Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. [Through Rate]
125[10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate]
126[10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate]
127[10.67.2]Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm [Through Rate]
128[10.70.2]Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm [Through Rate]
129[11.15]6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. [Through Rate]
130[11.16]Extra for addition of synthetic Polyester triangular fibre of length 6 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement plaster/mortar by using 125 gms. of synthetic Polyester triangular fibre for 50 kgs. cement used in cement mortar as per directions of Engineer-in-Charge. [Through Rate]
131[11.17]Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge [Through Rate]
132[11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) [Through Rate]
133[11.47.2]12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): 2. Sunk Band [Through Rate]
134[11.47.3]12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): 3. Raised Band [Through Rate]
135[11.48.2]18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand): 2. Sunk Band [Through Rate]
136[11.48.3]18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand): 3. Raised Band [Through Rate]
137[11.5.4]12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand) [Through Rate]
138[11.59]Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. [Through Rate]
139[11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) [Through Rate]
140[11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate]
141[11.75.2]Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. 2. Two coats [Through Rate]
142[11.91]Melamine polishing on wood work (one or more coat). [Through Rate]
143[12.157.1.3]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.3. For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) [Through Rate]
144[12.157.2.3]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.3. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) [Through Rate]
145[12.159.2]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) [Through Rate]
146[12.3.3.2.2]Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 3.2.2. Kiln seasoned and chemically treated Hollock wood 50x20 mm [Through Rate]
147[13.21.2]Supply and fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm and Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets and screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification and entire satisfaction of Engineer-in-charge. 2. Door Frame of size 125mm x 60mm with 37mm wide double rebate for 35mm door shutter [Through Rate]
148[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate]
149[20.11.2]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 2. 100 mm i/d [Through Rate]
150[20.11.3]Providing and fixing cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge 3. 150 mm i/d [Through Rate]
151[20.26.1]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 1. 11.43 cm thick wall [Through Rate]
152[20.26.2]Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 2. 22.86 cm thick wall [Through Rate]
153[20.36]Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. [Through Rate]
154[20.49.1]Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Size of the main with which connection is to be made. 1. Up to 200 mm internal diametre [Through Rate]
155[20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate]
156[20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate]
157[20.84]Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge [Through Rate]
158[21.84.3]Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. 3. Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) [Through Rate]
159[21.85.3]Extra for every 0.30 metre depth of Inspection chamber 3. 600 mm x 900 mm inside [Through Rate]
160[21.87.1.2]Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar (as Specified in item No. Item 21.48) complete to the requirement of the Engineer in-charge 1.2. Single road gully chamber - Size.-610 mmx457 mmx1105mm [Through Rate]
161[21.98.1]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 1. 200 mm Outside Dia [Through Rate]
162[21.98.2]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 2. 225 mm Outside Dia [Through Rate]
163[21.98.3]`Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade and PN- 8 for sewer application as per IS 14333-1996 (amended up to date) in trenches in complete including cost of HDPE `Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment.` 3. 250 mm Outside Dia. [Through Rate]
164[22.101.1.1]Providing and fixing Unplasticised PVC connection pipe with brass unions : 1.1. 30 cm length 15 mm nominal bore [Through Rate]
165[22.103.1]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore [Through Rate]
166[22.103.2]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 2. 20 mm nominal bore [Through Rate]
167[22.103.3]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 3. 25 mm nominal bore [Through Rate]
168[22.109]Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. [Through Rate]
169[22.166.2.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 2.2. 150 x 100 mm size P type With sewer bricks conforming to IS : 4885 [Through Rate]
170[22.166.3.2]Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 3.2. 180x150 mm size P type With Sewer bricks conforming to IS : 4885 [Through Rate]
171[22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. [Through Rate]
172[22.190.1.2]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 1.2. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885 [Through Rate]
173[22.190.2.2]Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 2.2. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With Sewer bricks conforming to IS : 4885 [Through Rate]
174[22.191.1.2]Extra for depth for manholes : 1.2. Size 90x80 cm With Sewer bricks conforming to IS : 4885 [Through Rate]
175[22.191.2.2]Extra for depth for manholes : 2.2. Size 120x90 cm With Sewer bricks conforming to IS : 4885 [Through Rate]
176[22.209]Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [Through Rate]
177[22.210.4]Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 4. Rectangular shape 1500x450 mm [Through Rate]
178[22.211]Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. [Through Rate]
179[22.222.2.1]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete [Through Rate]
180[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]
181[22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete [Through Rate]
182[22.222.2.4]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete [Through Rate]
183[22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate]
184[22.42.1]Providing and fixing toilet paper holder : 1. C.P. brass [Through Rate]
185[22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. [Through Rate]
186[22.81.1]Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1. 100 mm dia [Through Rate]
187[22.81.2]Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 2. 75 mm dia [Through Rate]
188[22.81.3]Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 3. 50 mm dia [Through Rate]
189[22.83]Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. [Through Rate]
190[22.86.1]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes [Through Rate]
191[22.86.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate]
192[22.86.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate]
193[22.86.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes [Through Rate]
194[22.87.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 3. 25 mm nominal outer dia Pipes [Through Rate]
195[22.87.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 4. 32 mm nominal outer dia Pipes [Through Rate]
196[22.87.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 5. 40 mm nominal outer dia Pipes [Through Rate]
197[22.87.6]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 6. 50 mm nominal outer dia Pipes [Through Rate]
198[22.87.7]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 7. 62.50 mm nominal inner dia Pipes [Through Rate]
199[22.88.3]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 3. 25 mm dia nominal bore [Through Rate]
200[22.88.6]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 6. 50 mm dia nominal bore [Through Rate]
201[22.94.4]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 4. 32 mm nominal bore [Through Rate]
202[22.94.5]Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 5. 40 mm nominal bore [Through Rate]
203[22.97.1]Providing and fixing brass stop cock of approved quality : 1. 15 mm nominal bore [Through Rate]
204[22.97.2]Providing and fixing brass stop cock of approved quality : 2. 20 mm nominal bore [Through Rate]
205[23.20]Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required [Through Rate]
206[23.21]Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required [Through Rate]
207[23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) [Through Rate]
208[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]
209[23.22.4.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.8. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate]
210[23.22.4.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) [Through Rate]
211[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
212[23.22.5.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole [Through Rate]
213[23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate]
214[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate]
215[23.22.6.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.1. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 25 A [Through Rate]
216[23.22.6.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.2. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 40 A [Through Rate]
217[23.22.6.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 6.3. Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 63 A [Through Rate]
218[23.23.6..2]MISCELLANEOUS 6..2. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm [Through Rate]
219[23.23.6.1]MISCELLANEOUS 6.1. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100 X 50 X 2 mm [Through Rate]
220[23.23.6.3]MISCELLANEOUS 6.3. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 375 X 50 X 2 mm [Through Rate]
221[23.23.6.4]MISCELLANEOUS 6.4. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 600 X 50 X 2 mm [Through Rate]
222[23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire [Through Rate]
223[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
224[23.28.11.4]Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. Powder coated die cast /Extruded aluminum Body (Thickness >= 1.20 mm) 40 Watt [Rate]
225[23.28.3.2]Supplying, installation, Testing and Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 2. Powder coated die cast / Extruded aluminum Body including trim 8-10 watt [Rate]
226[23.28.3.3]Supplying, installation, Testing and Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 3. Powder coated die cast / Extruded aluminum Body including trim 12-15 watt [Rate]
227[23.28.3.4]Supplying, installation, Testing and Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. Powder coated die cast / Extruded aluminum Body including trim 18 watt [Rate]
228[23.28.8.2]Supplying, installation, Testing and Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 2. Powder coated die cast / Extruded aluminium Body (Thickness >= 1.20 mm) 18 watt [Rate]
229[23.3.1.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate]
230[23.3.3.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 3.3. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C [Through Rate]
231[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
232[23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
233[23.3.6.4]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]
234[23.4.1.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C [Through Rate]
235[23.4.4.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C [Through Rate]
236[23.4.5.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C [Through Rate]
237[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
238[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate]
239[23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type [Through Rate]
240[23.8.11.7]FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt [Through Rate]
241[23.8.11.8]FITTING AND ACCESSORIES 11.8. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Telephone Socket outlet modular type [Through Rate]
242[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate]
243[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
244[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]
245[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
246[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
247[24.14.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate]
248[24.14.30]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 30. 25 Sq mm 3.5 core (Arm.) [Through Rate]
249[24.14.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.) [Through Rate]
250[24.2.6.5]LT CABLE 6.5. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 10 sqmm [Through Rate]
251[24.2.6.6]LT CABLE 6.6. Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 16 sqmm [Through Rate]
252[24.2.7.2]LT CABLE 7.2. Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core [Through Rate]
253[24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate]
254[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core [Through Rate]
255[24.2.8.11]LT CABLE 8.11. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 150 sqmm [Through Rate]
256[24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm [Through Rate]
257[24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate]
258[24.2.8.15]LT CABLE 8.15. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 400 sqmm [Through Rate]
259[24.2.8.3]LT CABLE 8.3. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 10 sqmm [Through Rate]
260[24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate]
261[24.2.8.5]LT CABLE 8.5. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm [Through Rate]
262[24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia [Through Rate]
263[25.11.2.4]HI - WALL SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS:1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). 4. Inverter Type- Cooling only 2.0 TR with 5 Star BEE Rating [Rate]
264[25.3.10]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 10. 40mm dia. [Through Rate]
265[25.3.9]Supplying, fixing, testing and commissioning of Butterfly valves PN 16 rated without insulation for water circulation as per specifications. 9. 50 mm dia. [Through Rate]
266[25.9.11.2.2]Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. 2.2. NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified 150 mm dia. [Rate]
267[25.9.11.2.4]Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. 2.4. NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified 100 mm dia. [Rate]
268[28.23]Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. [Through Rate]
269[28.50]Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) ) 78, solar reflection ) 0.70 and initial emittance ) 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. [Through Rate]
270[29.5]Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. [Through Rate]
271[29.6]Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. [Through Rate]
272[30.88.2]Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 2. For pipes 250 to 300 mm diameter [Through Rate]
273[36.10.1]Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required: 1. Single headed Stainless steel [THROUGH RATE]
274[36.11.4]Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 4. 80 mm dia [THROUGH RATE]
275[36.11.5]Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 5. 100 mm dia [THROUGH RATE]
276[36.11.6]Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 6. 150 mm dia [THROUGH RATE]
277[36.16.1]Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required: 1. Gun Metal [THROUGH RATE]
278[36.17.1]Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type 2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve and nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. 1. 30m [THROUGH RATE]
279[36.18.1]Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneousconnection to interconnect hose pipe coupling as required: 1. Gun Metal [THROUGH RATE]
280[36.19.1]Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 1. 2 way-100 mm dia M.S. Pipe [THROUGH RATE]
281[36.20]Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve withrequired accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. [THROUGH RATE]
282[36.21.1]Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 °C with required accessories: 1. Pendent Sprinkler [THROUGH RATE]
283[36.21.2]Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 °C with required accessories: 2. Upright Sprinkler [THROUGH RATE]
284[36.21.3]Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 °C with required accessories: 3. Horizontal side wall sprinkler [THROUGH RATE]
285[36.22.1]Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. 1. 100mm dia [THROUGH RATE]
286[36.22.2]Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. 2. 150mm dia [THROUGH RATE]
287[36.23.1]Providing and fixing flow switch in following sizes M.S. pipe including connection etc as required. 1. 100mm dia [THROUGH RATE]
288[36.25.1]Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1. 700mm [THROUGH RATE]
289[36.25.2]Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 2. 1000mm [THROUGH RATE]
290[36.25.3]Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 3. 1200mm [THROUGH RATE]
291[36.25.4]Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 4. 1500mm [THROUGH RATE]
292[36.4.1](a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-`F` insulation,conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 1. 900 lpm at 35 M Head [THROUGH RATE]
293[36.6.2]Providing laying, testing and commissioning of `C` class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 2. 150 mm. Dia [THROUGH RATE]
294[36.7.1]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 1. 25 mm dia [THROUGH RATE]
295[36.7.2]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 2. 32 mm dia [THROUGH RATE]
296[36.7.3]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 3. 40 mm dia [THROUGH RATE]
297[36.7.4]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 4. 50 mm dia [THROUGH RATE]
298[36.7.5]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 5. 65 mm dia [THROUGH RATE]
299[36.7.6]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 6. 80 mm dia [THROUGH RATE]
300[36.7.7]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 7. 100 mm dia [THROUGH RATE]
301[36.7.8]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 8. 150 mm dia [THROUGH RATE]
302[36.9.1]Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steelcap and chain as required. 1. Single headed Stainless steel [THROUGH RATE]
303[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
304[4.16.1.1]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.1. All kind of soil Pipes, cables etc, not exceeding 80 mm dia . [Through Rate]
305[4.16.1.2]Excavating trenches of required width and depth for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. 1.2. All kind of soil Pipes, cables etc, exceeding 80 mm dia but not exceeding 300 mm dia. [Through Rate]
306[4.31.1]Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 1. All kinds of soil [Through Rate]
307[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
308[4.39]Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% [Through Rate]
309[4.4.1]Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 1. All kinds of soil [Through Rate]
310[4.40.5]Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 5. Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. [Through Rate]
311[5.25]Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. [Through Rate]
312[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate]
313[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate]
314[6.10]Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. [Through Rate]
315[6.13]Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth. [Through Rate]
316[6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate]
317[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]
318[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]
319[6.26.1]Extra for providing richer mixes up to plinth and at all floor levels. 1. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) [Through Rate]
320[6.26.2]Extra for providing richer mixes up to plinth and at all floor levels. 2. Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement content considered in M-35 is @ 350 kg/ cum) [Through Rate]
321[6.27]Extra for R.C.C./ B.M.C/ R.M.C. work above floor IV level for each three floors or part thereof. [Through Rate]
322[6.30.1]Centering and shuttering including strutting, propping etc. and removal of form for 1. Foundations, footings, bases of columns, etc. for mass concrete [Through Rate]
323[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. [Through Rate]
324[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
325[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]
326[6.30.6]Centering and shuttering including strutting, propping etc. and removal of form for 6. Columns, Pillars, Piers, Abutments, Posts and Struts [Through Rate]
327[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]
328[6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate]
329[6.59.3.2]Providing and fixing sheet covering over expansion joints with iron screws as per design. 3.2. Cement bonded wood particle board 6mm thick as per IS : 14276 200 mm wide [Through Rate]
330[6.60.1]Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 1. 200 mm wide. [Through Rate]
331[6.61.1]Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminium base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it`s components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063). 1. Floor Joint of 100 mm gap [Through Rate]
332[6.62.1]Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings and complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). 1. Wall Joint of 100 mm gap [Through Rate]
333[6.63.1]Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). 1. Roof Joint of 100 mm gap [Through Rate]
334[6.9.1]Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) 1. 50 mm thick [Through Rate]
335[6.9.2]Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) 2. 40 mm thick [Through Rate]
336[7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate]
337[7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate]
338[7.27.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in foundations and plinth in : 2. cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
339[7.28.2]Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level. 2. Cement mortar 1:4 (1 cement :4 coarse sand) [Through Rate]
340[7.51]Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor IV level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). [Through Rate]
341[8.26.2.1]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.1. Granite of any colour and shade Area of slab up to 0.50 sqm [Through Rate]
342[8.27.2]Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 2. Granite work [Through Rate]
343[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate]
344[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate]
345[9.46.3]Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer`s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 3. 12.5 mm thick tapered edge gypsum moisture resistant board [Through Rate]
346[9.48]Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. [Through Rate]
347[9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter [Through Rate]
348[9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter [Through Rate]
349[9.62.1]Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 1. 100 mm diameter [Through Rate]
350[9.62.2]Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 2. 150 mm diameter [Through Rate] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56202714
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 10-07-2026
Authority
Authority Name Shri Vishwakarma Skill University
Work Description Tender for Construction Of Lecture Hall At Svsu, Palwal
Basic Detail
Tender No 2026F4AEBC83 CCE9 45FD 9DAE 8E0DDB5230921845SVS
Bidding Type Tender
Location
City Faridabad
State Haryana
Key Dates
Publish Date 27 Jun 2026
Submission Date 10 Jul 2026
Open Date 13 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 23600
EMD 27.15 Lakhs
Exemption Available
Document List
4e44a3fd-4c02-419d-816f-266a899bfd76.html
BOQ_611343.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

4e44a3fd-4c02-419d-816f-266a899bfd76.html

xls

BOQ_611343.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders