Tender For Cable With Termination For Second Point 11Kv Power Supply At Sukuntala Park Bps
Tender Value
3.42 Lakhs
Estimated cost
Bid Submission
07 Jul 2026
3 days left
EMD
7000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Cable With Termination For Second Point 11Kv Power Supply At Sukuntala Park Bps
BOQ
| Sl. No. | Item Description |
| 1 | SUPPLYING OF FOLLOWING THREE CORE HT POWER CABLE WITH STRANDED COMPACTCIRCULAR ALLUMINIUM CONDUCTOR ,CONDUCTOR SCREEN WITH EXTRUDED SEMI CONDUCTING COMPUND,XLPE INSULATED , INSULATION SCREENING WITH EXTRUDED SEMI CONDUCTING COMPOUND IN COMBINATION WITH COPPER TAPE ,CORES LAID UP , INNERSHERSHEATH OF PVC , GALVANISED STEEL FLAT STRIP ARMOURED AND OVERALL PVC SHEATED CABLE CONFORMING TO IS 7098 (PART-2) 2011 WITH UP TO DATE AMENDMENTS .11KV (UE)CABLE SIZE 300 SQMM [UNIFIED SCHEDULE OF RATES (ELECTRICAL & MECHANICAL )IW DEPT , ITEM 5.3A/3,PAGE 102] |
| 2 | SUPPLYING AND MAKING INDOOR CABLE END TERMINATION WITH HEAT SHRINKABLE JOINTING KIT COMPLETE WITH ALL ACCESSORIES INCLUDING LUGS SUITABLE FOR FOLLOWING SIZE OF 3 CORE , XLPE ALUMINIUM CONDUCTOR CABLE OF 11KV GRADE AS REQUIRED : 3M /RAYCHEM MAKE (A) 240 - 300 SQ. MM. [UNIFIED SCHEDULE OF RATES (ELECTRICAL & MECHANICAL ) IW DEPT , ITEM 5.3C/1,PAGE 104] |
| 3 | LAYING OF ONE NUMBER PVC INSULATED AND PVC SHEATHED /XLPE POWER CABLE OF 11KV GRADE OF FOLLOWING SIZE IN THE EXISTING MASONRY OPEN DUCT AS REQUIRED. (B) ABOVE 120 SQ. MM AND UP TO 400 SQ. MM [UNIFIED SCHEDULE OF RATES (ELECTRICAL & MECHANICAL ) IW DEPT , ITEM 5.3B/4,PAGE 103] |
| 4 | SUPPLY ,DELIVERY & FIXING OD 11KV HEATSHRINK TUBE FOR HEAT SHRINKABLE ANTI TRACKING HIGH VOLTAGE BUSBAR PER METER.RATE ANALYSIS APPROVED BY DG (WS ) ON 31/01/2019 |
| 5 | FITTING FIXING OF CURRENT TRANSFORMER AT HT SWITCH GEAR. RATE ANALYSIS APPROVED BY DG (WS ) ON 31/01/2019 |
| 6 | HIGH VOLTAGE TEST BY 9 KV D.C. (RECTIFIED A.C.)BY PARTY FOR THE FITNESS OF THE SWITCH GEARS FOR FURTHER OPERATION RATE ANALYSIS APPROVED BY DG(WS) ON DATED 31/01/19. |
| 7 | SERVICING, TESTING, CALIBRATION OF OVERCURRENT, EARTH FAULT C.D.G TYPE RELAY . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 8 | SERVICING, TESTING, CALIBRATION OF V.A.A/V.A.X/V.A.G.M/V.A.J/V.A.G TYPE RELAY. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 9 | DRAWING OUT THE VACUUM CIRCUIT BREAKER AFTER RACKING DOWN & DISCONNECTING ALL THE CONNECTION OF VCB'S AT 6 KV PANEL .FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 10 | CLEANING OF THE INSIDE & OUTSIDE OF THE BREAKER ASSEMBLY FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 11 | CHECKING OF TRIP MECHANISM, TRIP COIL ASSEMBLY, CONNECTION & CONNUTI OF AUXILIARY SWITCH ASSEMBLY FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 12 | CHECKING OF OPERATION OF BREAKER CHARGING HANDLE, BREAKER TERMINALS, IT'S MOUNTING ARRENGEMENT & MOVEMENT OF IT AND ALSO SUPPORT INSULATOR (BUSBAR) FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 13 | CHECKING OF CONTINUTY OF PINS OF SECONDARY PLUG & SOCKET ASSEMBLY THROUGH 110V D.C IS SUPPLIED TO BREAKER.. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 14 | CLEANING CHECKING, TIGHTENING OF ISOLATING EPOXY SPOUTS FOR DRAWOUT VCB (MALE & FEMALE) & BREAKER CHARGING MECHANISM. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 15 | CHECKING THE GEAR BOX ASSEMBLY FOR DRAWOUT VCB WITH PROPER GREASING & OILING OF THE PARTS AS REQUIRED. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 16 | CHECKING , ADJUSTMENT OF PUSH TO TRIP ASSEMBLY, SPRING CHARGE INDICATOR, EARTHING ASSEMBLY WITH FLEX, BOTTLE WITH BOTTLE ASSEMBLY & TENSION OF CONTRACT SPRING, CLOSING SPRING FOR VCB . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 17 | CLEANING THE BREAKER CHARGING MOTOR ASSEMBLY AND CHEACKING THR I.R VALUE OF THE MOTOR . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 18 | CHECKING THE ADJUSTMENT OF BREAKER LOCKING DEVICE AND OPERATION OF ANYI-PUMPING RELAY ASSEMBLY . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 19 | CHECKING, ADJUSTMENT OF AUTOMATIC SHAFT SHUTTER OPERATION OF VCB . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 20 | CHECKING, TIGHTENING OF THE LEVEL MECHANISM OF VCB . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 21 | CHECKING ELECTRICAL & MECHANICAL 'ON-OFF' OPERATION OF THE VCB IN TEST POSITION. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19 |
| 22 | Supply & fixing of 230/240V, LED indicating lamp (make :AE/KAPPA/IMP) Blue/ white color. |
| 23 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP |
| 24 | Sub Total |
| 25 | GST 18% |
| 26 | CESS 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 27, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender