Tender For Repair/ Replacement And Improvement Of Mcc Panel, Starter, Pump Moters Earthing Of Plant, Em Assets At Stp, Dg, Lift Fire Fighting Etc At Mil Stn Gandhinagar
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Jul 2026
15 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gandhinagar → Gujarat
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement And Improvement Of Mcc Panel, Starter, Pump Moters Earthing Of Plant, Em Assets At Stp, Dg, Lift Fire Fighting Etc At Mil Stn Gandhinagar
BOQ
| Sl. No. | Item Description |
| 1 | Repair to existing Starter panel of 10-20 HP by taking out old U/S star/delta starter from panel with bakelite frame of appropriate size with all fixtures like Contactor, timer, terminal block, Overload relay, wiring etc and replacement of following items:- |
| 2 | Supply and Fix in reapir/replacement of 40A contactor-AC3 duty |
| 3 | Supply and Fix in repair/Replacement of soft starter 12-18 A |
| 4 | Supply and Fix in reapir/replacement of power and control wiring with proper lugs, ferrule, PVC for coding A to Z and No 0 to 9 as per detailed drawing approved by GE, Drgs shall be submitted by contractor for power and control wiring with all terminal block. |
| 5 | Supply and Fix in repair/replacement of automatic Phase sequence controller and level controller with logic control drgs complete all as specified and directed by Engr-in-charge. |
| 6 | Supply and Fix in repair/replacement of MPCB 12-25 A rating complete with all necessary accessories and mountings |
| 7 | Repair to existing Starter panel of 20-30HP by taking out old U/S star/delta starter from panel with bakelite frame of appropriate size with all fixtures like Contactor, timer, terminal block, Overload relay, wiring etc and replacement of following items: |
| 8 | Supply and Fix in reapir/replacement of 60A contactor-AC3 duty |
| 9 | Supply and Fix in repair/Replacement of soft starter 30-50 A |
| 10 | Supply and Fix in reapir/replacement of power and control wiring with proper lugs, ferrule, PVC for coding A to Z and No 0 to 9 as per detailed drawing approved by GE, Drgs shall be submitted by contractor for power and control wiring with all terminal block. |
| 11 | Supply and Fix in repair/replacement of automatic Phase sequence controller and level controller with logic control drgs complete all as specified and directed by Engr-in-charge. |
| 12 | Supply and Fix in repair/replacement of MPCB 50 A rating complete with all necessary accessories and mountings |
| 13 | Repair to existing Starter panel of 40 HP by taking out old U/S star/delta starter from panel with bakelite frame of appropriate size with all fixtures like Contactor, timer, terminal block, Overload relay, wiring etc and replacement of following items: |
| 14 | Supply and Fix in reapir/replacement of 100 A contactor-AC3 duty |
| 15 | Supply and Fix in repair/Replacement of soft starter 60-80 A |
| 16 | Supply and Fix in reapir/replacement of power and control wiring with proper lugs, ferrule, PVC for coding A to Z and No 0 to 9 as per detailed drawing approved by GE, Drgs shall be submitted by contractor for power and control wiring with all terminal block. |
| 17 | Supply and Fix in repair/replacement of automatic Phase sequence controller and level controller with logic control drgs complete all as specified and directed by Engr-in-charge. |
| 18 | Supply and Fix in repair/replacement of MPCB 100 A rating complete with all necessary accessories and mountings |
| 19 | Note:- Before execution the work control and power drgs with all necessary accessories and mountings complete with BoQ as mentioned in Sr item no 1 to 3 shall be approved by GE. |
| 20 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-in-charge Please Enable Macros to View BoQ information |
| 21 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-in-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysJul 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender